GovChime
Notice ID: b96f9f97991b45bf82fd4f46aa743d1cAward NoticeAwarded

C1DA--AE Design- Replace/Upgrade Electrical Switchgear Phase IV Birmingham VAMC

Awarded on August 24, 2023. Full description on SAM.gov.

Awarded tounder 36C24723C0136 (source: SAM.gov award notice)• $823.0K

Overview

Posted
August 24, 2023
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS
541330: Engineering Services
Agency
Department of Veterans Affairs

Notice details

Place of performance
Birmingham VA Medical Center 700 19th St S, Birmingham, 35233
Last updated
Dec 4, 2025
Award date
Aug 24, 2023
Award amount (SAM.gov award notice)
$823.0K

Identifiers

Solicitation number
36C24723R0068
Notice ID
b96f9f97991b45bf82fd4f46aa743d1c
Award number (PIID)
36C24723C0136

Description

THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL; NO SOLICITATION PACKAGE WILL BE ISSUED UNTIL AFTER AN EVALUATION HAS BEEN MADE ON THE PROVIDED SF-330. ARCHITECT-ENGINEERING (A/E) DESIGN SERVICES: 1. The Department of Veteran Affairs Network 7 Contracting Office is seeking qualified Architect-Engineering (AE) firms to submit Standard Form 330 (SF 330) Architect/Engineering Statement of Qualifications for Project # 521-24-101 Replace/Upgrade Electrical Switchgear Phase III. Firms submitting qualification packages must be fully licensed to perform designs as a registered professional AE firm in the United States to be considered for this opportunity. Also, see geographic location restriction in paragraph 5 of this notice. 2. Network Contracting 7 VA Facility location: Birmingham VA Medical Center 700 19th St S, Birmingham, AL 35233 3. This acquisition is a 100% set aside for Small Disabled Veteran Owned Small Business. a. Prospective Contractors are cautioned that proposal submitted in response to this solicitation must meet the criteria identified by 38 CFR, Part 74. The SDVOSB concern agrees that in the performance of the contract, the concern will comply with the limitation on subcontracting requirements in accordance with VAAR Clause 852-219-10, VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside. b. For a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a prospective contractor, the firm, including Joint Ventures, must be verified and registered in the Department of Veteran Affairs (VA) Office of Small & Disadvantaged Business Utilization (OSDBU) Vendor Information Pages (VIP), VETBIZ (www.vip.vetbiz.gov , registered in the System for Award Management (SAM) database (www.sam.gov) at time of submission of their qualification and reporting to VETS -4212 Federal Contractor Reporting in accordance with FAR 52.222-37, Employment Reports on Veterans at https://www.dol.gov/agencies/vets/programs/vets4212. Failure of a prospective SDVOSB to be verified by the Center for Veterans Enterprise (CVE) at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13 CFR 125.15 prior to contract award. 4. Contract Information: A Firm Fixed Price A/E Design service contract is contemplated for Project # 521-16-103 Replace/Upgrade Electrical Switchgear Phase III. The estimated magnitude of construction for this project is between $5,000,000.00 and $10,000,000.00. The estimated/target design completion period is 270 calendar days after issuance of Notice to proceed. The NAICS code for this acquisition is 541330, Engineering Services with a size standard of $22.5 million. 5. The primary place of performance will be at the Consultant s facility; however, some may require work to be performed at Government facilities. Any work at the Government site shall not take place on Federal holidays or weekends unless directed by the Contracting Officer (CO). 6. Project Information/Statement of Tasks: The AE shall provide technical services for the complete design for Project #521-24-101, Replace/Upgrade Electrical Switchgear Phase IV. Required documents typically include schematics preliminary plans, working drawings, phasing plans, specifications, cost estimates, and construction documents (final drawings, specifications, and cost estimate). The intent of this project is to replace existing electrical distribution system components which have been identified on the facility condition assessment as having reached the end of their useful life in various areas of the Birmingham VA Medical Center. Work may include, but is not limited to, architectural, electrical, HVAC, fire protection and plumbing. 7. Selection Criteria: The A/E Source Selection Team shall utilize the following selection criteria listed in descending order of importance: Professional qualifications necessary for satisfactory performance of required service and working together as a team (in-house and/or consultants(s)). Note: The firm and A/E on staff representing the project or signing drawings in each discipline must be registered/licensed to practice in the United States. Provide your information on the SF 330 clearly marked by providing a current architect and/or engineering License numbers AND proof of Licensure. The VA will confirm the individuals are current and in good standing with the respective state license board. Specialized experience and technical competence in the type of work required, including but not limited to: Architecture, Electrical, Plumbing, Mechanical, Fire Protection, Abatement/Industrial Hygiene, Cost Estimation, Project Management and where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. (Include Government and private Experience on similar projects) Capacity to accomplish work in the required time. Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. Location in general geographical area and knowledge of the locality of the project and that your proximity to the general geographical area enables you to respond to emergency calls in person within 24 hours if required. (SF 330 submittal should show your knowledge of the locality of the project.) Eligible prime contractor firms must have a main and/or branch office geographically located within 400-miles of Birmingham VAMC. The Government will use MapQuest to determine milage from AE Firms Offices or Branch Offices to Birmingham VAMC. The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates. Reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. (Awards, Outstanding Merits, Recommendations. Specific experience and qualifications of personnel proposed for assignment to the project. 8. Selection Procedures: a. This requirement is being procured in accordance with The Brooks Act of 1972, Federal Acquisition Regulation 36.6 (FAR) and VA Acquisition Regulation 836.6 (VAAR) and VA Acquisition Manual (VAAM) 836.6. Firms responding to this announcement by submitting a qualifying SF 330, before the closing date and time, will be considered for initial selection evaluation. Following initial evaluation of the SF330s received three or more firms that are considered the most highly qualified to provide the type of services required will be selected for interviews. Selected firms will be notified by telephone or email of selection and provided further instructions. b. Selection and evaluation of firms shall be made based on SF 330 submissions and direct responses to the selection criteria identified herein. Failure to address all selection criteria will result in a decreased rating. c. Evaluating past performance and experience may include information provided by the firm, customer inquiries, Government databases, and Contracting Officer knowledge of current project performance. Failure to provide requested data, accessible points of contact or valid phone numbers could result in a firm being removed from consideration. d. Firms that design or prepare specifications in conjunction with this contract are prohibited from participating on any future construction contracts based on those documents. All projects identified on the SF330 must be completed by the office/branch/individual team member performing the work under this contract. 9. Submission Requirements: a. The SF 330 form may be downloaded from http://www.gsa.gov/portal/forms/type/SF Completed SF 330 s shall include the primary firms, subcontractor firms and any consultants expected to be used on the project. Do not submit information incorporating by reference. Prospective firms shall address all selection criteria factors within their submitted SF330 packages. The following format shall be used: (1) Cover Page with Solicitation Number, Project Title (2) Table of Contents (3) SF 330 s (4) Acceptability under other appropriate evaluation criteria; i.e. SF 330, Section H. (a) Management Plan i. Management Process ii. QA/QC iii. Cost Control/Design within Funding Limitations iv. Schedule Control (b) Proposed Design Approach (c) Estimating Effectiveness (d) Capacity to accomplish the work in the required time. (e) Awards received (5) Copy of Current A/E state Engineer/Architect License (6) Copy of current vetBiz.gov SDVOSB certification (7) Unique Entity Identifier (UEI) Number (8) Tax ID number (9) The E mail address and Phone number of the Primary Point of Contact. b. SF 330 Date of Receipt/Due Date: Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than (NLT) no later than Monday, May 15, 2023, by 10:00 CST. Email capacity is limited to five (5) to seven (7) megabyte (Megs). c. All SF330 submittals and questions must be sent electronically to the attention of Joseph Osborn, Contracting Officer at Joseph.Osborn@va.gov . Please provide Pre-Solicitation Number, Project Title, and Firm Name in Subject Line of email. When submitting SF330s, if more than one email is sent, please number emails in Subjects as 1 of n . Submittals received after the date and time identified on page one (1) will not be considered. Firms not providing the required information may be negatively evaluated. Facsimile submittals will not be accepted. All information must be included in the SF330. d. The SF-330 including title page, table of contents, and any other relevant information shall not exceed a total of 50 pages in a common font size 12 font, single spaced. The proposal shall be submitted as a single application-generated (not scanned), searchable PDF document. A page is defined as each face of an 8.5 X 11-inch sheet of paper containing information. The page limitation does not apply to the licenses, contract performance evaluations, (i.e. CPARS) and award documentation. This information should be provided as attachments to the SF 330. e. All questions regarding this announcement must be emailed to the Contracting Officer Joseph.Osborn@va.gov no later than Thursday, April 27, 2023, by 10:00 CST to allow time to respond. Site Visits will not be arranged during this phase. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL. THIS IS A PRE-SOLICITATION NOTICE FOR ARCHITECT/ENGINEERING (A/E) DESIGN SERVICES; NO SOLICITATION PACKAGE WILL BE ISSUED UNTIL AFTER AN EVALUATION HAS BEEN MADE ON THE PROVIDED SF-330. ONLY THE A/E FIRMS RESPONDING TO THIS ANNOUNCEMENT BY SUBMITTING AN SF330 PACKAGE ON TIME WILL BE CONSIDERED FOR INITIAL EVALUATION.

Full description on SAM.gov

Award Overview

Award Number

36C24723C0136

Award Amount (SAM.gov award notice)

$823.0K

Award Date

Aug 24, 2023

Awardee

Awardee UEI

NLV6UAD1LKV8

Awardee CAGE Code

5UF00

Original Solicitation

Notice ID: b96f9f97991b45bf82fd4f46aa743d1c

Posted Date: Aug 24, 2023

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • VA24716J1100
    TOLAND MIZELL MOLNAR LLC
    Department of Veterans AffairsNAICS 541330
    $454.6KSigned Nov 13, 2026
  • 36C24826N0229
    TOLAND MIZELL MOLNAR LLC
    Department of Veterans AffairsNAICS 541330
    $91.1KSigned Nov 9, 2026
  • 36C24127N0053
    TOLAND MIZELL MOLNAR LLC
    Department of Veterans AffairsNAICS 541330
    $221.8KSigned Nov 5, 2026
  • 36C10F25A0006
    TOLAND MIZELL MOLNAR LLC
    Department of Veterans AffairsNAICS 541330
    —Signed Oct 26, 2026
  • 36C24822N0877
    TOLAND MIZELL MOLNAR LLC
    Department of Veterans AffairsNAICS 541330
    $1.0MSigned Oct 22, 2026

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24723R0068
  1. Pre-Solicitation
  2. Awarded

This opportunity has been awarded.

  1. Pre-SolicitationApr 13, 2023

    C1DA--AE Design- Project #521-24-101 - Replace/Upgrade Electrical Switchgear Phase IV

    Notice a525eae1d0714a6194c5440b1934bd0f on SAM.gov

  2. AwardedCurrentAug 24, 2023

    C1DA--AE Design- Replace/Upgrade Electrical Switchgear Phase IV Birmingham VAMC

    Notice b96f9f97991b45bf82fd4f46aa743d1c on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Sources Sought Notice THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL. THE GOVERNMENT WILL NOT PAY NOR REIMBURSE ANY COSTS ASSOCIATED WITH RESPONDING TO THIS REQUEST. THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. The Department of Veterans Affairs is seeking a qualified Architect-Engineering (AE) firm to provide Schematics, Design Development, Construction Documents, Technical Specifications, Construction Period Services, Site Visits, Cost Estimates, As-Built Documentation, and all other related information for Project 58A5-27-503 Project Design Replace Flat Roof at the Canandaigua VA Medical Center, 400 Fort Hill Avenue, Canandaigua, NY 14424. this project is to develop a conditions-report and design documents for replacing the existing flat roofs on buildings 4, 5, 6, 7, 8, 10, 36, 37, 118, and various connecting tunnels. The conditions report shall be prepared after a thorough investigation of the existing conditions with estimated costs and improvements. The following design will include all selected repairs and improvements from the conditions report that fit within VA construction budget. As part of the report and design effort, the existing conditions shall be tested and verified, including evaluation of the drainage, materiality, masonry, fall protection, equipment, ACM, insulation, and structural integrity. New work may include redesign / reconstruction of support structures, drainage, roof type change, and parapet wall restoration to ensure water intrusion and legacy issues are mitigated. In addition to repairs and modifications, all interior drainage piping shall be replaced minimum 10 from roof drain unless, otherwise discussed with VA for convenience or practical reasons or as needed due to conditions of ease or degradation. This requirement is being procured in accordance with the Brooks Act as implemented in FAR Subpart 36.6. Applicable NAICS code is 541330 and small business size standard of $25.5 Million. Magnitude of Construction is between $500,000 and $1,000,000. This is a 100% Service-Disabled Veteran Owned Small Business Set Aside. The anticipated award date of the proposed A-E Contract is on or before December 30, 2026. Potential contractors must be registered in SAM (www.sam.gov ) and are visible/verified/certified as SDVOSB in Dynamic Small Business Search (https://dsbs.sba.gov/search/dsp_dsbs.cfm) at time of submission of their qualifications in order to be considered for an award. In order to assure compliance with VAAR clauses, 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction (NOV 2022) and 852.219-73 VA Notice to Total Set-Aside for Verified Service-Disabled Veteran-Owned Small Businesses (NOV 2022), all firms submitting a SF 330 for this notice are required to indicate what percentage of the cost of contract performance will be expended on the concerns employees and in which discipline(s) and percentage of cost of contract performance to be expended (and in what disciplines) by any other consultant/subcontractor or otherwise used small or large business entity(s). Any consultant/subcontractor or otherwise business entity(s) used must be identified by name, office location and size/type of business (i.e., SDVOSB, VOSB, 8(a), small, large, etc.). Failure to provide this information will deem the firm s SF 330 submittal as non-responsive and preclude further evaluation All A/E firms are advised that in accordance with VAAR 836.606-71 the total cost of the production and delivery of designs, plans, drawings and specifications shall not exceed six (6) percent of the estimate cost of construction. Other A-E fees are not included in the six (6) percent. Additionally, FAR Clause 52.236-22 (c) - Design Within Funding Limitation, will be applicable to this procurement action. SCOPE OF SERVICE REQUIRED Project no. 528A5-27-503: A/E Design Replace Flat Roof LOCATION Canandaigua VAMC, 400 Fort Hill Avenue Canandaigua, NY 14424 COST RANGE Magnitude of Construction is between $500,000.00 and $1,000,000.00 Estimated Construction Cost Range: $5,000,000. TYPE OF CONTRACT CONTEMPLATED The Department of Veterans Affairs is contemplating awarding a firm fixed price contract. DESIGN COMPLETION PERIOD: The Department of Veterans Affairs requires design and contract support services. The A/E shall deliver 100% bid documents in 255 calendar days from the Notice to Proceed (NTP). SELECTION CRITERIA DESCRIPTIONS The submitted SF-330s will be evaluated on the following criteria: This acquisition will be in accordance with FAR Part 36.602-1 and VAAR Part 836.602-1. The following evaluation criteria will be used to evaluate SF-330 technical proposals: The A/E must demonstrate its qualifications with respect to the published evaluation criteria for all services. Evaluation Criteria is of equal importance with an exception of criterion 1 and 7 which shall carry an additional weight multiplier of 1.5. Each criterion shall be rated out of a score of 1 to 10. Total possible score is 80. Specific evaluation criteria include: 1.Specialized experience and technical competence in the type of work required, including, roof replacements, structural repairs, drainage, temporary systems and investigative services. 2. Professional Qualifications necessary for performance of site surveys such as the one described within the SOW including qualified personnel and approach to this scope. 3. Capacity to accomplish the work in the required time. 4. Past Performance on contracts with Government agencies and private industry in terms of cost control, quality of work and compliance with performance schedules. 5. Specific experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. 6. Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. 7. Specific examples of survey documents as described in the scope of work and approach to preparation of the documents as requested by the VA. 8. Record of significant claims against the firm because of improper or incomplete architectural and engineering services. Criterion 1 - Specialized experience and technical competence in the type of work required, including, roof replacements, structural repairs, drainage, temporary systems and investigative services. Offerors will be evaluated on specialized experience and technical competence in the performance of services similar to those anticipated under this contract with regard to: Experience with roofing systems. Experience with design of building drainage systems. Experience with specialized HVAC and electrical design for healthcare facilities. Experience in providing post construction award services (shop drawing review, as-built drawing and Quality Assurance Plan (QAP) preparation, construction inspection services, and Operating and Maintenance Manuals). Experience with government designs and construction. Experience with historic buildings, preservation, and alterations. Submission requirements: Provide a detailed write-up of how the firm has accomplished the requirement. In addition, provide up to five (5) projects completed or substantially completed within the past five (5) years that best illustrate specialized experience of the proposed team in the areas outlined above. Example projects shall note project s square footage. All projects provided in the SF-330 must be completed by the office/branch/regional office/individual team member actually proposed to manage and/or perform work under this contract. To enable verification, firms should include the DUNS number along with each firm name in the SF-330 Part 1, Section F Item 25 Firms from Section C Involved in this Project, block (1). Include a contract number or project identification number in block 21. Include an e-mail address and phone number for the point of contact in block 23(c). Include in the project description the contract period of performance, award contract value, current contract value, a summary of the work performed that demonstrates relevance to specialized experience as outlined above. If the contractor served as a subcontractor on a project, indicate the value of the work they provided towards the performance of the overall project. If a project was performed by a joint venture, and not all joint venture partners are on the team proposed for this contract, the offeror/team should specifically address the work performed by the joint venture partner offering/teaming on this contract. Likewise, if the offeror/team member worked as a subcontractor on a project, the description should clearly describe the work actually performed by the offeror/team member and the roles and responsibilities of each on the project, rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project could be eliminated from consideration. NOTE: If the Offeror is a joint venture, information should be submitted as a joint venture; however, if there is no information for the joint venture, information should be submitted for either joint venture partner, not to exceed a total of five (5) projects for this criterion. Projects shall be submitted on the SF-330. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award. Do not list an IDIQ contract as an example of a completed project. Instead, list relevant completed task orders or stand-alone contract awards that fit within the definition above. Examples of project work submitted that do not conform to this requirement will not be evaluated. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being rated lower. All information for Criterion 1 should be submitted in Part 1, Section F of the SF-330. The Government WILL NOT consider information submitted in addition to Part 1, Section F in evaluating Criterion 1. Criterion 2 - Professional Qualifications necessary for performance of site surveys as the one described with the SOW including qualified personnel and approach to this scope. Offerors will be evaluated in terms of the qualifications, competence and experience of the key personnel and technical team proposed to accomplish this work. Key personnel are individuals who will have major contract or project management responsibilities and/or will provide unusual or unique expertise. Provide a balanced licensed and or certified workforce in the following disciplines Architecture, Structural, Mechanical, Electrical, Interior Design, Environmental services and Historic Preservation Submission requirements: Provide a detailed description of how the team has performed site surveys and would approach the survey for this project. In addition, provide resumes for all proposed key personnel. Resumes are limited to one page each and should cite project specific experience and indicate proposed role in this contract. Provide professional registration, certification, licensure and/or accreditation. Indicate participation of key personnel in example projects in the SF-330 Part 1 Section G. Criterion 3 - Capacity to accomplish the work in the required time. Firms/teams will be evaluated in terms of their ability to plan for and manage work under the contract and capacity to accomplish the work in the required time. Submission requirements: Describe the firm s ability to concurrently perform and manage multiple projects in different locations to meet aggressive schedules, multiple disciplines, and control costs and the firm s capacity to accomplish multiple projects simultaneously. Criterion 4 - Past Performance Offerors will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided in Past Performance Questionnaires (PPQs) or CPARS/ACASS for Criterion 1 projects and may include other information provided by the firm, customer inquiries, Government databases, and other information available to the Government including contacts with points of contact in other criteria. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being rated lower. NOTE: Past performance information for projects listed under Criterion 1. Submission requirements: SUBMIT A COMPLETED CPARS/ACASS EVALUATION FOR EACH PROJECT UNDER CRITERION 1. IF THERE IS NOT A COMPLETED CPARS/ACASS EVALUATION, the Past Performance Questionnaire (PPQ) included in this notice is provided for the offeror or its team members to submit to the client for each project the offeror includes under Criterion 1. Criterion 5 - Specific experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. Submission requirements: Offerors shall submit evidence of individuals experience and qualifications in their respective fields. Additionally, documentation must be provided to show these individuals have worked together as a team on previous projects and their role. (Completing Sections E, F, and G, on the SF-330 meets the documentation requirement). Furthermore, offerors shall describe the ability of the firm to manage, coordinate and work effectively with team members, both internal staff and consultants. Discuss the history of working relationships with team members, including joint venture partners where applicable. Criterion 6 - Location within a 400-mile radius to the design site (Canandaigua, NY) and knowledge of the location (Canandaigua, NY); provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. Provided that the application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the contract, firms/teams will be evaluated on the locations of their office or offices that will be performing the work under this contract. Submission requirements: Indicate firms/teams location, including main offices, branch offices and any subconsultants offices and demonstrate how this will be advantageous to the Government. Do not include office locations is no team members are to be working from or located at. Criterion 7 Specific examples of survey documents as described in the scope of work and approach to preparation of the documents as requested by the VA. Submission requirements: Offerors shall provide documentation written description and examples of firm s ability to perform. Criterion 8 - Record of significant claims against the firm because of improper or incomplete architectural and engineering services. Offerors with substantiated claims against the firm as a result of improper architectural and engineering services provided in the last three (3) years. Submission requirements: Records and any other documentation of substantiated claims highlighting improper or incomplete architectural engineering services against the firm within the last three (3) years. The SF-330 shall contain a statement affirming that there are no records of significant claims because of improper or incomplete architectural and engineering services. Evaluation Scoring Evaluation factors 1, 2, 3, 5, 7, and 8 will be evaluated 1-10 using the following adjectival ratings as follows: Outstanding (10): Proposal meets requirements and indicates an exceptional approach and understanding of the requirements. Strengths far outweigh any weaknesses. Risk of unsuccessful performance is very low. Good(7-9): Proposal meets requirements and indicates a thorough approach and understanding of the requirements. Proposal contains strengths which outweigh any weaknesses. Risk of unsuccessful performance is low. Acceptable(4-6): Proposal meets requirements and indicates an adequate approach and understanding of the requirements. Strengths and weaknesses are offsetting or will have little or no impact on contract performance. Risk of unsuccessful performance is moderate. Marginal(1-3): Proposal does not clearly meet requirements and has not demonstrated an adequate approach and understanding of the requirements. The proposal has one or more weaknesses which are not offset by strengths. Risk of unsuccessful performance is high. Unacceptable(0): Proposal does not meet requirements and contains one or more deficiencies. Proposal is not awardable. The firm s proposal demonstrates a misunderstanding of the requirement, and the approach fails to meet performance standards. The firm s proposal has major omissions and inadequate details to assure evaluators that the offeror has an understanding of requirement. The ratings identified below were used in the evaluation of Past Performance (Criterion 4): Substantial Confidence(10): Based on the offeror s recent/relevant performance record, the Government has a high expectation that the offeror will successfully perform the required effort. No doubt exists based on the offeror s past performance that they can satisfy the requirements of the contract. Satisfactory Confidence (7-9): Based on the offeror s recent/relevant performance record, the Government has a reasonable expectation that the offeror will successfully perform the required effort. Little doubt exists based on the offeror s past performance that they could satisfy the requirements of the contract. Unknown Confidence (Neutral 5-6): No recent/relevant performance record is available, or the offeror s performance record is so sparse that no meaningful confidence assessment rating can be reasonably assigned. Limited Confidence (1-3): Based on the offeror s recent/relevant performance record, the Government has little expectation that the offeror will be able to successfully perform the required effort. Some doubt exists based on past performance that they could satisfy the terms and conditions of the contract. No Confidence (0): Based on the offeror s recent/relevant performance record, the Government has little expectations that the offeror will be able to successfully perform the required effort. Significant doubt exists based on the offeror s past performance that they can satisfy the requirements of the contract. Rating of criterion 6 shall be a score of 0 for outside of range and 10 for inside of range PLEASE NOTE: The AE Evaluation Board must be provided with complete and accurate information for ALL nine (9) evaluation factors above in order to rank as qualified and eligible firms. Therefore, the AE firm must expand upon, as it deems necessary, on any evaluation factor not well demonstrated or addressed with Part 1A to Part IG and Part II of the SF330. The AE firm shall use Part IH and/or use additional sheets to supplement/address all evaluation factors to clearly demonstrate its qualifications. LIMITATIONS 852.219-10 VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside (DEC 2009) (a) Definition. For the Department of Veterans Affairs, Service-disabled veteran-owned small business concern : (1) Means a small business concern: (i) Not less than 51 percent of which is owned by one or more service-disabled veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled veterans (or eligible surviving spouses); (ii) The management and daily business operations of which are controlled by one or more service-disabled veterans (or eligible surviving spouses) or, in the case of a service-disabled veteran with permanent and severe disability, the spouse or permanent caregiver of such veteran. (iii) The business meets Federal small business size standards for the applicable North American Industry Classification System (NAICS) code identified in the solicitation document; and (iv) The business has been verified for ownership and control and is so listed in the Small Business Pages database, (SBA s Small Business Search); (2) Service-disabled veteran means a veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16). (b) General. (1) Offers are solicited only from service-disabled veteran-owned small business concerns. Offers received from concerns that are not service-disabled veteran-owned small business concerns shall not be considered. (2) Any award resulting from this solicitation shall be made to a service-disabled veteran-owned small business concern. (c) Agreement. A service-disabled veteran-owned small business concern agrees that in the performance of the contract, in the case of a contract for: (1) Services (except construction), at least 50 percent of the cost of personnel for contract performance will be spent for employees of the concern or employees of other eligible service-disabled veteran-owned small business concerns. (2) Supplies (other than acquisition from a nonmanufacturer of the supplies), at least 50 percent of the cost of manufacturing, excluding the cost of materials, will be performed by the concern or other eligible service-disabled veteran-owned small business concerns. (3) General construction, at least 15 percent of the cost of the contract performance incurred for personnel will be spent on the concern's employees or the employees of other eligible service-disabled veteran-owned small business concerns; or (4) Construction by special trade contractors, at least 25 percent of the cost of the contract performance incurred for personnel will be spent on the concern's employees or the employees of other eligible service-disabled veteran-owned small business concerns. (d) A joint venture may be considered a service-disabled veteran owned small business concern if (1) At least one member of the joint venture is a service-disabled veteran-owned small business concern and makes the following representations: That it is a service-disabled veteran-owned small business concern, and that it is a small business concern under the North American Industry Classification Systems (NAICS) code assigned to the procurement. (2) Each other concern is small under the size standard corresponding to the NAICS code assigned to the procurement; and (3) The joint venture meets the requirements of paragraph 7 of the explanation of Affiliates in 19.101 of the Federal Acquisition Regulation. (4) The joint venture meets the requirements of 13 CFR 125.15(b). (e) Any service-disabled veteran-owned small business concern (non-manufacturer) must meet the requirements in 19.102(f) of the Federal Acquisition Regulation to receive a benefit under this program. SUBMISSION REQUIREMENTS: Unless paper offers are specifically authorized in an individual solicitation, all responses to solicitations must be submitted electronically as described below. Responses submitted in a paper form are unacceptable. Failure to comply with this requirement may jeopardize the possibility of receiving an award due to noncompliance with the submission requirements. EMAIL SUBMISSION REQUIREMENTS Interested firms having the capabilities to perform this work must submit: ONE (1) ELECTRONIC SF 330, including Parts I and II, and attachments (if any) to idalia,algarin@va.gov no later than 12PM, Eastern Standard Time (EST) on November 13, 2026. Submittals received after the date and time identified will not be considered. The submittal will be date and time stamped by the Microsoft Email system and will be the official record of receipt for the submission. All SF 330 submissions shall be clearly indicated in subject line, displaying the solicitation number and project number and title (abbreviated and shortened is okay). Submission is to be no more than a total of fifty (50) pages; size of emails is not to exceed 10 megabytes (MB). If more than one email is sent, please number emails in subject lines as 1 of 2, 2 of 2 etc. All SF 330 submissions must include the following information either on the SF 330 or by accompanying document: Cover Page with Solicitation Number, Project Number and Title Table of Contents Copy of valid state registration for each lead designer Copy of current https://veterans.certify.sba.gov/ SDVOSB/VOSB certification DUNS Number Cage Code Tax ID number Email address and Phone number (including the area code) of the Primary Point of Contact.
95%
Market Research11/13/2026
92%
AwardedOpen
89%
AwardedOpen
Description: The Department of Veterans Affairs (VA) seeks to retain an independent third-party Commissioning Agent to perform comprehensive commissioning services for the subject project. This project will replace and repair roofing and lighting protection at the Cincinnati VA Medical Center (Building Numbers: 1, 2, 3, 8, 13, 14, 15, 16 and trailers) including main and Fort Thomas Campuses (Building Numbers: 64, 117 and trailers), in accordance with the general items as written (231000 sq-ft). Selection Criteria: (1) Professional qualifications necessary for satisfactory performance of required services; (2) Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials; (3) Capacity to accomplish the work in the required time; (4) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; (5) Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project; (6) The extent to which potential contractors identify and commit to the use of service-disabled veteran owned small businesses, veteran-owned small businesses, and other types of small businesses as subcontractors. SUBMITTAL INSTRUCTIONS All interested and capable contractors must submit an electronic copy of their SF 330s, via email, by the closing time/date of this announcement. Note the following: No hard/physical copies will be accepted. Limit SF 330 packages to 50 pages. Only the first 50 pages will be evaluated. Submit all documentation as one single file. The total size of the electronic submission (email and all attachments) must not exceed 15MB; larger emails may get rejected by the network server and will be considered non-responsive. Cited relevant projects must be within the last five (5) years. Submit packages via email to the contract specialist by the deadline:Â ronald.heidemann@va.gov Subject line must include the notice number: 36C25027R0011 Please include your firm s POC and UEI in the email body. ***End of Presolicitation Notice**
84%
Pre-Solicitation11/05/2026
Provide complete design services, including all necessary schematics, design development, surveys, cost estimates, construction drawings and specifications, and construction period services (CPS) for solicitation to replace and repair roofing and lighting protection at the Cincinnati VA Medical Center, 3200 Vine Street, Cincinnati, OH 45220 (Building Numbers: 1, 2, 3, 8, 13, 14, 15, 16 and trailers) and the Fort Thomas Campus, 1000 S. Ft. Thomas Ave, Ft. Thomas, KY 41075 (Building Numbers: 64, 117 and trailers), in accordance with the general items as written (231000 sq-ft - estimated). This project will replace and repair the roofing and lightning protection. Replacement of outdated roofing and lighting protection will reduce overall emergency maintenance, increase facility operation, and provide proper protection. SELECTION CRITERIA The Government will evaluate each potential contractor under the terms of its: A. Professional qualifications necessary for satisfactory performance of required services; B. Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials; C. Capacity to accomplish the work in the required time; D. Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; E. Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project; F. Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services, and; G. The extent to which potential contractors identify and commit to the use of service-disabled veteran-owned small businesses, veteran-owned small businesses, and other types of small businesses as subcontractors. SUBMITTAL INSTRUCTIONS All interested and capable contractors must submit an electronic copy of their SF 330s, via email, by the closing time/date of this announcement. Note the following: No hard/physical copies will be accepted. Limit SF 330 packages to 50 pages. Only the first 50 pages will be evaluated. Submit all documentation as one single file. The total size of the electronic submission (email and all attachments) must not exceed 15MB; larger emails may get rejected by the network server and will be considered non-responsive. Cited relevant projects must be within the last five (5) years. Submit packages via email to the contract specialist by the deadline:Â ronald.heidemann@va.gov Subject line must include the notice number: 36C25027R0009 Please include your firm s POC and UEI in the email body. ***End of Presolicitation Notice**
84%
Pre-Solicitation11/04/2026

Additional Details

Solicitation Number

36C24723R0068

Archive Date

Sep 23, 2023

Office Address

AUGUSTA, GA, 30904