Notice ID: 7cc7117bcddf4dce99ec6c2496fc3370Award NoticeAwarded
J046--WATER TREATMENT AND CHILLER PLANT SERVICES BASE PLUS 4 YEAR OPTIONS
Awarded on October 1, 2024. Full description on SAM.gov.
Awarded tounder 36C24725P0018 (source: SAM.gov award notice)• $120.4K
Overview
- Posted
- November 21, 2024
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Place of performance
- Department of Veterans Affairs William Jennings Bryan Dorn VAMC 6439 Gardners Ferry Road, Columbia, SC, 29209
- Last updated
- Jan 23, 2026
- Award date
- Oct 1, 2024
- Award amount (SAM.gov award notice)
- $120.4K
Identifiers
- Solicitation number
- 36C24725Q0026
- Notice ID
- 7cc7117bcddf4dce99ec6c2496fc3370
- Award number (PIID)
- 36C24725P0018
Description
Water treatment service for the Chiller Plant and Boiler Plant at the CVAHCS, WJB Dorn VA Medical Center, 6439 Garners Ferry Road, Columbia, SC 29209.
Award Overview
Award Number
36C24725P0018
Award Amount (SAM.gov award notice)
$120.4K
Award Date
Oct 1, 2024
Awardee
Awardee UEI
DKJJJVFBNQB9
Awardee CAGE Code
69SN9
Original Solicitation
Notice ID: 7cc7117bcddf4dce99ec6c2496fc3370
Posted Date: Nov 21, 2024
Original Response Deadline: Not specified
Contacts
Documents
Showing 1 of 1 items
Document | Source | Agency | Posted Date | File Size | Actions | |
|---|---|---|---|---|---|---|
| Award Notice | Department of Veterans Affairs | Nov 21, 2024 | - |
Lifecycle
Solicitation:
36C24725Q0026- Pre-Solicitation
- Solicitation
- Awarded
This opportunity has been awarded.
- SolicitationJul 18, 2024
J046--WATER TREATMENT AND CHILLER PLANT SERVICES
- 3×Pre-SolicitationJul 18, 2024
J046--WATER TREATMENT AND CHILLER PLANT SERVICES
- 3×SolicitationJul 23, 2024
J046--WATER TREATMENT AND CHILLER PLANT SERVICES
- Pre-SolicitationJul 24, 2024
J046--WATER TREATMENT AND CHILLER PLANT SERVICES
- 3×SolicitationJul 24, 2024
J046--WATER TREATMENT AND CHILLER PLANT SERVICES
- 2×Pre-SolicitationJul 31, 2024
J046--WATER TREATMENT AND CHILLER PLANT SERVICES
- AwardedCurrentNov 21, 2024
J046--WATER TREATMENT AND CHILLER PLANT SERVICES BASE PLUS 4 YEAR OPTIONS
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
76% | Awarded | Open | |
59% | Awarded | Open | |
Boiler Treatment Program located at the VA Illiana Health Care System in Danville, IL. | 59% | Solicitation | 10/21/2026 |
Boiler Treatment Program located at the VA Illiana Health Care System in Danville, IL. | 59% | Pre-Solicitation | 10/08/2026 |
NOTICE OF INTENT TO SOLE SOURCE The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 6, intends to award a Firm Fixed Price Sole-Source contract to Evoqua Water Technologies. The Richmond Veterans Affairs Medical Center (VAMC) has a request for Evoqua Water Technologies, for preventative maintenance service. The justification for this non-competitive solicitation is due to Evoqua Water Technologies, being the sole supplier of requested service to the VA Hospital and Health Care Center. The NAICS code for this procurement is 561990 All Other Support Services $16.5 million. The Sole source service is: Service & Maintenance Items W3TSP3006 Fuel/Energy Surcharge Fixed surcharge applied per service visit. Supports technician travel and operational energy costs needed to perform DI system maintenance. W3TSP3011 PM Contract Recurring (Parts & Labor) Provides recurring annual preventive maintenance for the DI system. Includes all required labor and OEM parts. Ensures system reliability and compliance with regulatory water-quality requirements. W3TSP4346 Conductivity Readings & Record Data Contractor performs conductivity testing of DI water output. Readings ensure water purity meets laboratory standards. W3TSP4408 Adjust Flows and/or Pressures Technician adjusts internal system flows and pressures. Ensures optimal DI production performance and protects downstream equipment. W3TSP4417 Inspect Pumps Inspection and verification of pump condition and operation. Identifies wear, misalignment, inefficiency, or potential failures. W3TSP4418 SDI Test and Record Data Silt Density Index (SDI) testing performed regularly. Indicates particulate loading and pretreatment performance. W3TSP4601 Perform & Replace Prefilter Maintenance per PMI Replacement of prefilters according to manufacturer PMI schedule. Maintains upstream filtration integrity and protects DI media tanks. W3TSP4708 Clean or Sanitize Distribution Loop Full loop cleaning and sanitization using approved disinfectant processes. Prevents microbial growth and maintains water purity throughout distribution. ________________________________________ Consumable/Replacement Parts W2T159701 20" 5µm MB CDF PP Plyfm Cartridge 20-inch depth filter cartridge. 5-micron nominal rating. Multi-bed (MB) CDF polypropylene construction. Removes particulates prior to DI processing. W2T850795 UV Lamp (24W, 254nm, Single-End, 4-Pin) 24 watt ultraviolet germicidal lamp. 254 nm wavelength for microbial reduction. Single end, 4 pin configuration compatible with Evoqua UV housing. W2T850799 Quartz Sleeve QS535 Quartz protective sleeve for UV lamp insertion. Maintains lamp isolation from water stream while ensuring UV penetration. W2T850802 O Ring, LF UV System OEM O ring seal designed for UV system housing. Ensures watertight sealing and prevents bypass leakage. W2T850803 Washer, LF UV Systems OEM washer component for UV lamp housing assembly. Maintains correct compression and secure hardware alignment. W2T918450 20" 0.2µm PLT CDF ABS PS1 SIL Cartridge 20 inch, 0.2 micron absolute-rated cartridge. Designed for final particulate and microbial filtration. Polymer structured (ABS/PS1 SIL) configuration. W2T934633 NIL-8 Test Strip (PAA), 50/Test Tube Test strips for peracetic acid concentration monitoring. Used during sanitization procedures. W2T934634 NIL-8 Test Strip (H O ), 50/Test Tube Hydrogen peroxide concentration test strips. Supports verification of sanitizer effectiveness. W2T936744 NIL-8 Sanitizer (1.5 Gallons) Sanitizing agent used for loop disinfection. Compatible with Evoqua systems and lab water distribution materials. ________________________________________ DI Media Tanks W5TDIMB10360FSP SDI Mixbed 3.6 CF FBGLS STD Pot Mixed-bed deionization tank (3.6 cubic feet). Fiberglass standard pot design. Removes ionic contaminants producing high-purity DI water. W5TDIRAC0360FSP SDI React Carbon 3.6 CF FBGLS STD Pot Activated carbon tank (3.6 cubic feet). Fiberglass standard pot construction. Removes chlorine/chloramine and organics upstream of DI beds. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES, and no Solicitation will be issued. Market research has determined that this product is highly specialized and only available from a single source without an unacceptable delay or duplication of cost and no other type of supply will satisfy agency requirements. The Government intends to award the contract with an effective date on or about October 7, 2026, to Evoqua Water Technologies, 105 47TH ST , Pittsburgh, Pennsylvania 15201. However, interested parties may identify their skill and ability by sending capability statements about this requirement to the Contracting Specialist within three (3) calendar days (October 1, 2026 @ 10am est) of this publication by contacting Cedric Frasier via e-mail cedric.frasier@va.gov. Telephone inquiries will not be accepted. Those interested firms must indicate whether they are large, small, small-disadvantaged, 8(a), or woman-owned businesses and whether they are U.S. or foreign-owned. Respondents who submit proprietary data shall clearly mark the data with appropriate markings. The Government will not pay for any information submitted as a result of this synopsis. This synopsis shall not be construed as an obligation on the part of the Government to acquire any products or services. | 56% | Special Notice | 10/01/2026 |
Additional Details
Solicitation Number
36C24725Q0026
Archive Date
Nov 24, 2024
Office Address
AUGUSTA, GA, 30904