C223--534-25-103 A/E: Correct Air Handling Unit Deficiencies
Archived on August 4, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 3:00 PM EDT
- Posted
- July 21, 2025
- Notice type
- Special Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business Set Aside
- NAICS
- 541310: Architectural Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 247-NETWORK CONTRACT OFFICE 7 (36C247)
- Place of performance
- Ralph H. Johnson Department of Veterans Affairs Medical Center 109 Bee Street, Charleston, 29401
- Last updated
- Nov 11, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24725R0101
- Notice ID
- 6fd4de6d6e4d46e8ad1b210b5ffa5e8c
Description
Under Selection Criteria #1 (specialized experience) it says, Specific emphasis of experience and technical competence shall be geared towards fire protection, seismic design/retrofit, physical security resilience and design, healthcare design/planning, building automatic system design, and mechanical/electrical design. Additionally, under Selection Criteria #3 (professional qualifications) it states Key personnel to provide qualifications to meet this criterion include Principal(s), Project Manager(s), key consultants, individuals responsible for implementation of the Design QA/QC Plan, Licensed Asbestos Inspector, Physical Security Specialist, Life Safety Specialist, and other individuals that are responsible or accountable for design submissions and regulatory compliance. v) Physical Security Subject Matter Experts shall meet the requirements of Section 10.1.5 of the Physical Security & Resiliency Design Manual. It is not clear to us what disciplines should be submitted as Section E key personnel. Based on the scope of work, it appears that some of the listed roles referenced above are not critical to the project. It seems like project manager, mechanical engineer, and electrical engineer would be appropriate key personnel. Please confirm what key roles will be included in your evaluation. To satisfy the scope, A QA/QC Plan is required, a licensed asbestos inspection is required, a physical security specialist is required, and a life safety specialist is required. The scope and location will also require a building automatic system design, seismic design/retrofit design, and fire protection evaluation/design. A project manager, mechanical engineer, and electrical engineer are critical roles; however, the other roles are critical for a comprehensive design that meets the VA TIL Requirements. Is it acceptable to have one individual cover multiple roles/key positions? Yes.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Lifecycle
- 1Version 1Special NoticeArchived
C223--534-25-103 A/E: Amendment Correct Air Handling Unit Deficiencies
- 2Version 2Special NoticeArchived
C223--534-25-103 A/E: Correct Air Handling Unit Deficiencies
- 4Version 4Special NoticeArchivedCurrent
C223--534-25-103 A/E: Correct Air Handling Unit Deficiencies
Other notices for this solicitation
- Pre-SolicitationRelated noticeJun 4, 2025
C223--534-25-103 A/E: Correct Air Handling Unit Deficiencies