GovChime
Notice ID: 6fd4de6d6e4d46e8ad1b210b5ffa5e8cSpecial NoticeArchived

C223--534-25-103 A/E: Correct Air Handling Unit Deficiencies

Archived on August 4, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM EDT
Posted
July 21, 2025
Notice type
Special Notice
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
541310: Architectural Services
Agency
Department of Veterans Affairs

Notice details

Office
247-NETWORK CONTRACT OFFICE 7 (36C247)
Place of performance
Ralph H. Johnson Department of Veterans Affairs Medical Center 109 Bee Street, Charleston, 29401
Last updated
Nov 11, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24725R0101
Notice ID
6fd4de6d6e4d46e8ad1b210b5ffa5e8c

Description

Under Selection Criteria #1 (specialized experience) it says, Specific emphasis of experience and technical competence shall be geared towards fire protection, seismic design/retrofit, physical security resilience and design, healthcare design/planning, building automatic system design, and mechanical/electrical design. Additionally, under Selection Criteria #3 (professional qualifications) it states Key personnel to provide qualifications to meet this criterion include Principal(s), Project Manager(s), key consultants, individuals responsible for implementation of the Design QA/QC Plan, Licensed Asbestos Inspector, Physical Security Specialist, Life Safety Specialist, and other individuals that are responsible or accountable for design submissions and regulatory compliance. v) Physical Security Subject Matter Experts shall meet the requirements of Section 10.1.5 of the Physical Security & Resiliency Design Manual. It is not clear to us what disciplines should be submitted as Section E key personnel. Based on the scope of work, it appears that some of the listed roles referenced above are not critical to the project. It seems like project manager, mechanical engineer, and electrical engineer would be appropriate key personnel. Please confirm what key roles will be included in your evaluation. To satisfy the scope, A QA/QC Plan is required, a licensed asbestos inspection is required, a physical security specialist is required, and a life safety specialist is required. The scope and location will also require a building automatic system design, seismic design/retrofit design, and fire protection evaluation/design. A project manager, mechanical engineer, and electrical engineer are critical roles; however, the other roles are critical for a comprehensive design that meets the VA TIL Requirements. Is it acceptable to have one individual cover multiple roles/key positions? Yes.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Terrence McMillan
Contracting Officer

Documents

Files (3)

  • 36C24725R0101 0003.docx

    16 KBAdded in Special Notice version 4Posted
    Download
  • 36C24725R0101 0002.docx

    14 KBAdded in Special Notice version 2Posted
    Download
  • 36C24725R0101 0001.docx

    14 KBAdded in Special Notice version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Special NoticeArchived

    C223--534-25-103 A/E: Amendment Correct Air Handling Unit Deficiencies

    Notice 1c1b7bbf6c1148bba5a0b70fbe4abae9 on SAM.gov

  2. 2
    Version 2Special NoticeArchived

    C223--534-25-103 A/E: Correct Air Handling Unit Deficiencies

    Notice 9e5489a63a514f87ae034e7ceffaf6da on SAM.gov

  3. 4
    Version 4Special NoticeArchivedCurrent

    C223--534-25-103 A/E: Correct Air Handling Unit Deficiencies

    Notice 6fd4de6d6e4d46e8ad1b210b5ffa5e8c on SAM.gov

Other notices for this solicitation

  1. Pre-SolicitationRelated noticeJun 4, 2025

    C223--534-25-103 A/E: Correct Air Handling Unit Deficiencies

    Notice 13c7b83cb90448099b3e1dd97e5466f5 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

36C24725R0101

Archive Date

Aug 4, 2025