Notice ID: 09931c542f164a938bf781a0f27970a6PresolicitationArchived
J047--EXHAUST DUCT REPLACEMENT
Archived on September 1, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 1:00 PM CDT
- Posted
- August 25, 2025
- Notice type
- Presolicitation
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 247-NETWORK CONTRACT OFFICE 7 (36C247)
- Place of performance
- Department of Veterans Affairs William Jennings Bryan Dorn VAMC Attn: Engineering Services 6439 Gardners Ferry Road, Columbia, 29209
- Last updated
- Nov 8, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24726Q0027
- Notice ID
- 09931c542f164a938bf781a0f27970a6
Description
Sources Sought Notice Sources Sought Notice Page 10 of 10 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 10 All interested vendors are invited to provide information to contribute to this market survey/sources sought including commercial market information. THIS IS NOT A SOLICITATION ANNOUNCEMENT. This is a sources-sought synopsis only. Questions should be submitted by email to terri.hudson@va.gov. Provide only the requested information below. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, FSS/GSA contract schedule holders, and/or large business). POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: 1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and UEI Number. 2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing this type of service. 3) Submit Capability Statements via email to terri.hudson@va.gov by August 29, 2025. Responses should be received no later than 1:00 AM CST. NO CAPABILITY STATEMENTS MAY BE SUBMITTED AFTER AUGUST 29, 2025. AT THIS TIME NO SOLICITATION EXISTS. (DO NOT REQUEST A COPY OF THE SOLICITATION). A FUTURE NOTICE WILL BE POSTED WHEN THE SOLICITATION WILL BE RELEASED. 4) Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. (5) No Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s). STATEMENT OF WORK Exhaust Duct Replacement 1. REQUIREMENT: This requirement is for a one-time service for the replacement of an exhaust duct for room 1C182 in Building 100 (B.100), on behalf of the Columbia Healthcare System, WJB Dorn VA Medical Center located in Columbia South Carolina. 2. BACKGROUND: The WJB Dorn VA Medical Center (VAMC) is a 216-bed facility, encompassing acute medical, surgical, psychiatric, and long-term care. The hospital is in Columbia, South Carolina and provides primary, secondary, and some tertiary care. Satellite outpatient clinics are in Anderson, Greenville, Florence, Orangeburg, Rock Hill, Sumter, and Spartanburg, South Carolina. 3. PERIOD OF PERFORMANCE: The period of performance is based upon award date and shall not exceed two (2) weeks. Normal working hours are 8:00am 4:30pm Monday to Friday, except for federal holidays: FEDERAL HOLIDAYS: New Year s Day, Martin Luther King Jr. Birthday, Presidents Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran s Day, Thanksgiving Day, Christmas Day. 4. PLACE OF PERFORMANCE: WJB Dorn VA Medical Center 6439 Garners Ferry Road Columbia, SC 29209 5. PERFORMANCE REQUIREMENTS: A Contracting Officer Representative (COR) and/or Alternate Contracting Officer Representative (ACOR) shall be assigned to this procurement and written notification will be provided to the Contractor after award. Scheduling of work performance shall be arranged through the designated COR/ACOR assigned. The Contractor shall provide a one-time service to replace the exhaust duct for room 1C182 in B.100. The Contractor shall furnish all labor, travel, equipment, supplies and materials required to perform a replacement to the exhaust duct for room 1C182 in B.100. The contractor is responsible for providing services to detach the existing exhaust duct from the exhaust fan and curb, located on the roof, and install new duct. The contractor will be responsible: For all necessary asbestos abatement. Detach the existing exhaust duct (approximately 8 feet in length) from the exhaust fan and curb located on the roof. Decontaminate and dispose of biohazard components. Fabricate new duct made of 16-Guage or higher; 304 steel type; 2B finish to be field welded on-site. Securely attach the new duct to both the exhaust fan and the roof curb and properly seal. Ensure all seams are welded for the exhaust system. Oversee any qualifications, re-qualifications, and/or testing and balancing of the exhaust fan. Provide a one-year warranty on parts and labor for the materials supplied. The COR will provide acceptance for a fully operational system before any invoice is submitted for payment. CHECK-IN REQUIREMENTS: The Contractor and all personnel associated with the Contractor's services must check in and out with Engineering (ECC) situated in room LB184 of B.100. Shop personnel will escort contract personnel to and from the designated work location. This procedure is essential for contacting mechanics in the event of an emergency during standard operating hours. SAFETY REQUIREMENTS: The contractor ensure all tools and equipment are always secure. Tools and equipment must be removed from open areas or stored in a secure location during breaks, lunch, and/or at the end of each workday. All debris must be removed from the facility upon completion of service each day. Contractors shall ensure proper signage, barriers, and/or blockage of service area is provided where applicable, especially at hoist way doors and clearly visible to ensure patient/employee safety is adhered to. The WJB Dorn VA Medical Center is a smoke free campus. Smoking is not permitted indoors or on campus (except at the Regional Office location), to include parking lots, at any time. All smoking shall be conducted at designated smoking areas. A Site Visit will be required for this requirement. TRAINING REQUIREMENTS: HVAC Certified Technician Certified Ventilation Specialist 6. INVOICES: a. Payment will be made upon receipt of a properly prepared detailed invoice, prepared by the Contractor and submitted through Tungsten Network (formerly known as OB10) http://www.tungsten-network.com/us/en/. A properly prepared invoice shall contain: Invoice Number and Date Contractor s Name and Address Accurate Purchase Order Number Supply or Service provided Period Supply or Service Provided Total Amount Due b. Please begin submitting your electronic invoices through the Tungsten Network for payment processing, free of charge. c. If you have questions about the e-invoicing program or Tungsten Network, contact information is as follows: Tungsten e-Invoice Setup Information: 1-877-489-6135 Tungsten e-Invoice email: VA.Registration@Tungsten-Network.com FSC e-Invoice Contact Information: 1-877-353-9791 FSC e-invoice email: vafsccshd@va.gov Web Address: HTTP://WWW.FSC.VA.GOV/EINVOICE.ASP 7. TERMINATION FOR CONVENIENCE: In accordance with FAR 52.212-4 (l) The Government reserves the right to terminate this contract, or any part hereof, for its sole convenience. 8. RECORDS MANAGEMENT LANGUAGE FOR CONTRACTS: The following standard items relate to records generated in executing the contract and should be included in a typical Electronic Information Systems (EIS) procurement contract: Citations to pertinent laws, codes and regulations such as 44 U.S.C chapters 21, 29, 31 and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228. Contractor shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest. The contractor shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records. Contractors shall not retain, use, sell, or disseminate copies of any delivery that contains information covered by the Privacy Act of 1974 or which is generally protected by the Freedom of Information Act. The contractor shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract. The Government Agency owns the rights to all data/records produced as part of this contract. The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. Contractors must deliver sufficient technical documentation with all data deliverables to permit the agency to use the data. The contractor agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.]. No disposition of documents will be allowed without the prior written consent of the Contracting Officer. The Agency and its Contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Willful and unlawful destruction, damage or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. Records may not be removed from the legal custody of the Agency or destroyed without regard to the provisions of the agency records schedules. 9. CONTRACT SECURITY IDENTIFICATION, SMOKING AND VA REGULATIONS The Contractor's FSE shall wear visible identification always while on the premises of the Augusta VA Medical Center. Contractor shall contact the Contracting Officer s Representative (COR) upon contract award, to receive instructions on how to obtain a VA Identification Badge during the performance of this contract. Augusta VA Medical Center is a smoke free campus which includes both tobacco and e-cigarettes; tickets can be issued by Police Services. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court. Photography or Video on medical center premises is strictly prohibited. Additionally, pursuant to 38 CFR 1.218(b) (23) Use of recording devices of any kind to record patients or employees is strictly prohibited.
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Contract end date
Apr 30, 2026
NAICS
238220
Agency
Department of Veterans Affairs
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C24726Q0027.docx
28 KBAdded in Presolicitation version 3Posted
Links (1)
- Department of Veterans Affairswww.va.govPosted
Lifecycle
- 3Version 3PresolicitationArchivedCurrent
J047--EXHAUST DUCT REPLACEMENT
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Scope: Provide construction services for the replacement and repairing, and all associated structural and plumbing/mechanical as per attached plans and specifications at Hampton, VA Veterans Affair Center: General: The following is a brief summary of the Work: BASE BID: Work includes general construction, alterations, structural and plumbing construction and certain other items as indicated in the contract drawings and specifications sections for building 15 at Hampton, VA Veterans Affair Center. | - | Solicitation | 07/01/2021 |
Solicitation number 1240BE27Q0018 is issued as a Request for Quotation (RFQ) for the replacement of an existing 3-ton packaged heat pump system with a new, high efficiency ENERGY STAR certified unit that also satisfies FEMP federal purchasing requirements for energy consuming products. The unit serves the Laboratory at the Santee Experimental Forest located at 3734 SC-402, Cordesville, SC 29434. Please see attached solicitation and supporting documents for a full description of the requirement. | - | Combined Synopsis | 11/24/2026 |
EO 14398 | Elevator Modernization | CLIN 0096 | Charleston SC | - | Awarded | Open |
Notice to Offerors and Suppliers: Funds are not presently available for this contract. No award will be made under this solicitation until funds are available. The Government?s obligation under this contract is contingent upon the availability of appropriated funds from which payment for contract purposes can be made. No legal liability on the part of the Government for any payment may arise until funds are made available to the Contracting Officer for this contract and until the Contractor receives notice of such availability, to be confirmed in writing by the Contracting Officer. The Government reserves the right to cancel this solicitation, either before or after the closing date. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any costs. The purpose of this requirement is to demolish the existing energy recovery ventilation units (ERU) and replace them with two new Dedicated Outdoor Air Systems (DOAS) in Building 1130 annex in accordance with the Statement of Work. Period of Performance: 115 Calendar Days Competition: This requirement is a competitive 100% Small Business Concern Set Aside for North American Industry Classification System (NAICS) code 238220. The Magnitude of this requirement is valued between $500,000.00 and $1,000,000.00. SITE VISIT ATTENDANCE FOR PRIME CONTRACTORS COMPETING FOR AWARD IS MANDATORY. A site visit is scheduled for Friday, 14 August 2026 at 8:00 AM EDT (local). Please arrive at the Shaw AFB (Main Gate) Visitor Control Center at least 45 minutes prior to the site visit start time to ensure enough time to obtain visitor pass. Completed Base Pass Request Forms (Attachment 09) must be submitted to the Contract Specialist Staff Craig Johnson at email address: craig.johnson.37@us.af.mil and Mr. Darrel Ford at email address: darrel.ford.3@us.af.mil no later than Tuesday, 11 August 2026/2:00 PM EDT (local). Escorts on base will not be provided. No other site visits will be conducted. The site visit meeting location is in front of building 1130. This is a secured facility. No electronic smart/recording devices (Apple Watch, Cell Phone, ear buds, etc.) are allowed in the facility. Please do not bring these items to the (front of building) meeting location. The street address is 524 Shaw Drive, Shaw AFB, SC, 29152. Please do not park in front of the building drive through parking area. This is a designated reserved only parking area. Unauthorized vehicles found parking in this area are subject to ticketing and/or towing. Parking is permitted on the east side of the building where available. Unless otherwise changed in a solicitation amendment, the bid submission due date for this requirement is Friday, 18 September 2026, 1:00 P.M. EDT (local). Solicitation bid opening is on Monday, 21 September 2026/ 9:00 A.M (EDT) local. The bid opening location is the 20th Contracting Squadron Main Conference Room (2nd Floor) 321 Cullen Street, Building 216, Shaw AFB, SC 29152. | - | Combined Synopsis | 09/18/2026 |
Login at https://piee.eb.mil and search for 'FA480326RC004' to obtain more details.* | - | Solicitation | 07/29/2026 |
Additional Details
Solicitation Number
36C24726Q0027
Archive Date
Sep 1, 2025