GovChime
Notice ID: fd26eac21a2a43e9afa95a8149c0c136Combined Synopsis/Solicitation

N045--Boiler 3 Oxygen Analyzer and Steam Flow Meter

Responses closed . Full description on SAM.gov.

Overview

Response deadline
10:00 AM CDT
Posted
October 22, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of Veterans Affairs

Notice details

Office
247-NETWORK CONTRACT OFFICE 7 (36C247)
Place of performance
Department of Veterans Affairs Carl Vinson VA Medical Center, Dublin, Georgia, 31021
PSC
N045: INSTALLATION OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24727Q0050
Notice ID
fd26eac21a2a43e9afa95a8149c0c136

Description

Questions and Answers 36C24727Q0050 Boiler #3 Oxygen Analyzer and Steam Flow Meter RFI Responses Where should the output signals from the new steam flow meter and O2 analyzer terminate? For example, the existing building automation system (BAS), the existing Boiler 3 burner/boiler controls, or a local display only. Burner 3 boiler/burner controls where applicable and local display. Does the government require active O2 trim control to the burner fuel/air ratio, or monitoring and display of the O2 only? Oxygen analyzer must send signals/information to combustion controls to control trim. What is the material of construction for the stack? Is it single or double wall? Stack is double walled. Inside material is steel; outside material is galvanized steel. Stack is 36 D Selkirk Metalbestos Model P.S. Current operating pressure and temperature of the system for boiler #3? Design pressure is 200 psi. Typical operating pressure is 82 psi. Typical operating temperature is about 330 degrees Fahrenheit. What are the available outputs on the physical steam flow meter (e.g., 4-20 mA, Modbus RTU, BACnet MS/TP)? 4-20 mA analog. Is the flow meter wired directly into an analog terminal block on the CB Hawk, or is it wired directly to the facility s Building Automation System (BMS)? Steam flow meter is wired into local CB Hawk analog terminal block. Please provide nameplates for the existing oxygen analyzer and steam flow meter. Oxygen analyzer nameplate: Steam flow meter nameplate:

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Sheryl Harris
Contract Specialist

Documents

Files (2)

  • 36C24727Q0050 0001_1.docx

    4.7 MBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • 36C24727Q0050.docx

    88 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/Solicitation

    N045--SRVS-SUP Team 1 | Boiler 3 Oxygen Analyzer and Steam Flow Meter | CO: Sheryl Harris; Assn. Date: 09/30/26; EAD: 11/15/26

    Notice fce6c9ad5d7e407e9ea31cb61a6881ac on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationCurrent

    N045--Boiler 3 Oxygen Analyzer and Steam Flow Meter

    Notice fd26eac21a2a43e9afa95a8149c0c136 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C24727Q0050

Archive Date

Jan 24, 2027

Office Address

AUGUSTA, GA, 30904