GovChime
Notice ID: dcb1e79641a24ccb8c55852a78541c99Award NoticeAwarded

Z2DA--Replace Motor Control Center at OPA Basement and Main Building Sub-basement Area (Design Build NRM 672-20-600)

Awarded on September 29, 2021. Full description on SAM.gov.

Awarded tounder 36C24821C0065 (source: SAM.gov award notice)• $3.0M

Overview

Posted
September 29, 2021
Notice type
Award Notice

Notice details

Place of performance
VA Caribbean Healthcare System 10 Calle Casia, San Juan, 00921
Last updated
Dec 4, 2025
Award date
Sep 29, 2021
Award amount (SAM.gov award notice)
$3.0M

Identifiers

Solicitation number
36C24821R0123
Notice ID
dcb1e79641a24ccb8c55852a78541c99
Award number (PIID)
36C24821C0065

Description

Action Code: Pre-Solicitation Notice Date: 06/02/2021 Year: 2021 Contracting Office Zip Code: 00921 Service Code: Z2DA Contracting Office Address: Department of Veterans Affairs, VA Caribbean Healthcare System, Network Contracting Office (NCO) 8 Construction Team 1, 10 Calle Casia, Suite 4M440, San Juan, PR 00921. Subject: Design Build, at the VA Caribbean Healthcare System. Proposed Solicitation Number: 36C24821R0123. Closing Response Date: 07/19/2021. POC for this requirement is Ana G. Alvarado, email: ana.alvarado@va.gov Department of Veterans Affairs Network Contracting Office (NCO) 8 Construction Team 1. This requirement is set-aside for Service-Disabled Veteran-Owned Small Businesses. General Description: The Department of Veteran Affairs (VA), Veterans Integrated Service Network (VISN) 8, VA Caribbean Healthcare System (VACHS) has a requirement to provide all labor, tools, material, and equipment necessary to design and replace the motor control center at OPA Basement and Main Building Sub-Basement Area, VA Caribbean Healthcare System (VACHS), San Juan, PR. This project will replace an existing electrical distribution system that is over 40 years old and needs to be upgraded to serve VACHS facility. These motor control centers have exceeded its life expectancy. This work involves installation of six (6) new Motor Control Centers (MCC) 800 amps minimum capacity at OPA Basement and Main Building. All electrical equipment and components associated with the MCCs shall be furnished by contractor including new conduits and feeders. Disconnection, removal, and disposal of existing MCCs, its components and as well as other abandoned in place equipment. Design and construction of an equipment lift. Provide an analysis of the best location, elevator type and load capacity (minimum 3,000 pounds) to be able to perform the necessary equipment installation and removals. The lift shall comply with all local and federal regulations and shall be protected from weather inclemency. Remove and replacement of existing lighting fixtures on B9. Provide project management including the completion and delivery of all pertinent permits and applications. Provide all testing required for wiring and equipment installation. The NCO 8 anticipates the award of a firm-fixed-price contract to provide the design build services to replace motor control center at OPA Basement and Main Building Sub-Basement Area at the VACHS. The magnitude of construction is between $2,000,000 to $5,000,000. The solicitation will be issued on or about June 16, 2021. All information for this solicitation will be posted on the Beta.SAM.gov website at beta.SAM.gov. All interested firms must be registered in the System for Award Management SAM.GOV. Important Notice: Prior to submitting a proposal under SDVOSB set-aside solicitation, offerors must be listed as verified in the VIP database at https://www.vip.vetbiz.gov

Full description on SAM.gov

Award Overview

Award Number

36C24821C0065

Award Amount (SAM.gov award notice)

$3.0M

Award Date

Sep 29, 2021

Awardee

Awardee UEI

NWJ1Z3M5EAE5

Awardee CAGE Code

5T9Q4

Original Solicitation

Notice ID: dcb1e79641a24ccb8c55852a78541c99

Posted Date: Sep 29, 2021

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C24821N0444
    VENERGY GROUP, LLC
    Department of Veterans AffairsNAICS 236220
    $5.2MSigned Oct 28, 2026
  • 36C25624C0065
    VENERGY GROUP LLC
    Department of Veterans AffairsNAICS 236220
    $3.7MSigned Oct 27, 2026
  • 36C26024C0063
    VENERGY GROUP LLC
    Department of Veterans AffairsNAICS 236220
    $2.2MSigned Oct 20, 2026
  • 36C24819N1141
    VENERGY GROUP, LLC
    Department of Veterans AffairsNAICS 236220
    $18.6MSigned Oct 19, 2026
  • 36C24823C0035
    VENERGY GROUP LLC
    Department of Veterans AffairsNAICS 236220
    $2.6MSigned Oct 13, 2026

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24821R0123
  1. Pre-Solicitation
  2. Solicitation
  3. Awarded

This opportunity has been awarded.

  1. Pre-SolicitationJun 2, 2021

    Z2DA--Replace Motor Control Center at OPA Basement and Main Building Sub-basement Area

    Notice eb2085b96a904dd7ad140c85de087843 on SAM.gov

  2. 2×
    SolicitationJul 16, 2021

    Z2DA--Replace Motor Control Center at OPA Basement and Main Building Sub-basement Area

    Notice 285c5c28181d405da1a53a1e0a04bcd7 on SAM.gov

  3. AwardedCurrentSep 29, 2021

    Z2DA--Replace Motor Control Center at OPA Basement and Main Building Sub-basement Area (Design Build NRM 672-20-600)

    Notice dcb1e79641a24ccb8c55852a78541c99 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

36C24821R0123

Archive Date

Nov 28, 2021

Office Address

TAMPA, FL, 33637