H166--FY23: Air Exchange Pressure Test & Laboratory Hood Certification

Awarded on June 22, 2023. Full description on SAM.gov.

Awarded tounder 36C24823D0089 (source: SAM.gov award notice)• $208.0K

Overview

Posted
June 22, 2023
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS
541380: Testing Laboratories and Services
Agency
Department of Veterans Affairs

Notice details

Place of performance
Department of Veteran Affairs Orlando VA Healthcare System Multiple Locations, Orlando, 32827
Last updated
Dec 4, 2025
Award date
Jun 22, 2023
Award amount (SAM.gov award notice)
$208.0K

Identifiers

Solicitation number
36C24823Q1059
Notice ID
af5fab12c0bd4603bb4f19f01513f9b0
Award number (PIID)
36C24823D0089

Description

Continuation Page The purpose of this amendment is to remove ATTACHMENT D-Lab Hoods Inventory and replace with ATTACHMENT E-Lab Hoods Inventory Revised 06-07-2023.

Full description on SAM.gov

Award Overview

Award Number

36C24823D0089

Award Amount (SAM.gov award notice)

$208.0K

Award Date

Jun 22, 2023

Awardee

Awardee UEI

J69PAKBCKLX3

Awardee CAGE Code

5ANF0

Original Solicitation

Notice ID: af5fab12c0bd4603bb4f19f01513f9b0

Posted Date: Jun 22, 2023

Original Response Deadline: Not specified

Task Orders Under This IDV

Top 10 by total obligated

7
  • 36C24823N0796
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $45.4KSigned Jun 27, 2024
  • 36C24825N0547
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $42.0KSigned May 28, 2025
  • 36C24826N0665
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $42.0KSigned Jun 29, 2026
  • 36C24825N0547
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $41.0KSigned Oct 28, 2026
  • 36C24824N0652
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $39.6KSigned Jun 27, 2024
  • 36C24823N0796
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $39.6KSigned Jun 22, 2023
  • 36C24824N0652
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $39.4KSigned Mar 18, 2026

More From This Vendor

Top 5 most recent

5
  • 36C25022C0037
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $789.5KSigned Oct 30, 2026
  • 36C24825N0547
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $41.0KSigned Oct 28, 2026
  • 36C24426D0086
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    —Signed Oct 20, 2026
  • 36C24426D0087
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    —Signed Oct 20, 2026
  • 36C26320C0158
    WINERGY LLC
    Department of Veterans AffairsNAICS 541380
    $314.1KSigned Oct 5, 2026

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24823Q1059
  1. Pre-Solicitation
  2. Solicitation
  3. Awarded

This opportunity has been awarded.

  1. SolicitationJun 6, 2023

    H166--FY23: Air Exchange Pressure Test & Laboratory Hood Certification

    Notice bfaf61a229824e42966a012c1bdf328e on SAM.gov

  2. Pre-SolicitationJun 6, 2023

    H166--FY23: Air Exchange Pressure Test & Laboratory Hood Certification

    Notice e68653e756164ffa90790197cf5eab9c on SAM.gov

  3. SolicitationJun 7, 2023

    H166--FY23: Air Exchange Pressure Test & Laboratory Hood Certification

    Notice aec72c88c78a4eeeb38fcc8422ef5164 on SAM.gov

  4. AwardedCurrentJun 22, 2023

    H166--FY23: Air Exchange Pressure Test & Laboratory Hood Certification

    Notice af5fab12c0bd4603bb4f19f01513f9b0 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
-AwardedOpen
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made.
-Combined Synopsis11/12/2026
This is a pre-solicitation notice only; do not respond. The Veterans Health Administration (VHA), Network Contracting Office (NCO) 10, requires Sterile Processing Service Water Testing Services for the Marion, Fort Wayne, and Jackie Walorski VA sites in Indiana. The Government intends to publish a 100% set-aside solicitation for Service-Disabled Veteran-Owned Small Businesses on or about 11/25/2026. The solicitation will require the Contractor to furnish a quote providing all information requested in the Instructions to Offerors for Testing Laboratories and Services. The applicable NAICS Code is 541380 Testing Laboratories and Services with a size standard of $19.0 Million. Responses will be evaluated using comparative evaluation under FAR Parts 12 and 13; see solicitation for specific criteria. The resulting award will be a Base with Four Option Years, Firm Fixed Price contract. The closing date for receipt of offers is 12/10/2026 at 01:30 PM ET. All solicitation documents may be downloaded on the date of issuance through Contracting Opportunities via Sam.gov. Any amendments will be posted only on this website. The offeror is responsible for verifying the number of amendments issued. Offerors will have an opportunity to ask questions; details will be provided in the posted solicitation. After the questioning period closes, the Government will post responses to all questions on SAM.gov via a solicitation amendment within 3 business days. Phone calls will not be accepted. No site visit will be held. All offerors shall ensure registration is active, current, and accurate in SAM and includes NAICS code 541380 at the time of RFQ submission through award. Point of Contact: Eric Sweatt, Contract Specialist eric.sweatt@va.gov
-Pre-Solicitation12/10/2026
This is a pre-solicitation notice only; do not respond. The Veterans Health Administration (VHA), Network Contracting Office (NCO) 10, requires Sterile Processing Service Water Testing Services for the Marion, Fort Wayne, and Jackie Walorski VA sites in Indiana. The Government intends to publish a 100% set-aside solicitation for Service-Disabled Veteran-Owned Small Businesses on or about 11/25/2026. The solicitation will require the Contractor to furnish a quote providing all information requested in the Instructions to Offerors for Testing Laboratories and Services. The applicable NAICS Code is 541380 Testing Laboratories and Services with a size standard of $19.0 Million. Responses will be evaluated using comparative evaluation under FAR Parts 12 and 13; see solicitation for specific criteria. The resulting award will be a Base with Four Option Years, Firm Fixed Price contract. The closing date for receipt of offers is 12/10/2026 at 01:30 PM ET. All solicitation documents may be downloaded on the date of issuance through Contracting Opportunities via Sam.gov. Any amendments will be posted only on this website. The offeror is responsible for verifying the number of amendments issued. Offerors will have an opportunity to ask questions; details will be provided in the posted solicitation. After the questioning period closes, the Government will post responses to all questions on SAM.gov via a solicitation amendment within 3 business days. Phone calls will not be accepted. No site visit will be held. All offerors shall ensure registration is active, current, and accurate in SAM and includes NAICS code 541380 at the time of RFQ submission through award. Point of Contact: Eric Sweatt, Contract Specialist eric.sweatt@va.gov
-Pre-Solicitation12/10/2026
Contractor shall provide all labor, supplies, equipment, and supervision necessary to provide Wastewater Effluent Laboratory Analysis Services to the Aleda E. Lutz VA Medical Center described herein. Wastewater Effluent Laboratory Analysis Services include, but are not limited to sample preparation, collection, and storage; transportation of wastewater effluent samples to a laboratory, performance of analytical testing; reporting of analytical test results; and consultative services.