Archived
6530--Ceiling Mounted Patient Lifts 5-North & 5-West
Overview
- Response deadline
- 10:00 AM EDT
- Posted
- April 17, 2025
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 339113: Surgical Appliance and Supplies Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 248-NETWORK CONTRACT OFFICE 8 (36C248)
- Place of performance
- 13000 Bruce B. Downs Blvd,, Tampa, 33612
- Last updated
- Nov 14, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C24825Q0622
- Notice ID
- 1f5083077f8c4aa4b21b75c9fa62311e
Description
STATEMENT OF NEED Ceiling-Mounted Patient Lifts Replacement for 5-North and 5-West Inpatient Units GENERAL: James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for ceiling-mounted patient lifts in two inpatient units to replace outdated patient lifts. The patient lifts will be used for patient transfers and repositioning in bed and will be installed in existing rail systems. BACKGROUND: James A. Haley VA Hospital is soliciting a contractor to furnish all design, site evaluation, labor, materials, equipment, and installation of ceiling-mounted patient care lifts in the existing inpatient units: 5-North and 5-West. Numerous utility systems occupy this space and must be considered when installing new equipment above the ceiling and in the existing patient lift support rails. It is strongly recommended that the contractor perform a thorough site evaluation prior to submitting a proposal. SCOPE: The Contractor shall provide a technical and cost proposal for turn-key services to install ceiling-mounted patient lifts in accordance with this scope of work. This cost proposal shall be for providing new installation and removal/de-installation of LIKO Brand Name Only patient lift units including but not limited to: lift devices, support material, gate transition pieces and all other associated components required for complete, functional installation for ceiling lift in with scale and hand-control based charged ceiling lift systems. This proposal shall also be for installation of the lift systems including but not limited to any required plans, engineering details and documents, tools, labor, testing, training, cleaning supplies, etc. All new lift systems must have a lifting capacity of no less than 507 lbs. Operation of the system must be smooth with no fast or jerky starts and stops. Operation of the system must allow for adequate lifting height allowing for transfer of patient from bed. All lift systems must have the availability to weigh a patient in kilograms and pounds. Existing hangers, Unistrut, or other support components shall not be utilized to support the lift tracks. If additional supports are needed, new supports must be connected directly to building structural components.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
Files (4)
- Download
S06 36C24825Q0622 0001.pdf
835 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
36C24825Q0622 0001_1.docx
18 KBAdded in Combined Synopsis/Solicitation version 3Posted - Download
S02 36C24825Q0622.pdf
702 KBAdded in Combined Synopsis/Solicitation version 1Posted - Download
36C24825Q0622_1.docx
24 KBAdded in Combined Synopsis/Solicitation version 1Posted
Lifecycle
- 1Version 1Combined Synopsis/SolicitationArchived
6530--Ceiling Mounted Patient Lifts 5-North & 5-West
- 3Version 3Combined Synopsis/SolicitationArchivedCurrent
6530--Ceiling Mounted Patient Lifts 5-North & 5-West
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
36C24825Q0622
Archive Date
May 23, 2025
Office Address
TAMPA, FL, 33637