Notice ID: c275258755db42929b858ff82e5ab9aeAward NoticeAwardedArchived
6515--Carto 3 System
Awarded on June 12, 2026. Full description on SAM.gov.
Awarded tounder 36C24826P0527 (source: SAM.gov award notice)• $597.2K
Overview
- Posted
- June 12, 2026
- Notice type
- Award Notice
- NAICS
- 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 248-NETWORK CONTRACT OFFICE 8 (36C248)
- Place of performance
- C.W. Bill Young Veterans Medical Center, Bay Pines, Florida, 33744
- Last updated
- Oct 29, 2026
- First published
- Last updated on SAM.gov
- Award date
- Jun 12, 2026
- Award amount (SAM.gov award notice)
- $597.2K
Identifiers
- Solicitation number
- 36C24826Q0324
- Notice ID
- c275258755db42929b858ff82e5ab9ae
- Award number (PIID)
- 36C24826P0527
Description
Sources Sought Notice Sources Sought Notice Page 4 of 4 Sources Sought Notice Intent To Sole Source *= Required Field Sources Sought Notice Page 1 of 4 This requirement is considered for a sole source award by the contracting officer due to the technical and proprietary nature of the equipment and supporting software that can only be provided by the OEM and/or their authorized representatives. A sources sought was sent out on 2/5/2026 for all small business venders to state if they could provide the equipment and supporting software required to meet this requirement, only one of the few responses that were received for this sources sought provided the information required in accordance with the sources sought. Another consideration for any contract award is price reasonableness which the contracting officer has to make a determination based upon any available pricing information that was discovered during the market research stage of the pre-solicitation process. The contracting officer is under no obligation to award to any small business regardless of their socioeconomic status if the contracting officer based upon market research has determined that the best value to the government would be to award to other than a small business. Please direct any reply if you are interested and can provide the required product/service for this requirement. Please provide your capability statement, letter of supply/ distribution. I will accept responses for this Sources Sought until the 26th of February 2026 14:00, thanks. CARTO® 3 System Base Package and Clinical Module Package, ConfiDense, CartoReplay , PASO , Ripple, VISITAG Surpoint ,Fam DX, Carto PRIME®, CARTO® LAM, CARTO ELEVATE ,CARTSOUND FAM, SPU CARTO® 3 Workstation Cart 22U 600VA 115V CARTO® 3 Workstation Cart Dual Monitor Arm nGEN System (SuperKit - Generator, Pump, and Remote Monitor) Service and Operator Manuals The Contractor shall provide the following documentation for the proposed systems: Two (2) copies of operator instruction manuals (one (1) electronic and one (1) physical copy)Two (2) copies of service manuals (one (1) electronic and one (1) physical copy) Minimum Warranty The system and accessories shall be covered under the manufacturer s warranty and shall include all parts and labor for the agreed upon time between Dexcom and the Bay Pines VAHCS. ****END OF DOCUMENT****
Award Overview
Award Number
36C24826P0527
Award Amount (SAM.gov award notice)
$597.2K
Award Date
Jun 12, 2026
Awardee
Awardee UEI
QB6KPELRH1C7
Awardee CAGE Code
35KQ2
Awardee Address
LAKE MARY, FL 32746, FALKLAND ISLANDS (ISLAS MALVINAS)
Original Solicitation
Notice ID: c275258755db42929b858ff82e5ab9ae
Posted Date: Jun 12, 2026
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $273.9KSigned Sep 9, 2026
- $156.2KSigned Aug 27, 2026
- $301.4KSigned Jun 18, 2026
- $128.4KSigned Feb 3, 2026
- $380.3KSigned Feb 2, 2026
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C24826P0527_1.docx
13 KBAdded in Award Notice version 3Posted
Links (1)
- Department of Veterans Affairswww.va.govPosted
Lifecycle
- 3Version 3Award NoticeArchivedCurrent
6515--Carto 3 System
Other notices for this solicitation
- Market ResearchRelated noticeFeb 5, 2026
6515--Carto 3 System
- Pre-SolicitationRelated noticeFeb 17, 2026
6515--Carto 3 System- Intent To Sole Source
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
This is a SOURCES SOUGHT NOTICE ONLY. It is neither a solicitation nor a request for quote (RFQ) and it does not obligate the Government to award a contract. Request for solicitation will not receive a response. The Government will not pay nor reimburse any costs of preparing responses. This source s sought notice is for market research purposes to make the appropriate acquisition decision and gain knowledge of potential qualified businesses and their Small Business Administration size classification in relation to North America Industry Classification System (NAICS) 334515 Instrument manufacturing for Measuring and Testing Electricity and Electrical Signals with an associated size standard of 1000 employees. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 8 Orlando Contracting Team is seeking to identify interested contractors who can provide Wechsler Memory Scale for the Orlando VA Medical Center (OVAMC). If your business can meet or exceed the requirement, please provide a capability statement. The capability statement shall be limited to no more than five pages and must clearly state the following: Capability in industry to manufacture or provide the required Wechsler Memory Scale. Offerors who cannot provide historical information from their company regarding the outlined attachment or similar scope and scale should provide corresponding information to show how the company would meet the OVAMC requirements. This information should provide level of confidence in the Government that an offeror would meet or exceed the delivery requirements to provide the required Wechsler Memory Scale. Salient Technical Characteristics for the Wechsler Memory Scale System Specifications: The Wechsler Memory Scale Fifth Edition (WMS 5) is a comprehensive adult memory assessment designed for individuals ages 16-90, The Standard Kit includes updated normative data, flexible administration formats (Standard, Short, and Alternate Forms), expanded clinical indices, and paper based scoring. Functional and Performance Characteristics: The Wechsler Memory Scale Fifth Edition (WMS 5) is a comprehensive adult memory assessment designed for individuals ages 16-90, The Standard Kit includes updated normative data, flexible administration formats (Standard, Short, and Alternate Forms), expanded clinical indices, and paper based scoring. Adult Memory Assessment Standardized, individually administered clinical assessment designed to evaluate memory and working memory in individuals aged 16 years through 90 years, 11 months. Comprehensive Memory Evaluation Measures key memory domains including: Auditory Memory Visual Memory Visual Working Memory Immediate Memory Delayed Memory Clinical Index Scores Provides standardized index scores for: Auditory Memory Index (AMI) Visual Memory Index (VMI) Visual Working Memory Index (VWMI) Immediate Memory Index (IMI) Delayed Memory Index (DMI) Multiple Administration Formats Must include comprehensive and abbreviated administration options, consisting of: Standard Form Short Form Alternate Form Memory Screening capability Auditory Memory Measurement Must assess learning, immediate recall, delayed recall, and recognition memory for verbally presented information through narrative and paired-associate memory tasks. Visual Memory Measurement Must assess immediate recall, delayed recall, and recognition of visual stimuli including designs, figures, or equivalent visual memory tasks. Visual Working Memory Measurement Must include standardized measures of visual-spatial working memory and visual sequencing abilities. Normative Database Normative data must be representative of the contemporary U.S. population and stratified by age and demographic characteristics. Digital and Paper Administration Must support paper administration and digital administration/scoring options. Clinical Utility Must provide ancillary, process, and contrast scores that assist in neuropsychological, rehabilitation, clinical, educational, and forensic evaluations. WAIS Compatibility Must allow direct comparison of intelligence and memory performance through compatibility with contemporary Wechsler Adult Intelligence Scale (WAIS) instruments or equivalent cognitive assessment tools. Standardized Scoring and Reporting Must provide standardized scoring procedures, age-based norms, percentile ranks, and interpretive information sufficient for clinical diagnostic use. In addition, provide and answer the following: 1. Company name, address, point(s) of contact, title, telephone number, fax number, email address, cage and SAM UEI number. 2. Company s business size, to include number of employees. 3. Company's socioeconomic status. 4. If SDVOSB/VOSB is planning to provide a response they need to demonstrate the ability to provide a product manufactured by a small business to be considered capable. Submit this information to Contract Specialist, Carl Myers, via email to Carl.myers3@va.gov. Your response to this notice must be received in writing on or before 1:00 PM (Eastern Standard Time) on November 12, 2026. | - | Market Research | 11/12/2026 |
GENERAL: James A. Haley Veterans Hospital (JAHVH) located at 13000 Bruce B Downs Blvd Tampa, Florida 33612, has a requirement for the procurement of a Inhalation Exposure system for use within the Laboratory department. PURPOSE: The Inhalation Exposure system will be used to aerosolize the dioxin Tetrachlorodibenzo-p-dioxin (TCDD) and diesel particulate matter (DPM) for administration to mice. This will allow for a more accurate representation of how military personnel are exposed to these hazards when in the field. SCOPE: James A. Haley Veteran s Hospital is requesting to procure one (1) Inhalation Exposure system with the following characteristics. This also includes Full day On-site Installation and Training and Shipping. PHYSICAL CHARACTERISTICS: Equipment must have physical characteristics to enable the government to perform the capabilities in accordance with the Statement of Need RFQ Responses are due at 12:00PM on 8/19/2026. Questions in response to this solicitation may be emailed to Katrina.tavares@va.gov NO LATER THAN 1:00PM on 8/14/2026. | - | Combined Synopsis | 08/19/2026 |
GENERAL: James A. Haley Veterans Hospital (JAHVH) located at 13000 Bruce B Downs Blvd Tampa, Florida 33612, has a requirement for the procurement of a Inhalation Exposure system for use within the Laboratory department. PURPOSE: The Inhalation Exposure system will be used to aerosolize the dioxin Tetrachlorodibenzo-p-dioxin (TCDD) and diesel particulate matter (DPM) for administration to mice. This will allow for a more accurate representation of how military personnel are exposed to these hazards when in the field. SCOPE: James A. Haley Veteran s Hospital is requesting to procure one (1) Inhalation Exposure system with the following characteristics. This also includes Full day On-site Installation and Training and Shipping. PHYSICAL CHARACTERISTICS: Equipment must have physical characteristics to enable the government to perform the capabilities in accordance with the Statement of Need RFQ Responses are due at 12:00PM on 8/19/2026. Questions in response to this solicitation may be emailed to Katrina.tavares@va.gov NO LATER THAN 1:00PM on 8/14/2026. | - | Combined Synopsis | 08/19/2026 |
This is a combined synopsis/solicitation for commercial products prepared in accordance with the Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) Parts 12 and 15. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0005 is issued as a Request for Proposal (RFP) for NX EQ Ultrasonic Aspirator System: Tissue Ablation and related accessories. This acquisition is set-aside for Service Disabled Veteran Owned Small Business (SDVOSB) concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A PRICE COST SCHEDULE NX EQ Ultrasonic Aspirator System: Tissue Ablation for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide descriptive literature which will be used to determine the extent to which it meets the salient characteristics listed in the Attachment B Product Description. All of the salient characteristics listed in the solicitation must be met to be considered eligible for award. Those proposals which fail to meet all of the salient characteristics will be rated Unacceptable and will be ineligible for award. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract. | - | Combined Synopsis | 12/01/2026 |
| - | Awarded | Open |
Additional Details
Solicitation Number
36C24826Q0324
Archive Date
Jun 27, 2026
Office Address
TAMPA, FL, 33637