GovChime
Notice ID: 4f615fba16454f3dbb7b0e3df103ad89SolicitationArchived

6515--Jax Breast Biopsy System 36C24826Q0893

Archived on September 12, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
4:30 PM EDT
Posted
July 7, 2026
Notice type
Solicitation
NAICS
339112: Surgical and Medical Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
248-NETWORK CONTRACT OFFICE 8 (36C248)
Place of performance
Department of Veterans Affairs North Florida South Georgia VHS, Jacksonville, FL, 32218-3595
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24826Q0893
Notice ID
4f615fba16454f3dbb7b0e3df103ad89

Description

The Department of Veterans Affairs (VA) is seeking a qualified contractor to provide a complete Breast Biopsy System, including all equipment, software, installation, training, and support at the Jacksonville North JOPC, 145 Heron Bay Road, Jacksonville, FL 32218.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Dec 31, 2026

NAICS

339112

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Jeremy C Parrish
Contract Specialist

Documents

Files (2)

  • 36C24826Q0893.docx

    94 KBAdded in Solicitation version 6Posted
    Download
  • 36C24826Q0893_1.docx

    22 KBAdded in Presolicitation version 4Posted
    Download

Lifecycle

  1. 4
    Version 4PresolicitationArchived

    6515--Jax Breast Biopsy System 36C24826Q0893

    Notice 5f365c2d5088439d9c5682b72f59f085 on SAM.gov

  2. 6
    Version 6SolicitationArchivedCurrent

    Type changed from Presolicitation to Solicitation

    6515--Jax Breast Biopsy System 36C24826Q0893

    Notice 4f615fba16454f3dbb7b0e3df103ad89 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Good day, SDVOSB s, VOSB s & SB's Sources Sought INTENT TO SOLE SOURCE Pre-Solicitation. This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs VOSBs , or SBs . This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks. 1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744 is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer. 2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care. 2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays. 3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment. 4.Period of Performance: The product is requested to be delivered no later than December 19th. 5.Type of Contract: Supply: Firm, Fixed Price. 6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below. 6.1 Salient Characteristics NAME BRAND - Equipment Requirement: GE Healthcare QTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer QTY. 6 (P/N: UA2511) Reprocessing Trays for E14C4T Equipment Requirement: Minimum Required Features and Specifications Type / Intended Use: Must be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications. Must provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes. Frequency & Imaging Performance: Must operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate. Must support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system). Biopsy and Procedural Capability: Must include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange. Must accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments. Must permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures. 4. Design & Ergonomics Must be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use. Must include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle. Must be designed for one-handed operation and compatible with sterile probe covers. 5. Compatibility Must be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms. Must connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters. 6. Cleaning & Sterilization Must be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes. Must be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide. 7. Construction & Safety Must be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards). Must comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits. Must be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use. Summary Table Feature Category Requirement Type Triplane transrectal prostate ultrasound transducer Frequency 4 14 MHz Imaging Modes B, M, Color Doppler, Power Doppler (Elastography optional) Biopsy Capability Integrated dual-plane biopsy guide Needle Compatibility 17 18 G Operation One-handed, Smart Button on probe Sterilization Fully immersible, high-level disinfectable Compatibility bk3000, bk5000, bkActiv, bkSpecto Intended Use Prostate imaging and biopsy guidance Condition New OEM product, OEM warranty
-Market Research11/16/2026
DESCRIPTION: The VA Healthcare System (VAHCS) at Bay Pines, Florida, intends to award on a Sole Source basis. Seeks to procure Penumbra Lightning Flash intelligent aspiration catheters to support mechanical thrombectomy (clot removal) procedures performed by Bay Pines VAHCS providers. These single-use, FDA-cleared endovascular aspiration catheters are used to remove thrombus (blood clots) from vessels during emergent and scheduled vascular procedures, including the treatment of acute vascular occlusion. The catheters operate in conjunction with the facility's existing Penumbra System, including the ENGINE aspiration pump and associated aspiration tubing. This procurement will aid in the prompt, safe, and effective treatment of Veterans requiring thrombectomy. This is a one-time supply purchase. The proposed source is USVETSERV LLC., Greenville, SC. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES; however, any firm that believes it can meet the requirements may give written notification prior to the response due date and time. The proposed NAICS 339112 is applicable to this acquisition; with a size standard of 1,000 employees. Parties may identify their interest, accompanied by supporting documentation to the Contracting Officer no later than 10/23/2026 at 4:30PM EST. Responses should be sent to yolanda.glover@va.gov. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement will be solely up to the government.
-Market Research10/23/2026
This is a Sources Sought Notice only. It is neither a solicitation nor a request for a quote and it does not obligate the Government to award a contract. Requests for solicitations will not receive a response. The Government will not pay nor reimburse any costs of preparing of a response. The purpose of this notice is for market research purposes only, to make an appropriate acquisition decision, to gain knowledge of potential interested and qualified businesses, and any Small Business Administration (SBA) size classification in relation to North American Industry Classification System (NAICS) code 339112 Surgical and Medical Instrument Manufacturing, with a size standard of 1,000 employees. The Network Contracting Office (NCO) 8 is seeking a business to provide Brand Name or Equal, De Soutter Medical MBC Sternudrive LiteTM; Model MBC 709-Modular: to the VA Medical Facility, VA Caribbean Healthcare System. Businesses may respond by submitting a qualifications letter including the following information: Company Name, Address, Point of Contact, Phone Number, Email, Unique Entity Identifier Code, Socio-Economic Category (i.e., SDVOSB, VOSB, HUBZone, etc.), Federal Supply Schedule Contract Number if applicable, and a capability statement to the requirement. Provide evidence your business can provide the requested items to include past/and or current contracts for the same requirement, and any other compelling evidence to help the Government determine your company s capabilities. NOTE: The following list includes instruments for a MBC Sternudrive LiteTM, model MBC 709-modular, manufactured by DeSoutter Medical. We are requesting information for an EQUAL product with the preference at this time for domestic products. The domestic product must meet or exceed the salient characteristics provided as follows: Item Number Description Quantity Unit of Issue 0001 Model MBC 709-Modular handpiece Cannulation 4.4 mm 1291554 3 EA 0002 Reciprocating Sternum Saw 18380 3 EA 0003 Sternum guard 3 EA 0004 Oscillating sagittal sternum saw 3 EA 0005 Battery Pack Large 4 EA 0006 Sterilization System 3 EA To be eligible for award, prospective offerors must be registered in the System for Award Management (SAM) Internet site, https://sam.gov/content/home. Responses to this Sources Sought Notice must be sent to darrin.alexander2@va.gov no later than November 12, 2026, at 13:00 Hours Eastern Standard Time. Note: Telephone and facsimile responses will not be considered. Questions and discussion will not be considered. When responding via email, ensure the subject line is titled with RFI# 36C24827Q0095 FY 26: MBC Sternudrive LiteTM; Model MBC 709-Modular. Thank you for your interest and time.
-Market Research11/12/2026
DESCRIPTION: Department Of Veterans Affairs, VISN8, Network Contracting Office 8, Prosthetics Department, Tampa, FL, hereby Gives Notice of Intent to Award a Sole Source to Cagent Vascular Inc, 50 Strafford Avenue Suite 315, Wayne, Pa 19087. DELIVERABLES: The Serranator® PTA Serration Balloon Catheter is a peripheral angioplasty device from Cagent Vascular designed for the treatment of peripheral artery disease (PAD) and certain arteriovenous (AV) fistula lesions. Unlike a standard PTA balloon, it incorporates serrated scoring elements on the balloon surface that create controlled micro-incisions (micro-fissures) in the vessel wall during inflation. This approach is intended to improve lumen expansion while reducing recoil and uncontrolled dissections. [cagentvascular.com], [cagentvascular.com] KEY FEATURES Serration Remodeling Therapy (SRT) technology. Semi-compliant balloon with embedded serrated metal elements. Designed to generate focused point force rather than uniform circumferential stretching. Available in multiple balloon diameters and lengths for peripheral interventions. [cagentvascular.com], [fda.innolitics.com] THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. The North American Industry Classification System (NAICS) number is 339113. A decision by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct competitive procurement. Parties may identify their interest, accompanied by supporting literature to the Contracting Officer no later than 11/11/2026 at 12:00 PM EST. Responses should be sent to shirley.courtney@va.gov. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement will be solely up to the government.
-Special Notice11/11/2026
This is a Sources Sought Notice Only. It is neither a solicitation nor a Request for Quote (RFQ) and it does not obligate the Government to award a contract. Requests for quote will not receive a response. The Government will reimburse any costs associated with preparing a response to this notice. The purpose of this Sources Sought Notice is to conduct market research, identified potential qualified vendors and determine their Small Business Administration (SBA) size classification under North American Industry Classification System 339113, Surgical Appliance and Supplies Manufacturing (size standard: 800 employees). The Department of Veterans Affairs, Network Contracting Office (NCO 8), is seeking sources capable of providing Edwards SAPIEN 3 Ultra Resilia Transcatheter Heart Valve (THV) with Commander System in 23mm, 26mm, 29mm, 20mm, and Pascal Precision System Mitral/PASCAL ACE Implant System for the Veteran Integrative Service Network (VISN 8) as consignment agreement delivery method under an Indefinite Delivery Indefinite Quantity contract. Concerns may respond by submitting a qualifications letter including the following information: Company Name Company Address Point of Contact Phone, Fax, and Email System for Award Management (SAM) Unique Entity Identifier (UEI) Code Capability Statement specific to the technical requirements and include product brochure, if possible. Provide evidence that your firm can provide the requested items, including past and/or current contracts for the same requirements, and any other compelling evidence to help the Government determine your company s capabilities. To be eligible for an award, prospective offerors must be registered in the System for Award Management (SAM) at: www.sam.gov/content/home. Responses to this notice shall be submitted via email no later than 12:00 PM Eastern Standard Time on October 8, 2026. Telephone and facsimile responses will not be accepted. Please email your response to: Jessica.Kiser@va.gov. Email Subject Line: Sources Sought Notice-36C24827Q0033- VISN 8 Heart Valves No further information is available at this time. The Government appreciates your interest and the time invest in preparing and submitting your response.
-Market Research10/08/2026

Additional Details

Solicitation Number

36C24826Q0893

Archive Date

Sep 12, 2026

Office Address

TAMPA, FL, 33637