GovChime
Notice ID: a5a5ea83e78a4f5e930c6c9d9bda956dAward NoticeAwarded

J065--CryoConsole PM & Repair Service Lexington VA Medical Center

Awarded on October 1, 2023. Full description on SAM.gov.

Awarded tounder 36C24924P0019 (source: SAM.gov award notice)• $47.3K

Overview

Posted
October 2, 2023
Notice type
Award Notice
NAICS
811210: Electronic and Precision Equipment Repair and Maintenance
Agency
Department of Veterans Affairs

Notice details

Last updated
Dec 4, 2025
Award date
Oct 1, 2023
Award amount (SAM.gov award notice)
$47.3K

Identifiers

Solicitation number
36C24924Q0005
Notice ID
a5a5ea83e78a4f5e930c6c9d9bda956d
Award number (PIID)
36C24924P0019

Description

Special Notice 36C24924Q0005 The Department of Veterans Affairs, Network Contracting Office 09, hereby provides notice of its Intent to award a Sole Source, firm fixed price contract CryoConsole Preventative Maintenance & Repair Service to a large business Medtronic USA Inc., located at 8200 Coral Sea Street Mounds View, MN, 55112 for the Lexington VA Health Care System, 1101 Veterans Drive, Lexington, KY 40502. The total value of the award is $78,750.00, determined fair and reasonable by the Contracting Officer based on the current commercial price list available to the public. The anticipated award date is 10/01/2023. FAR 6.302-1 Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements, applies to this procurement." The contract is expected to be awarded under the authority of 41 U.S.C. 3304(a)(1), as implemented by FAR 13.106-1(b) Soliciting from a Single Source. A Justification for Single Source Awards for Other Than Full and Open Competition has been prepared as there is only one identified responsible source, and no other services will satisfy agency requirements. NAICS code: 811210 Electronic and Precision Equipment Repair and Maintenance SBA Size Standard: $34M PSC: J065 Maint/repair/rebuild Of Equipment- Medical, Dental, and Veterinary Equipment and Supplies Statement of Work Service Contract on Medtronic Cryoconsole I. Equipment Equipment to be serviced/maintained includes: Medtronic Cryoconsole, EE 103040, S/N 5M1167 Equipment is located at 1101 Veterans Drive, Lexington, KY 40502. Period of performance is as follows: Base Year: 10/1/2023-9/30/2024 Option Year 1: 10/1/2024-9/30/2025 Option Year 2: 10/1/2025-9/30/2026 Option Year 3: 10/1/2026-9/30/2027 Option Year 4: 10/1/2027-9/30/2028 II. Scope of Services Includes one (1) on-site field service preventative maintenance visit Includes on-site priority field service repair visits Includes labor, parts, materials, travel expenses, and ancillary costs required for the equipment service Includes unlimited technical phone support and error correction Includes phone clinical application support, Monday-Friday, 8:30am-5:30pm EST, with on-call hours of 7:00-8:30am and 5:30pm-1:00am EST All charges for parts, services, manuals, tools, or software required to successfully complete scheduled and unscheduled services are included within this contract. The Medical Center shall not provide any parts, manuals, tools, or software to the Contractor, and all equipment documentation, including operator and service manuals, parts lists, and schematics shall be readily provided to the Contracting Officer (CO) upon request. All replacement parts furnished shall be new original equipment manufacturer (OEM). The Contractor shall not modify the system to facilitate replacement parts which are not identical to the part being replaced, unless such modification was developed, approved, and released by the OEM. Any used or replaced parts shall remain the property of this Medical Center unless released to the Contractor by the Contracting Officer s Representative (COR). Any charges outside the scope of this contract must be approved by the COR prior to performing service. III. Conformance Standards and Condition of Equipment The Contractor shall ensure that the equipment functions in conformance with manufacturer specifications and the latest published editions of NFPA-99 and OSHA. This includes performance standards and specifications used when the equipment was procured and any upgrades/updates thereafter. Test equipment shall be within manufacturer specifications and calibrated at required intervals. Calibrations shall be traceable to a national standard. Any test equipment calibration certificates shall be provided to the CO and COR upon request. The Contractor accepts responsibility for the equipment described above in as is condition. Failure to inspect the equipment prior to contract award will not relieve the contractor from performance of the requirements of this contract. The Contractor shall immediately, but not later than 24 consecutive hours after discovery, notify the CO and COR in writing of the existence or the development of any defects in or repairs required to the above equipment which the Contractor considers out of scope under the terms of this contract. The Contractor shall furnish the CO and COR with a written cost estimate of the necessary repairs. IV. Hours of Coverage Normal hours of coverage are Monday-Friday, 8:00am to 5:00pm (EST), excluding national holidays recognized by the Department of Veterans Affairs. All services will be performed during normal hours of coverage unless requested and approved by the COR. Observed holidays include: New Year s Day Labor Day Martin Luther King Day Columbus Day President s Day Veterans Day Memorial Day Thanksgiving Day Juneteenth Independence Day Christmas Day Independence Day And any other federal holidays as designated by the President. Work performed outside the normal hours of coverage at the request of the COR will be billed at the Contractor s applicable rate, unless after-hours services are included in the Scope of Work. Work performance outside the normal hours of coverage at the request of the Contractor will be considered normal hours. There shall be no additional charge for time spent on-site during or after normal hours of coverage awaiting the arrival of additional FSE, finishing any maintenance services, and/or delivery of parts. V. Scheduled Maintenance All preventative maintenance (PM) services shall be completed in accordance with Manufacturer s requirements and recommendations. A PM inspection shall include, at a minimum, the following: Cleaning and calibration of equipment Review of operating system and software application diagnostics and correction Remedial maintenance and lubrication Inspection and testing of all system components, hardware, electrical wiring and cables, and peripherals Replacement of all worn and fault components, hardware, electrical wiring and cables and peripherals, including any of the above which are likely to become worn, faulty, or fail Returning the equipment to Manufacturer operational condition, as defined in Conformance Standards. Providing electronic documentation of all services performed to the end user, COR, and Biomedical Engineering VI. Unscheduled Maintenance All repair services shall be completed in accordance with Manufacturer s requirements and recommendations, as well as the Conformance Standards. The Contractor shall provide full service of diagnosis and remediation to maintain the equipment in operational condition. Repair services may consist of troubleshooting, replacing failed components, calibration, cleaning, adjustments, and in situations of severe malfunctions that cannot be repaired, replacement of the unit. All services performed shall be electronically documented and provided to the end user, COR, and Biomedical Engineering. The Contractor shall provide a response to a service request within (1) hour of notification during office and on-call hours. If on-site service is necessary, the field service engineer (FSE) shall investigate and repair within 2 business days from the time diagnosis is established by Contractor, unless the VA and Contractor agree upon a different time. The Contractor must show satisfactory evidence to the VA that efforts and manpower are progressing to troubleshoot failure and identify a solution in a timely manner. If the Contractor fails to meet the on-site response time to begin performing work, or if downtime exceeds 16 consecutive hours after on-site arrival by the FSE, the VA reserves the right to obtain repair services from another source at the Contractor s expense. The decision to exercise the alternative repair will reside exclusively with the CO. VII. Sign-In and Documentation: During normal hours of coverage, the Contractor, shall enter their signature on the sign-in sheet and receive a temporary ID badge in the Engineering Office, Room D232, second floor of the Main Building. Upon departure, the Contractor shall sign-out on the same sheet, return the ID badge, and leave any hard-copy documentation in D234. During non-normal hours, the Contractor shall sign-in with the Police Service, C101 Main Building, upon arrival and departure. The ID badge must always be displayed while on the premises of the Medical Center. It is the responsibility of the Contractor to park in the appropriate designated parking areas. Information on parking is available from the Police Service. The Medical Center will not invalidate or make reimbursement for parking violations of the Contractor under any conditions. Smoking is prohibited inside any buildings at the Medical Center. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in a citation answerable in the United States (Federal) District Court, not a local district, state, or municipal court. Documentation shall include detailed descriptions of the scheduled and unscheduled maintenance procedures performed. Procedures used for PM inspections shall be submitted with each report. The Contractor shall, at a minimum, thoroughly record the following items: Name of Contractor Name of FSE who performed the service Date and time during which services were rendered VA PO#(s) associated with the services Description of problem reported Identification of equipment to be serviced, including model number, serial number, and any other identifying information Itemized description of services performed (including costs of items to be billed) Total cost to be billed Signatures of FSE and VA employee who witnessed service VIII. Competency of Personnel Service Equipment The Contractor shall have an established business with a full-time staff, including a fully qualified FSE and backup fully qualified FSE. Fully qualified is based upon training and field experience. All personnel servicing equipment under this contract must have been factory trained by the OEM and have completed a minimum of (2) years of field work. The FSEs shall be authorized by the Contractor and OEM to perform services on the above equipment. Training documentation and related certifications shall be provided to the CO and COR upon request. The CO and COR reserve the right to reject any personnel and refuse them permission to work on the above equipment. IX. Security and Privacy of VA Sensitive Information The C&A requirements do not apply and a Security Accreditation Package is not required. All media (hard drives, DVD s, Floppies, etc.) that contains sensitive data must be surrendered to the Medical Center (Biomedical Engineering) and may not leave VA property. All Contractor-owned media (USB drives, DVD s, CD s, Floppy disk) that is to be inserted into a medical device must be scanned by Biomedical Engineering prior to being placed in the medical device. (End of Statement of Work) THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, interested parties may identify their interest and capability to respond to this requirement within seven calendar days after publication of this notice. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government. Information received will normally be considered solely for determining whether to conduct a competitive procurement. The Department of Veterans Affairs will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses will be considered. All responses from responsible sources will be fully considered. As a result of analyzing responses to this notice of intent, the Government shall determine if a solicitation will be issued. Any prospective contractor must be registered in the System for Award Management (SAM) to be eligible for award and must submit a current authorized distributor letter from the manufacturer. All Service-Disabled Veteran Owned and Veteran Owned Small Businesses must submit a self-certifying statement indicating compliance with the Limitation on Subcontracting criteria established in accordance with VAAR 852.219-77 . Interested parties are encouraged to furnish information by email only with RESPONSE TO INTENT TO SOLE SOURCE 36C24924Q0005 in the subject line. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Lara Hampton, Contract Specialist, by email at Lara.Hampton@va.gov NO LATER THAN Aug 21, 2023 @ 10:00AM CST. The capability documentation should include general information and technical background describing in detail the prospective contractor's capabilities and experience that will demonstrate the ability to support these requirements. ~END~

Full description on SAM.gov

Award Overview

Award Number

36C24924P0019

Award Amount (SAM.gov award notice)

$47.3K

Award Date

Oct 1, 2023

Awardee

Awardee UEI

GPRGARK3K6L8

Awardee CAGE Code

77HM9

Original Solicitation

Notice ID: a5a5ea83e78a4f5e930c6c9d9bda956d

Posted Date: Oct 2, 2023

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C25926P0002
    MEDTRONIC USA INC
    Department of Veterans AffairsNAICS 811210
    —Signed Oct 27, 2026
  • 36C24426P0399
    MEDTRONIC USA INC
    Department of Veterans AffairsNAICS 811210
    $53.5KSigned Oct 15, 2026
  • 36C26224C0011
    MEDTRONIC USA INC
    Department of Veterans AffairsNAICS 811210
    $572.2KSigned Oct 8, 2026
  • 36C25025P0038
    MEDTRONIC USA INC
    Department of Veterans AffairsNAICS 811210
    $67.3KSigned Oct 1, 2026
  • 36C25925P0040
    MEDTRONIC USA INC
    Department of Veterans AffairsNAICS 811210
    $16.9KSigned Oct 1, 2026

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C24924Q0005
  1. Awarded

This opportunity has been awarded.

  1. 2×
    Special NoticeAug 11, 2023

    J065--CryoConsole PM & Repair Service** INTENT TO SOLE SOURCE** Lexington VAMC

    Notice 1703a2d1ed014076964fcabc07785598 on SAM.gov

  2. AwardedCurrentOct 2, 2023

    J065--CryoConsole PM & Repair Service Lexington VA Medical Center

    Notice a5a5ea83e78a4f5e930c6c9d9bda956d on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
-AwardedOpen
ALCON CONSTELLATION LXT PHACOEMULSIFICATION UNITS AND EMBEDDED LASERS PMI SERVICES
-Combined Synopsis11/27/2026
This is a Sources Sought Notice only. This Sources Sought Notice is not a request for competitive quotes and no solicitation is available. All interested parties must respond to the Sources Sought Notice in writing. See the attached Sources Sought Notice Document. 1. The purpose of this notice is to determine if there are interested contractors that are capable of providing Cryogenic Tank Preventive Maintenance Services for New Mexico Healthcare System located at 1501 San Pedro Dr SE, Albuquerque, NM 87108. 2. The Draft Statement of Work included in this Sources Sought Notice is not final. No inquiries will be accepted at this time. Responses must be submitted via email only to Contract Specialist: Andrew Longworth at Andrew.longworth@va.gov no later than 3:00 PM Pacific Time, November 12, 2026. 3. Intent to sole source: if no responses are received that indicate interested and capable vendors, the Government intends to issue a sole source award to Scientific Resources Southwest, who has previously provided these services to VA New Mexico Healthcare System.
-Market Research11/12/2026
The Department of Veterans Affairs is conducting market research to identify qualified and capable business concerns that can provide surgical and clinical instrumentation maintenance and repair services for the VA Northeast Ohio Healthcare System. The Government is particularly interested in determining whether two or more verified Service-Disabled Veteran-Owned Small Business (SDVOSB) and/or Veteran-Owned Small Business (VOSB) concerns are capable of meeting the requirement at fair and reasonable prices. The results of this market research will be used to inform the acquisition strategy. No set-aside decision has been made by issuance of this notice. The contractor shall provide on-site and off-site preventive maintenance, sharpening, repair, renewal, and, when authorized, replacement support for surgical and clinical instrumentation, surgical case carts, and surgical sterilization containers. Services will support the Louis Stokes Cleveland VA Medical Center, including Wade Park operating room, clinics, and the Outpatient Surgery Center. Provide weekly on-site services during normal operating hours, Monday through Friday, 7:00 a.m. to 3:30 p.m. Eastern Time, excluding Federal holidays. Perform approximately 80 percent of the workload within a mobile laboratory and approximately 20 percent at an off-site laboratory when on-site repair is not possible. Provide preventive maintenance and specialty repairs for ophthalmic, cardiac, vascular, ENT micro-instruments, laparoscopic instruments, scopes/laryngoscopy devices, large retractor systems, power surgical instruments, and general surgical instrumentation. Repair case carts and sterilization containers as needed using original equipment manufacturer parts. Provide a list of trays scheduled for maintenance at least 48 hours before service and communicate the trays actually serviced. Segregate instruments that cannot be repaired, clearly mark them as not for patient use, and deliver them to Sterile Processing Service management. Provide same-day quality assurance documentation identifying sets serviced, repairs completed, instrument condition observations, and items removed for off-site repair. Participate in quarterly performance reviews with Sterile Processing Service leadership. Follow applicable FDA, CMS, CDC, AAMI, AORN, APIC, HSPA, VA security, medical-device protection, infection-control, and personal protective equipment requirements. Anticipated Period of Performance: (12) months from the date of award. Sterile Processing Service, Rooms 117 and 122, Louis Stokes Cleveland VA Medical Center, 10701 East Boulevard, Cleveland, OH 44106 Outpatient Surgery Center, 8901 Superior Avenue, Cleveland, OH 44106
-Market Research11/13/2026
FY27: Replacement Dental Vacuum Pump System
-Solicitation11/16/2026

Additional Details

Solicitation Number

36C24924Q0005

Archive Date

Nov 1, 2023

Office Address

MURFREESBORO, TN, 37129