GovChime
Notice ID: 89cbaf921706442d8cc2684dd3d5662eSolicitationArchived

Annual Medical Gas Inspection & Training

Archived on November 14, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM EDT
Posted
November 5, 2025
Notice type
Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
541380: Testing Laboratories and Services
Agency
Department of Veterans Affairs

Notice details

Office
249-NETWORK CONTRACT OFFICE 9 (36C249)
Place of performance
Tennessee, 37212
Last updated
Nov 6, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24926Q0013
Notice ID
89cbaf921706442d8cc2684dd3d5662e

Description

Provide Annual Medical Gas Inspection & Training

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Vendor

MGI, INC.

Contract end date

Nov 3, 2026

NAICS

541380

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Documents

Files (3)

  • C01-Award Notice- 36C24926P0082_1.pdf

    56 KBAdded in Solicitation version 4Posted
    Download
  • S06-36C24926Q0013 0001.pdf

    133 KBAdded in Solicitation version 2Posted
    Download
  • S02-36C24926Q0013 -Medical Gas Inspection _Training.pdf

    665 KBAdded in Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1SolicitationArchived

    Annual Medical Gas Inspection & Training

    Notice b674e2a74d424cb1ae64195ffe8907e5 on SAM.gov

  2. 2
    Version 2SolicitationArchived

    Annual Medical Gas Inspection & Training

    Notice 8facd74523ab4a3c8aa9a46800e8ffdb on SAM.gov

  3. 4
    Version 4SolicitationArchivedCurrent

    Annual Medical Gas Inspection & Training

    Notice 89cbaf921706442d8cc2684dd3d5662e on SAM.gov

Other notices for this solicitation

  1. AwardedRelated noticeNov 5, 2025

    H946--36C249-26-AP-0560 - Medical Gas Inspection & Certification - Engineering

    Notice e2059efa001e4b19b5194d8b8034b94c on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made.
67%
Combined Synopsis11/12/2026
59%
AwardedOpen
Tri-Annual Electrical Inspection IAW the Performance Work Statement. Total Small Business Set-Aside, Quotes are due on 11/20/2026 at 16:00 (4pm) PST. Amendment 0001 – The purpose of this amendment is to respond to questions received in response to the original solicitation. Attachment 4 and 5 have been added to this solicitation as requested. The due date for quotes has not been extended and remains 11/20/2026 at 16:00 PST.
57%
Combined Synopsis11/20/2026
Tri-Annual Electrical Inspection IAW the Performance Work Statement. Total Small Business Set-Aside, Quotes are due on 11/20/2026 at 16:00 (4pm) PST.
57%
Combined Synopsis11/20/2026
Description:Â The Richard L. Roudebush VA Medical Center has a requirement to inspect and test the boiler controls for three hot water condensing boilers. Two of the boilers are located in new Building 5 on the Richard L. Roudebush Campus, 1481 W 10th Street, Indianapolis, IN 46202 and the third boiler is located at the Vet s House on the Cold Springs Road Campus, 2669 Cold Springs Road, Indianapolis, IN 46222. The intent of this work is to provide a complete, device level inspection and testing program for the facilities hot water boilers with documentation sufficient for the VA, Joint Commission, NFPA, and Authority Having Jurisdiction (AHJ) review. A firm-fixed price service contract with a 1-year base period and four 1-year option periods is anticipated. The base period of performance is anticipated to be December 22, 2026 December 21, 2027, with the ultimate completion date anticipated to be December 21, 2031, inclusive of all option periods. Â This procurement is 100% set aside for Service-Disabled, Veteran-Owned Small Business (SDVOSB) concerns. Â At the time of submission of offers/quotes, and at the time of award of any contract, the offeror must represent to the contracting officer that it is a small business concern under the North American Industry Classification System (NAICS) code assigned to the acquisition. The offeror must also be certified as a Service-Disabled, Veteran-Owned Small Business with the Small Business Administration (SBA). Offers from other than SDVOSB concerns will not be considered and shall be rejected. The VA plans to issue a solicitation on or about November 2, 2026, using the procedures in RFO Part 12, with an anticipated award date prior to December 22, 2026. All responsible sources may submit a quotation, which will be considered by the agency. The solicitation and all appliable information, drawings, and specifications will be published electronically at no cost. Â ***End of Pre-Solicitation Notice***
57%
Pre-Solicitation10/31/2026

Additional Details

Solicitation Number

36C24926Q0013

Archive Date

Nov 14, 2025

Office Address