GovChime
Notice ID: 134c535c362e4556801d9edcf83f7e04Special NoticeArchived

6525--621-26-3-091-0130 - CT Injectors - Logistics

Archived on July 31, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:00 AM EDT
Posted
June 12, 2026
Notice type
Special Notice
NAICS
339112: Surgical and Medical Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
249-NETWORK CONTRACT OFFICE 9 (36C249)
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C24926Q0263
Notice ID
134c535c362e4556801d9edcf83f7e04

Description

Special Notice Page 1 of Special Notice Page 4 of 4 Special Notice *= Required Field Special Notice Intent to Sole Source - Bayer HealthCare LLC SPECIAL NOTICE: 36C24926Q0263 The Department of Veterans Affairs intends to issue a sole-source firm-fixed priced contract to Bayer HealthCare LLC, 1 Bayer Drive, Indianola, PA 15051. In accordance with Federal Acquisition Regulation (FAR) 12.102 (a) and on behalf of the James H. Quillen VAMC, Network Contracting Office (NCO) 9 intends to issue a sole source firm-fixed priced contract to Bayer HealthCare LLC, 1 Bayer Drive, Indianola, PA 15051. The rationale basis for the sole source acquisition is that Bayer HealthCare LLC is the only source capable of providing the government with a Brand Name or Equal contract for the Medrad Centargo CT Injection Systems. Contractor will provide CT Contrast Injection Systems that are brand name or equal to the Medrad Centargo CT Injection System. The government anticipates awarding a purchase order contract for the CT Injection Systems. Bayer HealthCare LLC is the only responsible distributor of the Medrad Centargo CT Injection Systems. The North American Industry Classification System (NAICS) for this requirement is, 339112 - Product of Service Code for this requirement is 6525. The Small Business Administration (SBA) size standard for this sector is 1,000 employees. Background. The James H. Quillen VAMC Radiology Department has a brand-name requirement for the purchase and installation of the Centargo Dual Injector multi-patient, dual-syringe contrast media delivery system that is compatible with the hospital s existing Philips CT Scanner. The CT Contrast Injection Systems must be comparable with the James H. Quillen VAMC s current Philips CT Scanner. System must be multi-patient / extended-use bulk contrast delivery workflow and the contrast configuration must eliminate the dependence on proprietary pre-filled syringes to support the high-throughput CT environments where continuous, uninterrupted injector availability is essential to patient care operations. System must have advanced patient safety safeguards and incorporates independent air detection and real-time pressure monitoring, which are required safety features for the clinical environment at this facility. The injection system must be validated and approved under the June 2026 VistA Imaging Approved DICOM Modality Interfaces listing, confirming that the system: communicates with VistA Imaging in accordance with VA-established DICOM standards; has completed VA interface validation and testing; and is authorized for deployment in VA clinical environments without additional interface testing, integration risk, or IT remediation. System must have touchscreen programmable protocol management that allows technologists to configure, store, and execute contrast injection protocols directly at the scanner workstation, reducing manual error and supporting complex multi-protocol CT operations. Each injector system must operate independently to ensure operational continuity across multiple CT suites without cross-system dependency or downtime risk. The vendor is required to provide delivery, installation, configuration, functional testing, and training of clinical staff. ITEM INFORMATION/REQUIREMENTS Estimated quantities: Item Number Part Number Description Quantity Each 0001 CENT SYS BAT Bayer MEDRAD Centargo CT Injection System 3 0002 ESW-CENT-CSC Essential SW Svc Plan Cust Config, CENT Solution Plan 6 0003 INS CENT Installation Centargo - INS CENT 3 0004 86950308 Annual Subscribe Dictation Int SW 6 0005 Shipping and Handling 1 Other important considerations: Response to this announcement shall not to exceed 10 pages and should include the following information: (1) A tailored capability statement indicating the firm s ability to provide a product and related services; (2) The respondents DUNS number, organization name, address, point of contact, and size and type of business (e.g., SDVOSB/VOSB, etc.) pursuant to the applicable NAICS code; (3) Information should be provided electronically in a Microsoft Word or Adobe PDF format. This notice of intent is not a request for competitive quotes. However, interested parties may identify their interest and capability to respond to the requirement and submit capability statement no later than 11:00 am., EST, Wednesday, July 01, 2026, to: larry.olive@va.gov. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement based upon responses received to this notice is solely within the discretion of the Government. If no written response is received within the closing date of this notice, a sole source award will be made to Bayer HealthCare LLC. without any further notice. Disclaimer and Important Notes: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response to this notice. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. However, responses to this notice will not be considered adequate responses to a notice.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Larry Olive
Contracts Specialist

Documents

Files (3)

  • VistA Imaging Approved DICOM.pdf

    432 KBAdded in Special Notice version 3Posted
    Download
  • P03 - SSJ - Dual CT Injector System 2.pdf

    160 KBAdded in Special Notice version 3Posted
    Download
  • 36C24926Q0263.docx

    22 KBAdded in Special Notice version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Special NoticeArchivedCurrent

    6525--621-26-3-091-0130 - CT Injectors - Logistics

    Notice 134c535c362e4556801d9edcf83f7e04 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
TRIOS 5 Wireless Intraoral Scanners and Workstations for the James H. Quillen VA Medical Center.
-AwardedOpen
This market research notice is being conducted by Network Contracting Office (NCO) 17 VHA Regional Procurement Office-West (RPOW) 5441 Babcock Road Medical Center, 302 San Antonio TX 78240 for the procurement for the Multilab Series II Roorda Vascular System W/DICOM, integration capabilities for San Antoino Veterans Health Care System VA, TX 78229 Background and Requirement: San Antiona Veteran Healthcare System, 7400 Merton Minter, San Antonio, Tx 78229 is seeking a Multilabel Series II Roodra Vascular System W/DICOM. The purpose of this procurement is to acquire, deliver, install, test, and deploy four (4) Multilabel Series II Roodra Vascular Systems with DICOM integration capabilities. The required system is the Unetix Multilab II Roorda with DICOM functionality. The objective of this procurement is to provide the surgical service with advanced vascular diagnostic equipment that seamlessly integrated with existing imaging and clinical information systems through DICOM connectivity for their vascular clinic. The Unetix Multiab II Roorda is the only known vascular diagnostic system that is fully compactable with the facility s VascuPro network and reporting platform. Procuring this equipment will ensure continuity of operations, maintain interoperability with current infrastructure, and support efficient delivery of patient care without the need for costly system modification or workflow disruptions at 7400 Merton Minter, San Antonio, Tx 78229. If this is an item your business can provide, please respond to this Sources Sought Notice by 11:00 AM Central Time on Thursday, 19 November 2026. The intent of this notice is to establish sources to define the procurement strategy (e.g. set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon. Interested contractors are requested to respond in accordance with the following: a. where is the item manufactured, the VA is interested in procuring items manufactured in the United States. If you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response. Please note that VA is particularly interested in determining the availability of Service Disable Veteran Owned Small Business/Veteran Owned Small Business or other Small Business manufacturers or authorized distributors that can provide this item. Respond to this notice if you can provide these products listed in the table in the background and requirement section above. In response, please cite your business size status. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept gray market items. Vendors are requested to submit estimated market research pricing with their responses. The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g. if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside). Responses should include: (1) Business Name (2) Business Address (3) Point of Contact - Name - Phone Number - E-mail Address (4) SAM UID Number (5) NAICS code (6) Business Size: SMALL or LARGE (7) Type of Business: SERVICE-DISABLED VETERAN OWNED (SDVOSB), VETERAN OWNED(VOSB), 8A, HUBZone, WOMAN-OWNED (WOSB), etc. (8) Letter stating OEM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment and/or services if applicable (9) GSA/FSS Contract Number if applicable All businesses eligible to provide this item are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement. Send responses to Michelle Cunningham at michelle.cunningham@va.gov. DISCLAIMER: THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition. Due to technical issues, please allow additional time if you re using electronic means. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement based upon responses received to this notice is solely within the discretion of the Government.
-Market Research11/19/2026
Good day, SDVOSB s, VOSB s & SB's Sources Sought INTENT TO SOLE SOURCE Pre-Solicitation. This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs VOSBs , or SBs . This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks. 1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744 is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer. 2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care. 2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays. 3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment. 4.Period of Performance: The product is requested to be delivered no later than December 19th. 5.Type of Contract: Supply: Firm, Fixed Price. 6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below. 6.1 Salient Characteristics NAME BRAND - Equipment Requirement: GE Healthcare QTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer QTY. 6 (P/N: UA2511) Reprocessing Trays for E14C4T Equipment Requirement: Minimum Required Features and Specifications Type / Intended Use: Must be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications. Must provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes. Frequency & Imaging Performance: Must operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate. Must support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system). Biopsy and Procedural Capability: Must include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange. Must accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments. Must permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures. 4. Design & Ergonomics Must be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use. Must include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle. Must be designed for one-handed operation and compatible with sterile probe covers. 5. Compatibility Must be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms. Must connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters. 6. Cleaning & Sterilization Must be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes. Must be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide. 7. Construction & Safety Must be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards). Must comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits. Must be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use. Summary Table Feature Category Requirement Type Triplane transrectal prostate ultrasound transducer Frequency 4 14 MHz Imaging Modes B, M, Color Doppler, Power Doppler (Elastography optional) Biopsy Capability Integrated dual-plane biopsy guide Needle Compatibility 17 18 G Operation One-handed, Smart Button on probe Sterilization Fully immersible, high-level disinfectable Compatibility bk3000, bk5000, bkActiv, bkSpecto Intended Use Prostate imaging and biopsy guidance Condition New OEM product, OEM warranty
-Market Research11/16/2026
This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, “Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-06, effective 8/26/2025. This solicitation is set-aside for 100% total Service-Disabled Veteran-Owned Small Businesses (SDVOSBs). The associated North American Industrial Classification System (NAICS) code for this procurement is 339112, with a small business size standard of 1,000 Employees. The FSC/PSC is W065. The award will be made to the quote most advantageous to the Government and best meets the requirement described in the Statement of Work (SOW). The New Mexico Veterans Affairs Healthcare System (NMVAHCS) is seeking to purchase Laser Equipment Rental Services. ***Please reference the Solicitation and Attachments for additional details***
-Combined Synopsis11/20/2026
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Humidifier Heater base, Humidifier Sensor Cartridge, and Humidifier Expiratory Heater to the , Captain James A. Lovell Federal Health Care Center in North Chicago, IL. General Requirements: Brand Name or Equal The below products are known to meet the governments needs all equal parts will be considered. 950 Humidifier Heater base, 950 Humidifier Sensor Cartridge, and 950 Humidifier Expiratory Heater Wire Adapter or Equal Salient Characteristics: Therapy Profiles: Must support Invasive ventilation Must support Noninvasive ventilation Must support Nasal High Flow therapy. Temperature Probes: Must have no external temperature probes Must incorporate internal temperature probes that do not require special disinfection processing Circuit Compatibility: Must be compatible with single heated circuits for non-invasive ventilation. Must be compatible with double heated circuits for invasive ventilation. User Interface: Must have a simple user interface Must include touch screen monitors to create setting modifications Must allow mode changes Must allow comfort setting adjustments Must display and troubleshoot alarms Must provide access to Information and Service menus Alarms: Must have built-in alarms for various conditions including but not limited to: 1. High Temperature alarms 2. Low Temperature alarms 3. Water Out alarms 4. Circuit Disconnect alarms 5. Reverse Gas Flow alarms 6. System check alarms Compatibility: Must be compatible with all ventilation and gas flow delivery devices that is currently used at FHCC, Specifically, must be compatible with Medtronic 980 ventilators Specifically, must be compatible with Philips V60 BiPAP devices Specifically, must be compatible with Nihon Kohden 330, 440, and 550 ventilator systems All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. SAM Unique ID number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Specialist, Ryan Nugent, at Ryan.Nugent@va.gov no later than 8:00 AM (Central Standard Time), 23 November 2026. 36C25227Q0090 950 Humidifier Heaterbase shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
-Market Research11/23/2026

Additional Details

Solicitation Number

36C24926Q0263

Archive Date

Jul 31, 2026

Office Address

MURFREESBORO, TN, 37129