65--PRE-SOLICITATION NOTICE Medical/Surgical Prime Vendor Program (MSPV)/Emergency Medical Supplies/Tiered Evaluation
Archived on March 2, 2021. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 AM UTC−05:00
- Posted
- September 2, 2020
- Notice type
- Solicitation
- NAICS
- 339113: Surgical Appliance and Supplies Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241)
- PSC
- 65: MEDICAL/DENTAL/VETERINARY EQPT/SUPP
- Last updated
- Apr 29, 2026
Identifiers
- Solicitation number
- 36C24C19Q0033
- Notice ID
- 94cb8518e911487c8ea15b049bbc4882
Description
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
36C24C19Q0033- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- Special NoticeApr 19, 2019
65--Emergency Medical Supplies
- Pre-SolicitationJun 14, 2019
65--PRE-SOLICITATION NOTICE Medical/Surgical Prime Vendor Program (MSPV)/Emergency Medical Supplies/Tiered Evaluation
- SolicitationJun 20, 2019
65--PRE-SOLICITATION NOTICE Medical/Surgical Prime Vendor Program (MSPV)/Emergency Medical Supplies/Tiered Evaluation
- 7×Special NoticeAug 14, 2019
65--Emergency Medical Supplies
- SolicitationCurrentSep 2, 2020
65--PRE-SOLICITATION NOTICE Medical/Surgical Prime Vendor Program (MSPV)/Emergency Medical Supplies/Tiered Evaluation
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
UltraScan Versa Premier Tables | - | Combined Synopsis | 09/27/2026 |
THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. THIS IS STRICTLY MARKET RESEARCH. Patient safety lifts The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide Patient safety lifts. All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum: (1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation. Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via email to kurt.fritz@va.gov RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement. Salient characteristics (QTY 21) Patient Safety Lifts All ceiling mounted hoists, rails, and components must comply with ISO 10535:2021 xy Systems Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. Cover 5m X 10m area with trainer (QTY 1) Cover 4m X 4m area (QTY 9) Cover 4m x 3m area (QTY 2) Cover 3m x 3m area (QTY 1) Linear Tracks Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. 3m Linear Track (QTY 3) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better 4m Linear Track (QTY 4) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up 825 lbs. or better 6m Linear Track (QTY 1) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better Patient Lift Supports minimum 550 lbs. (QTY 17) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: Uses 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 2 hours (for this capacity class). Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information. Patient Lift Supports minimum 825 lbs. (QTY 4) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: dual 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 4 hours or better Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information. Medium Hanger Bar (QTY 21) Lifts up to 825 lbs. Four attachment points for a safe, stable, and comfortable lift. Works with ceiling and mobile lifts and fits standard slings. Strong, rust resistant metal covered with soft, easy to clean foam. Lightweight (4 lbs.) and easy to handle. Medium size (~24 wide) Trainer Module Motor (QTY 1) Reducing bodyweight, relieves up to 100 kg (220 lbs.), Built into the ceiling hoist added to system, controlled via the hand control interface. Safe exercise sessions: positioning lock and fall protection, enabling standing exercises, squats, steps, balance training, and sit-to-stand movements. 30-minute training limit: each session lasts up to 30 minutes per full battery charge, with clear indicators for weight relief and remaining time. After session, will automatically resume normal lift mode. Battery management: 1 hour of charge delivers about 10 minutes of training time. When training ends, it reverts to standard lifting and resumes charging. Installation (QTY 21) Install lift systems in 21 rooms. Labor and the hardware necessary to install the lift systems. Must support up to Level II that is identified in the Infection Control Risk Assessment (ICRA). Perform weight testing and certification of the installed lift systems. Removal of 18 existing lift systems. Design / Drafting (QTY 1) Stamped Engineering Calculations Slings (QTY 84) Support 450 lbs. or better Made from polypropylene material Disposable Limb Sling (QTY 1 per system) Disposable Basic High sling (QTY 1 per system) Disposable Twin Turner (QTY 1 per system) Disposable Repositioning Sling (QTY 1 per system) User Training (QTY 1) | - | Market Research | 09/10/2026 |
See document 36C24126Q0535_1. | - | Market Research | 09/07/2026 |
36C24125R0116 Anesthesia procurement | - | Pre-Solicitation | 11/02/2026 |
The Department of Veterans Affairs (VA) intends to solicit for anesthesia units (to include warranty, maintenance and training) for inclusion into the National Equipment Catalog (NEC). This is a Request for Proposals (RFP) for anesthesia units at the national level. The Department of Veterans Affairs intends to establish Indefinite Delivery/Indefinite Quantity (ID/IQ) contracts. This solicitation will result in multiple awards. The ID/IQs will cover the entire nation. The contract s performance period is for ten years, inclusive of a five-year base period and one, five-year option period. Telephone requests for information or questions will NOT be accepted. PLEASE SUBMIT QUESTIONS REGARDING THIS RFP NO LATER THAN 4PM EST ON FRIDAY, AUGUST 21, 2026. QUESTIONS OR COMMENTS SHOULD BE SUBMITTED TO THE CONTRACT SPECIALIST, MELANIE STOCKMAN AT melanie.stockman@va.gov . | - | Combined Synopsis | 10/05/2026 |
Additional Details
Solicitation Number
36C24C19Q0033
Archive Date
Mar 2, 2021
Office Address
TOGUS, ME, 04330