Notice ID: af7b317838924a03a55d10b56444f56cSpecial Notice
J045--San-I-Pak Preventive Maintenance Service
Archived on September 4, 2022. Full description on SAM.gov.
Overview
- Posted
- August 5, 2022
- Notice type
- Special Notice
- NAICS
- 811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 250-NETWORK CONTRACT OFFICE 10 (36C250)
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C25022Q0482
- Notice ID
- af7b317838924a03a55d10b56444f56c
Description
The Department of Veterans Affairs, Network Contracting 10 (NCO10), in accordance with FAR 13.106-1(b)(2) intends to negotiate on a sole source basis with San-I-Pak Pacific Inc, NAICS 811310 applies. The Contractor shall furnish all labor, materials, parts/supplies, equipment, tools, supervision, San-I-Pak factory trained technicians, and transportation required to perform required maintenance and repairs in accordance with Original Equipment Manufacturer (OEM) specifications for the government owned San-I-Pak Compactor Sterilizer located at the Richard L. Roudebush Veterans Affairs Medical Center (VAMC) 1481 W 10th Street, Indianapolis IN 46202, for a base period of one (1) year with four (4) one (1) year options, exercisable at the Government s discretion. This notice of intent is not a request for competitive proposals. It is not a solicitation or request for offers. No solicitation package is available. A determination not to compete is solely within the discretion of the Government. Any response to this notice must show and convincing evidence that competition would be advantageous to the Government. Responses must be received than 3:00 pm on August 9, 2022. No telephone or email inquiries will be accepted. All responses must be mailed to Olalekan Ismail by email olalekan.ismail@va.gov or at Network Contract Office 10 (NCO10), 8888 Keystone Crossing Suite 1100 Indianapolis, IN 46240.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C25022Q0482- Special NoticeCurrentAug 5, 2022
J045--San-I-Pak Preventive Maintenance Service
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
This is a Sources Sought Notice (a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited. (b) Although "proposal," "offeror," contractor, and "offeror" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. (c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as "proprietary" or "confidential," intended to restrict distribution will not be distributed outside of the Government, except as required by law. (d) This Sources Sought is issued by VISN 2 Contracting Office in Bronx, NY for the purpose of collecting information on Petroleum Bulk Storage Tank Maintenance Services at New Jersey Health Care System VA Medical Center, Lyons Campus at 151 Knollcroft Road, Lyons, NJ 07939 and East Orange Campus at 385 Tremont Avenue, East Orange, NJ 07018. The VA is seeking to provide for this requirement as of 09/10/2026 to establish a new service. NAICS Code: 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. PSC Code: J045 Maintenance, Repair, and Rebuilding of Equipment: Plumbing, Heating, and Waste Disposal Equipment. (e) Cursory market research has identified several small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment are encouraged to email a capability statement and full information to Natalie Acevedo at Natalie.Acevedo@va.gov by 8/27/2026 at 12:00 PM ET. (f) Requested Information Interested parties are invited to submit a capability statement including the following: Company name, address, UEI number, and point of contact information Business size and socio-economic status (SDVOSB/VOSB/8(a)/HUBZone/other) NAICS and PSC Codes under which your company typically performs these services Corporate experience and past performance relevant to petroleum bulk storage tank maintenance (last 3 years) List of certifications (OSHA 40 hour, HAZWOPER certificate, NJDEP approved Class A/B operator training certificate) Approximate number of trained personnel available Ability to meet response/turnaround times Any GSA/FSS, VA contract schedules, or other vehicles available (g) Scope of Work: The Contractor shall be responsible for the specified maintenance of the petroleum bulk storage tank systems listed in the tables incorporated in sections (2) and (3) of this scope of work. Maintenance items shall include tank monitoring panels, probes, sensors, thermal printers, alarms, batteries, and all associated components of the tank gauging and leak detection systems. The Contractor shall provide properly trained technicians to service, repair, and/or calibrate tank monitoring systems, probes, and all other accessories in accordance with the manufacturer s instructions and this scope of work. Annual Maintenance Fuel Polishing Fuel Cleaning Monthly Maintenance Triennial Maintenance Triennial Maintenance VA NJ Healthcare System Above, Underground Storage, Day, and Belly Tank Inventory East Orange VA Medical Center Tank No. Location Size (Gallons) A-Tank Underground/Diesel 4,000 B-Tank Underground/Diesel 4,000 C-Tank Underground/Diesel 1,000 CN-Tank Underground/Diesel 15,000 DN-Tank Underground/Diesel 15,000 Building 8 Generator Tank Underground/Diesel 3,000 Building 8 Boiler fuel tank #1 Underground/Diesel 20,000 Building 8 Boiler fuel tank #2 Underground/Diesel 20,000 Building 8 Boiler fuel tank #3 Underground/Diesel 20,000 Building 8 Boiler fuel tank #4 Underground/Diesel 20,000 Building 15 tank Underground/Diesel 3,000 Building 7 Generator Aboveground/Diesel 2,000 A-1 DT Day Tank 275 B-1 DT Day Tank 275 C-Tank Day Tank 250 CN-Tank Belly Tank 1520 DN-Tank Belly Tank 2500 Building 15 tank Belly Tank 531 Building 7 Generator Day Tank 75 Lyons VA Medical Center Tank No. Tank Type/Fuel Type Size (Gallons) 1 Underground/Diesel 1,500 2&9 Underground/Diesel 1,500 3&4 Underground/Diesel 1,500 7&8 Underground/Diesel 1,500 10 Underground/Diesel 2,500 13&14 Aboveground/Diesel 1,500 14-T1 Underground/Diesel 40,000 14-T2 Underground/Diesel 40,000 14-T3 Underground/Diesel 40,000 14-T4 Underground/Diesel 40,000 14-T5 Underground/Diesel 10,000 49-T1 Aboveground/Gasoline 900 49-T2 Aboveground/Diesel 900 49-T3 Aboveground/Diesel 400 49-T4 Aboveground/Diesel 400 53 Underground/Diesel 1,500 54 Underground/Diesel 1,500 57 Underground/Diesel 1,500 135 Underground/Diesel 6,000 136 Underground/Diesel 15,000 141 Aboveground/Diesel 1,500 143 Underground/Diesel 2,500 1 Day Tank 155 2&9 Day Tank 100 3&4 Day Tank 75 7&8 Day Tank 275 10 Day Tank 75 13&14 Day Tank 75 54 Day Tank 75 57 Day Tank 75 135 Belly Tank 1500 136-1 Belly Tank 800 136-2 Belly Tank 800 141 Belly Tank 400 143 Day Tank 100 Storage Tank Monitoring System Inventory East Orange Medical Center Location Device Model Tanks Monitored Vault Omntec Proteus B/K/X TA, TB, TC CN and DN Omntec Proteus B/K/X T1,T2 Building 7 Omntec Proteus B/K/X T1 Building 8 boilers tanks Omntec Proteus B/K/X T1,T2,T3,T4 Building 8 generator Omntec Proteus B/K/X T1 Building 15 Omntec Proteus B/K/X T1 Lyons Va Medical Center Location Device Model Tanks Monitored 1 Generator Veeder-Root TLS-350 Plus T1 2&9 Generator Veeder-Root TLS-350 Plus T1 3&4 Generator Veeder-Root TLS-350 Plus T1 7&8 Generator Veeder-Root TLS-350 Plus T1 10 Generator Veeder-Root TLS-350 Plus T1 13&14 Generator Veeder-Root TLS-350 Plus T1 14 Building Veeder-Root TLS-350 Plus T1, T2, T3, T4, T5 49 Building Veeder-Root TLS-350 Plus T1, T2, T3, T4 53 Generator Veeder-Root TLS-350 Plus T1 54 Generator Veeder-Root TLS-350 Plus T1 57 Generator Veeder-Root TLS-350 Plus T1 135 Generator Veeder-Root TLS-350 Plus T1 136 Generator Veeder-Root TLS-350 Plus T1 141 Generator Veeder-Root TLS-350 Plus T1 143 Generator Veeder-Root TLS-350 Plus T1 | 85% | Market Research | 08/27/2026 |
AMENDMENT TO CORRECT PRICE/COST SCHEDULE. PLEASE SUBMIT OFFERS WITH THIS CORRECT VERSION. RESPONSE TO QUESTIONS. | 81% | Combined Synopsis | 11/09/2026 |
Amendment 1 - The set-aside has been removed; this requirement is now Full and Open Competition. Response date has been updated to 30 June 2026 at 1000 am EST. Questions regarding this requirement must be submitted to the Contracting Officer or Specialist by 18 June 2026 at 1000am EST. This is a Request for Quotation (RFQ) for commercial items issued in accordance with the procedures in Revolutionary Federal Acquisition Overhaul (RFO) Subpart 12.2, supplemented with additional information included in this notice for Preventive Maintenance Services for Ingersoll Rand Compressors and associated Air Systems and Dryers. | 78% | Combined Synopsis | 06/30/2026 |
76% | Combined Synopsis | 11/10/2026 | |
NOTICE OF INTENT TO SOLE SOURCE / COMBINED SYNOPSIS-SOLICITATION. Date: 10/1/2026 Requirement Title: HPAC Maintenance Renewal at Portsmouth Naval Shipyard Detachment San Diego (PNSDETSD) Solicitation Number: N3904026Q4993 Response Deadline: 10/6/2026 at 5:00 PM EST Contracts POC: Lisa Fielding, lisa.a.fielding.civ@us.navy.mil GENERAL INFORMATION: 1. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. This combined synopsis/solicitation SHALL be posted on SAM.gov. 2. This solicitation documents and incorporates provisions and clauses of the Federal Acquisition Regulation (FAR) and the Defense Federal Acquisition Regulation Supplement (DFARS) that are in effect on the date of this solicitation's issuance. It is the contractor's responsibility to be familiar with the applicable provisions and clauses. The authoritative sources for the most current regulations are: • FAR: The official FAR website, which reflects the ongoing "Revolutionary FAR Overhaul" (RFO): https://www.acquisition.gov/far-overhaul • DFARS: The official DoD Class Deviations website, which contains the most recent updates to the DFARS: https://www.acq.osd.mil/dpap/dars/dfars_far_overhaul_class_deviations.html 3. This solicitation is being issued as a: Request for Quotation (RFQ) 4. This acquisition is: Sole Source to American Compressor Company (ACC) 5. North American Industry Classification System Code (NAICS): NAICS 811310 6. The size standard is: $12.5 in Millions of Dollars. REQUIREMENT INFORMATION: Portsmouth Naval Shipyard requests a quote to provide the following: Renewal of HPAC maintenance services on three (3), Universal HIGHPACK Model 55H75 five stage air cooled, oil lubricated, reciprocating compressors at Portsmouth Naval Shipyard Detachment San Diego (PNSDETSD. The HPAC maintenance will require four separate intervals for service. These intervals are every 500 hours (or, semi-annual), every 1200 hours (or, annual), and every 3000 hours (or every two years) and every 6000 hours (or every 4 years). In addition to the scheduled preventative and corrective maintenance, the Contractor shall provide over and above repair services if it is identified that current issues with equipment exist that impact the equipment receiving maintenance. See Attachment 4 HPAC Maintenance Schedule for the maintenance intervals by year and by the equipment listed in accordance with the Statement of Work. Period of Performance: Date of award – 1 year with four (4) 1 year Option periods Attachment 1: Statement of Work Attachment 2: Sole Source Justification Attachment 3: Wage Determination San Diego Attachment 4: HPAC maintenance Schedule Attachment 5: HEC CCCD Attachment 6: OPSEC redacted Exhibits: Exhibit A CDRLs 001-002 Exhibit B CDRLs 001-002 Exhibit C CDRLs 001-002 Exhibit D CDRLs 001-002 Exhibit E CDRLs 001-002 METHOD OF QUOTE SUBMISSION: Offer shall be emailed to the Contracts POC Lisa Fielding, lisa.a.fielding.civ@us.navy.mil System for Award Management (SAM): Vendor must be registered in the SAM database to be considered for award. Registration is free and can be completed on-line at http://www.sam.gov/. Validity: The quote must remain valid for a minimum of 30 calendar days. Technical Requirements: Since this is a sole-source procurement to the OEM, the technical quote is simplified. The Offeror shall provide a brief capability confirmation stating that factory-certified technicians will perform the services and that OEM proprietary replacement parts will be used Price Reasonableness: The proposed price will be evaluated for reasonableness by comparing the contractor's total quote against the Independent Government Cost Estimate (IGCE) and historical prices paid by both government and commercial entities for the same or similar services, ensuring the best value to the Navy. Contractor Responsibility: The contractor must be determined responsible in accordance with FAR Part 9 (active SAM.gov registration, no active debarments, and satisfactory past performance). Over and Above Work CLINs have a "Not to Exceed" (NTE) funding limit of $10,000.00. All quotes shall include the Request For Quote (RFQ) completed in its entirety. Please fill in all yellow highlighted blocks in form and provide signature | 73% | Combined Synopsis | 10/06/2026 |
Additional Details
Solicitation Number
36C25022Q0482
Archive Date
Sep 4, 2022
Office Address
DAYTON, OH, 45428