GovChime
Notice ID: b4444a450d8c470e90c5873848ea4debAward NoticeAwarded

Z1DA--Upgrade Mental Health Restrooms - 610-24-511

Awarded on May 30, 2024. Full description on SAM.gov.

Awarded tounder 36C25024C0115 (source: SAM.gov award notice)• $1.4M

Overview

Posted
May 31, 2024
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)

Notice details

Place of performance
Northern Indiana Health Care System V.A. 1700 E. 38th. Street, Marion, 46953
Last updated
Sep 9, 2025
Award date
May 30, 2024
Award amount (SAM.gov award notice)
$1.4M

Identifiers

Solicitation number
36C25024B0046
Notice ID
b4444a450d8c470e90c5873848ea4deb
Award number (PIID)
36C25024C0115

Description

Questions and Answers: Are ICRA Barriers required to go up to deck or can we run them up to the ceiling? The ICRA can go to the ceiling as long as negative pressure is maintained at all times. Are ICRA barriers required to be 1-hour fire barrier type ? Yes GI10, Special Note A "Contractor to remove window(s) for negative air with hepa air filter and waste removal, upon completion and prior to cleanup of the current restroom reinstall window(s) to match existing; repair any damages to adjacent areas". Are we required to remove a window and reinstall for each phase to achieve negative air? Please designate on drawing which windows can be removed for each phase and provide details of window type/wall construction so that we may provide accurate pricing on window removal/replacement & wall repair. The glass will be removed by removing the interior and exterior seal the frame and glass will be protected and glass re-installed upon completion of the current room being worked on. At the site visit it was stated that there IS NO med gas work. Please confirm that there is no med-gas work on this project. Drawing PL100 shows a zone valve schedule for med gas and a medical gas alarm panel schedule. Clarify work involving these details. The schedules were added to make the contractor aware that there is med gas near the scope of work. There is no med gas work. Drawing AS102 , detail E7 "TYPICAL WALL SECTION" calls out to "provide continuous blocking behind wall mounted standards". Please clarify. Wall mounted standards are all standard items that will be mounted to the wall for example: grab bars, fixtures, and accessories. Are the following legends for reference only since there are no plans associated with the described areas? Zone Valve Schedule (ZV-1)/Observation Room 123 No other reference on plans shown for replacement. Medical Gas Alarm Panel Schedule/Nurse Station Room 122 No other reference on plans shown for replacement. Yes, they are only for reference showing that there is med gas near the scope of work. Is there any work needed that is associated with these areas? No work associated with these areas.

Full description on SAM.gov

Award Overview

Award Number

36C25024C0115

Award Amount (SAM.gov award notice)

$1.4M

Award Date

May 30, 2024

Awardee

Awardee UEI

Q1QHLZGHL278

Original Solicitation

Notice ID: b4444a450d8c470e90c5873848ea4deb

Posted Date: May 31, 2024

Original Response Deadline: Not specified

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C25024B0046
  1. Pre-Solicitation
  2. Solicitation
  3. Awarded

This opportunity has been awarded.

  1. Pre-SolicitationFeb 16, 2024

    Z1DA--Upgrade Mental Health Restrooms 610-24-511

    Notice 73f916ec975747878920b46c1948418e on SAM.gov

  2. 4×
    SolicitationMar 5, 2024

    Z1DA--Upgrade Mental Health Restrooms 610-24-511

    Notice 5170e38b57a54984958f8e47165cf39f on SAM.gov

  3. AwardedCurrentMay 31, 2024

    Z1DA--Upgrade Mental Health Restrooms - 610-24-511

    Notice b4444a450d8c470e90c5873848ea4deb on SAM.gov