Notice ID: fd6e148a5c254cf280bd2df6da354739Award NoticeAwarded
4120--Equipment - Mobile Chiller - Battle Creek
Awarded on February 12, 2024. Full description on SAM.gov.
Awarded tounder 36C25024P0678 (source: SAM.gov award notice)• $220.9K
Overview
- Posted
- February 12, 2024
- Notice type
- Award Notice
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
Notice details
- Place of performance
- Department of Veterans Affairs Battle Creek Medical Center 5600 W Dickman Rd., Battle Creek, 49037
- Last updated
- Dec 4, 2025
- Award date
- Feb 12, 2024
- Award amount (SAM.gov award notice)
- $220.9K
Identifiers
- Solicitation number
- 36C25024Q0195
- Notice ID
- fd6e148a5c254cf280bd2df6da354739
- Award number (PIID)
- 36C25024P0678
Description
1. Description. Purchase 80 Ton Chiller and trailer. 2. Background. Battle Creek VAMC requires the purchase of Purchase of a new 80 Ton CGAM air cooled chiller with pumping package that will be mounted on a new furnished trailer. The Chiller will be used as a backup chiller source for HVAC systems for various buildings as needed during service issues. 3. Scope. Purchase new Trane 80 Ton CGAM air cooled chiller with pumping package (Brand Name or Equal) mounted on a mobile trailer. Vendor will mount the chiller on the new tailer. 4. Specific Tasks. Purchase new Trane 80 Ton CGAM air cooled chiller with pumping package mounted on a trailer. Offers shall supply authorized distributor letters from the manufacturer along with their submission to be considered for award. The following minimum requirements must be met: (1) 80-ton CGAM air cooled chiller, including: Air-Cooled Scroll Packaged Chiller 80 nominal tons 60 hertz 460 volt 3 phases High efficiency/performance Full factory refrigerant charge (R-454B) With factory installed freeze protection Refrigerant isolation valves (discharge valve) UL listed to US and Canadian safety standard ASHRAE 90.1 all versions up to 2016 AHRI certified Factory installed flow switch - set point 60 cm/sec Std cooling (40 to 65F/4.44 to 18C) Grooved pipe connection Factory insulation 0.75" Wide ambient (0 to 125F/-18 to 52C) Lanced aluminum fins Across the line starter/direct on line Single point connection main line unit power-ancillary items require other power Circuit breaker Enclosure type UL 1995 rated for outdoor applications BACnet interface External chilled/hot water and demand limit setpoint - 4-20mA Default A short circuit rating Elastomeric isolators With water strainer factory installed Comprehensive acoustic package Architectural louvered panels (2) Integral pumping and piping package including: Integral Piping Package with: -Pump: Taco 275 GPM at 150 ft H2O, 20 HP, Water, TEFC, Shaft Grounding Ring, Drip Cap -Suction Diffuser -¾ Thread-O-Let on Pump Suction Line with Cap -1 TR200 VFD 20 HP with 3-Contactor Bypass in NEMA 3R Enclosure --Non-Fused Disconnect Switch --Pump Line-Off-Auto Switch --Hand-Off-Auto Switch with Status Indicator Light --Door mount VFD Display with Weather Cover -Lever Operated Grooved Isolation and pump bypass Butterfly Valves -4 Schedule 40 Grooved/Welded Steel Pipe, Valves, and Fittings -Connection Pressure and Temperature Gauges -150 PSI Pressure Relief Valve with Manual Test -Differential Pressure Gauge Manifolds with 0-160psi Gauge: --Suction Guide Inlet, Pump Suction, Pump Discharge --Evaporator Strainer Inlet, Evaporator Inlet/Strainer Outlet, Evaporator Outlet -Supply and Return Connections: -4 Victaulic -Gear Operated Butterfly Valves -Temperature and Pressure Gauges -Insulation on hydronic piping Cam Lock Main Power Connections with Covers 120/60/1 20A Shore Power Connection (controls, & compressor heaters) -Electrical interlock on HV control panel door -Back-feed Prevention -RC Snubber 460x120V 3kVA Transformer to Power Convenience outlet and Evaporator heaters -Evaporator Heaters Off-Auto Switch with Indicator Light Extended Vent and Drain Lines to side of unit Miscellaneous Components -200 Flex Hose -2 50 ft & 4 25 ft Sections with grooved ends -6 4 grooved couplings -Qty 16 (4 per phase plus ground) - 50 M->F Cam lock 2/0 AWG Power Cables -2 Storage Boxes for Power Cables and Hoses -Chiller mounted (bolted) to owner furnished trailer (delivered to Vendor to have chiller installed) 1-year parts warranty (1-year parts warranty is not covered by 12/36 delayed startup protection) Freight to customer site Unit tested prior to shipment. Provide new mobile trailer at correct size and weight to support the chiller. Chiller to be mounted on the trailer for delivery to the VA. 5. Delivery Schedule. Offerors shall provide estimated delivery lead times upon submission.
Award Overview
Award Number
36C25024P0678
Award Amount (SAM.gov award notice)
$220.9K
Award Date
Feb 12, 2024
Awardee
Awardee UEI
XZ2XCSGEQME5
Awardee CAGE Code
7BCA8
Original Solicitation
Notice ID: fd6e148a5c254cf280bd2df6da354739
Posted Date: Feb 12, 2024
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $168.5KSigned Aug 7, 2026
- $17.8KSigned Jul 22, 2026
- $19.2KSigned Apr 24, 2026
- $15.4KSigned Mar 19, 2026
- $28.2KSigned Mar 17, 2026
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C25024Q0195- Pre-Solicitation
- Solicitation
- Awarded
This opportunity has been awarded.
- Pre-SolicitationDec 27, 2023
4120--Equipment, Mobile Chiller, Battle Creek
- 3×SolicitationDec 27, 2023
4120--Equipment, Mobile Chiller, Battle Creek
- AwardedCurrentFeb 12, 2024
4120--Equipment - Mobile Chiller - Battle Creek
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
36C25024Q0195
Archive Date
Apr 12, 2024
Office Address