GovChime
Notice ID: 7aef7e1f9e2d4d34a78d7337c6d00361Award NoticeAwardedArchived

Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

Awarded on June 9, 2026. Full description on SAM.gov.

Awarded tounder 36C25026C0120 (source: SAM.gov award notice)• $543.6K

Overview

Posted
June 10, 2026
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
236220: Commercial and Institutional Building Construction
Agency
Department of Veterans Affairs

Notice details

Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Place of performance
Richard L. Roudebush VAMC 1481 West 10th Street, Indianapolis, Indiana, 46202
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov
Award date
Jun 9, 2026
Award amount (SAM.gov award notice)
$543.6K

Identifiers

Solicitation number
36C25026B0025
Notice ID
7aef7e1f9e2d4d34a78d7337c6d00361
Award number (PIID)
36C25026C0120

Description

The intent of this project is to provide a code-compliant, secure, negative-pressure Hazardous Drug Storage Room that meets VA pharmacy safety, infection control, ventilation, and security requirements. The Contractor shall deliver a complete, fully operational, tested, and accepted system. Work that is reasonably inferable from the Contract Documents shall be included, whether every individual component is explicitly shown. By submission of a bid, the Contractor acknowledges that it has reviewed, coordinated, and understood all Contract Documents, including drawings, specifications, design narrative, phasing requirements, and VA operational constraints. The Contractor is fully responsible for delivering a complete, operational, and code-compliant project, including Site verification and coordination, Demolition and construction, Mechanical, electrical, fire protection, and security systems, Controls and BMS coordination, Testing, TAB, and commissioning support, ICRA, PCRA, and ILSM implementation, Temporary facilities, barriers, and protections, Final cleaning, as-builts, O&M manuals, and warranties.

Full description on SAM.gov

Award Overview

Award Number

36C25026C0120

Award Amount (SAM.gov award notice)

$543.6K

Award Date

Jun 9, 2026

Awardee

Awardee UEI

SW9UWJPMGKA7

Awardee CAGE Code

5KE56

Awardee Address

CELINA, OH 45822, OH

Original Solicitation

Notice ID: 7aef7e1f9e2d4d34a78d7337c6d00361

Posted Date: Jun 10, 2026

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C25027C0016
    ARMCORP CONSTRUCTION INC
    Department of Veterans AffairsNAICS 236220
    $8.8MSigned Nov 6, 2026
  • 36C77624N0084
    ARMCORP CONSTRUCTION, INC.
    Department of Veterans AffairsNAICS 236220
    $828.1KSigned Nov 4, 2026
  • 36C25026D0072
    ARMCORP CONSTRUCTION INC
    Department of Veterans AffairsNAICS 236220
    —Signed Sep 15, 2026
  • 36C25025C0132
    ARMCORP CONSTRUCTION INC
    Department of Veterans AffairsNAICS 236220
    $10.8MSigned Aug 28, 2026
  • 36C25025C0132
    ARMCORP CONSTRUCTION INC
    Department of Veterans AffairsNAICS 236220
    $10.4MSigned Jul 30, 2026

Contacts

Contracting Officer

Primary Contact

Stacie Hill
Contract Specialist

Documents

Files (1)

  • 36C25026C0120_1.docx

    21 KBAdded in Award Notice version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Award NoticeArchivedCurrent

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice 7aef7e1f9e2d4d34a78d7337c6d00361 on SAM.gov

Other notices for this solicitation

  1. Pre-SolicitationRelated noticeJan 29, 2026

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice c01d585735fe4a72af34e608f2fe6870 on SAM.gov

  2. SolicitationRelated noticeFeb 19, 2026

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice c3b0c0f923e3495a8194f672c18fa0c5 on SAM.gov

  3. SolicitationRelated noticeFeb 19, 2026

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice c15e87d350244e9ca1873fd8498524ea on SAM.gov

  4. SolicitationRelated noticeMar 27, 2026

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice 64614d74480945588e832fcf0ccc346e on SAM.gov

  5. SolicitationRelated noticeApr 8, 2026

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice b550f521564942b49bed6575bcc9958f on SAM.gov

  6. SolicitationRelated noticeApr 15, 2026

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice b5fcd0ca9fb34345bbbc5fd410122fdf on SAM.gov

  7. SolicitationRelated noticeApr 23, 2026

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice 506e8d2531c84e3592058fc9748afb2a on SAM.gov

  8. SolicitationRelated noticeApr 29, 2026

    Z1DA--Renovate Space to Meet Hazardous Storage Room Requirements - 583-24-527

    Notice e8525e3a9e8546ad83415eeec53f56ae on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
539-23-101 Modernize Nurse Call Statement of Work The Contractor shall provide all tools, equipment, material, permits, labor, and supervision required to completely perform the required construction work for the Modernize Nurse Call Project (539-23-101) All work shall be completed in accordance with the project drawings and specifications. The scope of work involves renovation for nurse call system in the main hospital and CLC at the VA Cincinnati Site. Work includes, but is not limited to, general construction, alterations, electrical, and telecommunications necessary for demolition and removal of existing nurse call completion and installation of new work. A full list of requirements and further details are provided in the project drawings and specifications. The above construction Statement of Work (SOW) constitutes a basic outline of work and in no way outlines all details for the construction of this project. It is recommended that a detailed inspection of the premises, drawings and specifications be initiated to determine the needs and conditions for the construction of this project.
-Pre-Solicitation11/30/2026
CONSTRUCTION STATEMENT OF WORK Install Roof Equipment Railings Project No. 539-22-206 The Contractor shall provide all tools, equipment, material, permits, labor, and supervision required to completely perform the required construction work for the Install Roof Equipment Railings project, including prepare site for building operations, demolition and removal of existing structures, furnish labor and materials and perform work as required by drawings and specifications. Work includes carpentry and roofing work, and certain other items shown and specified in project drawings and specifications. This construction project will install various rooftop safety railings and work platforms at the Cincinnati VA. This work includes general construction, roofing, abatement, etc. The above construction Statement Of Work (SOW) constitutes a basic outline of work and in no way outlines all of the details for the construction of this project. It is recommended that a detailed inspection of the premises, drawings and specifiction be initiated to determine the needs and conditions for the construction of this project. Period of Performance: All phases of work completed within 240 calendar days after issuance of the Notice to Proceed.
-Pre-Solicitation11/30/2026
This project is for the construction of EHRM Infrastructure Upgrades at the Louis A Johnson VA Medical Center in Clarksburg, WV.
-Market Research11/13/2026
The project’s general scope of work is to furnish all tools, equipment, material, permits, labor, supervision, and all other necessary resources to accomplish the following work: This project replaces a portion of the existing campus water loop piping and existing campus water loop isolation valves. The project also includes installing a water booster pump that will be powered by a new equipment branch of emergency power in Building 22. For the new equipment branch of emergency power to be added, new wiring will feed from Building 19 (generator building) utilizing an existing underground conduit to Building 22 to feed a new emergency power distribution panel which will replace the existing emergency power distribution panel that does not meet code requirements. Installation of a new automatic transfer switch and panelboard along with wiring and conduits will be required to create the new equipment branch of emergency power. The project will also disturb many portions of the existing asphalt roadways and parking lots as well as concrete sidewalks and curbing due to excavation work. The contractor shall patch or replace asphalt and concrete as shown on the drawings and repair any areas of the landscaping and lawn that get disturbed during the project. The existing campus water loop piping is located below many of the existing campus roadways and sidewalks, and it is anticipated that most of the new piping will be as well. Therefore, this project shall be completed in phases to allow campus access for employees and Veterans and maintain water service until a tie-in to an existing building service pipe is to take place. If a shutdown of water service for any building is required during the duration of the project, it must be coordinated with the COR. Period of performance is 300 calendar days from receipt of the Notice to Proceed.
-Pre-SolicitationOpen
-Special NoticeOpen

Additional Details

Solicitation Number

36C25026B0025

Archive Date

Jul 10, 2026

Office Address