Notice ID: 94ec79924d204d9681e84a9e3779e155Award NoticeAwarded
J061--Electrical Inspection, Testing & Maintenance Services
Awarded on December 11, 2025. Full description on SAM.gov.
Awarded tounder 36C25026P0198 (source: SAM.gov award notice)• $250.0K
Overview
- Posted
- December 11, 2025
- Notice type
- Award Notice
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 561210: Facilities Support Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 250-NETWORK CONTRACT OFFICE 10 (36C250)
- Place of performance
- Department of Veterans Affairs Aleda E. Lutz Department of VA Medical Center, Saginaw, MI, 48602-5251
- PSC
- J061: MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
- Last updated
- Aug 21, 2026
- Award date
- Dec 11, 2025
- Award amount (SAM.gov award notice)
- $250.0K
Identifiers
- Solicitation number
- 36C25026Q0069
- Notice ID
- 94ec79924d204d9681e84a9e3779e155
- Award number (PIID)
- 36C25026P0198
Description
Questions and Answers from RFQ 36C25026Q0069 The Item 0001 apparently refers to the set of all other items listed below it. Should the price fields for Item 0001 be left blank, or should they show the total sum of the other items? It can show the total amount of the job No test specifications were provided. Can you provide test specifications or the latest test report as an example? Test specifications will be submitted with the revision. See 3.C. Work items, definitions, and references shall comply with the latest edition of the NETA Maintenance Testing Specifications (MTS) and with the VHA Directive, Electrical Power Distribution System. Below is a list of electrical equipment that shall be maintained and tested: Regarding Item 0003: Can MV Liquid Filled Transformers testing be limited to oil sampling, and inspection? NO Per 3.C. If the answer to the previous question is no, should we perform tests for Polarization Index, Excitation Current, Turns Ratio, Insulation and Winding Resistance on the MV Transformers? Regarding Item 0004: Are the (24) dry-type transformers listed low-voltage transformers? Information provided in Section C of the Statement of Work Is it really necessary to test all (550) circuit breakers by primary injection, or can they be tested by secondary injection? Primary Injection is required for all Frame 250Amp and higher Regarding Item 0009: Should the cables be tested using the VLF method? Megger Testing Regarding Item 0010: Is it necessary to perform insulation tests on the panels, or can they simply be visually inspected? See 3.C. Regarding Item 0011: Please explain in more detail what these (300) Phenolic Labels would be. Are they name tags or another type? Will the VA provide the files for printing? Please provide details and dimensions of the labels. Electrical catalog contains Phenolic Labels Does Item 0013 require scanning only the equipment listed in the other items, or is there a separate inventory/list of equipment that needs to be scanned? See Appendix B (IR Scan Column) Please explain what should be priced in the Item: Documentation (0014). See 3.H., 3.I., 3.F., 3.M., 3.N. Could you please provide the previous Arc Flash analysis report? Â Information included in the Electrical Equipment Catalog Appendix B 2025. We understand that a new and revised scope of work statement is to be issued through an amendment. Please provide a bid due date extension of at least 5 working days after this amendment is issued to allow time for critical document distribution and responsible bid preparation. An extension of 5 calendar days will be added to the current response due date.
Award Overview
Award Number
36C25026P0198
Award Amount (SAM.gov award notice)
$250.0K
Award Date
Dec 11, 2025
Awardee
Awardee UEI
ZPJCWBNXLGT3
Awardee CAGE Code
8ZUG3
Awardee Address
SAN DIEGO, CA 92130, CA
Original Solicitation
Notice ID: 94ec79924d204d9681e84a9e3779e155
Posted Date: Dec 11, 2025
Original Response Deadline: Not specified
Contacts
Contracting Officer
Primary Contact
Documents
Select documents to download
Showing 10 of 14 items
Document | Source | Agency | Posted Date | File Size | Actions | |
|---|---|---|---|---|---|---|
| Presolicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 14.55 KB | |||
| Presolicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 24.18 KB | |||
| Presolicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 15.3 KB | |||
| Solicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 2.44 MB | |||
| Solicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 198.88 KB | |||
| Solicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 833.56 KB | |||
| Solicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 4.67 MB | |||
| Solicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 99.17 KB | |||
| Solicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 307.51 KB | |||
| Solicitation | VETERANS AFFAIRS, DEPARTMENT OF | Dec 11, 2025 | 4.8 MB |
Showing 1 to 10 of 14 results
Lifecycle
Solicitation:
36C25026Q0069- Awarded
This opportunity has been awarded.
- AwardedCurrentDec 11, 2025
J061--Electrical Inspection, Testing & Maintenance Services
Similar Opportunities
- H942--Annual Inspection of Energy Control Procedures: Lockout Tagout
Department of Veterans Affairs · Posted 08/24/2026
- S215--Spacesaver and VIDIR Bed Lift Preventative Maintenance Services - SAVAHCS
Department of Veterans Affairs · Posted 10/26/2026
- S215--Spacesaver and VIDIR Bed Lift Preventative Maintenance Services - SAVAHCS
Department of Veterans Affairs · Posted 10/05/2026
- R499--FY26 Lifeguard and Pool Maintenance Services (B+ OPT)
Department of Veterans Affairs · Posted 09/16/2026
- J045--Sources Sought/RFI, Including Industry Days WV VA Medical Centers Facility Maintenance & Repairs BPA RFI Clarksburg, Beckley, and Huntington WV VAMC Mechanical, Plumbing, and Electrical Systems
Department of Veterans Affairs · Posted 07/29/2026
Additional Details
Solicitation Number
36C25026Q0069
Archive Date
Mar 20, 2026
Place of Performance Country
United States
Office Address
DAYTON, OH, 45428