GovChime
Notice ID: 79b052a383134b7c8e3dc9c418e3bd13Combined Synopsis/Solicitation

4420--SPS Steam Water Heater (Equipment) - VAMC Chillicothe

Archived on October 23, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM EDT
Posted
September 21, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Place of performance
Department of Veterans Affairs Chillicothe VAMC, Chillicothe, Ohio, 45601
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25026Q1040
Notice ID
79b052a383134b7c8e3dc9c418e3bd13

Description

The purpose of this amendment is to post questions received and provide the facilities responses. The response date and time remain unchanged. 1. DELIVERY / LEAD TIME SOW paragraph 4 requires all wetted parts to be 316 or 316L stainless steel on an ASME-stamped packaged unit. Manufacturers we have approached indicate this is a made-to-order build rather than a catalog item, with fabrication lead times that may exceed the 90-day period of performance stated in paragraph 11. Will the Government accept a quoted delivery beyond 90 days after receipt of order where the vendor identifies the lead time in its quotation, or should quoters plan to invoke the 14-day notification provision in paragraph 11 after award? The facility has indicated either is sufficient. Please submit the most accurate delivery schedule possible with your quote. 2. SCOPE OF "ALL WETTED PARTS" Please confirm whether the 316/316L stainless requirement extends to the heat exchanger tube bundle and circulating pump, or whether it applies to the vessel, connections and wetted piping with a copper-alloy tube bundle remaining acceptable. Several standard packaged units meet every other requirement in paragraph 4 but use a copper U-bend coil or bronze circulator. Tube-bundle must be stainless steel, as copper piping is not compatible with low conductivity water. 3. CONTROL VALVE CONFIGURATION Paragraph 4 requires 1/3-2/3 control valves. Please confirm whether the control valves are to be pneumatic, electronic, or vendor's choice, and whether any BAS/BMS interface or signal type is required at the control panel. Electronic controls. BAS interface functionality (integration is not within scope) would be preferable but not required. 4. SOLICITATION NUMBER IN THE DESCRIPTION The first paragraph of the attached OPPORTUNITIES-DESCRIPTION 02 document references "solicitation number 36C25026Q1034" and also refers to providing "a Reverse Osmosis system." The CLIN schedule, Statement of Work, title and submission instructions all reference 36C25026Q1040 and two packaged steam water heaters. Please confirm that 36C25026Q1040 is the correct solicitation number and that the Reverse Osmosis reference is not part of this requirement. Reverse Osmosis system is a different requirement and not associated with 36C25026Q1040, which is limited to the two packaged steam water heaters. Paragraph is hereby corrected to: The contractor shall include all labor, materials, equipment, and shipping to comply with all applicable federal, state, local laws and regulations, and VA regulations as required to provide two packaged steam water heaters as outline in the SOW/SCHEDULE.: 5. INSTALLATION SOW paragraph 3 states that equipment install and testing are not within the scope of this contract. Please confirm that the vendor's responsibility ends at delivery to the Building 23 Warehouse with cut sheets and O&M manuals furnished, and that no rigging, setting, startup or commissioning labor is to be priced. Correct, install and setup is not required. 6. PAST PERFORMANCE Please confirm the number of past performance references desired, the relevancy period, and whether commercial references are acceptable alongside federal references. Past performance can be reviewed via CPARS. There is no specific number of references required. 7. EXISTING EQUIPMENT If available, please provide the make and model of the existing end-of-life units being replaced, and any connection sizes or physical envelope constraints in the Sterile Processing mechanical space, so that quoted units can be confirmed as a fit. Current system is an electric tank-based water heater at end of life. New water heater is being installed parallel to existing prior to cut over. Physical constraints limited to passage through standard height (84 inch) double door.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Apr 30, 2025

NAICS

333415

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Christopher A. Callihan
Contracting Officer
Fax: N/A

Documents

Files (3)

  • 36C25026Q1040_1.docx

    17 KBAdded in Combined Synopsis/Solicitation version 2Posted
    Download
  • OPPORTUNITIES-DESCRIPTION 02.docx

    60 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download
  • 36C25026Q1040.docx

    18 KBAdded in Combined Synopsis/Solicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/Solicitation

    4420--SPS Steam Water Heater (Equipment) - VAMC Chillicothe

    Notice 8b809650f53d45d286147f131f665f0c on SAM.gov

  2. 2
    Version 2Combined Synopsis/SolicitationCurrent

    4420--SPS Steam Water Heater (Equipment) - VAMC Chillicothe

    Notice 79b052a383134b7c8e3dc9c418e3bd13 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
JUSTIFICATION
-Sole Source / J&AOpen
Proposed procurement for NSN 2930010881170 PUMP ASSEMBLY: Line 0001 Qty 1 UI AY Deliver To: DLA DISTRIBUTION SAN DIEGO By: 0300 DAYS ADO Approved source is 7PZX0 16205340. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.
-Combined Synopsis11/16/2026
Proposed procurement for NSN 2930010881170 PUMP ASSEMBLY: Line 0001 Qty 3 UI AY Deliver To: W1A8 DLA DIST SAN JOAQUIN By: 0271 DAYS ADO Approved source is 7PZX0 16205340. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.
-Combined Synopsis11/16/2026
Proposed procurement for NSN 2930010881170 PUMP ASSEMBLY: Line 0001 Qty 2 UI AY Deliver To: W1A8 DLA DIST SAN JOAQUIN By: 0286 DAYS ADO Approved source is 7PZX0 16205340. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.
-Combined Synopsis11/16/2026
Proposed procurement for NSN 2930014208624 COOLER,LUBRICATING OIL: Line 0001 Qty 187 UI EA Deliver To: DLA DISTRIBUTION ANNISTON By: 0318 DAYS ADO Line 0002 Qty 1 UI EA Deliver To: DLA DISTRIBUTION ANNISTON By: 0090 DAYS ADO All responsible sources may submit a quote which, if timely received, shall be considered. Quotes may be submitted electronically.
-Combined Synopsis11/09/2026

Additional Details

Solicitation Number

36C25026Q1040

Archive Date

Oct 23, 2026

Office Address

DAYTON, OH, 45428