GovChime
Notice ID: 403572b9221f4c3ca3fb78b3d8d2e86fAward NoticeAwarded

H335--Underground Storage Tank Inspection Services 09/01/2024 -08/31/2025

Awarded on September 1, 2024. Full description on SAM.gov.

Awarded tounder 36C25224P0832 (source: SAM.gov award notice)• $183.8K

Overview

Posted
August 6, 2024
Notice type
Award Notice
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
541620: Environmental Consulting Services
Agency
Department of Veterans Affairs

Notice details

Office
252-NETWORK CONTRACT OFFICE 12 (36C252)
Place of performance
CAPTAIN JAMES A LOVELL FHCC 3001 GREEN BAY RD, NORTH CHICAGO, 60064
Last updated
Dec 3, 2025
Award date
Sep 1, 2024
Award amount (SAM.gov award notice)
$183.8K

Identifiers

Solicitation number
36C25224Q0542
Notice ID
403572b9221f4c3ca3fb78b3d8d2e86f
Award number (PIID)
36C25224P0832

Description

UNDERGROUND STORAGE TANK INSPECTION SERVICES

Full description on SAM.gov

Award Overview

Award Number

36C25224P0832

Award Amount (SAM.gov award notice)

$183.8K

Award Date

Sep 1, 2024

Awardee

Awardee UEI

YV1UGLKJE4Y6

Original Solicitation

Notice ID: 403572b9221f4c3ca3fb78b3d8d2e86f

Posted Date: Aug 6, 2024

Original Response Deadline: Not specified

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C25224Q0542
  1. Pre-Solicitation
  2. Solicitation
  3. Awarded

This opportunity has been awarded.

  1. Pre-SolicitationJun 10, 2024

    H335--NEW Base+4 Underground Storage Tank Service/Inspection (UST)

    Notice 4743d8b6d5d547be936c916768440a54 on SAM.gov

  2. SolicitationJun 10, 2024

    H335--NEW Base+4 Underground Storage Tank Service/Inspection (UST)

    Notice ac95fe99e891416b8642b44792592b3e on SAM.gov

  3. AwardedCurrentAug 6, 2024

    H335--Underground Storage Tank Inspection Services 09/01/2024 -08/31/2025

    Notice 403572b9221f4c3ca3fb78b3d8d2e86f on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
-AwardedOpen
-Combined Synopsis11/12/2026
The answers to all questions will be posted on 12/15/2026. No new questions will be accepted. Bid due date has been extended to 12/22/2026 at 10:00AM Pacific time zone.
-Combined Synopsis12/22/2026
The purpose of this modification (#1) is to answer questions: Question 1: Typically, VPIH means Veterans Professional Industrial Hygienist which generally falls under NAICS code 541620 (Environmental Consulting). Could you please clarify what your definition of VPIH is and why you chose 562910 (Remediation Services). Answer: The NAICS code is changed to 541620 (Environmental Consulting). Question 2: The Scope of Work appeared rather vague in what the duties of the VPIH would be "VPIH firm to provide VPIH Services for construction project 657A4-21-800" Based on my experience as VPIH, that means overseeing asbestos abatement activities, visual inspections, air clearance sampling, etc. Could you please provide more details on what you envision the VPIH duties entailing. Answer: Here are more details about the project. Full details will be provided in the request for proposal to the top firm. - The VA Professional Industrial Hygienist (VPIH) shall provide all labor, materials, equipment and supervision necessary to review abatement personnel s documentation compliance monitoring, Phase Contrast Microscopy (PCM) air monitoring & analysis, inspections, clearance testing, and removal activities for the duration of the abatement as required by the project plans and specifications. - Asbestos/Lead abatement project oversight work will be performed in separate locations in Building 1 based on design documents. - The VPIH shall provide a final report for each location, at the end of the Asbestos Containment Material (ACM) abatement, which includes a summary of pre-abatement and post-abatement activities. - All routine air sample results shall be delivered to the Contracting Officer s Representative (COR) within 24 hours of collection. All clearance samples shall be delivered to the COR within 24 hours from the collection. Question 3: Generally Consulting services, if this is for a VPIH, do not require an SF 330 submittal. Could you please explain why this is apparently requiring an SF 330 submittal directed at A/E firms. Answer: This project is being solicited as an A/E project. Therefore, SF 330s are required. -----------------------END------------------------
-Pre-Solicitation11/02/2026
The Veterans Health Administration, Network Contracting Office 02 intends to solicit from a single source IAW FAR 13.106(b) to obtain a contract for: It s Five-Year Review, Evaluation, and Update of the Spill Prevention, Control, and Countermeasure (SPCC) Plan for the VA Hudson Valley Health Care System (VAHVHCS) at Castle Point Campus (CPC) and Montrose Campus (MC). The SPCC program is a regulatory framework designed to prevent oil discharges into U.S. navigable waters and adjoining shorelines by requiring facilities to implement prevention, control, and response measures. The VA Hudson Valley Health Care System is mandated by 40 CFR 112.5(b) to review and evaluate its SPCC Plans for Castle Point Campus and Montrose Campus every five years. The last update to the SPCC Plan was completed in 2021. Period of Performance (POP) (estimated): 10/22/2026 through 09/30/2027 with provision of (0) option years. All work to begin immediately upon receipt of a contract. Requirement Description: The Spill Prevention, Control, and Countermeasure (SPCC) Plan must be a written, management-approved document detailing procedures, control measures, and countermeasures to prevent and respond to oil discharges. The core requirement of such plan includes but is not limited to and must follow good engineering practices and comply with 40 CFR Part 112 regulations, or provide equivalent environmental protection if deviations are necessary (40 CFR 112.7, 112.3) Certification: Plans must be certified by a licensed Professional Engineer (PE) unless the facility qualifies for self-certification under the qualified facility criteria. Certification ensures that the plan meets regulatory and engineering standards (40 CFR 112.3, 112.7) Plan Content: SPCC Plans must address three main areas: Operating Procedures: Procedures to prevent oil spills during normal facility operations, including handling, storage, and transfer of oil Control Measures: Physical containment systems such as dikes, berms, retaining walls, curbing, drip pans, sumps, collection systems, drainage systems, weirs, booms, spill diversion ponds, retention ponds, or sorbent materials to prevent oil from reaching navigable waters or shorelines Countermeasures: Procedures to detect, contain, clean up, and mitigate oil discharges, including manpower, equipment, and materials needed for rapid response Inspections, Testing, and Records: Facilities must conduct regular inspections and tests of oil storage containers, valves, and piping. Records of inspections, tests, and maintenance must be kept for at least three years. Personnel must be trained in SPCC procedures, discharge prevention, and applicable environmental regulations Security Measures: The plan must describe how the facility secures oil handling areas, master flow and drain valves, starter controls, and loading/unloading connections to prevent unauthorized access and vandalism. Loading/Unloading Racks: For tank car or tank truck operations, containment systems must hold at least the maximum capacity of a single compartment, and drainage systems must prevent uncontrolled discharges. Amendments and Updates: SPCC Plans must be reviewed and amended as necessary to reflect changes in facility operations, equipment, or regulatory requirements. New facilities must prepare and implement a plan before beginning operations, while existing facilities must maintain and update their plans to ensure compliance. Proposed Source: FIRST ENVIRONMENT 10 Park Place | bldg. 1A, Suite 504 Butler, NJ 07405 The Contracting Officer (CO) has determined after market research that there does not appear to be another certified SDVOSB that can meet the emergent need of the facility to get the requirement complete to meet the deadline outlined without unacceptable risk. Therefore, the most suitable and responsible course of action is to sole source this requirement to First Environment a certified SDVOSB, to ensure continuity of regulatory compliance, operational reliability, and to meet the facilities need of meeting the requirements of 40 CFR 112.5(b). Place of Performance: VA Hudson Valley Health Care System (VAHVHCS) at: Castle Point Campus (CPC) Montrose Campus (MC) The NAICS code for this requirement is: 541620 Environmental Consulting Services (Size Standard: $19.0 Million). Intended Source: FIRST ENVIRONMENT THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, interested parties may identify their interest and capability to respond to this requirement by : Wednesday October 21st 2026 at 16:00 Eastern Standard Time (EST). The Department of Veterans Affairs will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses from responsible sources will be considered. Any prospective contractor must be registered in the System for Award Management (SAM) to be eligible for award. Interested parties are encouraged to furnish information by email only with RESPONSE TO INTENT TO SOLE SOURCE Spill Prevention, Control, and Countermeasure (SPCC) in the subject line. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Contract Specialist, Jason M. Rundle at jason.rundle@va.gov. The capability documentation should include general information and technical background describing in detail the prospective contractor's capabilities and experience that will demonstrate the ability to support these requirements. Page 1 of Page 2 of 2 Page 1 of
-Special Notice10/21/2026

Additional Details

Solicitation Number

36C25224Q0542

Archive Date

Aug 21, 2024

Office Address

MILWAUKEE, WI, 53214