GovChime
Notice ID: 4d26fe0edb504baa83c4d2107e7126bcAward NoticeAwardedArchived

H339-- (Base year) - Elevator Inspection services Danville, IL VAMC

Awarded on October 1, 2025. Full description on SAM.gov.

Awarded tounder 36C25226P0023 (source: SAM.gov award notice)• $4.0K

Overview

Posted
October 1, 2025
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
541350: Building Inspection Services
Agency
Department of Veterans Affairs

Notice details

Office
252-NETWORK CONTRACT OFFICE 12 (36C252)
Place of performance
61832
Last updated
Nov 7, 2026
First published
Last updated on SAM.gov
Award date
Oct 1, 2025
Award amount (SAM.gov award notice)
$4.0K

Identifiers

Solicitation number
36C25225Q0700
Notice ID
4d26fe0edb504baa83c4d2107e7126bc
Award number (PIID)
36C25226P0023

Description

Safety inspection services for the elevators at the VA Illiana Healthcare systems campus located at 1900 East Main Street. Danville, IL 61832.

Full description on SAM.gov

Award Overview

Award Number

36C25226P0023

Award Amount (SAM.gov award notice)

$4.0K

Award Date

Oct 1, 2025

Awardee

Awardee UEI

QPAGHJXJLHM9

Awardee CAGE Code

8LPQ9

Awardee Address

AUGUSTA, GA 30909, GA

Original Solicitation

Notice ID: 4d26fe0edb504baa83c4d2107e7126bc

Posted Date: Oct 1, 2025

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C25621P0369
    SOUTHCO SERVICES LLC
    Department of Veterans AffairsNAICS 541350
    $86.7KSigned Nov 10, 2026
  • 36C24626P0013
    SOUTHCO SERVICES LLC
    Department of Veterans AffairsNAICS 541350
    $18.4KSigned Oct 1, 2026
  • 36C25026P0595
    SOUTHCO SERVICES LLC
    Department of Veterans AffairsNAICS 541350
    $6.4KSigned Aug 21, 2026
  • 36C25026P0595
    SOUTHCO SERVICES LLC
    Department of Veterans AffairsNAICS 541350
    $12.8KSigned Aug 20, 2026
  • 36C24725P0155
    SOUTHCO SERVICES LLC
    Department of Veterans AffairsNAICS 541350
    $32.4KSigned Aug 5, 2026

Contacts

Contracting Officer

Primary Contact

Makena James
Contract Specialist

Documents

Files (1)

  • 36C25226P0023_1.docx

    13 KBAdded in Award Notice version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Award NoticeArchivedCurrent

    H339-- (Base year) - Elevator Inspection services Danville, IL VAMC

    Notice 4d26fe0edb504baa83c4d2107e7126bc on SAM.gov

Other notices for this solicitation

  1. SolicitationRelated noticeSep 9, 2025

    Elevator safety inspection services at the Danville, IL VAMC

    Notice c274a1d44d3c4ea3a382e6d6937f4a33 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
SOURCES SOUGHT SYNOPSIS The Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support a requirement for Elevator Testing Services located at FHCC VAMC , North Chicago IL. o Captain James A. Lovell Federal Health Care Center, North Chicago, IL. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 341350. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Background: The purpose of this Contract is to provide for the inspection/testing of the vertical transportation system located at the Captain James A. Lovell Federal Health Care Center ( FHCC ), 3001 Green Bay Road, North Chicago, IL 60064-3048, as set forth in this Performance Work Statement. A complete listing of all vertical transportation system components, including thirty-one (31) elevators, two (2) cart lifts, and two (2) dumbwaiters (collectively VTS components ), is set forth in the Vertical Transportation System Schedule at the end of this Performance Work Statement. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Schedule at price(s) consistent with the current Price Schedule. A complete listing of all VTS Components, including twenty-nine (31) elevators, two (2) cart lifts, and two (2) dumbwaiters, is set forth in the Vertical Transportation System Schedule at the end of this Statement of Work. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Inventory at price(s) consistent with the current Price Schedule. If your organization has the potential capacity to perform these contract services, please provide the following information: 1) Organization name, address, email address, website address, if applicable, telephone number, and size and type of ownership for the organization; and 2) Tailored capability statements addressing the particulars of this effort and documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements. The Government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 10:00AM Local Time (Central) on November 11th, 2026. All responses under this Sources Sought Notice shall be emailed to Michelle.Klug2@va.gov. STATEMENT OF WORK Inspections Overview: The Contractor shall perform Annual Category 1, Semiannual, and Full-Load Category 5 VTS component inspection/testing as follows: a. Annual Category 1 inspection/testing is typically conducted in May of each year; a. Semiannual inspection/testing is typically conducted in November of each year; and b. Full-Load Category 5 testing will be performed in November 2027. c. Note: Typical inspection/testing dates are subject to change, in FHCC s sole discretion. Basic Contractor Responsibilities: The Contractor shall provide all personnel, equipment, material, parts, software, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract. Any work found to be non-conforming to the terms of this Contract shall be promptly corrected by the Contractor at no additional cost to the Government. All work shall be performed in a neat and professional manner, including the removal of all trash and debris at the completion of all work. Contractor Limitations: The Contractor performing inspection/testing under this Contract is prohibited from performing any repairs or other work on any of the VTS components covered by this Contract. Safety: All work performed under this Contract shall conform to such safety precautions as the FHCC Fire/Safety and Engineering Departments determine, in their sole discretion, to be necessary, in addition to all other requirements set forth elsewhere in the Contract. Inspection/Testing Standards. 1. All inspection/testing of FHCC s vertical transportation system components shall comply with the most current version of the following standards: a. American Society of Mechanical Engineers ( ASME ) 17.1: Handbook on Safety Code for Elevators and Escalators; b. ASME 17.2: Guide for Inspection of Elevators, Escalators, and Moving Walks; c. ASME 17.3: Safety Code for Existing Elevators and Escalators; d. National Fire Protection Association ( NFPA ) 70: National Electrical Code; and e. NFPA 70E: Standard for Electrical Safety in the Workplace. 2. During any inspection/testing, parts shall be removed and equipment cleaned, as necessary, to determine their exact condition. All parts shall be properly reinstalled after removal. 3. All inspections shall be performed in the presence of an elevator maintenance technician, currently under contract as the VA elevator maintenance contractor, and the COR or designated FHCC representative. 4. Immediately following the conclusion of each inspection/testing, the Contractor shall brief the COR or designated FHCC representative regarding the inspection/testing results, including without limitation: code violations, safety concerns, and immediate maintenance needs. 5. The COR, in the COR s sole discretion, may reject any work performed under this Contract that is noncompliant with any of the requirements set forth in this Contract. All rejected work shall be corrected as quickly as reasonably possible at no additional expense to the Government. Inspection Checklists: The Contractor shall provide a fully completed inspection checklist applicable to each VTS component using the Checklist for Inspection of Electric Elevators The comments section of each checklist shall include a. If the VTS component is safe operating condition; a. If the VTS component will perform in accordance with Original Equipment Manufacturer ( OEM ) standards; b. Whether the VTS component has been altered, except in conformity with all applicable standards set forth in this Contract; c. If the VTS component has any deficiencies, referencing the appropriate standard as applicable; and d. Whether there are any recommended VTS component repairs or upgrades. e. Documentation. Upon completion of the inspection/testing of all FHCC s VTS components, the Contractor shall provide a report within thirty (30) days to the COR and other FHCC personnel as directed. The report shall be electronically submitted in pdf format utilizing word processing to the maximum extent practicable; individual file size shall not exceed 7 MB. Each report should include: Certificates of Inspection: The Certificate of Inspection for each VTS component shall include the following information: a. Location (building and city/state); a. Identification number; b. Capacity; c. Speed; d. Date of inspection; e. Name of inspector and company; f. Inspector s signature; and g. Inspector s Qualified Elevator Inspector ( QEI ) number. Scheduling Inspection/Testing: The Contractor shall coordinate a mutually agreeable time with the COR at least thirty (30) days prior to the typical inspection months, as defined above. Hours for Inspection/Testing: All work performed under this Contract shall be performed during normal hours of facility operation, as defined below, except for inspection/testing that, in the COR s judgment, may severely impact elevator service. Inspection/testing that severely impacts elevator service shall be conducted after normal hours of facility operation at no additional cost to the Government. Reinspection: If any VTS component(s) require reinspection, the Contractor shall: a. Provide a quote to the COR for the reinspection(s) at a price consistent with the Price Schedule s Unit Price for the current contract period; and a. Coordinate reinspection(s) with the COR only after a Contract Modification has been awarded authorizing such reinspection. b. Inspector Qualifications. Inspectors performing VTS component inspection/testing under this Contract shall be a currently certified Qualified Elevator Inspector by an ASME-accredited organization, in accordance with ASME QEI-1: Standard for the Qualification of Elevator Inspectors. Inspectors performing work under this Contract shall be regularly employed by the Contractor. The Contractor shall provide a copy of each inspector s QEI-1 certification to the COR prior to any VTS component inspection/testing being performed. c. Scheduling. d. On-Site Work Requirements. In addition to any other requirements set forth in this Contract, the Contractor shall comply with the following on-site work requirements: Contractor Orientation/Training: The Contractor shall attend an orientation prior to beginning any work under this Contract, at the COR s discretion. This orientation may include the following topics: Contract terms and conditions; performance monitoring; badging procedures; safety; fire procedures; severe weather procedures; disease transmission; infection control; disaster procedures; and any other topic deemed necessary by the COR. At the COR s discretion, the Contractor may be responsible for providing some or all this information/training to its employees, as directed by the COR. Check-in/Check-out Requirements: The Contractor shall comply with all facility check-in and screening requirements. Upon successful completion of the facility s check-in and screening process, the Contractor shall check-in with the COR, or the COR s designee, advising them of the nature and location of the work to be accomplished. The Contractor shall check-out with the COR, or the COR s designee, at the conclusion of such work, prior to departing the VA facility, advising them of the work completed and any problems/issues identified. Hours of Operation: Normal hours of facility operation ( Business Hours ) are Monday through Friday, 7:00 a.m. 3:30 p.m. Local Time, except for the following Federal Holidays: a. New Year s Day; a. Birthday of Martin Luther King, Jr.; b. Washington s Birthday; c. Memorial Day; d. Juneteenth National Independence Day; e. Independence Day; f. Labor Day; g. Columbus Day; h. Veterans Day; i. Thanksgiving Day; j. Christmas Day; **** Any other day declared a Federal Holiday by Presidential Proclamation**** Noninterference with Facility Functions: The Contractor shall perform its services under this Contract in a manner that does not interfere with the facility s functions, including maintaining all tools and equipment in an orderly fashion and cleaning the work area at the conclusion of a service visit. The Contractor shall interrupt its work at any time to not interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of facility patients, personnel, equipment, and carts. In the event of an emergency, Contractor MANUFACTURER TYPE ELEVATOR # LOCATION Inspection Frequency 1 SMARTRISE/HW TRACTION P-1 BLDG. 133 CA Annual May/Semi-Annual November 2 SMARTRISE/HW TRACTION P-2 BLDG. 133 CA Annual May/Semi-Annual November 3 SMARTRISE/HW TRACTION P-3 BLDG. 133 CA Annual May/Semi-Annual November 4 MID-AMERICAN TRACTION P-4 BLDG. 131 Annual May/Semi-Annual November 5 MID-AMERICAN TRACTION P-5 BLDG. 131 Annual May/Semi-Annual November 6 SMARTRISE/HW TRACTION P-7 BLDG. 133 Annual May/Semi-Annual November 7 SMARTRISE/HW TRACTION P-8 BLDG. 133 Annual May/Semi-Annual November 8 SMARTRISE TRACTION P-10 BLDG. 134 Annual May/Semi-Annual November 9 SMARTRISE TRACTION P-11 BLDG. 134 Annual May/Semi-Annual November 10 SMARTRISE TRACTION P-13 BLDG. 135 Annual May/Semi-Annual November 11 SMARTRISE TRACTION P-18 BLDG. 1 Annual May/Semi-Annual November 12 MID-AMERICAN HYDRAULIC P-20 BLDG. 46 Annual May/Semi-Annual November 13 MID-AMERICAN TRACTION P-21 BLDG. 66 Annual May/Semi-Annual November 14 MID-AMERICAN TRACTION P-22 BLDG. 7 Annual May/Semi-Annual November 15 MID-AMERICAN HYDRAULIC P-23 BLDG. 4 Annual May/Semi-Annual November 16 MID-AMERICAN HYDRAULIC P-24 BLDG. 133 Annual May/Semi-Annual November 17 SCHUMACKER ELEVATOR HYDRAULIC P-25 PARKING GARAGE 195 Annual May/Semi-Annual November 18 SCHUMACKER ELEVATOR HYDRAULIC P-26 PARKING GARAGE Annual May/Semi-Annual November 19 SCHUMACKER ELEVATOR HYDRAULIC P-1 BLDG. 133EF Annual May/Semi-Annual November 20 SCHUMACKER ELEVATOR HYDRAULIC P-2 BLDG. 133EF Annual May/Semi-Annual November 21 SMARTRISE HYDRAULIC S-1 BLDG. 133CA Annual May/Semi-Annual November 22 SCHUMACKER ELEVATOR HYDRAULIC S-1 BLDG. 133EF Annual May/Semi-Annual November 23 SCHINDLER HYDRAULIC S-2 BLDG. 6 Annual May/Semi-Annual November 24 SCHINDLER HYDRAULIC S-3 BLDG. 6 Annual May/Semi-Annual November 25 MID-AMERICAN TRACTION S-6 BLDG. 131 Annual May/Semi-Annual November 26 SMARTRISE TRACTION S-9 BLDG. 133 Annual May/Semi-Annual November 27 SMARTRISE TRACTION S-12 BLDG. 134 Annual May/Semi-Annual November 28 SMARTRISE TRACTION SF-14 BLDG. 135 Annual May/Semi-Annual November 29 KONE TRACTION P-27 PARKING GARAGE 196 Annual May/Semi-Annual November 30 TAC32H HYDRAULIC 556FH-ELEV-001-CO100 CORRIDOR 100 Annual May/Semi-Annual November 31 SMARTRISE HYDRAULIC 5-ELEV-E1-CO101 CORRIDOR 101 Annual May/Semi-Annual November FHCC VERTICAL TRANSPORTATION SYSTEM SCHEDULE ELEVATORS CART LIFTS MANUFACTURER CART LIFT # LOCATION INSPECTION FREQUENCY 1 LIFT-O-MATIC CART LIFT 1 BLDG. 133CA Annual May/Semi-Annual November 2 LIFT-O-MATIC CART LIFT 2 BLDG. 133CA Annual May/Semi-Annual November DUMBWATIERS DUMBWAITER # LOCATION INSPECTION FREQUENCY 1 DUMBWAITER 1 BLDG. 133 Annual May/Semi-Annual November 2 DUMBWAITER 2 BLDG. 133CA Annual May/Semi-Annual November
80%
Market Research11/11/2026
a. The purpose of this amendment is to extend the response deadline to November 17, 2026, at 4:00 p.m.
78%
Combined Synopsis11/17/2026
Elevator Inspection Services at James J. Peters VA Medical Center
76%
Market Research10/23/2026
Elevator Third-Party Inspection and Testing Services BK & SA
76%
Combined Synopsis10/16/2026
General Information This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (Revolutionary FAR Overhual, RFO), as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation is issued as Request for Quote (RFQ) number 15B61827Q00000001. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01. This requirement is a Total Small Business Set-Aside. The associated North American Industrial Classification System (NAICS) code is 541350 (Building Inspection Services), with a small business size standard of $19.0 million. The Product Service Code (PSC) is H339. Requirement & Scope of Work The Federal Bureau of Prisons (BOP), United States Penitentiary (USP) Atwater, intends to award a firm-fixed-price contract for a certified Category 5 (Cat 5) Elevator Safety Test and Inspection. The contractor shall provide all labor, supervision, materials, equipment, and certified expertise necessary to perform the full-rated load and speed safety testing (Cat 5) in strict compliance with ASME A17.1, state, and federal safety regulations. Core Deliverables: Perform full-load, full-speed safety testing (Category 5) on all designated vertical transportation equipment inside USP Atwater. Provide a certified, independent Qualified Elevator Inspector (QEI) to witness and sign off on all testing. Furnish all necessary certified test weights, rigging, and specialized tools required to perform the test. Deliver a comprehensive inspection report detailing all test results, code compliance findings, and any noted deficiencies within 5-10 business days of test completion. Institutional Security Requirements (USP Atwater) The performance of this contract takes place within a high-security federal penitentiary. The contractor must strictly adhere to all USP Atwater institutional security regulations: Background Clearances: All contract personnel must pass a comprehensive NCIC background check. Aprrox 3-5 Business days. Tool Control: All tools, equipment, vehicles, and test weights brought onto the reservation will be subject to thorough inventory, search, and strict tool control procedures at the rear gate entrance. Any missing tools will result in an immediate facility lockdown. Contraband: Cell phones, personal electronics, cameras, weapons, and drugs are strictly prohibited. Contractors may not bring personal items inside the secure perimeter. Each quote can be one lump sum as long as the objectives listed in the SOW are met. The target completion date of this inspection will be Dec 31, 2026, or as soon as we can get the inspection scheduled. Evaluation & Award Award will be made to the responsible offeror whose quote represents the Lowest Price with Past Performance considered. Submission Instructions Interested small businesses must submit their written quotes via email to John Ridgeway j3ridgeway@bop.gov no later than 11/06/2026 at 09:00 PST]. Quotes must include: Company Information: Name, address, SAM.gov Unique Entity ID (UEI), and point of contact. Pricing: A line-item, firm-fixed-price quote for the full scope of work. Certifications: Proof of current QEI (Qualified Elevator Inspector) certification for the personnel performing/witnessing the test. All questions regarding this solicitation must be submitted in writing to the email address above no later than 11/02/2026.
73%
Combined Synopsis11/06/2026

Additional Details

Solicitation Number

36C25225Q0700

Archive Date

Oct 31, 2025

Office Address

MILWAUKEE, WI, 53214