Notice ID: ead0f019be504169bc4c155e305f2312Sources SoughtArchived
6515-- BioMed Weight Cart Modification to extend the response date to 11/21/25 8:00 am Central Time
Archived on December 21, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 8:00 AM CST
- Posted
- November 14, 2025
- Notice type
- Sources Sought
- NAICS
- 339113: Surgical Appliance and Supplies Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 252-NETWORK CONTRACT OFFICE 12 (36C252)
- Place of performance
- VA Illiana Health Care System 1900 E. Main St.
- Last updated
- Nov 6, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C25226Q0086
- Notice ID
- ead0f019be504169bc4c155e305f2312
Description
This is a modification to extend the response date out to 21/NOV/2025 8 am central standard time.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Lifecycle
- 1Version 1Sources SoughtArchived
6515--Sources Sought BioMed Weight Cart Sources Sought for the Danville, IL VAMC
- 3Version 3Sources SoughtArchivedCurrent
6515-- BioMed Weight Cart Modification to extend the response date to 11/21/25 8:00 am Central Time
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Revision: 01 Effective Date: 11/15/2024 Acquisition ID#36C252-27-AP-0957 Page 1 of 2 Please note that this is not a request for proposal nor a request for quote as there is no solicitation document available. Therefore, this is a notice of intent issued by the Department of Veterans Affairs to negotiate a limited source contract with Iramed Corporation. DEPARTMENT OF VETERANS AFFAIRS Justification for Single Source Awards RFO FAR 12.102 For Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K) Acquisition Plan Action ID: 36C252-27-AP-0957 Contracting Activity US Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) VISN 12 115 S. 84th Street Milwaukee, WI 53214 2237: 556-27-1-2993-0011 Brief Description of Supplies/ Services required and the intended use/Estimated Amount: The Captain James A. Lovell Federal Healthcare Center (FHCC), Building 556, Nursing Services, is requesting the acquisition of one MRI-compatible IV infusion pump system for the Intensive Care Unit (ICU). MRI-compatible infusion pumps are medically necessary for ICU patients who require continuous vasoactive or sedative titratable infusions while undergoing magnetic resonance imaging (MRI) to support the diagnosis and evaluation of complex disease processes. Estimated Amount: $105,270.20 Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used: The availability of this equipment will enable FHCC to perform medically necessary MRI examinations on-site, reducing the need to transfer patients to outside facilities. Currently, these patients are often taken for CT scans; however, CT imaging may not provide the comprehensive diagnostic information required for certain conditions Standardization and compatibility with the MRI IV infusion equipment currently installed at the facility are essential requirements for this acquisition. The requested system is intended to integrate with the existing equipment and support established clinical workflows, training, maintenance, and operational procedures. Substituting products from another manufacturer could result in incompatibility, require additional accessories or system modifications, necessitate staff retraining, and increase costs to the facility. Therefore, procurement of the compatible MRI IV Infusion Pump System is justified to maintain system continuity, operational efficiency, and patient-care capabilities. Description of market research conducted and results or statement why it was not conducted: Market Research Findings: An SBA.gov search under NAICS code 339112 identified zero (5) SDVOSBs and (13) VOSBs. Two additional searches were conducted on sba.gov by combining NAICS code 339112 with the keywords Quad Non-Magnetic IV Pump System and Non-Magnetic IV Pump System and applying specific filters for SDVOSBs and VOSBs. Both searches yielded zero (0) results. A search on GSA Advantage using the keywords Non-Magnetic IV Pump System produced several results that does not appear to meet the requirement. The Contracting Officer (CO) searched Google.com using the keywords Non-Magnetic IV Pump System and identified several vendors, including BD, BioSpace, Hospital & Healthcare management, Iradimed, InMed, MDPI, and Ivenix. Although several alternative vendors were identified, their products are not compatible with the MRI IV infusion equipment currently installed at the facility. Standardization and compatibility are essential requirements for this acquisition. The requested system is designed to integrate with the existing equipment and support established clinical workflows, training, maintenance, and operational procedures. Substituting products from another manufacturer could lead to compatibility issues, require additional accessories or system modifications, necessitate staff retraining, and increase facility costs. Therefore, procuring the compatible MRI IV infusion pump system is justified to ensure system continuity, operational efficiency, and uninterrupted patient-care capabilities. CO received a letter of authorization from the vendor that certifies Iradimed Corporation is the sole manufacturer and authorized seller of the MRidium 3870 MRI Infusion System and its accessories. Due to proprietary considerations, Iradimed Corporation is also the exclusive source for replacement parts for the MRidium MRI Infusion Pump System. The MRidium 3870 MRI Infusion System is the only nonmagnetic, MRI-compatible IV infusion pump currently available on the market. Contracting Officer's Certification: Purchase is approved in accordance with RFO FAR 12.102. I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief. Vernise L. Newton Contracting Officer | - | Special Notice | 11/17/2026 |
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Humidifier Heater base, Humidifier Sensor Cartridge, and Humidifier Expiratory Heater to the , Captain James A. Lovell Federal Health Care Center in North Chicago, IL. General Requirements: Brand Name or Equal The below products are known to meet the governments needs all equal parts will be considered. 950 Humidifier Heater base, 950 Humidifier Sensor Cartridge, and 950 Humidifier Expiratory Heater Wire Adapter or Equal Salient Characteristics: Therapy Profiles: Must support Invasive ventilation Must support Noninvasive ventilation Must support Nasal High Flow therapy. Temperature Probes: Must have no external temperature probes Must incorporate internal temperature probes that do not require special disinfection processing Circuit Compatibility: Must be compatible with single heated circuits for non-invasive ventilation. Must be compatible with double heated circuits for invasive ventilation. User Interface: Must have a simple user interface Must include touch screen monitors to create setting modifications Must allow mode changes Must allow comfort setting adjustments Must display and troubleshoot alarms Must provide access to Information and Service menus Alarms: Must have built-in alarms for various conditions including but not limited to: 1. High Temperature alarms 2. Low Temperature alarms 3. Water Out alarms 4. Circuit Disconnect alarms 5. Reverse Gas Flow alarms 6. System check alarms Compatibility: Must be compatible with all ventilation and gas flow delivery devices that is currently used at FHCC, Specifically, must be compatible with Medtronic 980 ventilators Specifically, must be compatible with Philips V60 BiPAP devices Specifically, must be compatible with Nihon Kohden 330, 440, and 550 ventilator systems All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. SAM Unique ID number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Specialist, Ryan Nugent, at Ryan.Nugent@va.gov no later than 8:00 AM (Central Standard Time), 23 November 2026. 36C25227Q0090 950 Humidifier Heaterbase shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided. | - | Market Research | 11/23/2026 |
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of Other than Small Businesses and Small Businesses, including VetCert-certified Veteran-Owned Small Business (VOSB) or Service-Disabled Veteran-Owned Small Business (SDVOSB). The William S. Middleton Memorial Veterans Hospital in Madison, WI has the requirement for a brand name GE Healthcare TEC 850 Anesthesia Vaporizers. The Government is requesting that Other Than Small Businesses and Small Businesses, including VetCert-certified VOSB or SDVOSB sources respond if it can meet the description below on a brand name only basis (GE Healthcare TEC 850 Anesthesia Vaporizers): CLIN Item Description Qty Unit 0001 1177-9850-SEV TEC 850 Sevoflurane Vaporizer 3 EA 0002 1177-8350-000 TEC 850 SEVO Calibrated Assembly 3 EA 0003 M7209012 Easy-Fil Sevoflurance Filler 3 EA 0004 M7209024 TEC 850 SEVO GE 3 EA 0005 2106572-003 Easy-fil Bottle Adapter, Sevoflurane 3 EA 0006 2095452-001 TEC 850 English URM 3 EA 0007 1177-9850-ISO TEC 850 Isoflurane Vaporizer 2 EA 0008 1177-8150-000 TEC 850 ISO Calibrated Assembly 2 EA 0009 M7209011 EASY-FIL Isoflurance Filler 2 EA 0010 M7209022 TEC 850 ISO GE 2 EA 0011 2106572-001 Easy-fil Bottle Adapter, Isoflurane 2 EA 0012 2095452-001 TEC 850 English URM 2 EA Interested Other Than Small Businesses and Small Businesses including VetCert-certified VOSBs and SDVOSBs are required to submit an e-mail delineating: Qualifications, capabilities, and experience for providing this product; Business size/Socioeconomic status; Manufacture location; If the product is on the Federal Supply Schedule or the Open Market; and Memo or correspondence which authorizes distributor to distribute the manufacturer s products (if applicable). This is not a Request for Proposal or an announcement of a solicitation and no solicitation currently exists. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VetCert for set-aside consideration. Responses are to be submitted by e-mail to Patrick Trzeciak at patrick.trzeciak@va.gov. The information requested must be received no later than 3:00 p.m. CDT on 11/06/2026. | - | Market Research | 11/06/2026 |
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The Department of Veterans Affairs (VA) San Diego Healthcare System is seeking sources capable of providing medical grade bed covers equivalent to Stryker IsoTour. The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. Statement of Work: Bed Covers Introduction: The purpose of this Statement of Work (SOW) is to establish a firm fixed-price Blanket Purchase Agreement (BPA) to procure bed covers equivalent to Stryker IsoTour covers for base plus four option years. This requirement is intended to streamline the acquisition of these specific components to ensure the continued operational readiness of medical equipment. Scope of Work: The contractor shall provide the necessary parts as specified in the technical requirements section of this SOW. This is a BPA intended for recurring requirements; the government will issue individual delivery orders against this agreement as need arises during the period of performance. Period of Performance: The BPA shall remain in effect for a base period of one (1) year from the date of establishment, with four (4) optional one-year renewal terms, subject to government funding and performance evaluation. Base: 1/1/2027 12/31/2027 Option Year 1 (OY1): 1/1/2028 12/31/2028 Option Year 2 (OY2): 1/1/2029 12/31/2029 Option Year 3 (OY3): 1/1/2030 12/31/2030 Option Year 4 (OY4): 1/1/2031 12/31/2031 Deliverables: The chart below is estimated quantities for base and all option years; quantities are not a contractual statement of precise quantities that the Government will order. The quantities given are estimated only, and no guarantee of their accuracy is either given or implied. The Government will only pay for quantities that are actually ordered per each delivery order and for which the services are fulfilled. Item Description Base Estimated Quantity OY1 Estimated Quantity OY2 Estimated Quantity OY3 Estimated Quantity OY4 Estimated Quantity Top Covers Equivalent to Stryker IsoTour 63 63 251 63 63 Bottom Covers Equivalent to Stryker IsoTour 63 63 251 63 63 Salient Characteristics: NOTE: All parts must be new, unused, and in their original manufacturer packaging. No refurbished or third-party alternative parts will be accepted. VAAR 852.212-71 Gray Market and Counterfeit Items clause applies on this acquisition. No remanufacturers or gray market items will be acceptable. The contractor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other signed documents from the OEM. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contains the signature of an authorized official for the manufacturer. If the offerors fail to provide a signed letter from the OEM (unless the contractor is the OEM), your quote will not be evaluated for award. If you are the OEM, state so in your quote response. Bed covers shall not void or adversely affect any existing manufacturer warranties applicable to the Stryker Model 2872 IsoTour Gel Support Surface. The contractor shall provide documentation demonstrating compatibility with the OEM mattress system and that use of the replacement cover will not negatively impact warranty coverage. Bed covers shall be fully compatible with the Stryker Model 2872 IsoTour Gel Support Surface and shall fit the existing mattress without modification to the mattress or stretcher system. Bed covers must be medical grade. Bed covers must be fluid-resistant or fluid proof. Bed covers shall permit normal use of all existing mattress attachment mechanisms. Top covers shall be designed to fit IsoTour Gel Support Surface mattresses measuring 78.75" (200 cm) L x 35.5" (90.2 cm) W x and 9.5" (24.1 cm) H. Bottom covers shall be designed to fit mattresses measuring 84.25 (213.9 cm) in L x 35.5" (90.2 cm) W and shall securely interface with the corresponding top cover to maintain intended mattress function and patient support. Schedule: Deliverables shall be provided upon the issuance of a BPA delivery order. The contractor shall provide the following: Order Acknowledgement: Within two (2) business days of receiving the order. Shipping Notification: Including tracking numbers and expected delivery dates. The following delivery addresses are applicable, and the vendor will be instructed where to deliver order. Place of Performance: The contractor will be instructed where to deliver each delivery order. VA San Diego Healthcare System 3350 La Jolla Village Drive San Diego, CA 92161 Delivery hours 7am-3pm M-F, Federal holidays excepted VA Off-Site Warehouse 9755 Birch Canyon Pl, Ste 100 San Diego, CA 92126 Delivery hours: 7am-3pm M-F, Federal holidays excepted Federal Holidays: New Year s Day January 1 Martin Luther King s Birthday 3rd Monday in January Presidents Day 3rd Monday in February Memorial Day Last Monday in May Juneteenth Day June 19 Independence Day July 4 Labor Day 1st Monday in September Columbus Day 2nd Monday in October Veterans Day November 11 Thanksgiving Day 4th Thursday in November Christmas Day December 25th The President of the United States of America may declare additional days as a Federal holiday, and if so, this holiday will automatically be added to the list above. When a holiday falls on a Sunday, the following Monday shall be observed as a Federal holiday. When a holiday falls on a Saturday, the preceding Friday shall be observed as a Federal Holiday. Quality Assurance and Inspection: The government reserves the right to inspect all delivered items. Any parts that arrive damaged, incorrect, or fail to meet the OEM specifications defined in Section 3.0 will be rejected and returned at the vendor's expense. Replacement parts must be provided within ten (10) business days of the rejection notice. Special Instructions Invoicing: Invoices shall be submitted electronically via Tungsten or the designated government payment system, referencing the specific purchase order numbers, which shall be provided on each delivery order. If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SOW requirements. For instances where your company cannot meet the SOW requirement(s), please explain. For instances where your company can meet the SOW requirement(s), please show how your company meets/exceeds each requirement. (2) Please review the list of SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SOW? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained. (15) Does your organization offer a leasing solution? Please elaborate. (16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (19) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, November 20, 2026, by 10 AM Pacific Local Time. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement. | - | Market Research | 11/20/2026 |