GovChime
Notice ID: 394825da195543d085d1c0409f7a1d04Sources SoughtArchived

6515--TONOMETER (Band Name or Equal)

Archived on April 10, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM CDT
Posted
March 4, 2026
Notice type
Sources Sought
NAICS
339112: Surgical and Medical Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
252-NETWORK CONTRACT OFFICE 12 (36C252)
Place of performance
Tomah VA Medical Center, Tomah, Wisconsin, 54660-3105
PSC
6515: MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
Last updated
Nov 2, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25226Q0316
Notice ID
394825da195543d085d1c0409f7a1d04

Description

THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.  The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service-Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide a Brand Name or Equal TONOMETER to the Tomah VA Medical Center 500 E. Veterans Street Tomah, WI 54660-3105.  Brand Name : TONOMETER-II, ARK WITH TONOMETRY DESCRIPTION OF SUPPLIES Manufacturer Manufacturer Part No QUANTITY TONOMETER-II, ARK WITH TONOMETRY NIDEK TONOMETER-II, ARK WITH TONOMETRY 1 General Requirements: Salient Characteristics: (Brand Name or Equal) Refraction measurement range must be no less than -30.00D TO +25.00D (Spherical) and 0.00D to ±12.00D (cylindrical) Keratometry measurement range must be no less than 5.00mm to 13.00mm in radius curvature Intraocular Pressure Range shall be From 7mm to 60mmHg Axis SHALL BE NO LESS THAN 0° to 180° (1°/5° increments) Minimum Measurable Pupil Diameter SHALL NOT BE LESS THAN 2mm Radius Curvature Range must be no less than 5.00 to 13.00mm (0.01mm increments) Corneal Refractive Power shall not be less than 25.96D to 67.50D (n=1.3375), (0.01/0.12/0.25D increments) Must be able to Auto Track & Automatic Data Capture X-Y-Z direction, Automatic Data Capture PD Measurable range no less than 30.00mm to 85.00mm (indication increments: 1mm) Corneal Size (CS) range shall be no less than 8.1mm 14.6mm (indication increments: 0.1mm) Pupil Size (PS) range shall be no less than 0.8mm 12.1mm (indication increments: 0.1mm) NON-CONTACT TONOMETER: Must be able to measure from 1mm Hg to 60mm hg Working distance no less than 11.0mm Must include inner fixation light All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. UIE number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.  Submit responses to the Contracting Specialist, Waymon McNeal, at Waymon.McNealjr@va.gov no later than 3:00 PM (Central Standard Time), 11 March 2026.  36C25226Q0316 TONOMETER shall be referenced on all correspondence regarding this announcement.   TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.  The NAICS Code 339112 Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.  Â

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Waymon McNeal
Contracting Officer

Documents

Files (1)

  • 36C25226Q0316.docx

    28 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    6515--TONOMETER (Band Name or Equal)

    Notice 394825da195543d085d1c0409f7a1d04 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C25226Q0316

Archive Date

Apr 10, 2026

Office Address

MILWAUKEE, WI, 53214