Notice ID: 406eb5b940af4a8fac36cebf03901f4fSolicitationArchived
ULTRASOUND
Archived on August 5, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 10:00 AM CDT
- Posted
- July 7, 2026
- Notice type
- Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business Set Aside
- NAICS
- 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 252-NETWORK CONTRACT OFFICE 12 (36C252)
- Place of performance
- Milwaukee, Wisconsin, 53295
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C25226Q0521_2
- Notice ID
- 406eb5b940af4a8fac36cebf03901f4f
Description
- ELLEX ABSOLU S ULTRASOUND CONSOLE WITH A-STD PROBE (P/N PCBX0037S1S) QTY:1
- ELLEX BIOMETRY A-SCAN PROBE FOR ABSOLU Ground plate w/o filter QTY:2
- ELLEX 15 MHz B PROBE FOR ABSOLU/ABSOLU S QTY:2
- 50 MHz LINEAR HIGH-RESOLUTION PROBE FOR ABSOLU/ABSOLU S SYSTEMS ONLY QTY:1
- STANDARDIZED A PROBE (PROBE ONLY) FOR ABSOLU S MODULES ONLY QTY:5
- ELLEX BOX OF CLEARSCANS QTY:1
- ELLEX DICOM SOFTWARE FOR ABSOLU ULTRASOUND QTY:1
- ELLEX WIRELESS 9 FUNCTION FOOTSWITCH FOR ABSOLU/ABSOLU S QTY:1
- ELLEX ULTRASOUND CART FOR ABSOLU & COMPACT TOUCH 2 QTY:1
- ELLEX ULTRASOUND CLINICAL APPLICATIONS TRAINING QTY:1
Salient Characteristics Brand Name or Equal:
- A-scan Biometry: to verify measurements of the length of the eye (axial length)
- -Immersion A-scan
- -Direct contact A-scan
- -QTY Two (2) Biometry A-scan transducers
- -Auto Axial length average and standard deviation calculations
- -IOL Formulas
- -Lens Database
- -measurement tools
- B-scan
- 15 MHz B-scan probe
- -Qty Two (2) Biometry B-scan transducers
- UBM
- -QTY One (1) UBM Transducer
- -QTY Ten (10) single-use sterile UBM-probe cover devices
- -QTY Six (6) 8-MHz A-scan diagnostic transducers
- allows for: diagnosis of tumor lesions, diagnosis of retinal vitreous membrane detachment and diagnosis of Graves disease
- -probe positioning feedback/visualization
- -Static and dynamic image capture and storage
- -Image Annotation
- -pachymetry probe self-check/auto calibration
- -DICOM networking, compatibility to send to Ziess Forum
- -Footswitch
- -height-adjustable cart with keyboard tray
- -1-day on-site Clinical Applications training to identify sight threatening retinal lesions, such as ocular tumors measurements critical in determining what power lens implant to place in the eye after cataract surgery
- -Sulcus-to-Sulcus measurements
- -corneal thickness measurements
- -IOP correction formulas
- VA Networked Medical Device risk assessment documents:
- VA Directive 6550
- Ports, Protocols, and Security spreadsheet
- Inventory List
- MDS2
- Network Topology Diagram
- Software Bill of Materials
- A Letter of support is required if there is any vendor proprietary firmware, customized OS, or COTS Devices (i.e. NAS, Firewall, switch, HW load balancer, etc.)
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C25226Q0521_2.docx
207 KBAdded in Solicitation version 3Posted
Lifecycle
- 3
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
36C25226Q0521_2
Archive Date
Aug 5, 2026
Office Address
MILWAUKEE, WI, 53214