Notice ID: aa00eb2da4014c409b99af47f6a739d1Award NoticeAwarded
J045--Cooling Tower Annual Preventative Maintenance KC 589C10293
Awarded on July 22, 2021. The description is published on SAM.gov: Full description on SAM.gov.
Awarded tounder 36C25521P0493 (source: SAM.gov award notice)• $815.2K
Overview
- Posted
- October 5, 2021
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Agency
- Department of Veterans Affairs
Notice details
- Last updated
- Sep 9, 2025
- Award date
- Jul 22, 2021
- Award amount (SAM.gov award notice)
- $815.2K
Identifiers
- Solicitation number
- 36c25521q0101
- Notice ID
- aa00eb2da4014c409b99af47f6a739d1
- Award number (PIID)
- 36C25521P0493
Description
No description in the SAM.gov data feed for this notice.
Award Overview
Award Number
36C25521P0493
Award Amount (SAM.gov award notice)
$815.2K
Award Date
Jul 22, 2021
Awardee
Awardee UEI
UVCJNKDN3GU9
Original Solicitation
Notice ID: aa00eb2da4014c409b99af47f6a739d1
Posted Date: Oct 5, 2021
Original Response Deadline: Not specified
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36c25521q0101- Awarded
This opportunity has been awarded.
- AwardedCurrentOct 5, 2021
J045--Cooling Tower Annual Preventative Maintenance KC 589C10293
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
This is a Sources Sought Notice (a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited. (b) Although "proposal," "offeror," contractor, and "offeror" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. (c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as "proprietary" or "confidential," intended to restrict distribution will not be distributed outside of the Government, except as required by law. (d) This Sources Sought is issued by VISN 2 Contracting Office in Bronx, NY for the purpose of collecting information on Petroleum Bulk Storage Tank Maintenance Services at New Jersey Health Care System VA Medical Center, Lyons Campus at 151 Knollcroft Road, Lyons, NJ 07939 and East Orange Campus at 385 Tremont Avenue, East Orange, NJ 07018. The VA is seeking to provide for this requirement as of 09/10/2026 to establish a new service. NAICS Code: 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. PSC Code: J045 Maintenance, Repair, and Rebuilding of Equipment: Plumbing, Heating, and Waste Disposal Equipment. (e) Cursory market research has identified several small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment are encouraged to email a capability statement and full information to Natalie Acevedo at Natalie.Acevedo@va.gov by 8/27/2026 at 12:00 PM ET. (f) Requested Information Interested parties are invited to submit a capability statement including the following: Company name, address, UEI number, and point of contact information Business size and socio-economic status (SDVOSB/VOSB/8(a)/HUBZone/other) NAICS and PSC Codes under which your company typically performs these services Corporate experience and past performance relevant to petroleum bulk storage tank maintenance (last 3 years) List of certifications (OSHA 40 hour, HAZWOPER certificate, NJDEP approved Class A/B operator training certificate) Approximate number of trained personnel available Ability to meet response/turnaround times Any GSA/FSS, VA contract schedules, or other vehicles available (g) Scope of Work: The Contractor shall be responsible for the specified maintenance of the petroleum bulk storage tank systems listed in the tables incorporated in sections (2) and (3) of this scope of work. Maintenance items shall include tank monitoring panels, probes, sensors, thermal printers, alarms, batteries, and all associated components of the tank gauging and leak detection systems. The Contractor shall provide properly trained technicians to service, repair, and/or calibrate tank monitoring systems, probes, and all other accessories in accordance with the manufacturer s instructions and this scope of work. Annual Maintenance Fuel Polishing Fuel Cleaning Monthly Maintenance Triennial Maintenance Triennial Maintenance VA NJ Healthcare System Above, Underground Storage, Day, and Belly Tank Inventory East Orange VA Medical Center Tank No. Location Size (Gallons) A-Tank Underground/Diesel 4,000 B-Tank Underground/Diesel 4,000 C-Tank Underground/Diesel 1,000 CN-Tank Underground/Diesel 15,000 DN-Tank Underground/Diesel 15,000 Building 8 Generator Tank Underground/Diesel 3,000 Building 8 Boiler fuel tank #1 Underground/Diesel 20,000 Building 8 Boiler fuel tank #2 Underground/Diesel 20,000 Building 8 Boiler fuel tank #3 Underground/Diesel 20,000 Building 8 Boiler fuel tank #4 Underground/Diesel 20,000 Building 15 tank Underground/Diesel 3,000 Building 7 Generator Aboveground/Diesel 2,000 A-1 DT Day Tank 275 B-1 DT Day Tank 275 C-Tank Day Tank 250 CN-Tank Belly Tank 1520 DN-Tank Belly Tank 2500 Building 15 tank Belly Tank 531 Building 7 Generator Day Tank 75 Lyons VA Medical Center Tank No. Tank Type/Fuel Type Size (Gallons) 1 Underground/Diesel 1,500 2&9 Underground/Diesel 1,500 3&4 Underground/Diesel 1,500 7&8 Underground/Diesel 1,500 10 Underground/Diesel 2,500 13&14 Aboveground/Diesel 1,500 14-T1 Underground/Diesel 40,000 14-T2 Underground/Diesel 40,000 14-T3 Underground/Diesel 40,000 14-T4 Underground/Diesel 40,000 14-T5 Underground/Diesel 10,000 49-T1 Aboveground/Gasoline 900 49-T2 Aboveground/Diesel 900 49-T3 Aboveground/Diesel 400 49-T4 Aboveground/Diesel 400 53 Underground/Diesel 1,500 54 Underground/Diesel 1,500 57 Underground/Diesel 1,500 135 Underground/Diesel 6,000 136 Underground/Diesel 15,000 141 Aboveground/Diesel 1,500 143 Underground/Diesel 2,500 1 Day Tank 155 2&9 Day Tank 100 3&4 Day Tank 75 7&8 Day Tank 275 10 Day Tank 75 13&14 Day Tank 75 54 Day Tank 75 57 Day Tank 75 135 Belly Tank 1500 136-1 Belly Tank 800 136-2 Belly Tank 800 141 Belly Tank 400 143 Day Tank 100 Storage Tank Monitoring System Inventory East Orange Medical Center Location Device Model Tanks Monitored Vault Omntec Proteus B/K/X TA, TB, TC CN and DN Omntec Proteus B/K/X T1,T2 Building 7 Omntec Proteus B/K/X T1 Building 8 boilers tanks Omntec Proteus B/K/X T1,T2,T3,T4 Building 8 generator Omntec Proteus B/K/X T1 Building 15 Omntec Proteus B/K/X T1 Lyons Va Medical Center Location Device Model Tanks Monitored 1 Generator Veeder-Root TLS-350 Plus T1 2&9 Generator Veeder-Root TLS-350 Plus T1 3&4 Generator Veeder-Root TLS-350 Plus T1 7&8 Generator Veeder-Root TLS-350 Plus T1 10 Generator Veeder-Root TLS-350 Plus T1 13&14 Generator Veeder-Root TLS-350 Plus T1 14 Building Veeder-Root TLS-350 Plus T1, T2, T3, T4, T5 49 Building Veeder-Root TLS-350 Plus T1, T2, T3, T4 53 Generator Veeder-Root TLS-350 Plus T1 54 Generator Veeder-Root TLS-350 Plus T1 57 Generator Veeder-Root TLS-350 Plus T1 135 Generator Veeder-Root TLS-350 Plus T1 136 Generator Veeder-Root TLS-350 Plus T1 141 Generator Veeder-Root TLS-350 Plus T1 143 Generator Veeder-Root TLS-350 Plus T1 | 78% | Market Research | 08/27/2026 |
AMENDMENT TO CORRECT PRICE/COST SCHEDULE. PLEASE SUBMIT OFFERS WITH THIS CORRECT VERSION. RESPONSE TO QUESTIONS. | 75% | Combined Synopsis | 11/09/2026 |
This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, “Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01, dated 03/13/2026 This solicitation is set-aside 100% for SDVOSB. The associated North American Industrial Classification System (NAICS) code for this procurement is 811310, with a small business size standard of $12.5M. The FSC/PSC is J042. The Department of Veterans Affairs, VA Network Contracting Office (NCO) 21 is seeking to purchase Fire Extinguisher Inspection and Maintenance Services. | 67% | Combined Synopsis | 11/09/2026 |
66% | Combined Synopsis | 11/10/2026 | |
PURPOSE: This is a Request for Information(RFI)/Sources Sought announcement only. This is not a solicitation announcement. The NCO 15 Consolidated Mail Outpatient Pharmacy(CMOP), Contracting office is conducting market research only to gain knowledge of potential qualified sources and is issuing this sources sought notice for the procurement of services in support of robotics equipment at the Lancaster CMOP Lancaster, TX: Preventative Maintenance Emergency Repairs Diagnostics Looking for potential vendors who can perform the stated requirement below. Production robots are utilized in placing vials from the automated equipment into Totes for further A-Frame items or de pucking into totes for packing. This process cannot be done by operators, and as such, these Mitsubishi robots are imperative to the overall operations of the facility. Contractor shall provide sufficient, competent, and qualified personnel to perform the necessary routine or preventive maintenance, emergency diagnostics, and repairs of two production floor Mitsubishi robots utilizing proper manufactured specified procedures. Contractor will be responsible for using the most current manufacturer manuals and checklists as needed. - Mitsubishi Industrial Robot Instruction Manual, Robot Arm Setup and Maintenance (RH3FH / RH6FH / RH12FH / RH20FH Series)_MELFA BFP-A8868-E_Copyright 2012 -Appendix A: Mitsubishi Robot Preventive Maintenance Checklist Type of Equip - Make - Model Mitsubishi Robot - Mitsubishi - RH-6FH5520-D1-S13 CONTROLLER - Mitsubishi - CR750-06HD1-1-S13 Mitsubishi Robot - Mitsubishi - RH-6FH5520-D1-S13 CONTROLLER - Mitsubishi CR750-06HD1-1-S13. Offers are not being solicited at this time. The Government does not intend to award a contract on the basis of this request for information. Vendors are required to address the following questions to be considered a viable source for future needs; Have you ever been licensed or certified to work on this type of equipment? Yes or No Can you provide past historical references for this type of service? Yes or No Any responses to this sources sought must include the following information. Your company s POCs: Name Phone Number Email Address Your Company s SAM Unique ID Number Your Company s Capability Statement Interested sources may respond to this notice via email to wade.cunningham@va.gov , on or before October 20th 2026 @ 12:00 p.m. Central. This Request for Information does not obligate VA to the release of a solicitation. ATTACHMENTS: Statement of Work Mitsubishi Industrial Robot Instruction Manual Wage Determination | 65% | Market Research | 10/20/2026 |
Additional Details
Solicitation Number
36c25521q0101
Archive Date
Dec 4, 2021
Office Address