GovChime
Notice ID: 676f2cf02d07464395c908d2ab00ac1fSources Sought

J045--Annual Chiller Maintenance/Repair

Archived on December 17, 2023. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
4:30 PM UTC−05:00
Posted
October 4, 2023
Notice type
Sources Sought
NAICS
811210: Electronic and Precision Equipment Repair and Maintenance
Agency
Department of Veterans Affairs

Notice details

Office
255-NETWORK CONTRACT OFFICE 15 (36C255)
Place of performance
Harry S. Truman VAMC 800 Hospital Dr., Columbia, 65201
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C25523Q0806
Notice ID
676f2cf02d07464395c908d2ab00ac1f

Description

THIS IS NOT A SOLICITATION. This is a Sources Sought (SS) notice issued in accordance with FAR 15.201(e) to conduct market research. This SS is issued solely for information and planning purposes - it does not constitute a Request for Quote (RFQ) or a promise to issue a RFQ in the future. This sources sought does not commit the Government to contract for any supply or service whatsoever. The Department of Veterans Affairs (VA) is not, at this time, seeking quotes and will not accept unsolicited quotes. Responders are advised that the U.S. Government will not pay for any information or administrative costs incurred in response to this SS; all costs associated with responding to this SS will be solely at the interested vendor's expense. Not responding to this SS does not preclude participation in any future RFQ, if any is issued. Any information submitted by respondents to this SS is strictly voluntary. All submissions become Government property and will not be returned. This announcement is based upon the best information available and is subject to future modification. I. OVERVIEW: The Department of Veterans Affairs, Network Contracting Office (NCO) 15, has a requirement to provide full maintenance on site, to include all replacement parts, labor, travel expenses, tools, tests equipment and other incidentals necessary to maintain or restore Chillers #1, #2, #3 and #7 to operating specifications according to the manufacturer s recommendations and provide full maintenance on site, to include all labor, travel expenses, tools, test equipment and other incidentals necessary to maintain Chillers #4, #5 and #6 according to the manufacturer s recommendations; replacement parts are not included for Chillers #4, #5, and #6. Maintenance shall be performed impacting one chiller at a time to allow for continued cooling of the Operating Rooms and Sterile Processing for the Columbia, MO Harry S. Truman VA Medical Center located at 800 Hospital Dr., Columbia, MO 52134 The successful proposer must be able to: Specifications: Chiller Size / Manufacturer Model Serial No. VA No. #1 500 Ton / Trane CVHE500 L97G04950 543EE20979 #2 1000 Ton / Trane CVHF910 L98B01293 543EE20978 #3 1000 Ton / Trane CVHF910 L98B01314 543EE20977 #4 York International YC1V0197EA46VABBXT 2EWM006332 139634 #5 York International YC1V0197EA46VABBXT 2EWM006333 139635 #6 York International YLAA00946XCAS 2EWM006379 139636 #7 1200 Ton / Trane CVHF130 L13E0228 543EE155597 Statement of Work below. II. VETERANS FIRST CONTRACTING PROGRAM: The Dept. of Veteran s Affairs is dedicated to the Veterans First Contracting Program and encourages any certified Service-Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB) capable of furnishing the required services to respond. In accordance with Veterans Affair Acquisition Regulation (VAAR) sections 819.7005 and 819 7006, if a sufficient number of eligible SDVOSB or VOSB firms are identified during market research the acquisition will be set-aside for SDVOSB or VOSB participation. III. INFORMATION REQUESTED FROM INDUSTRY: Please submit your response (capability statement) in accordance with the following: 1) No more than 3 pages (excluding transmittal page). Include the name, email address and phone number of the appropriate representative of your company; 2) Address if your firm has the capability to perform the services listed above; 3) Address how long it would take from the date of contract award for you to commence furnishing services; 4) Indicate whether your company, subcontractors, teaming partners, joint ventures have a Federal Socio-Economic status, e.g., Small Business, Service-Disabled Veteran Owned Small Business, Veteran Owned Small Business, Woman-Owned Small Business, Disadvantaged Small Business, and Hub Zone. 5) If Service- Disabled or Veteran Owned Small Business, is your company and/or partners registered in VA s VetBiz repository? 6) Mark your response as Proprietary Information if the information is considered business sensitive; 7) NO MARKETING MATERIALS ARE ALLOWED IN RESPONSE TO THIS SS. The Government will not review any other information or attachments included, that are in excess of the 3-page limitation. Submit your response via email to Laura.Ferguson@va.gov Submit your response by 4:30 P.M. Central Time on October 18, 2023. DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER Truman VA, Columbia, MO STATEMENT OF WORK Maintenance and Repair of Chillers 1. Introduction: a. The contractor shall provide full maintenance on site, to include all replacement parts, labor, travel expenses, tools, tests equipment and other incidentals necessary to maintain or restore Chillers #1, #2, #3 and #7 to operating specifications according to the manufacturer s recommendations. b. The contractor shall provide full maintenance on site, to include all labor, travel expenses, tools, test equipment and other incidentals necessary to maintain Chillers #4, #5 and #6 according to the manufacturer s recommendations; replacement parts are not included for Chillers #4, #5, and #6. Maintenance shall be performed impacting one chiller at a time to allow for continued cooling of the Operating Rooms and Sterile Processing. c. The service shall be provided during regular business hours of 7:30am 4:30pm, Monday through Friday, excluding federal holidays. 2. General Work Items: a. The maintenance service shall include one (1) Preventive Maintenance Inspection (PMI) to be accomplished during the first two weeks of April. The PMI is to be scheduled with Facilities Management Service (FMS) Contracting Officer s Representative (COR) only. All work will be scheduled a minimum of one (1) week in advance with the COR. i. This service is required to maintain operation of the chillers as outlined on the checklist covering motor, compressor, coolers, condensers, purge and recovery units, starters and operating controls. ii. The contractor must have a minimum of three (3) years maintenance experience on centrifugal R123 machines of 1,000 tons or greater. iii. The contractor shall furnish all necessary tools, equipment, and Personal Protective Equipment (PPE) to perform the work safely, effectively, and timely. Tools, equipment, and PPE shall comply with the requirements of OSHA Standard 29 CFR 1910, Subpart 1. iv. The following is required of the Annual Winter PMI on Chillers 1, 2, 3, 7 under this agreement: Check supply voltage to each chiller and lock off power Check low and high voltage connections in starter and at motor Page 1 of 5 Disassemble starter contactors and check condition of contact points Meg test main compressor motor and oil pump motor Replace each chillers oil filter Replace purge filter on each chiller Replace any additional chiller filters Use Vac-U-Save to heat chilled and condenser water and pressurize machine Leak check each chiller identifying any refrigerant leaks Remove original oil charge from each chiller Add new replacement oil charge to each chiller Close chiller and condenser isolation valves and drain water from each barrel Remove 1 evaporator and 1 condenser head and use reamer to brush clean the tubes Install evaporator and condenser heads on each chiller and fill with water Check operation of chilled and condenser flow switches Power up chiller and check operation of oil heater, oil pump and oil regulator Check chiller setpoints and test each chiller safety and operating control Pull oil and refrigerant sample and send to testing lab for analysis Complete operating report on each chiller noting any defects found Report any deficiencies to COR v. The following is required of the Annual Spring PMI on Chillers 1, 2, 3, 7 under this agreement: Check supply voltage to each chiller and oil sump temperature Start each chiller and check for proper y-delta start sequence and timing Check amperage on main chiller motor and oil pump motor Check for proper oil pressure and adjust as needed Check chilled water entering and leaving water temperatures Check condenser water entering and leaving water temperatures Confirm proper evaporator and condenser approach temperatures Check evaporator and condenser pressures Read displayed evaporator and condenser saturation temperatures Check for proper oil level and motor cooling Confirm proper modulation to setpoint and guide vane actuator motor operation Load each chiller to 100% confirming proper operation Complete operating report on each chiller noting any defects found Report any deficiencies to COR vi. The following is required of the annual Spring PMI on Chillers 4, 5, 6 under this agreement: Check each compressor for proper oil levels Confirm there are no bubbles in the refrigerant site glasses Install temperature probes and gauges and check for proper Compressor & economizer superheat Check for proper refrigerant suction and discharge pressures Confirm proper refrigerant subcooling Check for proper voltage supply to compressors and condenser fans Check for proper compressor and condenser fan amp draw Monitor the VSD operation to modulate the compressor to the chilled water setpoint (Chillers 5 & 6) Monitor the compressors to stage on and off to meet the chilled water setpoint (Chiller 4) Confirm evaporator and compressor heater operation Check the operation of the chiller safety and operating controls Visible check the chiller for oil or refrigerant leaks Shutdown the chiller and check all high and low voltage connections Check condition of each contactor and contact points Clean the condenser coils with water Measure the glycol percentage in the chilled water system and the vsd Pull an oil sample from each compressor and send to a testing lab for analysis Complete log on the chiller operations Complete inspection report Report any deficiencies to COR b. The parts needed to complete the annual inspection are to be provided by the contractor at no extra cost for Chillers #1, #2, #3, #4, #5, #6, and #7. c. The contractor will perform a Spring Startup during the first two weeks of May. Spring startup will be a two hour 100% load test and final control adjustments. d. The contract also includes emergency service for repair of the chiller(s). Emergency labor is included in this contract. Parts replaced under emergency service will be paid for by the Government. Contractor shall arrive within one hour of notification. e. Magnesium Bar Replacement During annual winter inspection remove inlet and outlet piping from condenser heads Remove the condenser heads on the inlet and outlet water piping side Install replacement magnesium bars Install condenser heads and piping with new gaskets as required f. Eddy Current Testing (Performed during base year of contract) During the annual inspection period when the condenser and evaporator heads are removed, and the tube brush cleaning has been completed Complete Eddy Current testing of the 4-chiller evaporator and condenser tubes Supply a detailed report listing the condition of all tubes and any defects found Install the condenser and evaporator heads with new gaskets as required g. Vibration Analysis (Performed during base year of contract) Start and control each chiller to load and unload as required Complete chiller vibration analysis Complete detailed report listing bearing condition and machine balance 3. Chiller Information: Chiller Size / Manufacturer Model Serial No. VA No. #1 500 Ton / Trane CVHE500 L97G04950 543EE20979 #2 1000 Ton / Trane CVHF910 L98B01293 543EE20978 #3 1000 Ton / Trane CVHF910 L98B01314 543EE20977 #4 York International YC1V0197EA46VABBXT 2EWM006332 139634 #5 York International YC1V0197EA46VABBXT 2EWM006333 139635 #6 York International YLAA00946XCAS 2EWM006379 139636 #7 1200 Ton / Trane CVHF130 L13E0228 543EE155597 4. Reporting: a. Provide written report of all work performed and any parts replaced. Reports shall be submitted to the COR. Payments may be withheld pending receipt of this report. b. Information shown in the report shall be as follows: i. Company s name, address, telephone & FAX numbers. ii. Name and signature of contractors who perform the inspection and/or repairs. iii. VA Work Contract Number, name, and number of VA Contracting Officer. iv. Date and time of work. v. Type, model, and serial number(s) of all equipment on which maintenance was performed. vi. Total time spent performing maintenance, excluding travel time. vii. Detailed narrative description of the PMI action required. viii. Complete list of parts replaced. ix. Date and time the repair or PMI was completed. x. Recommended corrective actions, if any. c. Contractors shall report deficiencies that are deemed critical or catastrophic immediately to the COR. d. This service report will itemize every item in the specifications. Each item will state the as found condition or values, the calibrated to or adjusted to values, the factory design tolerances, and a complete description of all work performed concerning the items. Included will be a list of new parts used and recommended future repairs. 5. Contract Terms: a. All services for this contract must meet original manufacturer performance and technical specifications, Federal Regulations, and other specifications that may apply such as National Electric Code (NEC), VA Regulations, and the Clean Air Act. b. The contractor shall not replace any parts or perform any service that will result in additional charges without prior approved from the Contracting Officer. c. All contracting personnel must report to the FMS Office to sign in before work is begun and to sign out after work has been completed. The authorization requirements do not apply, a Security Accreditation Package is not required. END

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C25523Q0806
  1. Market Research

Pre-solicitation or formal solicitation typically follows within 30–180 days. (estimate)

  1. Market ResearchCurrentOct 4, 2023

    J045--Annual Chiller Maintenance/Repair

    Notice 676f2cf02d07464395c908d2ab00ac1f on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
This is an INTENT TO SOLE SOURCE NOTICE only. This is an intent to sole source notice for commercial items prepared in accordance with FAR Subpart 5.2, Synopses of Proposed Contract Actions. This announcement constitutes the only notice of intent to sole source and synopsis of proposed action. The Department of Veteran Affairs, Network Contracting Office (NCO) 15, intends to issue a sole-source contract under the authority of this non-competitive acquisition as implemented by 41 U.S.C. 3304(a)(1) - FAR 6.103-1 (only one responsible source and no other supplies or services will satisfy agency requirements), to CareFusion Solutions, LLC, located at 3750 Torrey View Ct, San Diego, California 92130. Services will consist of a three (3) year IDIQ with ordering periods. CareFusion Solutions, LLC for PYXIS Carousel Maintenance Support Services THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES; however, any responsible firm that believes it can meet the requirements may give written notification and capability statements prior to the response due date and time. Vendors shall indicate if they are the direct supplier of the items. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to perform the requirements and must include relevant corporate experience along with the applicable contract number, total contract dollar amount, contract period of performance, details of the relevant services and customer point of contact with corresponding telephone number and email address. Authorized by OEM to repair and maintain Pyxis Carousel. Responses must include following information: Company Name SAM UEI number Company s address Point of Contact information (title, phone number and email address) Business size. Response received will be evaluated; however, a determination by the Government not to compete the proposed procurement based on responses to this notice is solely within the discretion of the Government. This notice of intent is not a request for quotations; interested parties may express their interest by completing the below questions and returning it to lisa.buchanan1@va.gov no later than 10:00 AM CST on 11/23/2026. When responding to this announcement, respondents should refer to number 36C25527Q0054, Notice of Intent in the subject line. The NAICS Code for this acquisition is 811210. Brief Description of Services See attached Draft Performance Work Statement (PWS). Capability Statement All interested contractors must respond by email to lisa.buchanan1@va.gov before 10:00 A.M. CST on 11/23/2026. Please answer the following questions when responding: What is your company s Socioeconomic Status? (ex: small business, large business, SDVOSB, etc.) a. If SDVOSB or VOSB, are you registered with the Small Business Administration? https://search.certifications.sba.gov/?GoTo=multiselect Provide Company s legal name along with Unique Entity ID (SAM) number. Primary point of contact, including phone number and e-mail address. Capabilities Statement. List other Projects (Government and Commercial) that are similar in scope and size. As this is a service acquisition, the Small Business Administration and the Federal Acquisition Regulation have a Limitations on Subcontracting Requirements. For all small businesses, to include SDVOSB and VOSB, At least 50 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern. See FAR 52.219-14 and FAR 52.219-27 available in full text at https://www.acquisition.gov/far-overhaul/far-part-deviation-guide/far-overhaul-part-52 6a. Of the service actions listed above, which one(s) will your company perform as the prime contractor using its own personnel without subcontracting? 6b. With respect to the service actions listed above, which action(s) do you intend on subcontracting or using other than your company s own personnel? 6c. Of those services that will be performed, approximately what percentage will be paid to the subcontractor(s)? Provide authorization letter showing your business is an authorized provider of services and supplies for PYXIS equipment listed in the Draft Statement of Work. GSA Contract Number, if applicable. *Failure to provide the information requested above (items 1-8) will be considered non-responsive and will not be considered a viable source. RFQ number 36C25527Q0054 has been assigned and should be referenced on all correspondence regarding this announcement. The Government will use this information when determining its business type decision. This synopsis is not to be construed as a commitment by the Government and no contract will be awarded as a direct result of this Sources Sought announcement. Notes: Contractors must have a current registration in the System for Award Management (SAM) at https://sam.gov/SAM/ See attached document: PWS Pyxis Support DRAFT.
-Special Notice11/23/2026
This is the Combined Synopsis/Solicitation Notice for the Bayer CT Contrast Injector Maintenance Services at the Marion VAMC and Evansville CBOC. See attached Combined Synopsis-Solicitation 36C25527Q0048 document for ALL details. IMPORTANT: READ THE ENTIRE ATTACHED DOCUMENT TO THIS ANNOUNCEMENT! it is imparative that you follow ALL of the quote submission instructions in order for your quote to be considered responsive.
-Combined Synopsis11/20/2026
Surgical Instrument Maintenance – Columbia VA Medical Center ………. THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A SOURCES SOUGHT NOTICE ONLY. This Sources Sought Notice is intended for information and planning purposes only at this time, and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Additionally, the Government reserves the right to revise the requirements of the proposed action before the release of any associated solicitation. This notice is not a Request for Quotes (RFQ). ………. The Department of Veterans Affairs (VA), VISN 15, Network Contracting Office (NCO) 15, is seeking information and potential qualified sources capable of providing recurring preventive maintenance and repair services for reusable medical devices (RMD), including general stainless-steel surgical instruments, laparoscopic instruments, and sterile container systems for the Harry S. Truman Memorial Veterans’ Hospital (HSTMVH) in Columbia, Missouri. ………. Please review the attached Statement of Work. Feedback and suggestions are welcome. ………. For market research purposes, all responses to this notice will be reviewed, regardless of business size or socioeconomic category. Review of responses to this notice will support later determination of set-aside requirements, if a solicitation becomes available. ………. NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance ………. Product or Service Code (PSC): J065 - Maintenance, Repair, and Rebuilding of Equipment – Medical, Dental, and Veterinary Equipment and Supplies ………. Interested companies can respond via email to matthew.curl@va.gov, with the following information: (1) Company point of contact, including name, title, phone number, and email address. (2) Company name, SAM.gov UEI number, small business/socioeconomic status of the company, and address of the applicable office. (3) Provide marketing literature of the available services that meet the requirements provided in the Statement of Work. Additional information may be requested by the Contracting Officer at a later time.
-Market Research11/16/2026
Amendment 0006 to answer questions and provide update to CLIN and PWS
-Solicitation10/30/2026
SOURCES SOUGHT NOTICE REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT GE Imaging Service and Maintenance THIS IS A REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this RFI/Sources Sought Notice is for market research purposes only, to obtain information in regards to the availability of specified products, services, or a combination of both products and services, and to identify potential sources capable of providing products or performing services in accordance with the requirements below. Responses to this notice will be used by the Government to make appropriate acquisition decisions. DISCLAIMER: This RFI/Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI/Sources Sought Notice that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. If a solicitation is issued it shall be published at a later date and all interested parties must respond to that solicitation announcement separately from the response to this RFI/Sources sought notice. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Submission of price, delivery, capabilities, and other market information are authorized. However, responses to these notices are not offers and cannot be accepted by the Government to form a binding contract IAW FAR 15.201(e). The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 811210 (size standard of $34 Million). DESCRIPTION: The Department of Veteran Affairs, Network Contracting Office 15 (NCO 15) is seeking sources that can provide preventative maintenance and services for GE Imaging Systems in accordance with (IAW) the below requirement and North American Industry Classification System (NAICS) code 811210 with a size standard of $34 Million. The Evansville, IN VA Health Care Center is requesting a preventative maintenance and service contract for GE Imaging systems at it s hospital. General Scope of Work: The contractor shall furnish all support labor, transportation, and parts necessary to provide preventive maintenance, software updates, remote call support, or remote diagnostic service for troubleshooting and repair of the equipment listed in section (III.) of this document in support of the Evansville, IN VA Health Care Center and Mount Vernon, IL VA Clinic. QUALIFICATIONS: Each respondent must have an established business, with an office and full-time staff to include a "fully qualified" Field Service Engineer (FSE) and a "fully qualified" FSE who will serve as a backup. "Fully qualified" is based on Original Equipment Manufacturer (OEM) training and experience in the field. For equipment training, the FSE(s) must show that they have successfully completed a formalized OEM training program on the equipment identified in the heading of this SOW. For field experience, the FSE(s) must demonstrate that they have a minimum of two years experience with respect to scheduled and unscheduled preventive and remedial maintenance of this equipment. The FSE(s) shall be authorized by the contractor to perform the maintenance services. All work shall be performed by fully qualified and competent FSE(s). The contractor shall provide written assurance of the competency of their personnel and a list of credentials for approved FSEs for each make and model that this SOW covers. If subcontractors are used, they must be approved in advance by the CO. The contractor shall be required to provide the same qualifications for all subcontractor FSEs as identified above. SERVICES TO BE PROVIDED: A. Repairs Service Hours: All repairs will be performed during normal VA business hours (8:00 AM 4:30 PM, Monday-Friday), excluding Federal Holidays unless otherwise specified. Contractor may work outside normal business hours by arrangement with the COR if such services are provided without additional charge to the government. Any overtime charges must be approved prior to the initiation of overtime work. Response Time: A technical support representative will respond by telephone to the VA within thirty (30) minutes of the original service call. The contractor will arrive on-site for repair within four (4) hours of the original service call. Radiology equipment shall have a guaranteed uptime of 97% or greater. Ultrasound Equipment shall have an uptime of 95% or greater, ensuring minimal downtime for critical diagnostic operations. Documentation and Resources: The VA shall not provide service manuals or service diagnostic software to the contractor. The contractor shall obtain, have on file, and make available to its FSE(s) all operational and technical documentation (e.g., operational and service manuals, schematics, parts lists) necessary to meet the performance requirements of this contract. The location and listing of the service data manuals, by name, and/or the manuals shall be provided to the CO upon request. Any charges for parts, manuals, tools, or necessary software for maintenance/repairs are included within this contract and its agreed-upon price unless otherwise stated in writing. B. Parts Replacement Parts: The contractor shall provide all necessary replacement parts to ensure the equipment performs within the manufacturer's specifications. This includes, but is not limited to, coverage for tubes, ultrasound probes, detectors, grids, tables, and batteries. All replacement parts must meet or exceed the factory specifications to maintain compatibility with existing systems and support future performance and reliability upgrades. Any parts removed and replaced by the contractor will become the property of the contractor. Replaced parts must be delivered on-site no later than 10:30 AM the following day. C. Software Updates/Upgrades Software Maintenance: The contractor will furnish, free of charge, all OEM software or hardware upgrades to the equipment purchased by the VA, which are intended to correct safety risks. Software updates offering enhancements to previously purchased software features shall also be covered under this service agreement if they do not require hardware modifications or additions. D. Scheduled Maintenance Preventive Maintenance (PM): The contract will include comprehensive scheduled preventive maintenance inspections (PM) as required by manufacturer specifications. Scheduling: A mutually agreeable time for the inspections will be scheduled through the COR, Healthcare Technology Management (HTM) staff, or the Radiology supervisor/CT Lead. Inspection and Maintenance Procedures: The contractor will perform PM Services to ensure that equipment listed above functions in conformance with the latest published editions of NFPA-99, OSHA, and CDRH standards. The contractor shall provide and utilize procedures and checklists with worksheet originals indicating work performed and actual values obtained (as applicable) provided to the COR or HTM staff upon completion of the PM. Preventive maintenance procedures will be submitted to the COR for approval prior to initiation of this service and kept on file. PM services shall include, but are not limited to: Cleaning of equipment Reviewing operating system diagnostics to ensure system operation meets manufacturer's specifications Calibrating and lubricating the equipment Performing non-emergent remedial maintenance Testing and replacing faulty or worn parts and/or parts likely to become faulty, fail, or become worn Inspecting and replacing necessary cables and bushings Measuring, adjusting, and calibrating for optimal image quality Inspecting all mechanical components including, but not limited to, probes, cables, mounting hardware, chains, belts, bearings, tracks, interlocks, clutches, motors, monitors, keyboards for mechanical integrity, safety, performance Returning equipment to full and proper operating condition per manufacturer specifications Conducting an electrical safety inspection (as applicable) and documenting the results. Compliance: The contractor, their personnel, and their subcontractors shall be subject to Federal laws, regulations, standards, and VA Directives and Handbooks regarding information and information system security as delineated in this contract. E. Documentation Service Reports: At the conclusion of each repair or scheduled maintenance visit, the contractor will provide a service report indicating the date of service, model, serial number, and location of the equipment serviced, the name of the service representative, hours worked, services performed, and parts replaced. Submission of Reports: Service reports will be provided to Healthcare Technology Management (HTM) staff by hand delivery when work is complete or via email within 48 hours after completion. EQUIPMENT: System ID: GEHC XR AMX NAVIGATE COLLAPSIBLE 0D/1D/2D (XMB230) System ID: GEHC XR Definium 656 HD (XRA732) System ID: GEHC XR FlashPad - Digital Wireless Detector (Legacy) (XRA614) System ID: GEHC XR FlashPad HD Detector 14 x 17 (XRA618) System ID: GE UL VIVID E95 R6 (UVI95L) System ID: GEHC XR FlashPad HD Detector 14 x 17 (XRA618) System ID: GE XR DISCOVERY XR656 2-D G2 (XRA622) System ID: GE XR FlashPad - Digital Wireless Detector (Legacy) (XRA614) System ID: GE XR FlashPad - Digital Wireless Detector (Legacy) (XRA614) System ID: GE XR OEC ELITE 31cm CFD VASMTS (XMS731) Serial: FBXXTE00444 System ID: GE XR DISCOVERY XR656 2-D G2 (XRA622) System ID: GEHC XR FlashPad - Digital Wireless Detector (Legacy) (XRA614) System ID: GEHC XR FlashPad - Digital Wireless Detector (Legacy) (XRA614) VENDOR RESPONSE If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. 1. Company Name: 2. Company Address: 3. SAMS UEI: 4. Company POC: 5. Phone Number: 6. EMAIL: 7. Is your company considered a small business IAW the NAICS identified in this RFI/Sources Sought Notice? If so, please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? 8. If your company is considered a large business, does your company have any authorized small business distributors/suppliers, service providers, and/or does your company sub-contract to small business concerns? a. If so, please provide the company name, company POC, and small business status (if available): 9. Is your company an authorized service provider (or equivalent) of the services identified in this sources sought? If so provide authorization letters and/or agreements from manufacturer. 10. Does your company currently hold a Federal Supply Schedule (FSS) contract with GSA, the VA National Acquisition Center (NAC), NASA SEWP, VA Strategic Acquisition Center (SAC), or have any other federal contract that can be utilized to procure the services identified in this sources sought? 11. Please submit a capabilities statement that provides clear, compelling, and convincing evidence that your company can meet the requirements outlined in this sources sought. 12. COMMENTS: Please provide recommendations that may be pertinent to the improvement of the Statement of Requirements and potential solicitation. Responses to this notice shall be submitted via email to Tracie Raggs at tracie.raggs@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Monday, November 02, 2026, at 0800 CST.
-Market Research11/02/2026

Additional Details

Solicitation Number

36C25523Q0806

Archive Date

Dec 17, 2023

Office Address

LEAVENWORTH, KS, 66048