Notice ID: a0173bdee6594c07ba8957d53fc64f71Award NoticeAwardedArchived
6640--36C25526A0008 | Chemiluminescence Analyzer | Columbia and Kansas City | 01/05/2026 - 01/04/2031
Awarded on December 29, 2025. Full description on SAM.gov.
Awarded tounder 36C25526A0008 (source: SAM.gov award notice)• $0
Overview
- Posted
- January 12, 2026
- Notice type
- Award Notice
- NAICS
- 334516: Analytical Laboratory Instrument Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 255-NETWORK CONTRACT OFFICE 15 (36C255)
- Place of performance
- VISN 15 LOCATED AT: COLUMBIA VAMC, 800 HOSPITAL DRIVE, COLUMBIA MO 652 KANSAS CITY VAMC, 4801 EAST LINWOOD BLVD, KANSAS CITY, MO 64128
- Last updated
- Nov 4, 2026
- First published
- Last updated on SAM.gov
- Award date
- Dec 29, 2025
- Award amount (SAM.gov award notice)
- $0
Identifiers
- Solicitation number
- 36C25525Q0219
- Notice ID
- a0173bdee6594c07ba8957d53fc64f71
- Award number (PIID)
- 36C25526A0008
Description
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT DISCLAIMER This sources sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this sources sought that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this sources sought In Accordance With (IAW) FAR Part 15.201(e). SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is an RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334516, Analytical Laboratory Instrument Manufacturing; Size Standard: 1,000 employees. Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The following VAAR policies and clauses will be applicable to this requirement if an SDVOSB/VOSB entity is interested and qualified in this requirement: limitations on subcontracting requirements set forth in 15 U.S.C. § 657s and in VAAR 852.219-10 and 852.219-11. 852.219-77, VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction Contractor Staff, Roles, and Responsibilities Must be in compliance with all NRC, USP, state, local and TJC guidelines. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the brand name. If you are interested and are capable of providing the sought supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? Is your company considered small under the NAICS code identified under this RFI? Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? Does your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above? If so, please provide the contract number. Please submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described in the attached SOW. Please provide your Contractor s Unique Entity ID (SAM): Responses to this notice shall be submitted via email to Jeanine Wallace at Jeanine.wallace@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Tuesday, April 1, 2025, at 1300 CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following: See Statement of Requirement below
Award Overview
Award Number
36C25526A0008
Award Amount (SAM.gov award notice)
$0
Award Date
Dec 29, 2025
Awardee
Awardee UEI
FGK2QR959BV5
Awardee CAGE Code
1KF01
Awardee Address
STILLWATER, MN 55082, MN
Original Solicitation
Notice ID: a0173bdee6594c07ba8957d53fc64f71
Posted Date: Jan 12, 2026
Original Response Deadline: Not specified
Task Orders Under This IDV
Top 10 by total obligated
- $153.3KSigned Jan 9, 2026
More From This Vendor
Top 5 most recent
- $40.8KSigned Oct 22, 2026
- $215.7KSigned Oct 1, 2026
- $42.4KSigned Oct 1, 2026
- $94.9KSigned Oct 1, 2026
- —Signed Oct 1, 2026
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C25526A0008_2.docx
13 KBAdded in Award Notice version 3Posted
Lifecycle
- 3Version 3Award NoticeArchivedCurrent
6640--36C25526A0008 | Chemiluminescence Analyzer | Columbia and Kansas City | 01/05/2026 - 01/04/2031
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Sources Sought Notice Sources Sought Notice Page 5 of 5 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 5 This is NOT a solicitation or request for quote. This is NOT a request for proposal. This is NOT a job advertisement for hiring employees. The VA is seeking QUALIFIED VENDORS to provide a very brief response to this notice including only just what is asked for in this notice below. This is sources sought notice to industry and the only information is posted on Contract Opportunities web page at SAM.gov. Sources sought means seeking qualified vendors. The attachments included on the Contract Opportunities page do not include any additional information. If your company is interested, please read this notice entirely and submit the required information, as requested herein. Automated Blood Culture Analyzers and Bottles Four (4) VA Medical Centers: Fort Harrison, MT, Cheyenne, WY, Grand Junction, CO and Sheridan, CO BRIEF SCOPE OF WORK (This is for information only) IMPORTANT NOTE: This Sources Sought is for market research purposes only (to determine the socioeconomic status of interested companies). No award will be made off this posting. The four (4) VA medical centers each require an automated blood culture analyzer with corresponding blood culture bottles. It is anticipated the blood analyzer would be provided to each facility for use for a base period (1 year) with four (4) additional optional years. **The current blood culture analyzer in use at each facility is the BD (Becton Dickinson) BACTEC FX40 Automated Blood Culture System** Overview of Items (5-years): Line Item # Description Unit Base Yr Qty OY#1 Qty OY#2 Qty OY#3 Qty OY#4 Qty Fort Harrison, MT 0001 Blood Culture Analyzer EA 1 1 1 1 1 0002 Blood Culture Management Computer and Software EA 1 1 1 1 1 0003 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 26 26 26 26 26 0004 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 26 26 26 26 26 0005 BOTTLE PLASTIC Myco F Lytic 50/PK PKG 3 3 3 3 3 0006 Connectivity & Workflow Management EA 1 1 1 1 1 Cheyenne, WY 0007 Blood Culture Analyzer EA 1 1 1 1 1 0008 Blood Culture Management Computer and Software EA 1 1 1 1 1 0009 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 28 28 28 28 28 0010 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 28 28 28 28 28 0011 BOTTLE PLASTIC PEDS PLUS/F 50/PK PKG 4 4 4 4 4 0012 Connectivity & Workflow Management EA 1 1 1 1 1 Grand Junction, CO 0013 Blood Culture Analyzer EA 1 1 1 1 1 0014 Blood Culture Management Computer and Software EA 1 1 1 1 1 0015 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 20 21 22 23 24 0016 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 20 21 22 23 24 0017 BOTTLE PLASTIC PEDS PLUS/F 50/PK PKG 1 1 1 1 1 0018 Connectivity & Workflow Management EA 1 1 1 1 1 Sheridan, CO 0019 Blood Culture Analyzer EA 1 1 1 1 1 0020 Blood Culture Management Computer and Software EA 1 1 1 1 1 0021 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 12 12 12 12 12 0022 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 12 12 12 12 12 0023 Connectivity & Workflow Management EA 1 1 1 1 1 0024 Remote Alert System (After Hours) EA 1 1 1 1 1 Statement of Work: 1.0 Scope of Work The microbiology department of the Pathology and Laboratory Medicine Service (P&LMS) requires a cost per bottle contract to provide new automated Blood Culture instruments for use at the Ft. Harrison campus of the VA MT Healthcare System, Cheyenne VAMC, Sheridan VAHCS, and Grand Junction VAMC. Equipment and supplies must be installed, fully approved by the station team, and ready for use no later than May 1st, 2027. The awarded contract will have a one-year base period with four annual option periods. 2.0 Tasks The vendor shall provide all automated blood culture instruments, supervision, parts, labor, software, preventative maintenance, materials, and incidentals in order to ensure fully successful blood culture test and meet or exceed all listed requirements in the specifications below. 2.1 General Requirements Requirements, as set forth in this statement of work are minimum standards and shall not be construed as limiting the overall quality, quantity, or performance of the instrument. The vendor shall maintain the performance and overall quality of all instrument systems during the period of performance to all software upgrades, equipment, maintenance, parts, and labor to ensure full functionality and currency of new automated blood culture instruments. The instrument system, based upon the specifications requested, shall be the newest and the most current model. Refurbished systems are not acceptable. The instrument must be a standard product of the manufacturer of record. The manufacturer of record is defined as a company whose main occupation is the manufacture for sale items of equipment and which: Maintains a factory production line. Maintains a stock of replacement parts for the item. Maintains engineering drawings, specifications, operating manuals and maintenance manuals. Has published and distributed descriptive literature and equipment specifications on the equipment. The analyzer cabinet/instrument shall be a countertop model fitting within the following available spaces: Montana 75 in W x 45 in D Cheyenne 45 in W x 30 in D Grand Junction 87 in W x 30 in D Sheridan 31 in W x 36 in D If the proposed analyzer does not fit the dimensions of any of the stations above, a contractor provided cart may be used if the station agrees and has the room for it. All equipment/supplies/bottles and software must be FDA-approved at time of award 2.2 System Requirements The instrument system shall meet the following requirements: Use plastic and glass culture bottles that are specific to the instrument system and the culture bottles used in the instrument should contain a neutralizing resin media for the aerobic culture bottle and a lytic broth media for the anaerobic culture bottle. + Be able to accept and analyze blood, fungal and an acid, fast, bacteria (AFB) culture bottles. Be able to accept and analyze both blood and body fluid specimens. Utilize a varied selection of blood culture bottle configurations (low volume samples; antimicrobial agent removal resins) and formulations capable of maximizing growth potential of various microorganisms (e.g. aerobic and anaerobic bacteria, fungi, and mycobacteria) shall be available. Have the capability to flag and alert the end-user of positive culture vials by simultaneous visual alert, sound alert and remote alert using existing software programs. The Sheridan VAMC lab does not run 24/7 so the contractor shall provide a system by which their AODs (Administrative Officer of the Day) can monitor the system remotely 24 hours per day. Provide self-contained, continuous, computerized, automated monitoring of blood culture bottles with immediate, active (e.g. audible alarm) notification of microorganism growth based upon pre-programmed criteria and notification of termination of maximum programmed incubation period when no microorganism growth is detected. Allow for operator extension of programmed incubation times while testing is in progress, without interruption of automatic continuous monitoring. Have the capability to monitor the blood volume in each culture bottle. Utilize sufficient safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. Have the capability to detect and document elapsed time to positivity. Have bar code reading capability to eliminate the need for manual entry of patient information for each sample. Contractor bar code formats shall meet requirements of VA lab information system software. Have the capability to scan the culture vial sequence and specimen accession label in any order. Have the capability to accept the culture vial in any available station. Have the ability to provide automated transmission of test results into the laboratory s current laboratory information system LIS. Contractor must be able to send information through Data Innovations (DI) instrument server and have DI driver available. Must provide all hardware and software needed to connect via TCP\IP protocol, as well as communicate with government VISTA protocols and system. Utilize Food and Drug Administration (FDA)-cleared software. Contain a report module that has the ability to generate epidemiology and statistical reports. Contain a data management system that allows users to monitor and analyze data. Provide printed paper results in the event of computer down time. Have the ability to electronically archive patient results. Have the ability to generate cumulative quality control (CQC) reports. 2.3 Instrument Requirements When requested, the instrument cabinet should be able to hold a minimum of 200 culture bottles Some facilities may have smaller minimum volume requirements. The vendor should have a variety of instrument sizes and types to accommodate the estimated annual volume requirement for each facility. The instrument should take up minimal space and have the ability to stack incubation cabinets on top of each other. The instrument should require only minimal maintenance by government personnel. The instrument must include an on-board programming display and be user friendly. The instrument system must include a 120-volt Uninterrupted Power Source (UPS) system that has a 30-minute backup capability in the event of electrical power interruptions. The system should also have provisions for saving data in the event that the capacity of the UPS is exceeded. The vendor shall provide all software upgrades and a field technical representative from the instrument manufacturer shall install the updated software at no charge within a reasonable time and shall coordinate with the laboratory supervisor. The instrument system shall have the ability to accept upgrades so as to accommodate the need for increased testing volume. Software must be compatible with Bruker MALDI bio-typer 2.4 Supply Requirements The vendor shall: Supply a variety of plastic and glass culture bottle types and allows flexibility in the selection of culture bottle types required based on facility needs. Shall provide customer helpline telephone numbers for VAMC laboratory technicians to the call-in routine and emergency supply request. The vendor shall supply all necessary point of contact information and ordering procedures for VAMC laboratory technicians to order reagents and other supplies for both a standing delivery schedule basis or on an as-needed basis. Fill routine and emergency supply requests when requested. Pay shipping fees for all supplies, consumables, and equipment needed to perform installation start-up testing. Provide ancillary components that are necessary for the model of equipment proposed (i.e. starter kits, tables, stands, etc.). List all reagents, controls and disposables required for operating the instrument and producing quality results as an addendum in the pricing schedule. 2.5 Repair & Maintenance Services The manufacturer shall provide technical support either by phone or on-site. Service should include all travel, parts for repair or replacement, and labor. The vendor shall provide a preventative maintenance schedule to include a minimum of one scheduled preventative maintenance visit per year. The vendor shall be responsible for the removal of the hard drive of the analyzer upon removal/upgrade of the instrument. The hard drive shall be given to the laboratory VA information system manager for disposal. The service shall include replacement or repair of all ancillary equipment (i.e. printers, monitors, UPS) necessary for the system to operate efficiently. 2.6 Pre-Installation Assessment The vendor shall provide written information detailing all maintenance, environmental, and utility requirements (electrical, dimensions of equipment, media disposal, etc.) as part of their proposal to include the following information. If the equipment proposed is particularly heavy, advisement of extra reinforcement shall be necessary. Provide dimensions of the system. List utility requirements (electrical, heat/cool, humidity, etc.) Describe testing methodology. List quality control (QC) frequency. Describe maintenance requirements for daily/weekly/monthly maintenance. Describe any environmental impact issues that instrumentation may create (water requirements, media disposal, etc.). Describe user friendliness: Describe software and/or supporting instrumentation provided with the system to maintain or improve levels of data retrieval which may be used for monitoring epidemiology trends. Describe reagent management (storage and waste). Describe ability to trouble-shoot system. Describe how system alerts user of positive and negative culture bottles. Provide list of reagent recalls/bulletins within the last two years. List reagent unavailability due to manufacturing issues within the last two years. Environmental requirements (heat/cool, humidity, light, etc.) and recommendations for instrument and testing material storage. Manufacture s maintenance requirements indicating what maintenance is performed by the end-user and what maintenance is performed by the manufacturer by providing outline or brochure outlining frequency of preventative maintenance. 2.8 Laboratory Information System (LIS)/Interface Software must be compatible with all barcode styles and have proven bi-directional interface capability with the laboratory s current LIS. The vendor must provide additional hardware (i.e. middleware) and software needed to interface the system and provide technical assistance with interfacing the instrument system. Required (additional) interface connection license(s) shall be provided at vendor cost. The instrument-LIS interface must be bi-directional. The interface must use automatic host query to download sample, IDs, test requests, and patient demographics. Automatic host query must seamlessly integrate with on-board patient sample barcode scanning and translation. The instrument interface must transmit test results to the host computer system via automatic upload. Instrument system must have computer capabilities that are compatible with the end-user s LIS software and include an LCD display monitor and printer. The vendor shall provide technical support to link the instrument to the LIS interface and ensure that the instrument system is communicating properly. Vendor must successfully interface the analyzer via a Data Innovations Instrument Manager to the VA VISTA system. Must be compatible Bruker MALDI bio-typer 2.9 Support Services: The manufacture should have the ability to provide service sufficient to meet the needs of the end-user facility, 7 days a week, business hours for all sites. A field engineer must be available within 24 hours of after the service call has been placed. All repairs to the instrument must be complete within 24 hours from the time the field service engineer arrives. The vendor s staff shall designate in writing to the contracting officer a fully qualified primary and alternate Field Service Representative who has the authority and knowledge to respond to all technical/maintenance/repair issues. Fully qualified is based upon training and experience in the field. For training, the Field Service Representative must have successfully completed a formalized training program for the equipment covered under the contract. For field experience, the Field Service Engineers must have a minimum of one (1) year of experience providing preventative maintenance and emergency repair services on the same make and model of equipment covered under this contract. The vendor shall provide 24-hour, 7 days/week telephone technical support. The vendor shall submit a legible field service report to the laboratory supervisor itemizing the preventive maintenance inspection or emergency repair services performed, including replaced parts and estimated prices required for the service call. The vendor shall coordinate on all potentially hazardous safety issues with the contracting officer and laboratory supervisor. 3.0 Installation, including Instrument Validation & Training A technical support specialist from the instrument manufacturer shall assist in equipment installation/set-up, providing all manpower, procedures, and reagents/supplies to perform validation and correlation studies [evaluation/comparison data sufficient to satisfy College of American Pathologists (CAP) standards]. The vendor must provide required statistical analysis of the validation and correlation data in an organized binder for on-site director approval. The statistical analysis must be completed within eight weeks of installation of the system. The vendor/distributor and/or the manufacturer must provide all necessary procedure manuals, troubleshooting manuals and operator manuals. The vendor shall provide primary user training for a minimum of one user per instrument with on-site basic operating and maintenance education/training performed during initial installation and when updates to the equipment are performed. Training is to include all costs related to off-site training (transportation, room and board, etc. if applicable). Any additional costs such as industrial funding fees, special shipping and handling fees, or other usage fees must be included in the contract price or identified separately in the proposal. 4.0 Delivery and Acceptance 1. All items shall be shipped F.O.B. destination to the following locations M-F, 8am-4pm, excluding holidays: FT Harrison VAMC 3717 Veterans Drive Ft. Harrison MT 59636, Cheyenne VAMC 2360 East Pershing Blvd Cheyenne WY 82001 Sheridan VAMC 1898 Fort Road Sheridan WY 82801 Grand Junction VAMC 2121 North Avenue Grand Junction CO 81501 The Contractor, its employees, agents, and subcontractors shall not be considered VA employees for any purpose of fulfilling the PWS and shall be considered employees of the Contractor. Contractor shall furnish all labor, materials, equipment, tools, shipping, transportation, insurances, licenses, certifications, and supervision necessary to provide services in accordance with this Performance Work Statement (PWS). The Contractor is responsible for all charges and fees related to disposal of materials generated by the Contractor. This is anticipated to be a commercial supply acquisition under the authority of FAR Part 12, Simplified Acquisition Procedures for Commercial Items. The products will be delivered to the following locations: FT Harrison VAMC 3717 Veterans Drive Ft. Harrison MT 59636, Cheyenne VAMC 2360 East Pershing Blvd Cheyenne WY 82001 Sheridan VAHCS 1898 Fort Road Sheridan WY 82801 Grand Junction VAMC 2121 North Avenue Grand Junction CO 81501 IMPORTANT NOTE: This RFI (Request for Information) is for information only. No award will be made from this RFI. QUALIFIED VENDOR: A qualified source has the a) necessary equipment, vehicles, personnel, resources and current operations as well as b) recent experience (within past 3 years) of performing services of a comparable size, scope and complexity, AND c) OEM certified technicians to perform services with unrestricted access to the facility during inclement weather, as well as immediate access to OEM software updates. A qualified source also has current and valid registration in System for Award Management (SAM), https://www.sam.gov). Please communicate via e-mail to Stephanie.Cahill@VA.Gov by 15:00 MST on November 20th, 2026, as to your company s ability to perform service per this brief Scope of Work. If interested, please provide the following: Provide company s capability statement describing ability to provide equipment that meets or conforms to the salient characteristics listed above *include specification or brochure documents for confirmation of equivalent products* Company s business size in relation to NAICS 334516 and socio-economic category (SDVOSB/VOSB/WOSB/Large Business): SAM UEI: FSS/GSA contract # (if applicable): **Indicate Open Market if items are not included on FSS/GSA/etc.** Estimated delivery lead time: Where are the products manufactured/COO: Only written responses, to items 1 through 6 above, will be accepted at this stage. Information is being gathered for market research purposes only. Industry exchanges and vendor teleconferences are at the discretion of the Contract Specialist. This is not a request for quotes. DISCLAIMER: This is a Request for Information (RFI) from industry in accordance with Federal Acquisition Regulation (FAR) 15.201(e) and on the requirement, that exists for the VA Medical Center(s) identified in this RFI. This is not a request for quote and not a contract. This announcement is not a request for proposals; therefore, responses to the RFI are not considered offers and cannot be accepted by the Government to form a binding contract. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responders are solely responsible for all expenses associated with responding to this RFI. No classified information should be included in the RFI response. Should you have concerns regarding this RFI you may request to contact the Contracting Office that will be assigned this requirement by emailing the sender of this RFI. Questions must be addressed in writing to the Contract Specialist. Requests for VA-business sensitive information, to include VA budget information, VA acquisition planning information, acquisition methods, strategies and set-asides must be addressed via the VA FOIA process: https://www.va.gov/foia/ Thank you for your interest in doing business with the VA. To learn more about the VA Mission, Vision, Core Values & Goals visit https://www.va.gov/about_va/mission.asp To understand the latest updates on the Veterans First Contracting Program visit https://www.va.gov/osdbu/verification/veterans_first_contracting_program_adjustments_to_reflect_the_supreme_court_kingdomware_decision.asp To find out how to do business with the VA visit https://www.va.gov/osdbu/library/dbwva.asp | 72% | Market Research | 11/20/2026 |
Please see attachments. This is a Full & Open Competiton requirement. The Contractor shall provide all the tools, parts, materials, labor, travel, installation, and training necessary to provide one halon analyzer consisting of one fully automated custom gas chromatograph system to the 802d Maintenance Group Chemical Analysis Flight (802 MXSS/MXDTA) at Robins Air Force Base (AFB), Georgia. | 70% | Solicitation | 11/12/2026 |
The U.S. Army Corps of Engineers (USACE) requires a new handheld energy dispersive X-ray fluorescence (XRF) analyzer. The primary purpose of this instrument is to conduct immediate, on-site screening for lead (Pb) content in various materials, such as painted steel structures and coatings. This capability is essential for performing industrial hygiene assessments and environmental compliance inspections in accordance with federal and state lead screening requirements. | 70% | Solicitation | 09/07/2026 |
Notice from the United States Air Force, Air Force Life Cycle Management Center (AFLCMC), Installation Contracting Division, Base Support Contracting Branch at Wright-Patterson Air Force Base (WPAFB), Ohio: The AFLCMC Operational Contracting Branch, Wright-Patterson AFB, Ohio is seeking capabilities packages of potential sources including Small Businesses (SB). This sources sought synopsis is published for market research purposes only, to identify potential sources capable of delivering a Nano-Aerosol Analyzer with the capabilities described herein for the Air Force Institute of Technology, located at Wright Patterson Air Force Base, Ohio (WPAFB). The Government is seeking capabilities packages from all potential sources, including but not limited to: small business (SB), 8(a) participants, HUBZone Small Business, Economically Disadvantaged Women-Owned Small Business (EDWOSB), Women-Owned Small Business (WOSB), Small Disadvantaged Business (SDB) and Service-Disabled Veteran-Owned Small Business (SDVOSB). Firms that respond shall review the attached instructions and technical requirements and submit responses that: Specify that offered products meet the specifications provided below; and Provide detailed information to show clear technical compliance. THIS SOURCES SOUGHT IS FOR MARKET RESEARCH PURPOSES ONLY. THIS IS NOT A REQUEST FOR PROPOSALS/QUOTES. All interested firms shall submit a response to the Primary Points of Contact, Ms. Claire Hess at claire.hess@us.af.mil and Ms. Jessica Stamper at jessica.stamper.2@us.af.mil, demonstrating their capability to provide a Nano-Aerosol Analyzer. Responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. A solicitation for this requirement does not exist, therefore, do not request a copy of the solicitation. The decision to solicit for a contract will be solely within the Government's discretion. The North American Industry Classification System (NAICS) code assigned to this acquisition is 334516 (Analytical Laboratory Instrument Manufacturing) with a small business-size standard of 1,000 employees. Firms responding should indicate socio-economic status (8(a) with Graduation Date, SDVOSB, EDWOSB, WOSB, small business, and/or HUBZone). All respondents may identify potential small-business sources for components, accessories, installation, training, maintenance, or other support associated with the requirement. The Government reserves the right to consider a small business set-aside based upon responses hereto for any subsequent action. All prospective contractors must be registered in the System for Award Management (SAM) database to be awarded a Department of Defense (DoD) contract. A small business set-aside decision has not yet been made. Identify whether your firm is the manufacturer of the proposed end item or an authorized distributor/reseller. If not the manufacturer, identify the proposed manufacturer, its business size, and the country of origin of the proposed end item.” Any information submitted by respondents to this Sources Sought is voluntary. This Sources Sought notice is not to be construed as a commitment by the Government, nor will the Government reimburse any costs associated with the submission of information in response to this notice. Respondents will not be individually notified of the results of any Government assessments. The Government's assessment of the capability statements received will factor into whether any forthcoming solicitation will be conducted as a full and open competition or as a set-aside for small business or any particular small business program. CAPABILITIES PACKAGE: All interested firms shall submit a capabilities package to provide the Nano-Aerosol Analyzer that explicitly demonstrates their capability to provide the required product. The capabilities package should be brief and concise yet clearly demonstrate an ability to meet the stated requirements. However, the response must not exceed five (5) pages. Capabilities Packages submitted in response to this sources sought synopsis must be received at the following e-mail addresses NO LATER THAN 17 NOVEMBER 2026 AT 3:00 PM EASTERN TIME. All correspondence sent via email shall contain a subject line that reads: Nano-Aerosol Analyzer. If this subject line is not included, the email may not get through email filters at WPAFB. Filters are designed to delete emails without a subject or with a suspicious subject or attachments. Attachments with files ending in .zip or .exe are not allowable and will be deleted. Ensure only .pdf, .doc, .docx, .xlsx or .xls documents are attached to your email. All other attachments may be deleted. Responses shall be submitted via email to the following addresses: claire.hess@us.af.mil and jessica.stamper.2@us.af.mil Please direct all questions concerning this acquisition to Ms. Claire Hess at claire.hess@us.af.mil and include the necessary subject line indicated above. Attachments: Instructions Statement of Work | 69% | Market Research | 11/17/2026 |
THIS IS A SOURCES SOUGHT NOTICE ONLY The purpose of this Sources Sought is to conduct market research to procure Brand Name (GenDx) or Equal next generation sequencing (NGS) reagent kits compatible with the Illumina MiSeq instrument. This notice serves to survey the market to ascertain whether-or-not sources are capable of providing the requested supply/services. You also must be an Authorized Distributor for GENDX Products LLC OR an Authorized Distributor for the manufacture of an equal product if not the manufacture. This notice also allows potential contractors/vendors to submit a non-binding statement of interest and documentation demonstrating their capability. Please review the DRAFT Statement of Work (SOW) to compare your supply/service to what is requested. Complete the line-items below and submit any documentation supporting your product/service for consideration. Network Contracting Office 23 (NCO 23) is requesting responses from qualified business concerns; the qualifying NAICS code for this effort is 334516 Analytical Laboratory Instrument Manufacturing. The Small Business Administration (SBA) Size Standard for this request is $19.5M. This Sources Sought is to gain knowledge of potential qualified sources and their size classification(s) (Service Disabled/Veteran Owned Small Business (SD/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, or large business) relative to NAICS 334516. Responses to this notice, will be used by the Government to make appropriate acquisition decisions. After review of the responses to this notice, a solicitation announcement may be published. Responses to this notice are not considered adequate responses to any corresponding solicitation announcement. All interested offerors are requested to respond to this notice but are required to respond to the official solicitation announcement in order to be awarded the contract. INSTRUCTIONS: RESPONSES MUST INCLUDE THE FOLLOWING INFORMATION: Primary Information: Company Name: Point of Contact (POC) name: Email address: Phone number: Unique Entity ID No. listed in the System of Awards Management (SAM): Business Size: (Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Small Business Other, Small Business, or Large Business) for the NAICS code 334516. Identify if Reagent Kits foreign or Domestic to include place of production. Please indicate whether you hold a GSA Federal-Supply-Schedule or Indefinite Delivery/Indefinitely Quantity (IDIQ) contract that covers this type of request. If so, please provide the Schedule contract number. Must have an Authorized Distributor Letter issued from the manufacture if not the manufacture. The attached SOW is a draft and is NOT finalized. If any portions are unclear, prohibited, and/or you are unsure about the draft description of the requirement please list your comments and/or concerns in your response so they can be addressed. Response is due by 11/22/2026, at 1300 Central Standard Time. Please submit e-mail responses to Mr. Emanuel Nevarez, Contract Specialist, at email address: Emanuel.nevarez@va.gov. Please place Next Generation Sequencing (NGS) Reagent Kits in the subject line of your email. This notice is to assist the Department of Veterans Affairs in determining qualified sources only. NOTES: Issuance of this notice does not constitute any obligation whatsoever on the part of the Government to procure these supplies and/or services, or to issue a solicitation, nor to notify respondents of the results of this notice. No solicitation documents exists at this time; however, in the event the acquisition strategy demonstrates that GSA is a viable option for procuring a solution, the RFQ shall be posted to GSA eBuy where only those firms who currently hold a GSA Schedule with the applicable SIN will be able to respond. The Department of Veterans Affairs is neither seeking quotes nor accepting unsolicited quotes, and responses to this notice cannot be accepted as offers. Any information the vendor considers proprietary should be clearly marked as such. The U.S. Government will not pay for any information or administrative costs incurred in response to this Sources Sought notice. | 68% | Market Research | 11/22/2026 |
Additional Details
Solicitation Number
36C25525Q0219
Archive Date
Feb 11, 2026
Office Address
LEAVENWORTH, KS, 66048