GovChime
Notice ID: 2bc171622b914ee08c5ad11acba6170cSources SoughtArchived

6640--VISN 15 Automated Erythrocyte Sedimentation Rate Analyzers - 36C255-26-AP-0538

Archived on December 20, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
7:00 AM CST
Posted
November 21, 2025
Notice type
Sources Sought
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
255-NETWORK CONTRACT OFFICE 15 (36C255)
Place of performance
Department of Veterans Affairs VISN 15 Multiple Sites
Last updated
Nov 5, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25526Q0092
Notice ID
2bc171622b914ee08c5ad11acba6170c

Description

This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products and/or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this Sources Sought Notice in accordance with (IAW) FAR Part 15.201(e). The purpose of this Sources Sought Notice announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service- Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the products and/or services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) Company Name; (b) Address; (c) Point of Contact; (d) Phone, Fax, and Email; (e) UEI Number; (f) Cage Code; (g) Tax ID Number; (h) Type of Small Business, e.g., Services Disabled Veteran Owned Small Business, Veteran Owned Small business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, or Small Business HUBZone business, etc.; (i) State if your business has an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed below and provide the contract number; and (j) Must provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. Requirement: The VA Heartland Network 15 Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide a Cost-Per-Test (CPT) Blanket Purchase Agreement (BPA) for Automated Erythrocyte Sedimentation Rate (ESR) Instrumentation. It is the intent of the Government to award a contract to a single contractor for Automated Coagulation Instrumentation for VISN 15 Heartland Network to include Kansas City VA Medical Center, Harry S. Truman Memorial Veterans' Hospital, Colmery-O'Neil VA Medical Center, Dwight D. Eisenhower VA Medical Center, Center, located in Kansas City, Missouri, and the John J. Cochran Veterans Hospital, Robert J. Dole VA Medical Center, St. Louis VA Medical Center Jefferson Barracks, St. Louis VA Medical Center John Cochran Division, Marion VA Medical Center, Evansville Health Care Center, John J. Pershing VA Medical Center and VA Cape Girardeau Health Care Center. This is a brand name or equal requirement. Please see the Statement of Work for more specifics and details. The North American Industry Classification System Code (NAICS Code) is 334516. (Analytical Laboratory Instrument Manufacturing), size standard 1,000 Employees. Based on this information, please indicate whether your company would be a Large or Small Business and have a socio-economic designation as a Small Business, VOSB or SDVOSB. Important Information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service- Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set- aside or full and open may be used. Responses to this notice shall be submitted via email to Erika Kobulnicky at Erika.Kobulnicky@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, December 5, 2025, at 7:00AM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. STATEMENT OF REQUIREMENT VISN 15- HEARTLAND NETWORK Automated Erythrocyte Sedimentation Device SCOPE OF PROCUREMENT: It is the intent of VISN 15 Pathology & Laboratory Services to establish a Cost per Test agreement for Automated Erythrocyte Sedimentation Instrumentation. New equipment shall be acquired for each of the clinical laboratories located at the VISN facilities listed in Attachment A. Facilities within VISN 15 may be added or deleted by supplemental agreement of the Government and the Contractor. As requirements change, facilities within VISN 15 (Attachment A) may be added or deleted. Pricing to add new sites and/or equipment would be based on the costs spread out over the life of the remaining contract. Additional tests/reagents/instrumentation may be added to the BPA as new technology becomes available on the market and added to the base FSS contract. VISN 15 intends to establish the base year of the agreement for the period of 05/01/2026 through 04/30/2027. This will be a single award, firm-fixed price with 5 ordering periods. The instrument shall have random access capability (if discrete testing is required) and be able to simultaneously perform the complete testing as described below meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). A total equipment footprint that when installed in the laboratory shall not impact on the functionality/operations of that laboratory. Equipment must maintain or, preferably, reduce the number of workstations or overall labor required to accomplish the required testing by each laboratory. If Contractor offers a family of analyzers, the technical evaluation panel will determine if instrumentation proposed meets needs of using facility. The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration dates must be clearly marked on reagent, standard, and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. Estimated volumes of reagents can be found in Attachment A. Validation of new equipment must complete 30 days before expiration of current contract (April 30, 2026). DEFINITIONS: Cost per Patient Reportable Result (CPRR)- as defined in the Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers - Contractors are required to provide a price for a reportable patient result. The per patient reportable result price shall include costs covering: (1) 5-year equipment use, (2) all reagents, standards, quality controls, supplies, consumable/disposable items, parts, accessories and any other items required for the proper operation of the Contractor s equipment and necessary for the generation of a patient reportable result. This per patient reportable result price shall also encompass all costs associated with dilution, repeat and confirmatory testing required to produce a single patient reportable result. It shall also include the material to perform as well as all other costs associated with quality control, calibration and correlation study testing that is prescribed by the Clinical and Laboratory Standards Institute (CLSI). (3) all necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and (4) training for Government personnel. Contractors shall provide delivery, installation and removal of equipment at no additional charge. Business Associate Agreement (BAA)- A business associate is an entity, including an individual, company, or organization that, on behalf of VHA, performs or assists in the performance of functions or activities involving the use or disclosure of PHI, or that provides certain services involving the disclosure of protected health information (PHI). VHA is a covered entity under the HIPAA Privacy Rule (Privacy Rule). HIPAA regulations require VHA to execute HIPAA-compliant BAAs with certain entities that receive, uses, or discloses VHA PHI to perform some activity for VHA. These BAAs obligate VHA business associates to provide the same protections and safeguards to PHI that is required of VHA under the Privacy Rule. GENERAL REQUIREMENTS: Primary analyzer(s) Base equipment offered that shall fully support the scope of operations (minimal requirements). Depending upon the technical functionality and the capabilities of the individual manufacturer s instrumentation, one analyzer or multiple analyzers may be required to meet the productivity specifications defined herein. In those instances, the additional analyzer(s) shall, likewise, be considered primary instrumentation and shall meet all the technical specifications of this solicitation. Those additional analyzers(s) offered meeting the definition of a primary analyzer may serve as a back-up analyzer (see definition below) and shall replace the requirement for offering that category of equipment. Back-up Analyzer does NOT apply; equipment required in support of operations for the VA laboratories in the event the primary analyzer(s) becomes non-operational/non-functional. This category of equipment (loaners) shall only be operated during periods of time when the primary instrumentation is not available for use. As such, the requirements for consumable supplies, i.e. reagents, quality control material, calibrators, etc., shall be minimal and corollary to the successful operation of the primary instrumentation. Additional primary analyzers required for the performance of daily workload are not considered back-ups for the purposes of consumables, reagents, etc. Operational/Technical Features -The instrumentation offered shall have the following: Testing Instrumentation - The testing instrumentation must be approved by the Food and Drug Administration (FDA) and shall have the following: The capability of performing analysis of Erythrocyte Sedimentation Rate (ESR) The capability and throughput to meet the volume and service demands as defined in Attachment A. QC data management system and includes Levy-Jennings graphs. Analyzer must have the ability to capture & store QC data. Capability to detect and alert operator of out-of-range quality control results via flagged results on QC printout and visual alerts on display monitor. Ability to participate in peer data management system for quality control results. On board reagent inventory management must have: A system that provides reagent data to include but not limited to lot number and expiration date of reagents and quality control. Barcoding of reagents. On board reagent stability sufficient to accommodate both high and low volume use. Primary tube sampling from evacuated whole blood EDTA collection tubes from various manufacturers. The ability to continuously load patient specimens. The ability to detect short samples. The ability to perform testing on samples with 0.5 ml of whole blood. The ability to perform mixing of samples on board the analyzer. The ability to measure directly the intensity of red cell aggregation. Hardware Features- The instrumentation shall have the following: All monitors/screens will clearly display information in all light conditions. A printer that has the capability of printing a patient report with patient demographic information. that includes minimally the patient s name and accession or unique identifier number (UID). Interface Requirements A bi-directional, bar-coded computer interface compatible with the current VA laboratory information system and future system, Oracle Health (Formerly known as Cerner). The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. Equipment must accept, at a minimum, 10 characters in specimen identifier that is alphanumeric that may be enabled concurrently. A barcode reading accuracy rate of 99% or greater. The Contractor shall be responsible for providing all hardware required for the connection, implementation, and operation of the interface to the universal interface and any incremental fee that is required each time an instrument is added to an existing universal interface system (see Attachment A). Analyzer must have a bi-directional HL7 interface with Dual TCP/IP capability. The vendor shall provide assistance with setting up Autoverification through Data Innovations, and work with the Laboratory LIMs to interface VISTA LIS with vendor provided instruments. Provide remote or onsite guidance on validation techniques and assist troubleshooting. Provide support and guidance during modifications of final Autoverification build. For example, modifying rules logic cutoff based on evolving SOPs. The Contractor shall provide any and all necessary software support for ensuring that successful interfacing has been established. Specific requirements for the communication of the data streams will be unique to the instrument system involved and dictated by the manufacturer itself. Information necessary to make the determination for type and amount of interfacing equipment is supplied in Attachment A. If a site already has a universal interface box, the Contractor is responsible for everything leading up to the box including any incremental fee required to add additional equipment (e.g. licenses, ports/cards, cables, software, etc.) to the universal interfacing system. If a site does not have a universal interface and one is needed to optimally interface the instrument, then the Contractor is responsible for the acquisition of the universal interface box and everything else needed to connect with VA computerized hospital information system. If there are any software upgrades in the instrument during its life, the Contractor is responsible for seeing that the interface can accommodate any changes in the data stream going to the VA computerized hospital information system. Analyzer must function using an operating system that is approved to connect to the VA computer systems. Vendor must complete the following documentation that is attached to the solicitation: 6550 Pre-Procurement Assessment MDS2 ACL Communication Profile Current ISA/MOU and BAA with the VA, if applicable Contractor shall provide that are applicable for remote connection to the interface system used to manage the testing system. Method Performance/Validation Requirements Method performance/comparison shall be completed by and at the expense of the Contractor, shall include linearity material and reagents, and be consistent with current CLSI guidelines and related documents, College of American Pathologists (CAP) standards and Federal regulations. Correlation studies for each analyte. A minimum of 40 samples spanning the reportable range, shall be run by the present and the proposed method. In systems where multiple sampling modes exist, mode to mode correlation studies must also be performed. Contractor shall analyze results and provide statistical data to support acceptance of the new method for above studies. Statistics shall consist of at least mean, bias, slope, y-intercept, correlation coefficient, ROC analysis, and meet current standards defined by CLSI. Analytical Measurement Range (AMR) Validation shall be performed on proposed instrument(s) for each analyte to validate the reportable range. The material must have values which are near the low, mid, and high values of the AMR and be of appropriate matrix for the clinical specimens assayed by that method. A minimum 5-point linearity analysis that adheres to the Beer-Lambert Law and spans the entire range shall be performed as a minimum. Precision studies using normal and abnormal control material. This shall consist of a within-run precision study of 10 normal and 10 abnormal controls and a day-to-day precision study of normal controls and abnormal controls for 10 days (maybe run twice a day) for a total of 20 values per level of control. Intra-VISN facility variations should be kept at an absolute minimum. Sensitivity. Sensitivity may be validated concurrently with correlation studies. Mathematical calculations to determine efficiency, sensitivity, false positive rate, and false negative rate are applied. Specificity Studies. A review of product literature and assay inserts to determine any adverse effects for increased bilirubin, hemolysis, lipemia, or other interrupting substances. Reference Range A reference range must be determined for each test following CLSI Guidelines. Samples used for the reference range study must be representative of the patient population being tested. One of the following protocols shall be used: A verification of the manufacturer s suggested reference range may be performed as long as the suggested range is based on a comparable population of test subjects. The manufacturer shall provide specific information defining how the suggested range was determined. A minimum of 20 reference individuals shall be used to verify the manufacturer s range. Any apparent outliers should be discarded, and new specimens obtained to provide a statistically valid verification. If the suggested manufacturer s range is not appropriate for the patient population, a reference range shall be established. Establishing a reference must follow CLSI guidelines. This requires a minimum of 120 reference individuals to be used to establish a reference range. The reference interval should be determined using the nonparametric method. OTHER REQUIREMENTS: Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. Support Features-The equipment models being offered shall be in current production as of the date this offer is submitted. Current production shall mean that the clinical laboratory analyzer model is being offered as new equipment. Discontinued models that are only being made available as remanufactured equipment are not acceptable. Commercial marketing. The equipment models being offered shall be in current production as of the date this offer is submitted. For purposes of this solicitation, current production shall mean that the clinical laboratory analyzer model is being offered as new equipment. Discontinued models that are only being made available as remanufactured equipment are not acceptable. Commercial offerings. The Contractor shall provide any additional support material that is routinely provided to equivalent commercial customers and assists in regulatory compliance, e.g. Computer disc containing their procedure manual in CLSI format or an online procedure manual in the instrument software. Start-Up Reagents. The Contractor shall provide all reagents, calibrators, controls, consumable/disposable items, parts, accessories and any other item included on the list of supplies defined in the Federal Supply Schedule contract and required to establish instruments for operation for performance of acceptance testing. The Contractor shall perform, to the satisfaction of the Government, all validation studies including precision, method comparison with current analyzer, accuracy (recovery), calibration verification, verification of reference interval, and determination of sensitivity and specificity at no cost to the Government. The Contractor shall perform all of the statistical analysis as stated in the Method Performance/Validation section above and report data in an organized, clearly comprehensible format. Training. Upon Installation: The Contractor shall provide advanced (key operator) instrument training program for at least two operators per facility at no charge to the Government that is coordinated with and timely with the equipment installation, sufficient to the size and scope of the facility s services and minimally equivalent to the terms and conditions for training defined in the Contractor s Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers contract. This shall include training on the operation of the system, data manipulation, and basic troubleshooting and repair. Thereafter: The Contractor shall provide training for minimally one operator per facility per year at the discretion of the Government for each model of instrumentation placed. Utilization of the training slots shall be mutually agreed upon between the VA and the Contractor. A training program that involves off-site travel shall include the cost of airfare, room, and board for each participant. Service Requirements- Equipment Preventative Maintenance/Repair Service. The Contractor shall be able to provide emergency equipment repair and preventative maintenance on all primary and back-up instrumentation and any incremental support equipment, e.g. water system, offered according to the following terms: A technical assistance center shall be available by telephone 24 hours per day, 7 days per week with a maximum call back response time of 1 hour. Equipment repair service shall be provided during core business hours. See Attachment A defining core business hours of each facility included in this solicitation. Certain circumstances may dictate the need for repair service to be conducted outside routine business hours. All such arrangements shall be coordinated between the Contractor and VA laboratory personnel. Equipment repair response time shall be no more than 24 hours. Preventative maintenance will be performed as frequently as published in manufacturer s operator s manual and within 2 weeks of the scheduled due date. A malfunction incident report shall be furnished to the Laboratory upon completion of each repair call. The report shall include, as a minimum, the following: date and time notified, date and time of arrival serial number, type and model number of equipment, time spent for repair, and proof of repair that includes documentation of a sample run of quality control verifying acceptable performance. Each notification for an emergency repair service call shall be treated as a separate and new service call. Upgrades - The Contractor shall provide upgrades to the equipment hardware, bidirectional interface and software in order to maintain the integrity of the system and the state-of the art technology, at no additional charge to the Government if sites are interested. These shall be provided as they become commercially available and at the same time as they are being provided to commercial customers. This requirement only applies to system upgrades that enhance the model of equipment being offered, i.e. new version of the software, correction of a hardware defect, upgrade offered to commercial customers at no additional charge, upgrade to replace the model of equipment no longer Contractor supported, etc. This does not refer to replacing the original piece of equipment provided under the BPA; however, it does refer to significant changes in the hardware operational capability. Ancillary support equipment - The Contractor shall provide, install and maintain through the life of the BPA, as indicated, any and all ancillary support equipment to fully operate the analyzer as defined in these specifications, e.g. universal interface equipment. In addition, the Contractor shall include all ancillary components that are customarily sold or provided with the model of equipment proposed, e.g. starter kits, etc. Characterization of waste- The Contractor shall provide documentation that it has characterized the hazardous nature of all wastes produced by all equipment, devices, reagents, and discharges in accordance with the requirements of the Code of Federal Regulations Title 40 Protection of the Environment Part 261 et seq. and applicable state and local requirements. Documentation shall include a description of the characteristics of the hazardous waste produced as a byproduct of the instrument operations, Safety Data Sheets (SDS) meeting the requirements of the Occupational Safety and Health Administration (OSHA) and Environmental Protection Agency (EPA), the analytical process used to determine the hazardous nature and characteristics of the waste, and the analytical test results. Testing of hazardous waste is to be done in accordance with testing protocol specified for each individual waste as described in the Code of Federal Regulations Title 40 to make a determination if the waste is a hazardous waste or otherwise regulated. The determination and description shall address the following: Waste toxicity (Reference 40 CFR §261.11 and 40 CFR §261.24) Waste ignitability (Reference 40 CFR §261.21) Waste corrosivity (Reference 40 CFR §261.22) Waste reactivity (Reference 40 CFR §261.23) Hazardous waste from non-specific sources (F-listed) (Reference 40 CFR §261.31) Discarded commercial products (acutely toxic or P-listed and toxic or U-listed) (Reference 40 CFR §261.33) Solid Waste (Reference 40 CFR §261.2) Exclusions (Reference 40 CFR §261.4) The contractor will provide written instructions and training material to ensure VHA laboratory staff are trained as needed to properly operate devices with special emphasis on managing and disposing of hazardous waste in accordance with EPA and state requirements. Additionally, the training provided by the contractor must fulfill Resource Conservation and Recovery Act (RCRA) requirements for training as applicable to devices. Contractor shall provide a description of all wastes the process or equipment may discharge so that the facility can determine whether the discharge meets Local Publicly Owned Treatment Works (POTW), State and Federal discharge requirements. At a minimum the characteristics of ignitability, corrosivity, reactivity and toxicity as defined in 40 CFR §261 must be determined and documented. Any mercury containing reagents must be identified in any concentrations. All test results shall be provided. All listed chemicals (F, U, K and P) found in 40 CFR §261 shall be provided in product information and their concentrations documented. For those materials with positive hazardous waste determination, a mechanism for the laboratory to meet local discharge requirements (i.e. mercury, thimerosol and formaldehyde) must be developed and SDS sheets must be provided in advance for review. At a minimum, documentation shall include, but not be limited to the concentration/measures of the elements and parameters listed below and must be included with vendor response: Barium (Total) Cadmium (Total) Chromium (Total) Copper (Total) Cyanide (Total) Lead (Total) Mercury (Total) Nickel (Total) Silver (Total) Zinc (Total) Arsenic (Total) Selenium (Total) Tin (Total) pH Flash point (to higher than 200°F) BOD; biochemical oxygen demand The documentation the contractor provides will be used to work with the VAMC and the public and/or private organization (e.g., POTW) to determine whether the waste from each device can legally be disposed of via the sewerage system. Implementation/transition timeframe - The implementation of the services/requirements described in this solicitation shall be completed no later than 90 days after the award. This timeline is based on a reasonable attempt of the Contractor to complete all of the necessary implementation requirements within the stated timeframe. Contractor shall not be penalized for implementation timelines that extend beyond the 90-day timeframe, if the extension is through no fault of the Contractor and is a result of delays due to the Government. Upon award, the transition period for the awarded agreement to have all equipment and peripherals installed and operational shall be from the date of award through 90 days. During this same period all initial training of VA personnel in the operation and maintenance of said award shall also be completed. Contractor shall provide with its quotation an implementation plan for installation of new equipment. Contractor s submitted plan shall not exceed 90 days for the transition of all services under the awarded BPA including installation and training of personnel, transition of all testing materials, reagents and supplies, etc., performance of all correlations and validations. Failure of the Contractor to conform to the transition period shall be considered as sufficient cause to terminate BPA for cause under the Termination for Cause clause of the BPA. At the end of 90 days from award of the BPA, the awarded Contractor shall have full and sole responsibility for services under the awarded BPA. Standard and Quality of Performance- This paragraph establishes a standard of quality performance that shall be met before any equipment listed on the delivery order [or BPA] is accepted by the Government. This also includes replacement, substitute machines and machines that are added or field modified after a system has demonstrated successful performance. The acceptance period shall begin on the installation date. It shall end when the equipment has met the standard of performance for a period of 30 consecutive calendar days by operating in conformance with the Contractor s technical specification or as quoted in any BPA at an effectiveness level of 90% or more. In the event that equipment does not meet the standard of performance during the initial 30 consecutive calendar days, the standard of performance tests shall continue on a day-by-day basis until the standard of performance is met for a total of 30 consecutive days. Operational use time for performance testing for a system is defined as the accumulated time during which the machine is in actual use. System failure downtime is that period of time when any machine in the system is inoperable due to equipment failure. Downtime for each incident shall start from the time the Government makes a bona fide attempt to contact the Contractor s designated representative at the prearranged contact point until the system or machine(s) is returned to the Government in proper operating condition. During the performance period for a system, a minimum of 100 hours of operational use time with productive or simulated work shall be required as a basis for computation of the effectiveness level. However, in computing the effectiveness level, the actual number of operational use hours shall be used when in excess of the minimum of 100 hours. [reference: Master FSS] The Government will maintain daily records to satisfy the requirements of the Standard and Quality of Performance section and shall notify the Contractor in writing of the date of the first day of the successful period of operation. Operations use time and downtime shall be measured in hours and whole minutes. During the term of the BPA, should the repair record of any individual piece of laboratory equipment reflect a downtime of 10% or greater of the normal working days in one calendar month, a determination shall be made by the COR to replace the malfunctioning equipment with new equipment. The responsibility for maintaining the equipment furnished in good condition in accordance with manufacturer s instructions, shall be solely that of the Contractor. [reference: Master FSS]. Each instrument provided by the Contractor shall maintain an uptime of 90% in each month of the term of the agreement for equipment. Government s Responsibility- The user will perform routine maintenance and cleaning as required in the manufacturer s operation and maintenance instructions. The user shall maintain appropriate records to satisfy the requirements of this paragraph. Ownership of Equipment- Title to the equipment shall remain with the Contractor. All accessories (unused consumables, etc.) furnished by the Contractor shall accompany the equipment when returned to the Contractor. The Contractor, upon expiration of order(s), at termination and/or replacement of equipment, shall remove the equipment. The Contractor shall disconnect the analyzer (gas, water, air, etc.) and shall be responsible for all packing and shipping required to remove the analyzer. The Contractor will identify if removable media is required to perform their duties. The Clinical Engineering Department will ensure the removable media is scanned with anti-virus software running current virus definitions prior to connection to any medical device/system. Any Contractor with patient sensitive information that is imported into the removable media device for any reason must purge all patient sensitive information prior to departure from the facility. Prior to termination or completion of this BPA, Contractor/subcontractor must not destroy information received from VA, or gathered/created by the Contractor in the course of performing this BPA without prior written approval by the VA. Any data destruction done on behalf of VA by a Contractor/subcontractor must be done in accordance with National Archives and Records Administration (NARA) requirements as outlined in VA Directive 6300, Records and Information Management and its Handbook 6300.1 Records Management Procedures, applicable VA Records Control Schedules, and VA Handbook 6500.1, Electronic Media Sanitization. Self-certification by the Contractor that the data destruction requirements above have been met must be sent to the VA Contracting Officer within 30 days of termination or completion of the BPA. All electronic storage media used on non-VA leased or non-VA owned IT equipment that is used to store, process, or access VA information must be handled in adherence with VA Handbook 6500.1, Electronic Media Sanitization upon: (i) completion or termination of the BPA or (ii) disposal or return of the IT equipment by the Contractor/subcontractor or any person acting on behalf of the Contractor/subcontractor, whichever is earlier. Media (hard drives, optical disks, CDs, back-up tapes, etc.) used by the Contractors/subcontractors that contain VA information must be returned to the VA for sanitization or destruction or the Contractor/subcontractor must self-certify that the media has been disposed of per 6500.1 requirements. This must be completed within 30 days of termination or completion of the BPA or disposal or return of the IT equipment, whichever is earlier. Bio-Medical devices and other equipment or systems containing media (hard drives, optical disks, etc.) with VA sensitive information must not be returned to the Contractor at the end of lease, for trade-in, or other purposes. The options are: Contractor must accept the system without the drive VA s initial medical device procurement includes a spare drive which must be installed in place of the original drive at time of turn-in; or VA must reimburse the company for media at a reasonable open market replacement cost at time of purchase. Due to the highly specialized and sometimes proprietary hardware and software associated with medical equipment/systems, if it is not possible for the VA to retain the hard drive, then; The equipment Contractor must have an existing BAA if the device being traded in has protected health information stored on it and hard drive(s) from the system are being returned physically intact; and Any fixed hard drive on the device must be non-destructively sanitized to the greatest extent possible without negatively impacting system operation. Selective clearing down to patient data folder level is recommended using VA approved and validated overwriting technologies/methods/tools. Applicable media sanitization specifications need to be pre-approved and described in the purchase order or BPA. A statement needs to be signed by the Director (System Owner) that states that the drive could not be removed and that (a) and (b) controls above are in place and completed. The Information Security Officer (ISO) needs to maintain the documentation. Attachments

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Erika Kobulnicky
Contract Specialist

Documents

Files (1)

  • 36C25526Q0092.docx

    65 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    6640--VISN 15 Automated Erythrocyte Sedimentation Rate Analyzers - 36C255-26-AP-0538

    Notice 2bc171622b914ee08c5ad11acba6170c on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
PROTEINSIMPLE JESS AUOTMATED PROTEIN ANALYSIS SYSTEM
76%
Solicitation11/18/2026
NOTICE OF INTENT TO SOLE SOURCE: The Department of Veterans Affairs Network Contracting Office 6 intends to award a sole source, firm-fixed-price contract to PROTEINSIMPLE for the Jess Western Automated System for the Salem, VA Medical Center, Salem VA in accordance with Revolutionary FAR Overhaul (RFO) 12.201-1, Simplified Procedures. Justification for this sole source procurement is in accordance with Revolutionary FAR Overhale (RFO) 6.103.1 soliciting from a single source. This notice of intent is not a request for competitive quotes. No solicitation documents are available, and telephone requests will not be accepted. However, any business that believes it can meet these requirements and possesses relevant past-experience and expertise may give written notice. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. Responses will be considered by the Government, however, a determination by the Government not to compete with the proposed acquisition based upon responses to this notice is solely within the discretion of the Government. NAICS Code 334516- Analytical Laboratory Instrument Manufacturing with a size standard of 1,000 Employees. Description: Jess Automated Western Blot System: The Jess system is an automated capillary electrophoresis based immunoassay platform that modernizes traditional Western blotting by combining protein size separation with high sensitivity immunodetection in a fully hands off workflow Responses received by 9:00 am EST on 03 November 2026 will be considered by the Government. Inquiries shall be emailed to James.risbon@va.gov No telephone requests will be accepted. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES, and no Solicitation will be issued. The justification for this noncompetitive solicitation is due to ProteinSimple being the sole company capable of providing a suite of cryoablation services which includes technicians, equipment, and the required disposables. Market research has determined that this service is highly specialized and only available from a single source. The Government intends to award the contract with an effective date of 06 November 2026 to ProteinSimple, 614 McKinley Place NE Minneapolis, MN 55413.
76%
Special Notice11/03/2026
Sources Sought Notice Sources Sought Notice Page 5 of 5 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 5 This is NOT a solicitation or request for quote. This is NOT a request for proposal. This is NOT a job advertisement for hiring employees. The VA is seeking QUALIFIED VENDORS to provide a very brief response to this notice including only just what is asked for in this notice below. This is sources sought notice to industry and the only information is posted on Contract Opportunities web page at SAM.gov. Sources sought means seeking qualified vendors. The attachments included on the Contract Opportunities page do not include any additional information. If your company is interested, please read this notice entirely and submit the required information, as requested herein. Automated Blood Culture Analyzers and Bottles Four (4) VA Medical Centers: Fort Harrison, MT, Cheyenne, WY, Grand Junction, CO and Sheridan, CO BRIEF SCOPE OF WORK (This is for information only) IMPORTANT NOTE: This Sources Sought is for market research purposes only (to determine the socioeconomic status of interested companies). No award will be made off this posting. The four (4) VA medical centers each require an automated blood culture analyzer with corresponding blood culture bottles. It is anticipated the blood analyzer would be provided to each facility for use for a base period (1 year) with four (4) additional optional years. **The current blood culture analyzer in use at each facility is the BD (Becton Dickinson) BACTEC FX40 Automated Blood Culture System** Overview of Items (5-years): Line Item # Description Unit Base Yr Qty OY#1 Qty OY#2 Qty OY#3 Qty OY#4 Qty Fort Harrison, MT 0001 Blood Culture Analyzer EA 1 1 1 1 1 0002 Blood Culture Management Computer and Software EA 1 1 1 1 1 0003 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 26 26 26 26 26 0004 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 26 26 26 26 26 0005 BOTTLE PLASTIC Myco F Lytic 50/PK PKG 3 3 3 3 3 0006 Connectivity & Workflow Management EA 1 1 1 1 1 Cheyenne, WY 0007 Blood Culture Analyzer EA 1 1 1 1 1 0008 Blood Culture Management Computer and Software EA 1 1 1 1 1 0009 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 28 28 28 28 28 0010 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 28 28 28 28 28 0011 BOTTLE PLASTIC PEDS PLUS/F 50/PK PKG 4 4 4 4 4 0012 Connectivity & Workflow Management EA 1 1 1 1 1 Grand Junction, CO 0013 Blood Culture Analyzer EA 1 1 1 1 1 0014 Blood Culture Management Computer and Software EA 1 1 1 1 1 0015 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 20 21 22 23 24 0016 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 20 21 22 23 24 0017 BOTTLE PLASTIC PEDS PLUS/F 50/PK PKG 1 1 1 1 1 0018 Connectivity & Workflow Management EA 1 1 1 1 1 Sheridan, CO 0019 Blood Culture Analyzer EA 1 1 1 1 1 0020 Blood Culture Management Computer and Software EA 1 1 1 1 1 0021 BOTTLE PLASTIC AEROBIC/F 50/PK PKG 12 12 12 12 12 0022 BOTTLE PLASTIC LYTIC/ANAEROBIC/F/F 50/PK PKG 12 12 12 12 12 0023 Connectivity & Workflow Management EA 1 1 1 1 1 0024 Remote Alert System (After Hours) EA 1 1 1 1 1 Statement of Work: 1.0 Scope of Work The microbiology department of the Pathology and Laboratory Medicine Service (P&LMS) requires a cost per bottle contract to provide new automated Blood Culture instruments for use at the Ft. Harrison campus of the VA MT Healthcare System, Cheyenne VAMC, Sheridan VAHCS, and Grand Junction VAMC. Equipment and supplies must be installed, fully approved by the station team, and ready for use no later than May 1st, 2027. The awarded contract will have a one-year base period with four annual option periods. 2.0 Tasks The vendor shall provide all automated blood culture instruments, supervision, parts, labor, software, preventative maintenance, materials, and incidentals in order to ensure fully successful blood culture test and meet or exceed all listed requirements in the specifications below. 2.1 General Requirements Requirements, as set forth in this statement of work are minimum standards and shall not be construed as limiting the overall quality, quantity, or performance of the instrument. The vendor shall maintain the performance and overall quality of all instrument systems during the period of performance to all software upgrades, equipment, maintenance, parts, and labor to ensure full functionality and currency of new automated blood culture instruments. The instrument system, based upon the specifications requested, shall be the newest and the most current model. Refurbished systems are not acceptable. The instrument must be a standard product of the manufacturer of record. The manufacturer of record is defined as a company whose main occupation is the manufacture for sale items of equipment and which: Maintains a factory production line. Maintains a stock of replacement parts for the item. Maintains engineering drawings, specifications, operating manuals and maintenance manuals. Has published and distributed descriptive literature and equipment specifications on the equipment. The analyzer cabinet/instrument shall be a countertop model fitting within the following available spaces: Montana 75 in W x 45 in D Cheyenne 45 in W x 30 in D Grand Junction 87 in W x 30 in D Sheridan 31 in W x 36 in D If the proposed analyzer does not fit the dimensions of any of the stations above, a contractor provided cart may be used if the station agrees and has the room for it. All equipment/supplies/bottles and software must be FDA-approved at time of award 2.2 System Requirements The instrument system shall meet the following requirements: Use plastic and glass culture bottles that are specific to the instrument system and the culture bottles used in the instrument should contain a neutralizing resin media for the aerobic culture bottle and a lytic broth media for the anaerobic culture bottle. + Be able to accept and analyze blood, fungal and an acid, fast, bacteria (AFB) culture bottles. Be able to accept and analyze both blood and body fluid specimens. Utilize a varied selection of blood culture bottle configurations (low volume samples; antimicrobial agent removal resins) and formulations capable of maximizing growth potential of various microorganisms (e.g. aerobic and anaerobic bacteria, fungi, and mycobacteria) shall be available. Have the capability to flag and alert the end-user of positive culture vials by simultaneous visual alert, sound alert and remote alert using existing software programs. The Sheridan VAMC lab does not run 24/7 so the contractor shall provide a system by which their AODs (Administrative Officer of the Day) can monitor the system remotely 24 hours per day. Provide self-contained, continuous, computerized, automated monitoring of blood culture bottles with immediate, active (e.g. audible alarm) notification of microorganism growth based upon pre-programmed criteria and notification of termination of maximum programmed incubation period when no microorganism growth is detected. Allow for operator extension of programmed incubation times while testing is in progress, without interruption of automatic continuous monitoring. Have the capability to monitor the blood volume in each culture bottle. Utilize sufficient safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. Have the capability to detect and document elapsed time to positivity. Have bar code reading capability to eliminate the need for manual entry of patient information for each sample. Contractor bar code formats shall meet requirements of VA lab information system software. Have the capability to scan the culture vial sequence and specimen accession label in any order. Have the capability to accept the culture vial in any available station. Have the ability to provide automated transmission of test results into the laboratory s current laboratory information system LIS. Contractor must be able to send information through Data Innovations (DI) instrument server and have DI driver available. Must provide all hardware and software needed to connect via TCP\IP protocol, as well as communicate with government VISTA protocols and system. Utilize Food and Drug Administration (FDA)-cleared software. Contain a report module that has the ability to generate epidemiology and statistical reports. Contain a data management system that allows users to monitor and analyze data. Provide printed paper results in the event of computer down time. Have the ability to electronically archive patient results. Have the ability to generate cumulative quality control (CQC) reports. 2.3 Instrument Requirements When requested, the instrument cabinet should be able to hold a minimum of 200 culture bottles Some facilities may have smaller minimum volume requirements. The vendor should have a variety of instrument sizes and types to accommodate the estimated annual volume requirement for each facility. The instrument should take up minimal space and have the ability to stack incubation cabinets on top of each other. The instrument should require only minimal maintenance by government personnel. The instrument must include an on-board programming display and be user friendly. The instrument system must include a 120-volt Uninterrupted Power Source (UPS) system that has a 30-minute backup capability in the event of electrical power interruptions. The system should also have provisions for saving data in the event that the capacity of the UPS is exceeded. The vendor shall provide all software upgrades and a field technical representative from the instrument manufacturer shall install the updated software at no charge within a reasonable time and shall coordinate with the laboratory supervisor. The instrument system shall have the ability to accept upgrades so as to accommodate the need for increased testing volume. Software must be compatible with Bruker MALDI bio-typer 2.4 Supply Requirements The vendor shall: Supply a variety of plastic and glass culture bottle types and allows flexibility in the selection of culture bottle types required based on facility needs. Shall provide customer helpline telephone numbers for VAMC laboratory technicians to the call-in routine and emergency supply request. The vendor shall supply all necessary point of contact information and ordering procedures for VAMC laboratory technicians to order reagents and other supplies for both a standing delivery schedule basis or on an as-needed basis. Fill routine and emergency supply requests when requested. Pay shipping fees for all supplies, consumables, and equipment needed to perform installation start-up testing. Provide ancillary components that are necessary for the model of equipment proposed (i.e. starter kits, tables, stands, etc.). List all reagents, controls and disposables required for operating the instrument and producing quality results as an addendum in the pricing schedule. 2.5 Repair & Maintenance Services The manufacturer shall provide technical support either by phone or on-site. Service should include all travel, parts for repair or replacement, and labor. The vendor shall provide a preventative maintenance schedule to include a minimum of one scheduled preventative maintenance visit per year. The vendor shall be responsible for the removal of the hard drive of the analyzer upon removal/upgrade of the instrument. The hard drive shall be given to the laboratory VA information system manager for disposal. The service shall include replacement or repair of all ancillary equipment (i.e. printers, monitors, UPS) necessary for the system to operate efficiently. 2.6 Pre-Installation Assessment The vendor shall provide written information detailing all maintenance, environmental, and utility requirements (electrical, dimensions of equipment, media disposal, etc.) as part of their proposal to include the following information. If the equipment proposed is particularly heavy, advisement of extra reinforcement shall be necessary. Provide dimensions of the system. List utility requirements (electrical, heat/cool, humidity, etc.) Describe testing methodology. List quality control (QC) frequency. Describe maintenance requirements for daily/weekly/monthly maintenance. Describe any environmental impact issues that instrumentation may create (water requirements, media disposal, etc.). Describe user friendliness: Describe software and/or supporting instrumentation provided with the system to maintain or improve levels of data retrieval which may be used for monitoring epidemiology trends. Describe reagent management (storage and waste). Describe ability to trouble-shoot system. Describe how system alerts user of positive and negative culture bottles. Provide list of reagent recalls/bulletins within the last two years. List reagent unavailability due to manufacturing issues within the last two years. Environmental requirements (heat/cool, humidity, light, etc.) and recommendations for instrument and testing material storage. Manufacture s maintenance requirements indicating what maintenance is performed by the end-user and what maintenance is performed by the manufacturer by providing outline or brochure outlining frequency of preventative maintenance. 2.8 Laboratory Information System (LIS)/Interface Software must be compatible with all barcode styles and have proven bi-directional interface capability with the laboratory s current LIS. The vendor must provide additional hardware (i.e. middleware) and software needed to interface the system and provide technical assistance with interfacing the instrument system. Required (additional) interface connection license(s) shall be provided at vendor cost. The instrument-LIS interface must be bi-directional. The interface must use automatic host query to download sample, IDs, test requests, and patient demographics. Automatic host query must seamlessly integrate with on-board patient sample barcode scanning and translation. The instrument interface must transmit test results to the host computer system via automatic upload. Instrument system must have computer capabilities that are compatible with the end-user s LIS software and include an LCD display monitor and printer. The vendor shall provide technical support to link the instrument to the LIS interface and ensure that the instrument system is communicating properly. Vendor must successfully interface the analyzer via a Data Innovations Instrument Manager to the VA VISTA system. Must be compatible Bruker MALDI bio-typer 2.9 Support Services: The manufacture should have the ability to provide service sufficient to meet the needs of the end-user facility, 7 days a week, business hours for all sites. A field engineer must be available within 24 hours of after the service call has been placed. All repairs to the instrument must be complete within 24 hours from the time the field service engineer arrives. The vendor s staff shall designate in writing to the contracting officer a fully qualified primary and alternate Field Service Representative who has the authority and knowledge to respond to all technical/maintenance/repair issues. Fully qualified is based upon training and experience in the field. For training, the Field Service Representative must have successfully completed a formalized training program for the equipment covered under the contract. For field experience, the Field Service Engineers must have a minimum of one (1) year of experience providing preventative maintenance and emergency repair services on the same make and model of equipment covered under this contract. The vendor shall provide 24-hour, 7 days/week telephone technical support. The vendor shall submit a legible field service report to the laboratory supervisor itemizing the preventive maintenance inspection or emergency repair services performed, including replaced parts and estimated prices required for the service call. The vendor shall coordinate on all potentially hazardous safety issues with the contracting officer and laboratory supervisor. 3.0 Installation, including Instrument Validation & Training A technical support specialist from the instrument manufacturer shall assist in equipment installation/set-up, providing all manpower, procedures, and reagents/supplies to perform validation and correlation studies [evaluation/comparison data sufficient to satisfy College of American Pathologists (CAP) standards]. The vendor must provide required statistical analysis of the validation and correlation data in an organized binder for on-site director approval. The statistical analysis must be completed within eight weeks of installation of the system. The vendor/distributor and/or the manufacturer must provide all necessary procedure manuals, troubleshooting manuals and operator manuals. The vendor shall provide primary user training for a minimum of one user per instrument with on-site basic operating and maintenance education/training performed during initial installation and when updates to the equipment are performed. Training is to include all costs related to off-site training (transportation, room and board, etc. if applicable). Any additional costs such as industrial funding fees, special shipping and handling fees, or other usage fees must be included in the contract price or identified separately in the proposal. 4.0 Delivery and Acceptance 1. All items shall be shipped F.O.B. destination to the following locations M-F, 8am-4pm, excluding holidays: FT Harrison VAMC 3717 Veterans Drive Ft. Harrison MT 59636, Cheyenne VAMC 2360 East Pershing Blvd Cheyenne WY 82001 Sheridan VAMC 1898 Fort Road Sheridan WY 82801 Grand Junction VAMC 2121 North Avenue Grand Junction CO 81501 The Contractor, its employees, agents, and subcontractors shall not be considered VA employees for any purpose of fulfilling the PWS and shall be considered employees of the Contractor. Contractor shall furnish all labor, materials, equipment, tools, shipping, transportation, insurances, licenses, certifications, and supervision necessary to provide services in accordance with this Performance Work Statement (PWS). The Contractor is responsible for all charges and fees related to disposal of materials generated by the Contractor. This is anticipated to be a commercial supply acquisition under the authority of FAR Part 12, Simplified Acquisition Procedures for Commercial Items. The products will be delivered to the following locations: FT Harrison VAMC 3717 Veterans Drive Ft. Harrison MT 59636, Cheyenne VAMC 2360 East Pershing Blvd Cheyenne WY 82001 Sheridan VAHCS 1898 Fort Road Sheridan WY 82801 Grand Junction VAMC 2121 North Avenue Grand Junction CO 81501 IMPORTANT NOTE: This RFI (Request for Information) is for information only. No award will be made from this RFI. QUALIFIED VENDOR: A qualified source has the a) necessary equipment, vehicles, personnel, resources and current operations as well as b) recent experience (within past 3 years) of performing services of a comparable size, scope and complexity, AND c) OEM certified technicians to perform services with unrestricted access to the facility during inclement weather, as well as immediate access to OEM software updates. A qualified source also has current and valid registration in System for Award Management (SAM), https://www.sam.gov). Please communicate via e-mail to Stephanie.Cahill@VA.Gov by 15:00 MST on November 20th, 2026, as to your company s ability to perform service per this brief Scope of Work. If interested, please provide the following: Provide company s capability statement describing ability to provide equipment that meets or conforms to the salient characteristics listed above *include specification or brochure documents for confirmation of equivalent products* Company s business size in relation to NAICS 334516 and socio-economic category (SDVOSB/VOSB/WOSB/Large Business): SAM UEI: FSS/GSA contract # (if applicable): **Indicate Open Market if items are not included on FSS/GSA/etc.** Estimated delivery lead time: Where are the products manufactured/COO: Only written responses, to items 1 through 6 above, will be accepted at this stage. Information is being gathered for market research purposes only. Industry exchanges and vendor teleconferences are at the discretion of the Contract Specialist. This is not a request for quotes. DISCLAIMER: This is a Request for Information (RFI) from industry in accordance with Federal Acquisition Regulation (FAR) 15.201(e) and on the requirement, that exists for the VA Medical Center(s) identified in this RFI. This is not a request for quote and not a contract. This announcement is not a request for proposals; therefore, responses to the RFI are not considered offers and cannot be accepted by the Government to form a binding contract. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responders are solely responsible for all expenses associated with responding to this RFI. No classified information should be included in the RFI response. Should you have concerns regarding this RFI you may request to contact the Contracting Office that will be assigned this requirement by emailing the sender of this RFI. Questions must be addressed in writing to the Contract Specialist. Requests for VA-business sensitive information, to include VA budget information, VA acquisition planning information, acquisition methods, strategies and set-asides must be addressed via the VA FOIA process: https://www.va.gov/foia/ Thank you for your interest in doing business with the VA. To learn more about the VA Mission, Vision, Core Values & Goals visit https://www.va.gov/about_va/mission.asp To understand the latest updates on the Veterans First Contracting Program visit https://www.va.gov/osdbu/verification/veterans_first_contracting_program_adjustments_to_reflect_the_supreme_court_kingdomware_decision.asp To find out how to do business with the VA visit https://www.va.gov/osdbu/library/dbwva.asp
72%
Market Research11/20/2026
Please see attachments. This is a Full & Open Competiton requirement. The Contractor shall provide all the tools, parts, materials, labor, travel, installation, and training necessary to provide one halon analyzer consisting of one fully automated custom gas chromatograph system to the 802d Maintenance Group Chemical Analysis Flight (802 MXSS/MXDTA) at Robins Air Force Base (AFB), Georgia.
69%
Solicitation11/12/2026
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (ii) The solicitation number is 75N98027Q00024 and the solicitation is issued as a Notice of Intent (NOI) of a non-competitive (notice of intent) combined synopsis solicitation to award a contract or purchase order without providing for full or open competition (including brand-name). This acquisition is conducted under the authority of the FAR Part 12.603¿ Streamlined solicitation for commercial products or commercial services, and is not expected to exceed the simplified acquisition threshold, and the authority of 41 U.S.C. 1901 and the statutory authority of FAR 6.302-3(a)(2)(ii).
69%
Combined Synopsis11/05/2026

Additional Details

Solicitation Number

36C25526Q0092

Archive Date

Dec 20, 2025

Office Address

LEAVENWORTH, KS, 66048