Notice ID: 381367015a7d43369bd84ff2fb075b89Sources SoughtArchived
6515--Autotransfusion Equipment
Archived on July 27, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 8:00 AM CDT
- Posted
- July 9, 2026
- Notice type
- Sources Sought
- NAICS
- 339112: Surgical and Medical Instrument Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 255-NETWORK CONTRACT OFFICE 15 (36C255)
- Place of performance
- Kansas City VA Medical Center, Kansas City, MO, 64128
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C25526Q0502
- Notice ID
- 381367015a7d43369bd84ff2fb075b89
Description
SOURCES SOUGHT NOTICE REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT Autotransfusion Cell Saver Equipment THIS IS A REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this RFI/Sources Sought Notice is for market research purposes only, to obtain information in regards to the availability of specified products, services, or a combination of both products and services, and to identify potential sources capable of providing products or performing services in accordance with the requirements below. Responses to this notice will be used by the Government to make appropriate acquisition decisions. DISCLAIMER: This RFI/Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI/Sources Sought Notice that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. If a solicitation is issued it shall be published at a later date and all interested parties must respond to that solicitation announcement separately from the response to this RFI/Sources sought notice. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Submission of price, delivery, capabilities, and other market information are authorized. However, responses to these notices are not offers and cannot be accepted by the Government to form a binding contract IAW FAR 15.201(e). The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112. DESCRIPTION: The Department of Veteran Affairs, Network Contracting Office 15 (NCO 15) is seeking sources that can provide Autotransfusion Cell Saver Equipment and disposables in accordance with (IAW) the below requirement and North American Industry Classification System (NAICS) code 339112 (size standard of 1000 Employees). The purpose of this requirement is to purchase autotransfusion cell saver equipment and associated disposable supplies for patient care during surgical procedures at Kansas City VA Medical Center (KCVA). This device enables intraoperative autotransfusion during cases with anticipated blood loss, such as complex vascular procedures. This requirement covers the following: Purchase of autotransfusion cell saver machine. Provision of compatible single use disposable supplies (e.g., collection reservoirs, filters, tubing, anticoagulant syringes, reinfusion bags) compatible with cell saver machine. All preventative maintenance and equipment repair as needed. Training and ongoing clinical support and any equipment manuals. Equipment requirements: FDA-approved autotransfusion cell saver device suitable for intraoperative blood salvage and autotransfusion. Must meet applicable VA standards and regulations for safety and efficacy. Provide fully automated processing of collected blood, including separation, washing, and concentration of red blood cells for reinfusion. Have at least two selectable processing modes, including an emergency/rapid mode and a high-quality (standard) mode, to optimize clinical response. Accept multiple bowl sizes to include 125mL, 175 mL, and 225 mL to allow flexibility. Have automated priming, washing and reinfusion cycle. Have adjustable wash programs for optimal red blood cell salvage and customizable wash volumes. Must be single use, disposable set to ensure sterility. Provide high hematocrit (> 60%) and efficient removal of undesirable plasma, heparin, free hemoglobin, and other contaminants. Feature a large, color touchscreen display, with intuitive menu navigation and programmable protocol settings and built in data recording and storage capability-automatic documentation of case parameters for quality control and download. Have air and blood leak detection with automatic alarms. Secure, closed-circuit design to minimize contamination risk. Mobile, compact, lightweight and have locking wheels for use in various OR settings. Integrated battery backup for several hours of operation in the event of power loss. All patient-contacting components must be single-use, sterile disposables, and compliant with current infection prevention standards. Service: Must provide preventive and on-demand maintenance. Disposables: All necessary single-use consumable items compatible with equipment, including: Blood collection reservoirs Bowl sets required per case type Aspiration and anticoagulation line AAL ¼ suction assemblies Reinfusion bags Procedure sets required per case type Filters Anticoagulation syringes Compliance: All equipment and disposables must meet relevant VA, OSHA, and FDA standards and guidelines. Deliverables: Cell saver equipment installed and maintained. Disposable consumable supplies. VENDOR RESPONSE If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. 1. Company Name: 2. Company Address: 3. SAM UEI: 4. Company POC: 5. Phone Number: 6. EMAIL: 7. Is your company considered a small business IAW the NAICS identified in this RFI/Sources Sought Notice? If so, please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? 8. If your company is considered a large business, does your company have any authorized small business distributors/suppliers, service providers, and/or does your company sub-contract to small business concerns? If so, please provide the company name, company POC, and small business status (if available): 9. Is your company an authorized distributor/supplier and/or service provider (or equivalent) of the products and/or services identified in this sources sought? If so provide authorization letters and/or agreements from manufacturer. 10. Does your company alter, modify, or change the products identified in this sources sought? If so, please identify how the products are altered, modified, or changed. 11. Provide the country where the products are manufactured. 12. Does your company currently hold a Federal Supply Schedule (FSS) contract with GSA, the VA National Acquisition Center (NAC), NASA SEWP, VA Strategic Acquisition Center (SAC), or have any other federal contract that can be utilized to procure the products and/or services identified in this sources sought? 13. Please submit a capabilities statement that provides clear, compelling, and convincing evidence that your company can meet the requirements outlined in this sources sought. Responses to this notice shall be submitted via email to Tracie Raggs at tracie.raggs@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Friday, July 17, 2026, at 0800 CST.
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C25526Q0502.docx
29 KBAdded in Sources Sought version 3Posted
Lifecycle
- 3Version 3Sources SoughtArchivedCurrent
6515--Autotransfusion Equipment
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
PT Equipment for Rolla CBOC | - | Pre-Solicitation | 09/17/2026 |
PT Equipment for Rolla CBOC | - | Pre-Solicitation | 09/17/2026 |
Revision: 01 Effective Date: 11/15/2024 Acquisition ID#36C252-27-AP-0957 Page 1 of 2 Please note that this is not a request for proposal nor a request for quote as there is no solicitation document available. Therefore, this is a notice of intent issued by the Department of Veterans Affairs to negotiate a limited source contract with Iramed Corporation. DEPARTMENT OF VETERANS AFFAIRS Justification for Single Source Awards RFO FAR 12.102 For Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K) Acquisition Plan Action ID: 36C252-27-AP-0957 Contracting Activity US Department of Veterans Affairs Great Lakes Acquisition Center (GLAC) VISN 12 115 S. 84th Street Milwaukee, WI 53214 2237: 556-27-1-2993-0011 Brief Description of Supplies/ Services required and the intended use/Estimated Amount: The Captain James A. Lovell Federal Healthcare Center (FHCC), Building 556, Nursing Services, is requesting the acquisition of one MRI-compatible IV infusion pump system for the Intensive Care Unit (ICU). MRI-compatible infusion pumps are medically necessary for ICU patients who require continuous vasoactive or sedative titratable infusions while undergoing magnetic resonance imaging (MRI) to support the diagnosis and evaluation of complex disease processes. Estimated Amount: $105,270.20 Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used: The availability of this equipment will enable FHCC to perform medically necessary MRI examinations on-site, reducing the need to transfer patients to outside facilities. Currently, these patients are often taken for CT scans; however, CT imaging may not provide the comprehensive diagnostic information required for certain conditions Standardization and compatibility with the MRI IV infusion equipment currently installed at the facility are essential requirements for this acquisition. The requested system is intended to integrate with the existing equipment and support established clinical workflows, training, maintenance, and operational procedures. Substituting products from another manufacturer could result in incompatibility, require additional accessories or system modifications, necessitate staff retraining, and increase costs to the facility. Therefore, procurement of the compatible MRI IV Infusion Pump System is justified to maintain system continuity, operational efficiency, and patient-care capabilities. Description of market research conducted and results or statement why it was not conducted: Market Research Findings: An SBA.gov search under NAICS code 339112 identified zero (5) SDVOSBs and (13) VOSBs. Two additional searches were conducted on sba.gov by combining NAICS code 339112 with the keywords Quad Non-Magnetic IV Pump System and Non-Magnetic IV Pump System and applying specific filters for SDVOSBs and VOSBs. Both searches yielded zero (0) results. A search on GSA Advantage using the keywords Non-Magnetic IV Pump System produced several results that does not appear to meet the requirement. The Contracting Officer (CO) searched Google.com using the keywords Non-Magnetic IV Pump System and identified several vendors, including BD, BioSpace, Hospital & Healthcare management, Iradimed, InMed, MDPI, and Ivenix. Although several alternative vendors were identified, their products are not compatible with the MRI IV infusion equipment currently installed at the facility. Standardization and compatibility are essential requirements for this acquisition. The requested system is designed to integrate with the existing equipment and support established clinical workflows, training, maintenance, and operational procedures. Substituting products from another manufacturer could lead to compatibility issues, require additional accessories or system modifications, necessitate staff retraining, and increase facility costs. Therefore, procuring the compatible MRI IV infusion pump system is justified to ensure system continuity, operational efficiency, and uninterrupted patient-care capabilities. CO received a letter of authorization from the vendor that certifies Iradimed Corporation is the sole manufacturer and authorized seller of the MRidium 3870 MRI Infusion System and its accessories. Due to proprietary considerations, Iradimed Corporation is also the exclusive source for replacement parts for the MRidium MRI Infusion Pump System. The MRidium 3870 MRI Infusion System is the only nonmagnetic, MRI-compatible IV infusion pump currently available on the market. Contracting Officer's Certification: Purchase is approved in accordance with RFO FAR 12.102. I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief. Vernise L. Newton Contracting Officer | - | Special Notice | 11/17/2026 |
This market research notice is being conducted by Network Contracting Office (NCO) 17 VHA Regional Procurement Office-West (RPOW) 5441 Babcock Road Medical Center, 302 San Antonio TX 78240 for the procurement for the Multilab Series II Roorda Vascular System W/DICOM, integration capabilities for San Antoino Veterans Health Care System VA, TX 78229 Background and Requirement: San Antiona Veteran Healthcare System, 7400 Merton Minter, San Antonio, Tx 78229 is seeking a Multilabel Series II Roodra Vascular System W/DICOM. The purpose of this procurement is to acquire, deliver, install, test, and deploy four (4) Multilabel Series II Roodra Vascular Systems with DICOM integration capabilities. The required system is the Unetix Multilab II Roorda with DICOM functionality. The objective of this procurement is to provide the surgical service with advanced vascular diagnostic equipment that seamlessly integrated with existing imaging and clinical information systems through DICOM connectivity for their vascular clinic. The Unetix Multiab II Roorda is the only known vascular diagnostic system that is fully compactable with the facility s VascuPro network and reporting platform. Procuring this equipment will ensure continuity of operations, maintain interoperability with current infrastructure, and support efficient delivery of patient care without the need for costly system modification or workflow disruptions at 7400 Merton Minter, San Antonio, Tx 78229. If this is an item your business can provide, please respond to this Sources Sought Notice by 11:00 AM Central Time on Thursday, 19 November 2026. The intent of this notice is to establish sources to define the procurement strategy (e.g. set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon. Interested contractors are requested to respond in accordance with the following: a. where is the item manufactured, the VA is interested in procuring items manufactured in the United States. If you have an existing GSA or VA, Federal Supply Schedule contract, include the contract details in your response. Please note that VA is particularly interested in determining the availability of Service Disable Veteran Owned Small Business/Veteran Owned Small Business or other Small Business manufacturers or authorized distributors that can provide this item. Respond to this notice if you can provide these products listed in the table in the background and requirement section above. In response, please cite your business size status. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept gray market items. Vendors are requested to submit estimated market research pricing with their responses. The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g. if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside). Responses should include: (1) Business Name (2) Business Address (3) Point of Contact - Name - Phone Number - E-mail Address (4) SAM UID Number (5) NAICS code (6) Business Size: SMALL or LARGE (7) Type of Business: SERVICE-DISABLED VETERAN OWNED (SDVOSB), VETERAN OWNED(VOSB), 8A, HUBZone, WOMAN-OWNED (WOSB), etc. (8) Letter stating OEM authorized dealer, authorized distributor, or authorized reseller for the proposed equipment and/or services if applicable (9) GSA/FSS Contract Number if applicable All businesses eligible to provide this item are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement. Send responses to Michelle Cunningham at michelle.cunningham@va.gov. DISCLAIMER: THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, Contractors may submit a capability statement, proposal, or quotation which shall be considered by the contracting officer whether to continue with the sole source procurement or to provide for competition. Due to technical issues, please allow additional time if you re using electronic means. Responses received will be evaluated; however, a determination by the Government not to compete the proposed procurement based upon responses received to this notice is solely within the discretion of the Government. | - | Market Research | 11/19/2026 |
Good day, SDVOSB s, VOSB s & SB's Sources Sought INTENT TO SOLE SOURCE Pre-Solicitation. This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs VOSBs , or SBs . This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks. 1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744 is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer. 2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care. 2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays. 3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment. 4.Period of Performance: The product is requested to be delivered no later than December 19th. 5.Type of Contract: Supply: Firm, Fixed Price. 6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below. 6.1 Salient Characteristics NAME BRAND - Equipment Requirement: GE Healthcare QTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer QTY. 6 (P/N: UA2511) Reprocessing Trays for E14C4T Equipment Requirement: Minimum Required Features and Specifications Type / Intended Use: Must be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications. Must provide multi-plane (triplane) imaging capability allowing visualization of transverse, sagittal, and end-fire planes without changing probes. Frequency & Imaging Performance: Must operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate. Must support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system). Biopsy and Procedural Capability: Must include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange. Must accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments. Must permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures. 4. Design & Ergonomics Must be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use. Must include a control ( Smart ) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle. Must be designed for one-handed operation and compatible with sterile probe covers. 5. Compatibility Must be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms. Must connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters. 6. Cleaning & Sterilization Must be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes. Must be compatible with approved sterile covers and disinfection solutions specified in the manufacturer s reprocessing guide. 7. Construction & Safety Must be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards). Must comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits. Must be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use. Summary Table Feature Category Requirement Type Triplane transrectal prostate ultrasound transducer Frequency 4 14 MHz Imaging Modes B, M, Color Doppler, Power Doppler (Elastography optional) Biopsy Capability Integrated dual-plane biopsy guide Needle Compatibility 17 18 G Operation One-handed, Smart Button on probe Sterilization Fully immersible, high-level disinfectable Compatibility bk3000, bk5000, bkActiv, bkSpecto Intended Use Prostate imaging and biopsy guidance Condition New OEM product, OEM warranty | - | Market Research | 11/16/2026 |
Additional Details
Solicitation Number
36C25526Q0502
Archive Date
Jul 27, 2026
Office Address