GovChime
Notice ID: e83ec17a426a4debaa173df608b516d4Sources Sought

6530--Custom Pharmacy cabinetry ScriptPro automation system

Archived on January 3, 2021. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
8:00 AM UTC−06:00
Posted
October 30, 2020
Notice type
Sources Sought
NAICS
337127: Institutional Furniture Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
256-NETWORK CONTRACT OFFICE 16 (36C256)
Place of performance
Department of Veterans Affairs G.V. Sonny Montgomery VA Medical Center 1500 E. Woodrow wilson Drive, Jackson, MS, 39216
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C25621Q0134
Notice ID
e83ec17a426a4debaa173df608b516d4

Description

Page 2 of 2 DEPARTMENT OF VETERANS AFFAIRS VETERANS INTEGRATED SERVICE NETWORK (VISN) 16 G.V. SONNY MONTGOMERY VETERANS HEALTHCARE SYSTEM REQUEST FOR INFORMATION 36C25621Q0134 REQUESTED RESPONSES: The intent of this Request for Information is to establish sources in order to define the procurement strategy. Interested contractors are requested to respond in accordance with the following Please respond to this RFI if you are capable of providing the brand name or equivalent products listed in the SOW found in the background section below. In the response please cite business size status. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: 1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and DUNS Number. 2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing these types of supplies. Please include the following: (a) examples of prior completed Government contracts, references, and other related information. CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to William.Shaver@va.gov. Please respond to this RFI no later than 08:00 Central Standard Time on Wednesday, November 4, 2020. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI. BACKGROUND: (also provided as an attachment see: Attachment Background Section) Pharmacy Renovation Project Check In Area G.V. (Sonny) Montgomery VAMC Jackson, Mississippi Project: Pharmacy Renovation Project Issue Date: Oct 2020 Total Quantity: 1 Finish Sample Required if Checked Manufacturer Certified Installation Required if Checked Item Name: Check In Windows Brand Name or Equal: Modular Pharmacy Solutions Width: Assorted Depth: Assorted Height: Assorted (Use drawing package to identify dimensions) Salient Characteristics: Pharmacy patient check-in functions as the transaction window station for prescription intake. One window is designed to have 34 high ADA working countertop with casework below providing space to hold equipment and supplies. Casework is designed with the following components: solid surface countertop, under counter printer drawer storage, knee space for 4 workstations to intake orders, and prewired modular hospital grade duplex outlets and data boxes. Above each check in workstation is a Lexan transaction window with a no draft speak thru tube. Lexan is an amorphous engineering thermoplastic with high impact strength and outstanding clarity. Each check in window workstation is separated by a modular wall to provide patient privacy. Check In area to have 3 modular walls 8 feet tall and 80 long. Overall dimensions: SEE DRAWINGS. GENERAL REQUIREMENTS FOR MODULAR MILLWORK All surfaces must be cleanable with hospital grade germicides and bleach solutions without harm to finishes. Cabinets constructed of HPL over a ½ minimal thickness low VOC substrate with all edges sealed with matching edge- band. Cabinet interiors fully HPL or LPL lined with no exposed substrate. Warranty- Limited Lifetime To include minimum of the following specifications: A component-based line of cabinetry and coordinating work tops to be used in labs and pharmacy spaces to supply a built- in look while maintaining the quality and flexibility of a modular approach. A wide variety of fully modular cabinet components available for upper and lower storage. Drawer construction options of standard box type with replaceable drawer front and unitary interior box for use in healthcare. Full extension steel ball bearing drawer glides. Work top surface uses Solid Surface material. ADDITIONAL REQUIREMENTS ARE AS FOLLOWS: Materials: *Core material shall be particle board conforming to CS 236-66 45 pound, B density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32 or 1/16 thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces. *Adhesive for laminate shall be urea-formaldehyde resin free. *Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4 wide and flush with worksurface. *Shelving shall be 3/4" thick core with laminate on both sides. *Casework shall be fabricated using flush construction methods with modern machinery. *Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable Features: *Unit shall be free standing with ability to anchor to floor or walls. *Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick. Drawers: *Drawer module inserts shall be individual modular units that are completely removable and relocatable without being disassembled. *Drawer suspension shall have full extension travel, full steel ball bearings of carbonized steel and a positive stop and lock-in closed position (self-closing drawer slides). *Doors and drawer fronts shall be a minimum of 13/16" thick with composed out of the same material as the cabinetry finished with high pressure laminate. Worksurfaces: *Countertop shall run the length of the end panels and be composed out of a solid surface material. Core shall be 1- 1/8" thick with 1/16" laminate finish. *Backsplash and returns shall be provided where shown on drawings. *All exposed edges shall be radiused ¼ . Electrical: *Units are prewired with electrical from the factory and support the data as required. All modular casework should be field verified prior to purchase/installation. Building contractor to pull wiring. Either construction or activation contractor to have licensed electrician make the connections from building to modular casework. *Electrical fixtures shall be Hospital Grade 20 amps, 120 volt, 3-wire polarized grounded duplex receptacles. *Grommet holes to be drilled on site after installation of equipment for proper coordination. Quality Assurance: *Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program. *All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation. *A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required Finishes: *Countertop- Solid surface (Insert manufacturer/color). *Casing, shelves, end panels- Laminate (Insert manufacturer/color), with PVC edge banding to match laminate. Final finishes to be approved by X. GENERAL REQUIREMENTS FOR LEXAN TRANSACTION WINDOW WITH SPEAK TUBE The transaction window shall be Lexan (PC) Polycarbonate, non-opening, and the entire window frame shall be painted in accordance with AAMA Specification 603.8 with 6 clearance at the bottom. Lexan (PC) Polycarbonate is in compliance with stringent FDA and USP requirements. No draft speak thru tube shall be satin anodized aluminum 5-5/16 diameter. GENERAL REQUIREMENTS FOR MODULAR WALL AT CHECK IN WINDOWS Free standing wall panel 8 feet tall with polystyrene core. Vinyl covered gypsum board both sides of wall 3 thick composite sandwich panels, with outside and inside to be ½ class A fire-shield gypsum board with a vinyl finish Core shall be one pound density polystyrene laminated with a structural adhesive. The core shall have the following mechanical properties: shear strength(flatwise) 18-22 PSI; shear modulus (flatwise) 280-320 PSI; water absorption rate shall be less and 4%; and STC value 32 Insulated to a minimum of R-11 Every 4 will have an aluminum extruded post with snap cover to house all the electrical components All posts and window trim painted to match the wall covering 3 x3 steel tubes for support no baseplates Polystyrene Core shall have the following mechanical properties: Shear strength (flatwise) 18 -22 PSI Shear Modulus (flatwise) 280 - 320 PSI The water absorption rate shall be less than 4% STC Value Pharmacy Renovation Project Prescription Pick Up Area G.V. (Sonny) Montgomery VAMC Jackson, Mississippi Project: Pharmacy Renovation Project Issue Date: Oct 2020 Total Quantity: 1 Finish Sample Required if Checked Manufacturer Certified Installation Required if Checked Item Name: Prescription Pick Up Area Brand Name or Equal: Modular Pharmacy Solutions Width: Assorted Depth: Assorted Height: Assorted (Use drawing package to identify dimensions) Salient Characteristics: Pharmacy storage units and workstations at the Pick Up Area support the dispensing functions of the filled prescriptions to patients. Unit is designed to have working countertop with cabinetry below providing storage and space to hold equipment and supplies. Unit is designed with the following components: solid surface countertop, under counter storage and prewired modular hospital grade duplex outlets and data boxes. Solid Surface CTR top. On the Lobby side of the Prescription Pick Up Area, modular walls with a Lexan viewing window are used to create a private area for patient interaction and discussion at the dispensing window. Custom modular wall sizes and configuration are used to maximize privacy. Overall dimensions: SEE DRAWINGS. GENERAL REQUIREMENTS FOR MODULAR MILLWORK All surfaces must be cleanable with hospital grade germicides and bleach solutions without harm to finishes. Cabinets constructed of HPL over a ½ minimal thickness low VOC substrate with all edges sealed with matching edge- band. Cabinet interiors fully HPL or LPL lined with no exposed substrate. Warranty- Limited Lifetime To include minimum of the following specifications: A component-based line of cabinetry and coordinating work tops to be used in labs and pharmacy spaces to supply a built- in look while maintaining the quality and flexibility of a modular approach. A wide variety of fully modular cabinet components available for upper and lower storage. Drawer construction options of standard box type with replaceable drawer front and unitary interior box for use in healthcare. Work top surface uses Solid Surface material. Adjustable 4-way hinges. Adjustable height shelving, HPL surface on all sides of shelves and shelving unit ADDITIONAL REQUIREMENTS ARE AS FOLLOWS: Materials: *Core material shall be particle board conforming to CS 236-66 45 pound, B density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32 or 1/16 thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces. *Adhesive for laminate shall be urea-formaldehyde resin free. *Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4 wide and flush with worksurface. *Shelving shall be 3/4" thick core with laminate on both sides. *Casework shall be fabricated using flush construction methods with modern machinery. *Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable Features: *Unit shall be free standing with ability to anchor to floor or walls. *Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick *Shelving Units shall have 7 adjustable shelves. Worksurfaces: *Countertop shall run the length of the end panels and be composed out of a solid surface material. Core shall be 1- 1/8" thick with 1/16" laminate finish. *Backsplash and returns shall be provided where shown on drawings. *All exposed edges shall be radiused ¼ . Shelves: *All shelves shall be 3/4 thick core with high pressure laminate on both sides. *All shelves adjustable vertically on 1" centers. *All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface Electrical: *Units are prewired with electrical from the factory and support the data as required. All modular casework should be field verified prior to purchase/installation. Building contractor to pull wiring. Either construction or activation contractor to have licensed electrician make the connections from building to modular casework. *Electrical fixtures shall be Hospital Grade 20 amps, 120 volt, 3-wire polarized grounded duplex receptacles. *Grommet holes to be drilled on site after installation of equipment for proper coordination. Quality Assurance: *Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program. *All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation. *A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required Finishes: *Countertop- Solid surface (Insert manufacturer/color). *Casing, shelves, end panels- Laminate (Insert manufacturer/color), with PVC edge banding to match laminate. Final finishes to be approved by X. GENERAL REQUIREMENTS FOR MODULAR WALL AT PICK UP WINDOWS Free standing wall panel 8 feet tall with polystyrene core. Picture windows will be glazed with ¼ LEXAN and shall be an integral part of the wall panel. The window shall be non-opening, and the entire window frame shall be painted in accordance with AAMA Specification 603.8. Vinyl covered gypsum board both sides of wall 3 thick composite sandwich panels, with outside and inside to be ½ class A fire-shield gypsum board with a vinyl finish Core shall be one pound density polystyrene laminated with a structural adhesive. The core shall have the following mechanical properties: shear strength(flatwise) 18-22 PSI; shear modulus (flatwise) 280-320 PSI; water absorption rate shall be less and 4%; and STC value 32 Insulated to a minimum of R-11 Every 4 will have an aluminum extruded post with snap cover to house all the electrical components All posts and window trim painted to match the wall covering 3 x3 steel tubes for support no baseplates Polystyrene Core shall have the following mechanical properties: Shear strength (flatwise) 18 -22 PSI Shear Modulus (flatwise) 280 - 320 PSI The water absorption rate shall be less than 4% STC Value Picture windows will be glazed with ¼ LEXAN and shall be an integral part of the wall panel. The window shall be non-opening, and the entire window frame shall be painted in accordance with AAMA Specification 603.8. Pharmacy Renovation Project RX Fill and Check Area G.V. (Sonny) Montgomery VAMC Jackson, Mississippi Project: Pharmacy Renovation Project Issue Date: Oct 2020 Total Quantity: 1 Finish Sample Required if Checked Manufacturer Certified Installation Required if Checked Item Name: RX Fill and Check Island Brand Name or Equal: Modular Pharmacy Solutions Width: Assorted Depth: Assorted Height: Assorted (Use drawing package to identify dimensions) Salient Characteristics: Pharmacy storage and standing height workstation to function as the pharmacy check and fill operations. Unit is designed to have a working countertop with cabinetry below and above providing storage and space to hold equipment and supplies. Unit is a free standing, two-sided island with pass thru opening to receive orders from the other side with above the counter mounted shelving, continuous countertop and lower storage with finished end panels. Unit is designed with the following components: Secured suspended upper-case support system with adjustable shelving, 24" wide task lighting, solid surface countertop, open under counter storage, pull out printer shelves, knee space with back panel, open adjustable shelving, gravity drawers and modular hospital grade duplex receptacles and data boxes integrated. Power entry from overhead junction box; coordinate with building MEP. Side 1 (Pharmacy Fill): (4) 24" wide Gravity sloped drawers with dividers, set up for 4 workstations, (1) 24" wide printer pull out shelves to house automation printers, (8) 34-1/4" wide shelf sloping overhead storage with task lighting and pass thru (maintain 20" clear between bottom of task light and top of worksurface), (4) 24-3/8" under counter shelf storage units and (4) open units to hold waste bin. Side 2 (Pharmacy Check): (8) 34-1/4" wide shelf sloping overhead storage with task lighting and pass thru (maintain 20" clear between bottom of task light and top of worksurface), set up for 4 workstations with (4) 45-3/8 wide knee space and (4) printer drawers 24 wide. Solid Surface CTR top. GENERAL REQUIREMENTS FOR MODULAR MILLWORK All surfaces must be cleanable with hospital grade germicides and bleach solutions without harm to finishes. Cabinets constructed of HPL over a ½ minimal thickness low VOC substrate with all edges sealed with matching edge- band. Cabinet interiors fully HPL or LPL lined with no exposed substrate. Warranty- Limited Lifetime To include minimum of the following specifications: A component-based line of cabinetry and coordinating work tops to be used in labs and pharmacy spaces to supply a built- in look while maintaining the quality and flexibility of a modular approach. A wide variety of fully modular cabinet components available for upper and lower storage. Drawer construction options of standard box type with replaceable drawer front and unitary interior box for use in healthcare. Full extension steel ball bearing drawer glides. Work top surface uses Solid Surface material. Adjustable height shelving, HPL surface on all sides of shelves and shelving unit ADDITIONAL REQUIREMENTS ARE AS FOLLOWS: Materials: *Core material shall be particle board conforming to CS 236-66 45 pound, B density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32 or 1/16 thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces. *Adhesive for laminate shall be urea-formaldehyde resin free. *Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4 wide and flush with worksurface. *Shelving shall be 3/4" thick core with laminate on both sides. *Casework shall be fabricated using flush construction methods with modern machinery. *Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable Features: *Unit shall be free standing with ability to anchor to floor or walls. *Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick. *Steel supports/back panels: shall be capable to support up to 600 pounds. Finish shall be powder coated paint that shall be coordinated with laminate finish. They should include slant brackets at 2 intervals, a retainer clip and shall allow for the adjustment of shelves on steel pins. Back panels shall be removable and able to incorporate electrical duplex boxes. Drawers: *Drawer module inserts shall be individual modular units that are completely removable and relocatable without being disassembled. *Drawer suspension shall have full extension travel, full steel ball bearings of carbonized steel and a positive stop and lock-in closed position (self-closing drawer slides). *Doors and drawer fronts shall be a minimum of 13/16" thick with composed out of the same material as the cabinetry finished with high pressure laminate. Worksurfaces: *Countertop shall run the length of the end panels and be composed out of a solid surface material. Core shall be 1- 1/8" thick with 1/16" laminate finish. *Backsplash and returns shall be provided where shown on drawings. *All exposed edges shall be radiused ¼ . Shelves: *All shelves shall be 3/4 thick core with high pressure laminate on both sides. *All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down. *All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use. *All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface. Electrical: *Units are prewired with electrical from the factory and support the data as required. All modular casework should be field verified prior to purchase/installation. Building contractor to pull wiring. Either construction or activation contractor to have licensed electrician make the connections from building to modular casework. *Electrical fixtures shall be Hospital Grade 20 amps, 120 volt, 3-wire polarized grounded duplex receptacles. *Grommet holes to be drilled on site after installation of equipment for proper coordination. Quality Assurance: *Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program. *All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation. *A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required Finishes: *Countertop- Solid surface (Insert manufacturer/color). *Casing, shelves, end panels- Laminate (Insert manufacturer/color), with PVC edge banding to match laminate. Final finishes to be approved by X. Pharmacy Renovation Project Automation Support Area G.V. (Sonny) Montgomery VAMC Jackson, Mississippi Project: Pharmacy Renovation Project Issue Date: Oct 2020 Total Quantity: 1 Finish Sample Required if Checked Manufacturer Certified Installation Required if Checked Item Name: Automation Replenishment and Vial Storage, Narcotic Workstation Brand Name or Equal: Modular Pharmacy Solutions Width: Assorted Depth: Assorted Height: Assorted (Use drawing package to identify dimensions) Salient Characteristics: Pharmacy storage shelves used to store pharmaceutical drugs, containers and other supplies needed to support and replenish the automation. High volume gravity-fed vial storage unit designed for easy access to vials during the filling process. Unit is designed with gravity fed compartment with plexiglass front to see when vial supply is low and a separate built in area for caps. Narcotic workstation and storage for filling schedule 2-5 drugs. Unit is designed with the following components: adjustable flat or sloping shelves above counter, solid surface countertop, under counter printer drawer storage, gravity drawers and prewired modular hospital grade duplex outlets and data boxes. Overall dimensions: SEE DRAWINGS. GENERAL REQUIREMENTS FOR MODULAR MILLWORK All surfaces must be cleanable with hospital grade germicides and bleach solutions without harm to finishes. Cabinets constructed of HPL over a ½ minimal thickness low VOC substrate with all edges sealed with matching edge- band. Cabinet interiors fully HPL or LPL lined with no exposed substrate. Warranty- Limited Lifetime To include minimum of the following specifications: A component-based line of cabinetry and coordinating work tops to be used in labs and pharmacy spaces to supply a built- in look while maintaining the quality and flexibility of a modular approach. A wide variety of fully modular cabinet components available for upper and lower storage. Drawer construction options of standard box type with replaceable drawer front and unitary interior box for use in healthcare. Full extension steel ball bearing drawer glides. Work top surface uses Solid Surface material. Adjustable height shelving, HPL surface on all sides of shelves and shelving unit ADDITIONAL REQUIREMENTS ARE AS FOLLOWS: Materials: *Core material shall be particle board conforming to CS 236-66 45 pound, B density, Class 1 of Type 1 *Laminated plastic for general construction shall be 1/32 or 1/16 thick high-pressure type *All top, side and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finish as selected for exposed surfaces. *Adhesive for laminate shall be urea-formaldehyde resin free. *Edge moldings shall be PVC edge band and appear on all edges of the casework that are visibly exposed. Molding shall be the same thickness as shelf when on shelf, counter molding shall be 1-1/4 wide and flush with worksurface. *Shelving shall be 3/4" thick core with laminate on both sides. *Casework shall be fabricated using flush construction methods with modern machinery. *Casework shall be delivered fully constructed and ready for installation. Each unit shall be self-supporting and permit relocation. The sharing of component parts to form a rigid, modular, free-standing assembly shall not be acceptable Features: *Unit shall be free standing with ability to anchor to floor or walls. *Unit shall have a non-adjustable bottom shelf that is the base of the cabinet positioned on top of the toe kick *Unit shall have a 4" toe kick. *Shelving Units shall have 7 adjustable shelves. *Steel supports/back panels: shall be capable to support up to 600 pounds. Finish shall be powder coated paint that shall be coordinated with laminate finish. They should include slant brackets at 2 intervals, a retainer clip and shall allow for the adjustment of shelves on steel pins. Back panels shall be removable and able to incorporate electrical duplex boxes. Drawers: *Drawer module inserts shall be individual modular units that are completely removable and relocatable without being disassembled. *Drawer suspension shall have full extension travel, full steel ball bearings of carbonized steel and a positive stop and lock-in closed position (self-closing drawer slides). *Doors and drawer fronts shall be a minimum of 13/16" thick with composed out of the same material as the cabinetry finished with high pressure laminate. Worksurfaces: *Countertop shall run the length of the end panels and be composed out of a solid surface material. Core shall be 1- 1/8" thick with 1/16" laminate finish. *Backsplash and returns shall be provided where shown on drawings. *All exposed edges shall be radiused ¼ . Shelves: *All shelves shall be 3/4 thick core with high pressure laminate on both sides. *All shelves noted as being sloping shall also adjust to a flat position. Adjustable vertically on 1" centers and from horizontal to 15, 30, and 45-degree slope down. *All shelves shall be completely reversible with retainer lips being turned up, down, or to the back as required for use. *All top, side, and bottom panels and shelf panels shall be laminated with high pressure laminate including cabinet interiors in the same color and finishes as selected for the exposed surfaces. All cabinet backs will have HPL on interior surface. Electrical: *Units are prewired with electrical from the factory and support the data as required. All modular casework should be field verified prior to purchase/installation. Building contractor to pull wiring. Either construction or activation contractor to have licensed electrician make the connections from building to modular casework. *Electrical fixtures shall be Hospital Grade 20 amps, 120 volt, 3-wire polarized grounded duplex receptacles. *Grommet holes to be drilled on site after installation of equipment for proper coordination. Quality Assurance: *Manufacturer must have a minimum of 5 years experience in providing manufactured casework for similar types of projects. Manufacturer facility must be certified to premium grade by the AWI Quality Certification Program. *All pharmacy casework included in this specification shall be made by a pharmacy casework manufacturer who is a specialist in the design and manufacture of pharmacy casework and has in operation, a factory adequate in size, with facilities for and devoted to the manufacture of the equipment he or his distributor proposes to supply. This requirement is stated for the Owners protection to eliminate any divided responsibility and to ensure that all completed assemblies shall be in harmony and uniform in design, color, type of hardware, etc., for the completed facility/installation. *A minimum of five years experience in the design, sale, manufacture, shipping, and installation of the quality and type of pharmacy casework specified herein shall be required Finishes: *Countertop- Solid surface (Insert manufacturer/color). *Casing, shelves, end panels- Laminate (Insert manufacturer/color), with PVC edge banding to match laminate. Final finishes to be approved by X. Pharmacy Custom Cabinetry/Pharmacy Casework Salient Characteristics Materials: Core material shall be particle board conforming to CS 236-66 45 pound B density Class 1 Type 1 Laminated plastic for general construction shall be 1/32 or 1/16 thick high-pressure type All top, side and bottom panels and shelf panels shall be laminated with high pressure lami...

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C25621Q0134
  1. Market Research

Pre-solicitation or formal solicitation typically follows within 30–180 days. (estimate)

  1. Market ResearchCurrentOct 30, 2020

    6530--Custom Pharmacy cabinetry ScriptPro automation system

    Notice e83ec17a426a4debaa173df608b516d4 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
52%
AwardedOpen
Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 6 DESCRIPTION 1.0 DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Environmental Disinfection Systems Pulsed Xenon UV Light. The EPO in conjunction with VHA is seeking qualified sources capable of supplying the Xenex LightStrike+ Environmental Disinfection Systems Pulsed Xenon UV Light or equivalent products that satisfy the minimum technical requirements, on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete Xenex LightStrike+ Environmental Disinfection Systems Pulsed Xenon UV Light to VA medical centers and facilities throughout the United States. The associated North American Industry Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. The FAR Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation. You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All Service Disabled Veteran Owned Small Business (SDVOSB) / Veteran Owned Small Business (VOSB) respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission. Submissions for this Sources Sought Notice shall be submitted by email no later than November 4, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses: Alanna.Wilson@va.gov Anthony.Zibolski@va.gov Email responses shall include the following subject line: Response to Sources Sought Notice 36C10X27Q0009. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time. 2.0 SCOPE OF WORK The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Environmental Disinfection Systems Pulsed Xenon UV Light as a candidate for a VA-wide (otherwise referred to as national ) contract. Systems that use ultraviolet (UV) light designed to kill, remove, or render inert pathogenic microorganisms present in a closed environment and on hard inanimate surfaces and objects located in that environment (frequently limited to one room). These systems are intended to remove microorganisms from the environment (i.e., most viruses and bacteria, including mycobacteria) and other microbial forms, including spores when using appropriate wavelengths in the UV spectrum. The UV radiation is obtained from dedicated (e.g., low-pressure mercury, pulsed-xenon) lamps that emit radiation in the UV-B and C ranges (e.g., from 200 to 320 nm wavelength); a fixed wavelength of 254 nm is frequently used. The systems are usually automated and include computerized and remote monitoring capabilities. Some systems permit choosing one of several working cycles according to the room disinfection needs. UV environmental disinfection systems are intended for short-term use (e.g., from several minutes to a few hours) in patient rooms, operating rooms, and other healthcare facility closed areas; they are usually used after a terminal cleaning that is performed when a patient is transferred or discharged from a room. The following Contract Line Items (CLINs) are being considered: Contract Line Items Manufacturer Part Number Description 0001 Xenex MXSUV1-FT MXSUV1-FT (Without XCT Program) 0002 Xenex MXSUV1-FTXCT MXSUV1-FT (With XCT Program) 0003 Xenex MXSUV1-SL MXSUV1-SL (Without XCT Program) 0004 Xenex MXSUV1-SLXCT MXSUV1-SLXCT (With XCT Program) 0005 Xenex W W - Optional One Year Warranty Extension Without XCT 0006 Xenex XCTW XCTW - Optional One Year Warranty Extension With XCT Respondents should identify a complete solution including associated accessories, as required for the system s full functionality. The following Minimum Technical Requirements (MTRs) are being considered: FDA Authorized Whole Room Microbial Reduction Devices The contractor shall provide FDA authorized whole room ultraviolet microbial reduction systems. System Architecture Characteristics System shall utilize a high intensity pulsed xenon emitter capable of producing broad spectrum germicidal ultraviolet energy within the 240 315 nm range. System shall operate as a single integrated unit capable of delivering 360-degree germicidal exposure in typical clinical environments. Workflow Characteristics System shall be deployable by a single trained operator. System shall not require staff to reenter the treatment area while cycles are active. System shall support treatment of primary patient care areas as well as adjacent spaces such as restrooms or anterooms through configurable cycle options. Vendor shall provide operator training covering device setup, operation, safety, maintenance, certification, and competency. Technology / Connectivity Characteristics System shall provide a unified operator interface capable of initiating, monitoring, and completing treatment cycles through a single control platform. System shall support cloud-based reporting of cycle completion, operator usage, and device performance analytics. Cloud connectivity features shall function independently of internal facility networks, avoiding reliance on local security credentials or firewalls. Physical / Deployment Characteristics System shall consist of a single mobile unit that can be transported between rooms by one operator. System shall include integrated power management and charging capabilities suitable for frequent deployment within clinical workflows. System shall include durable wheels, handles, and stabilization features appropriate for movement throughout healthcare facilities. System shall be designed for operation in unoccupied clinical rooms, including patient care areas, operating rooms, procedural suites, and utility spaces. For each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the MTRs specified above. The Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessories, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number. Responses to this Sources Sought Notice shall include the following: Full name and address of company. SAM Unique Entity Identifier (UEI). Business Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)). Manufacturer or Distributor: If distributor, provide the full name, business size and address of the manufacturer. If distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM. Country of Origin designation for all products proposed. Describe the firm s ability to provide uninterrupted supply of products on a national scale. Technical literature clearly demonstrating that the proposed product(s) meets the identified minimum technical requirements identifying the page number(s) where each requirement is met within the supporting documentation. Does the respondent offer an annual service plan, Yes or No? If Yes: Describe what the plan covers. Identify whether the plan covers software updates, parts repair/replacement, or both Provide literature or other documentation describing the service plan. Identify whether service is provided by the OEM or a subcontractor. Identify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the proposed solution. Include the applicable brand name and part number. Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any. NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide estimated pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns. Does your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted. Identify any federal contract vehicles held by your firm through which your firm can provide this equipment. Are there any further standards or criteria VA should consider in a procurement action for this equipment? Are the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language. Any additional information the Government should know prior to issuing a solicitation. Describe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis.
44%
Market Research11/04/2026
Good day, SDVOSB s, VOSB s & SB's Sources Sought FSS Pre-Solicitation. This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs VOSBs , or SBs . This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete. Any drawings or other interior information will be provided once this becomes a solicitation, there will be no drawings, or product information provided for this sources sought. Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks. GENERAL: The C.W. Bill Young Veterans Medical Center (VA Bay Pines Health System) located at 10000 Bay Pines Blvd. Bay Pines, FL. 33744, has to update, expand, and install previously procured interior and exterior signage in conjunction with the Building 1 renovation. The solution must be brand name only and function and match finishes and sizes exactly that are currently VA approved, designed, and installed; therefore, continuing to provide the VA patients with a consistent, interchangeable, and unfailing signage system. This is a GSA FSS Schedule MAS 339950 procurement for architectural signage and ancillary services including programming, design, and installation. SCOPE: This project is a logical follow-on to a previously awarded contract for the VA Bay Pines Health Care System. Under the prior procurement, the VA awarded a contract to plan, program, manufacture, and install the approved brand name sign standard for portions of Building 1 associated with a major construction project. Due to delays in the construction schedule, the Government reduced the scope of that project and purchased only the base signage without installation. Construction is now moving forward, and the renovated areas will soon be ready for occupancy. This new procurement enables the Government to: Update and adjust the brand name signage previously purchased but never installed in Building 1 due to construction delays;
43%
Market Research11/16/2026
40%
AwardedOpen
40%
AwardedOpen

Additional Details

Solicitation Number

36C25621Q0134

Archive Date

Jan 3, 2021

Office Address

RIDGELAND, MS, 39157