GovChime
Notice ID: d4a9d2dc23c449e389c57a3eecb8de07Award NoticeAwarded

C1NB--AE | 586-22-103 | Renovate Chilled Water and Steam Distribution Systems

Awarded on June 23, 2023. Full description on SAM.gov.

Awarded tounder 36C25623C0055 (source: SAM.gov award notice)• $3.2M

Overview

Posted
June 26, 2023
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)

Notice details

Place of performance
Department of Veterans Affairs G.V. Sonny Montgomery VA Medical Center 1500 East Woodrow Wilson Avenue, Jackson, 39216
Last updated
Dec 4, 2025
Award date
Jun 23, 2023
Award amount (SAM.gov award notice)
$3.2M

Identifiers

Solicitation number
36C25622R0150
Notice ID
d4a9d2dc23c449e389c57a3eecb8de07
Award number (PIID)
36C25623C0055

Description

AE | 36C25622R0150 | 586-22-103 | Repair Chilled Water and Steam Distribution Systems The revised Statement Of Work (revisions are highlighted yellow) contains answers to some of the questions received regarding the original Combined Synopsis/Solicitation Notice. Questions that were not answered by the revisions are addressed below: Page 6 paragraph D. The SOW states, The selected A/E shall have a Mississippi-licensed Mechanical Engineer/Project Manager that is permanently located (based) within 25 miles of the Jackson VA Medical Center. This Mississippi-based/licensed Mechanical Engineer/Project Manager shall be contracted by and support the selected A/E for the duration of the design and construction phases of the project. Question: We typically utilize personnel who have a past performance demonstrating knowledge of location and geographical conditions. Given the 25-mile restriction will you provide the name of the engineer(s) and/or specific firm(s) you would like us to use or waive the requirement and trust that we will provide the most qualified personnel and/or subconsultants in our submission? Answer: See page 6 paragraph D in revised SOW. Page 7 paragraph F. A 3rd party licensed Fire Protection Engineer shall be obtained by A/E for documented review of all contract documents. Results to be provided to VA for review and approval. Question: We self-perform Fire Protection Services and include those services during pre-design, design development and construction phase services. Request you waive the 3rd party requirement as we are already contractually responsible for all reviews provided by 3rd parties. It would be more efficient and less costly if we were to self-perform those services. Answer: The government believes that a 3rd party review from a fire protection engineer reporting directly to the VA would be much more objective in the review comments. Page 6 paragraph F. The A/E shall provide complete, 3rd party, (Association of Energy Engineers) AEE-accredited Certified Building Commissioning Professional (CBCP) mechanical system design and construction energy commissioning (Cx) services. Question: We self-perform Commissioning Services and include those services during pre-design, design development and construction phase services as required. Request you waive the 3rd party requirement as we are already contractually responsible for all reviews provided by 3rd parties. It would be more efficient and less costly if we were to self-perform those services. Answer: Our standard operating procedure here in Jackson is to have the A/E provide a separate 3rd party commissioning agent for all projects. Page 8 Time Schedule, Review, and Submittal Requirements. Question: The 25% design submittal is 120 days after award of contract including 60 days of investigation. 60 days of investigation may not leave sufficient time for design development if there are any investigated items requiring major collaboration with VA Stake Holders on scope review and subsequent conceptual development. Please confirm the entire schedule, review and submittal requirements. Answer: We have reviewed our project schedule and the intent with the tight front end investigation effort was to make sure we end up with an A/E that truly has the mechanical engineering capacity and experience to do the project. If it is extended, we could end up with a understaffed firm that tries to fit the schedule. Also, the first 120 days in our POP is for the investigation of existing facilities and get the 25% drawings prepared that show the existing that the design will be based on. Section D, it states the selected A/E shall have a Mississippi-licensed Mechanical Engineer/Project Manager that is permanently located (based) within 25 miles of the Jackson VA Medical Center. Question: However, we could not find any such restrictions in the solicitation. Can you please confirm whether or not the selected A/E does need to be registered in Mississippi and located within 25 miles of the Jackson VA Medical Center? Answer: See page 6 paragraph D in revised SOW.

Full description on SAM.gov

Award Overview

Award Number

36C25623C0055

Award Amount (SAM.gov award notice)

$3.2M

Award Date

Jun 23, 2023

Awardee

Awardee UEI

TQ5MWGSBSF75

Awardee CAGE Code

5SCG8

Original Solicitation

Notice ID: d4a9d2dc23c449e389c57a3eecb8de07

Posted Date: Jun 26, 2023

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C77626N0049
    DAV ENERGY SOLUTIONS, INC.
    Department of Veterans AffairsNAICS 541330
    $796.3KSigned Nov 10, 2026
  • 36C25025C0029
    DAV ENERGY SOLUTIONS, INC.
    Department of Veterans AffairsNAICS 541330
    $236.7KSigned Nov 5, 2026
  • 36C26127N0132
    DAV ENERGY SOLUTIONS, INC.
    Department of Veterans AffairsNAICS 541330
    $536.6KSigned Nov 5, 2026
  • 36C77626N0049
    DAV ENERGY SOLUTIONS, INC.
    Department of Veterans AffairsNAICS 541330
    $796.3KSigned Nov 4, 2026
  • 36C26024C0070
    DAV ENERGY SOLUTIONS, INC.
    Department of Veterans AffairsNAICS 541330
    $390.2KSigned Oct 30, 2026

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C25622R0150
  1. Combined Synopsis
  2. Awarded

This opportunity has been awarded.

  1. 5×
    Combined SynopsisOct 14, 2022

    C1NB--AE | 586-22-103 | Repair Chilled Water and Steam Distribution System

    Notice 3ea62ecec3254a9480e93e7d134c9a19 on SAM.gov

  2. AwardedCurrentJun 26, 2023

    C1NB--AE | 586-22-103 | Renovate Chilled Water and Steam Distribution Systems

    Notice d4a9d2dc23c449e389c57a3eecb8de07 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

36C25622R0150

Archive Date

Jul 11, 2023

Office Address

RIDGELAND, MS, 39157