Notice ID: 12b9142e093649348c110d1d2cfbad82Combined Synopsis/Solicitation
W065--Mobile MRI in Springfield MO
Archived on September 29, 2024. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 10:00 AM UTC−05:00
- Posted
- July 18, 2024
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 621512: Diagnostic Imaging Centers
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 256-NETWORK CONTRACT OFFICE 16 (36C256)
- Place of performance
- Department of Veterans Affairs VETERANS HEALTHCARE SYSTEM OF THE OZARKS GENE TAYLOR CBOC 1800 SPRINGFIELD STREET, Springfiled, 65807
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C25624Q0713
- Notice ID
- 12b9142e093649348c110d1d2cfbad82
Description
5. PROJECT NUMBER (if applicable) CODE 7. ADMINISTERED BY 2. AMENDMENT/MODIFICATION NUMBER CODE 6. ISSUED BY 8. NAME AND ADDRESS OF CONTRACTOR 4. REQUISITION/PURCHASE REQ. NUMBER 3. EFFECTIVE DATE 9A. AMENDMENT OF SOLICITATION NUMBER 9B. DATED PAGE OF PAGES 10A. MODIFICATION OF CONTRACT/ORDER NUMBER 10B. DATED BPA NO. 1. CONTRACT ID CODE FACILITY CODE CODE Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers E. IMPORTANT: is extended, (a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended. 12. ACCOUNTING AND APPROPRIATION DATA (REV. 11/2016) is required to sign this document and return ___________ copies to the issuing office. is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A. 15C. DATE SIGNED B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b). RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified. C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF: D. OTHER Contractor 16C. DATE SIGNED 14. DESCRIPTION OF AMENDMENT/MODIFICATION 16B. UNITED STATES OF AMERICA Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect. 15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER 15B. CONTRACTOR/OFFEROR STANDARD FORM 30 PREVIOUS EDITION NOT USABLE Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.) (Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.) (If required) (SEE ITEM 11) (SEE ITEM 13) (X) CHECK ONE 13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS, IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14. 11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT (Signature of person authorized to sign) (Signature of Contracting Officer) 1 10 0001 07-18-2024 00256 Department of Veterans Affairs G.V. (Sonny) Montgomery VAMC Network Contracting Office 16 715 South Pear Orchard Road Ridgeland MS 39157 10N16 Department of Veterans Affairs G.V. (Sonny) Montgomery VAMC A&MM Service (90C) 715 South Pear Orchard Road Ridgeland MS 39157 To all Offerors/Bidders 36C25624Q0713 X X X 1 July 31, 2024 at 10:00 am CST The purpose of this amendment is as follows: 1. Extend the response due date. 2. Replacing the Statement of Work and Price Schedule with the attached Statement of Work and Price Schedule. 3. Incorporating FAR Clause 52.232-18 Availability of Funds (APR 1984) into the solicitation. Tammie Chaney Contracting Officer 36C25624Q0713 Page 1 of Page 1 of Page 1 of Page 1 of STATEMENT OF WORK Gene Taylor CBOC Mobile MRI Lease Veterans Health Care System of the Ozarks Springfield, MO PURPOSE The overall purpose is to provide and install a Mobile MRI Trailer and Equipment at Veterans Health Care System of the Ozarks (VHSO), Gene Taylor Community Based Outpatient Clinic, 1800 W. Republic St, Springfield, MO 65807. SCOPE The contractor to provide all equipment, tools, materials, labor, transportation, site construction (to include utility hook-ups (power, data, telephone), equipment training, on-site installation, and anything else necessary to provide for an equipment lease for fully functioning/fully operable 1.5 Tesla (T) Mobile Magnetic Resonance Imaging (MRI) System trailer for the Gene Taylor Community Based Outpatient Clinic (VA) at 1800 W. Republic St, Springfield, MO 65807. The contractor is responsible for transporting the unit to and from the location. The contractor shall be TJC (The Joint Commission) Accredited and/or shall follow established TJC guidelines, as they pertain to the Mobile MRI operations. The Period of Performance will be for a 12-Month Base Period and four (4) 12-Month Option Periods. The contractor must have the capability of providing a mobile MRI unit to be onsite 7 days per week for at least the Base Year with Four Option Years of service. System/equipment shall be fully capable and able to transfer image and data to multiple modalities including VA PACS, VISTA Imaging, printers, and Hospital RIS System (full DICOM Communication). Each location shall have different IP addresses, subnet masks, and VPNs. Communication between MRI and Radiology Services PACS: The Contractor shall ensure that a convenient and robust means of DICOM transfer of MRI studies to the VA Radiology Service PACS is operational. The Contractor shall obtain and provide to the VA any technology necessary to ensure that MRI studies can be conveniently read on the existing VA PACS display technology. Any peripherals that the VA does not have but that is needed to ensure convenient and timely display of MRI studies in the VA Radiology Service shall be obtained by the Contractor, be installed, and be retained by the VA so that at future dates the archived studies can be reviewed. Each MRI study will be transferred to the VA PACS immediately following the acquisition of the study so that it can, if necessary, be reviewed before the patient leaves the MRI Trailer. The Contractor shall have the MRI Trailer and Equipment in-place and fully operational no later than October 1, 2024. The Mobile MRI Equipment shall be equal to or better than the description of a 1.5T Siemens Magnetom Aera. The contractor is responsible for the maintenance of the unit, including all Preventative Maintenance, and all Parts and Labor. All Preventative Maintenance to be performed after normal duty hours. Contractor agrees to cooperate with VA for quality control purposes. Contractor agrees to meet all safety requirements such as posting MRI Hazardous ZONE Signs around the Mobile MRI Trailer. SALIENT CHARACTERISTICS Minimum requirements for this system are a state of the art 1.5T magnet: Must have Tim 4G s integrated coil technology. The MRI must have a minimum 70cm bore for patients that are claustrophobic and/or obese. Gradient strength of 45mT/m@200T/m/s). RF technology should have maximum of at least 204 channels and 24/48/64 independent receiver channels that can be used simultaneous in one single scan and in one single FoV, each generating an independent partial image. Equipment will be capable of sending images to a minimum of 3 destinations (printer, PAC s, VistA, Hospital RIS System, etc) MRI System will include the following application packages at a minimum: Neuro Suite to include diffusion and perfusion imaging Ortho Suite to include customizable workflows and susceptibility artifact reduction functionality. Body Imaging Suite that includes FREEZEit technology to overcome motion and incorrect timing. Software that includes ultra-fast, high-resolution, 2D and 3D protocols. Angio Suite with software to optimize bolus timing, real-time graphics and automatic voice command to assist with ideal timing of breathing, scanning and contrast media. Simultaneous Multi-Slice application Patient experience applications that include lighting, music, video to calm anxious patients. These Coils must be included at a minimum: CP Extremity Coil (knee, ankle, Peripheral MR Angio) Tx/Rx CP Head Coil Body 18 coil Peripheral Angio 36 coil Hand/Wrist 16 Coil Foot/Ankle 16 Coil Flex Large 4 Coil (hip, shoulder, knee) Shoulder Large 16, Shoulder Small 16 coils Flex small 4 coil Body 60/Body 20 Coil Contour Coil 4-Channel Special Purpose Coil (carotids) Loop Coil, small (fingers, toes) Additional MRI Trailer and System Requirements: CD Burner Full compatibility with hospital PACS system DICOM 3.0 Patient intercom system Safety and Warning Systems Visual and Audible Alarms Smoke Detectors, Fire Extinguishers Emergency Lighting Battery Phone and data ports 480v 50 power cable Hydraulic patient lift, Stairs and railings HVAC system to maintain trailer environmental systems Operators and Technical support Manuals Full System Service (Monday Friday after normal duty hours local time excluding Federal Holidays) Regular scheduled maintenance to be performed after hours 24 Hour telephone technical support toll free line, response within 1 hour. 550 LBS maximum patient table weight DELIVERY and INSTALLATION Delivery Contractor shall deliver all equipment to the Veterans Health Care System of the Ozarks (VHSO), Gene Taylor Community Based Outpatient Clinic, 1800 W. Republic St, Springfield, MO 65807. The contractor is responsible for transporting the unit to and from the location. Installation Install all equipment to manufacturer s specifications maintaining Federal, and Local safety standards Installation must be completed by August 1, 2024. All work shall be completed between 8:00 a.m. and 4:30 p.m. Monday Friday. All federal holidays, excluded. If there is an operational conflict with installation, night or weekend installation may be required. Government will provide a 72 hours' notice of change of installation hours. The Contractor shall remove all related shipping debris and cleanup any construction associated with delivery and installation of the specified items. Contractor shall remove all packaging from the SLVHCS premises. The Contractor shall be responsible for any damage to the building that occurs due to Contractor error or neglect. SITE CONDITIONS There shall be no smoking, eating, or drinking inside the hospital at any time. INSPECTION and ACCEPTANCE: Contractor shall provide dates of completion of punch list items and replacement parts and/or short ship items from the manufacturer(s). The COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the Contracting Officer. DELIVERY/STORAGE REQUIREMENTS Deliver materials to job in manufacturer's original sealed containers with brand name marked thereon. Package to prevent damage or deterioration during shipment, handling, storage and installation. Maintain protective covering in place and in good repair until removal is necessary. Deliver specified items only when the site is ready for installation work to proceed. Store products in dry condition inside enclosed facilities. Any government requested delayed delivery up to 90 days after initial negotiated delivery date, shall be at no additional cost to the Government. A pre-delivery meeting will be conducted 60 days prior to initial negotiated delivery date for verification of delivery and installation dates. Delivery and Installation will be coordinated through the COR. DELIVERABLES Operation and Maintenance Manuals Binders - Quantity (2) Digital Copies- Quantity (1) Deliver compilation of all manufacturer recommended maintenance schedule and operation materials packaged in binder(s) to COR upon completion of installation. OPERATOR TRAINING Contractor shall provide On-site training of the equipment to the Users. Scheduling of operator training shall be coordinated with the COR after installation is complete. PROTECTION OF PROPERTY Contractor shall protect all items from damage. The Contractor shall take precaution against damage to the building(s), grounds and furnishings. The Contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor. The Contractor shall perform an inspection of the building(s) and grounds with the COR prior to commencing work. To ensure that the Contractor shall be able to repair or replace any items, components, building(s) or grounds damaged due to negligence and/or actions taken by the Contractor. The source of all repairs beyond simple surface cleaning is the facility construction contractor (or appropriate subcontractor), so that building warranty is maintained. Concurrence from the VA Facilities Management POC and COR is required before the Contractor may perform any significant repair work. In all cases, repairs shall utilize materials of the same quality, size, texture, grade, and color to match adjacent existing work. The Contractor shall be responsible for security of the areas in which the work is being performed prior to completion. Contractor shall provide floor protection while working in all VA facilities. All material handling equipment shall have rubber wheels. SECURITY REQUIREMENTS The C&A requirements do not apply and a Security Accreditation Package is not required. WARRANTY The contractor shall provide a one-year manufacturer s warranty on all parts and labor. The warranty shall include all travel and shipping costs associated with any warranty repair. B.2 PRICE/COST SCHEDULE ITEM INFORMATION ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 1.00 JB __________________ __________________ Contract to provide all equipment, tools, materials, labor, transportation, site construction to include utility hook-up (power, data, telephone, etc.), equipment training, on-site installation, and anything else necessary to provide for an equipment lease for a new fully functioning/fully operable 1.5 Tesla (T) Mobile Magnetic Resonance Imaging (MRI) System trailer for the Gene Taylor Community Based Outpatient Clinic, Springfield, MO. PRINCIPAL NAICS CODE: 621512 - Diagnostic Imaging Centers PRODUCT/SERVICE CODE: W065 - Lease or Rental of Equipment - Medical, Dental, and Veterinary Equipment and Supplies 0002 1.00 JB __________________ __________________ Contract to provide all equipment, tools, materials, labor, transportation, site construction to include disconnection of utility hook-up (power, data, telephone, etc.) on-site de-installation and anything else necessary to provide for the removal/deactivation of the 1.5 Tesla (T) Mobile Magnetic Resonance Imaging (MRI) System trailer at the Gene Taylor Community Based Outpatient Clinic, Springfield, MO. All work associated with removal/de-activation in accordance with the performance work statement. PRINCIPAL NAICS CODE: 621512 - Diagnostic Imaging Centers PRODUCT/SERVICE CODE: W065 - Lease or Rental of Equipment - Medical, Dental, and Veterinary Equipment and Supplies 0003 12.00 EA __________________ __________________ Lease Mobile MRI Trailer to include Equipment and Service in accordance with the Performance Work Statement Contract Period: Base POP Begin: 10-01-2024 POP End: 09-30-2025 PRINCIPAL NAICS CODE: 621512 - Diagnostic Imaging Centers PRODUCT/SERVICE CODE: W065 - Lease or Rental of Equipment - Medical, Dental, and Veterinary Equipment and Supplies 1001 12.00 MO __________________ __________________ Lease Mobile MRI Trailer to include Equipment and Service in accordance with the Performance Work Statement Contract Period: Option 1 POP Begin: 10-01-2025 POP End: 09-30-2026 PRINCIPAL NAICS CODE: 621512 - Diagnostic Imaging Centers PRODUCT/SERVICE CODE: W065 - Lease or Rental of Equipment - Medical, Dental, and Veterinary Equipment and Supplies 2001 12.00 MO __________________ __________________ Lease Mobile MRI Trailer to include Equipment and Service in accordance with the Performance Work Statement Contract Period: Option 2 POP Begin: 10-01-2026 POP End: 09-30-2027 PRINCIPAL NAICS CODE: 621512 - Diagnostic Imaging Centers PRODUCT/SERVICE CODE: W065 - Lease or Rental of Equipment - Medical, Dental, and Veterinary Equipment and Supplies 3001 12.00 MO __________________ __________________ Lease Mobile MRI Trailer to include Equipment and Service in accordance with the Performance Work Statement Contract Period: Option 3 POP Begin: 10-01-2027 POP End: 09-30-2028 PRINCIPAL NAICS CODE: 621512 - Diagnostic Imaging Centers PRODUCT/SERVICE CODE: W065 - Lease or Rental of Equipment - Medical, Dental, and Veterinary Equipment and Supplies 4001 12.00 MO __________________ __________________ Lease Mobile MRI Trailer to include Equipment and Service in accordance with the Performance Work Statement Contract Period: Option 4 POP Begin: 10-01-2028 POP End: 09-30-2029 PRINCIPAL NAICS CODE: 621512 - Diagnostic Imaging Centers PRODUCT/SERVICE CODE: W065 - Lease or Rental of Equipment - Medical, Dental, and Veterinary Equipment and Supplies GRAND TOTAL __________________ Page 1 of Page 9 of 9 Page 1 of 52.232-18 AVAILABILITY OF FUNDS (APR 1984) Funds are not presently available for this contract. The Government's obligation under this contract is contingent upon the availability of appropriated funds from which payment for contract purposes can be made. No legal liability on the part of the Government for any payment may arise until funds are made available to the Contracting Officer for this contract and until the Contractor receives notice of such availability, to be confirmed in writing by the Contracting Officer.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C25624Q0713- Combined Synopsis
- 2×Combined SynopsisCurrentJul 12, 2024
W065--Mobile MRI in Springfield MO
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Department of Veterans Affairs requires Diagnostic Medical Physics Services in support of NF/SG VHS Hospitals and Clinics. | - | Solicitation | 11/17/2026 |
Department of Veterans Affairs requires Diagnostic Medical Physics Services in support of NF/SG VHS Hospitals and Clinics. The proposed solicitation is expected to be posted within 24 hours of this notice. | - | Pre-Solicitation | 11/17/2026 |
Pre-solicitation Notice: 3T Mobile Magnetic Resonance Imaging (MRI) Services The Bruce W. Carter Department of Veterans Affairs Medical Center (BWCVAMC), Miami Veterans Affairs Healthcare System (MVAHCS), 1201 NW 16th Street, Miami, FL 33125, intends to solicit a Request for Quotation (RFQ) as a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, to provide services necessary to perform 3T Mobile Magnetic Resonance Imaging (MRI) Services to eligible beneficiaries of the MVAHCS. The Contractor shall provide a 3T MRI Trailer, including Board Certified MRI Technologists, on site in accordance with the specifications provided by the VA for beneficiaries of the Miami VA Medical Center. The Contractor shall propose a minimum of three (3) key personnel for credentialing and scheduling. The VA Full-Time Equivalency (FTE) is defined as a minimum of 80 hours every two (2) weeks, excluding Federal holidays. A minimum of two (2) Board Certified MRI Technologists must be available, with at least one (1) additional Board-Certified MRI Technologist recommended to cover absences. The contractor employees and subcontractors must maintain required licenses, permits, and certifications. Contractor personnel must be proficient in all technical skills required and be able to speak, read, write, and understand English fluently. The Contractor shall provide verification documents upon request from the Contracting Officer (CO) or Contracting Officer s Representative (COR), including evidence of ongoing competency, training, education, and explanations for any gaps in professional history. Contractor personnel shall comply with all applicable VA Medical Staff By Laws, Rules, and Regulations. QUALIFICATIONS: Certification and Registration: All Contractor s MRI technologists must hold certification and current registration for MRI by the ARRT and be certified in Basic Life Support (BLS). All continuing education courses required for maintaining certification and registration must be kept up to date at all times. Documentation verifying current certification and registration shall be provided by the Contractor to the VA COR on an annual basis for each year of contract performance, and whenever renewals occur. Credentialing and Privileging: Credentialing is to be done in accordance with the provisions of VHA Directive 1100.20 referenced above. The Contractor is responsible for ensuring that proposed MRI technologists possess the requisite credentials enabling the granting of privileges. Technical Proficiency: Contractor s MRI technologists must be technically proficient in the skills necessary to fulfill the government s requirements, including the ability to speak, understand, read and write English fluently. Contractor shall provide documents upon request of the CO/COR to verify current and ongoing competency, skills, certification and/or licensure related to the provision of care, treatment and/or services performed. Contractor shall provide verifiable evidence of all educational and training experiences including any gaps in educational history for all contractor s personnel and contractor s personnel shall be responsible for abiding by the Facility's Medical Staff By-Laws, rules, and regulations (referenced herein) that govern medical staff behavior. The period of performance is expected to be from April 15, 2027, through April 14, 2032. The authority of for this procurement is Title 38 USC 8153, Health Care Resources (HCR) Sharing Authority, Federal Acquisition Regulation (FAR) Part 12 Acquisition of Commercial Products and Commercial Services in combination with FAR part 19 IAW FAR Overhaul 12. 103. The solicitation document will be issued as Request for Quotation (RFQ) 36C24827Q0018 as a 100% SDOVSB set-aside solicitation on or about November 06, 2026. If an award cannot be made to a Service-Disabled Veteran-Owned Small Business, the solicitation will be cancelled, and the requirement resolicited. Interested contractors will be responsible for downloading copies of the solicitation and any subsequent amendments from this website. No hard copies will be made available. The solicitation will provide instructions to contractors about the response to the RFQ submission process. Prospective contractors are encouraged to register their interest in the solicitation on the SAM.gov | Contract Opportunities website so that they are notified of the issuance of the solicitation and any amendments. In accordance with FAR 52.204-7, System for Award Management (SAM), prospective contractors must be registered in SAM to be eligible for award. Contractors may obtain SAM information at https://sam.gov/. Registration is free and potential quoters are encouraged to visit the SAM website (SAM.gov | Entity Information). The NAICS Code for this procurement is 621512 Diagnostic Imaging Centers; Product/Service Code: Q522 Medical Radiology. The Business Size Standard is $19 million. Any questions concerning this announcement should be directed to Rosetta Quinn, Contract Specialist via email at rosetta.quinn@va.gov and include the solicitation number on subject line (36C24827Q0018). | - | Pre-Solicitation | 11/06/2026 |
The PWS Place of Performance has been corrected to read : 4500 S. Lancaster Road, Dallas , TX 75216 This correction notice does not constitute a solicitation or commitment by the Government. End of Document | - | Market Research | 11/13/2026 |
Description of Requirement: The Contractor shall furnish all personnel to provide services necessary to perform onsite Medical Physicist Services to eligible beneficiaries of the Department of Veterans Affairs Medical Center, James H. Quillen VA Medical Center (hereinafter referred to as VAMC). The current need for on-site services is primarily for vacation coverage however; the need may change over the term of the contract to include full-time on-site coverage. All VHA Radiation Oncology Services are accredited by a nationally recognized accrediting body contracted through the National Radiation Oncology Program (NROP). As such any Contractor providing on-site radiation oncology services must adhere to all the policies and procedures; practice standards, guidelines, patient care operations; patient safety; quality assurance and quality management of radiotherapy planning, equipment, and delivery; and continuous quality improvement initiatives promulgated by the American College of Radiology, American Society for Radiation Oncology and American Association for Physicist in Medicine. Place of Performance: Services shall be provided on site in Radiation Oncology Service, James H. Quillen VA Medical Center, Corner of Lamont & Veterans Way, Mountain Home TN 37684. | - | Awarded | Open |
Additional Details
Solicitation Number
36C25624Q0713
Archive Date
Sep 29, 2024
Office Address
RIDGELAND, MS, 39157