Notice ID: 31a56b61283a4b58a314f140400163b1Combined Synopsis/Solicitation

J041--Metasys Maintenance

Archived on May 14, 2023. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
2:00 PM UTC−05:00
Posted
March 30, 2023
Notice type
Combined Synopsis/Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS
561210: Facilities Support Services
Agency
Department of Veterans Affairs

Notice details

Office
257-NETWORK CONTRACT OFFICE 17 (36C257)
Place of performance
West Texas Veterans Health Care System Big Springs VA Medical Center Attn: Engineering 300 Veterans Blvd., Big Springs, TX, 79720
Last updated
Dec 6, 2025

Identifiers

Solicitation number
36C25723Q0507
Notice ID
31a56b61283a4b58a314f140400163b1

Description

This is a Request for Quote (RFQ). The government anticipates awarding a firm-fixed price contract resulting from this solicitation. This RFQ is set aside for Service Disabled Veteran Owned Small Businesses (SDVOSB). This requirement will be evaluated as Best Value. All respondents must have an active registration in the System for Award Management at www.sam.gov. Interested SDVOSB must be listed as verified on the Vendor Small Business Certification (VetCert) database located at https://veterans.certify.sba.gov in order to receive contract awards under the Veterans First Contracting Program. Department of Veterans Affairs, Network Contracting Office 17, is soliciting offers for: Metasys Maintenance for the West Texas Veterans Health Care System in accordance with the Statement of Work. Offeror shall submit offers directly via email to Maria Orosco-Hofmann, Contract Specialist, at Maria.Hofmann@va.gov Subject line of e-mail shall be Quote - 36C25723Q0507 Metasys Maintenance by Due Date/Time specified in Block 8 of the Standard Form (SF) 1449 of the solicitation.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Sep 27, 2024

NAICS

561210

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C25723Q0507
  1. Combined Synopsis
  1. 2×
    Combined SynopsisCurrentMar 30, 2023

    J041--Metasys Maintenance

    Notice 31a56b61283a4b58a314f140400163b1 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Request for Quote: 36C24727Q0073 The Department of Veterans Affairs, Columbia Healthcare System, WJB Dorn VA Medical Center, requires one-time chiller tube cleaning services for two chillers located in the facility s Chiller Plant. The Contractor shall provide all labor, supervision, travel, equipment, tools, supplies, materials, and incidental services necessary to complete the work described in this Statement of Work/Performance Work Statement (SOW/PWS). 1.2 Facility Background The WJB Dorn VA Medical Center is a 216-bed medical facility providing acute medical, surgical, psychiatric, and long-term care services. The facility is located in Columbia, South Carolina, and provides primary, secondary, and selected tertiary care.
-Combined Synopsis11/27/2026
White City Boiler Inspection Services Solicitation Number 36C26026Q0977 Due to a large number of questions, as the CO, I am extending the offer due date to 11/13/2026. I will allow questions for 1 week starting on 11/02/2026 – 11/06/2026. This Solicitation (36C26026Q0977) will remain an SDVOSB 100% total set aside. If you have any questions please email: Jeremiah.Middleton2@VA.GOV ________________________________________________________________________________________________________ The objective of this solicitation is to provide VA Southern Oregon Rehabilitation Center and Clinics (VA SORCC) with Boiler Plant Inspection Services. The period of performance shall be as follows: Base Year: 12/1/2026 to 11/30/2027 Option Year 1: 12/1/2027 to 11/30/2028 Option Year 2: 12/1/2028 to 11/30/2029 Option Year 3: 12/1/2029 to 11/30/2030 Option Year 4: 12/1/2030 to 11/30/2031 Background: The VA SORCC has three Power boilers, each rated at 250HP operating at low pressure (<15 psi), gas and oiled fired. Yearly state inspections are required on all three boilers, one deaerator/ feed water tank (DA/FWT), one heat recovery tank (HRT), one condensate storage tank (CST), and one bottom blow tank (BBT). ******Option year three will require the yearly state inspections on all three boilers, one deaerator/ feed water tank, one heat recovery tank, one condensate tank, and one bottom blow tank and have a Non-Destructive Test (NDT), And a Life Expectancy report performed on the DA/FWT ******. A NEW PWS HAS BEEN UPLOADED TO SAM.GOV ON 11/1/2026 A NEW 1449 SOLICITATION HAS BEEN UPLOADED TO SAM.GOV ON 11/1/2026 Amendment 0002 is no longer valid due to a new PWS being issued on this solicitation. Before you send any questions please make sure you have read all of the amendments, PWS and 1449.
-Solicitation11/13/2026
Amendment to Combined Synopsis-Solicitation for Commercial Products and Commercial Services RFQ: 36C24127Q0016 Water Management Program and Chemical Testing Effective Date: 01/15/2026 Revision: 03 This is a combined synopsis/solicitation Amendment 0001 with a 100% SDVOSB/VOSB set-aside for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is a request for quotations (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01. The associated North American Industrial Classification System (NAICS) code for this procurement is 561210 with a small business size standard of $19 million. The Department of Veterans Affairs Network Contracting Office 01 is seeking to purchase the supplies or services described in the following Statement of Work. This is a combined synopsis/solicitation Amendment 0001 notice synopsizing an upcoming RFQ solicitation to satisfy the requirements of RFO FAR 5.2 and RFO FAR 5.3. All interested parties should register via SAM.gov interested vendors list. It is the responsibility of the offeror to monitor and download amendments from SAM.gov Contract Opportunities, which may be issued to this solicitation. In accordance with RFO FAR 52.204-7, RFO FAR 2.101, and VAAR 802.101, prospective firms must be registered in SAM (www.sam.gov), and in SBA VetCert (Veteran Small Business Certification (sba.gov)) databases prior to award. ((Note: In accordance with Public Law 109-461, 38 USC 8127, and NDAA 2021, all vendors claiming Small Business status in accordance with the Veteran's First Contracting Program must be VERIFIED by the Small Business Administration (SBA)). Also, to qualify for a VA contract, vendors must be vendorized by completing Form 10091 at URL Â https://www.cep.fsc.va.gov/ . The purpose of this solicitation amendment is to: 1) Add Questions and Answers document. 2) Update SOW 3) Extend Solicitation due date until 11/06/2026 at 12:00 PM EST. Offerors should carefully follow instructions included in 52.212-1 and for evaluation criteria specified in FAR clause 52.212-2. Pricing should be on page 2. Interested persons may contact the Contract Specialist via email at pamela.parham3@va.gov regarding this procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer
-Combined Synopsis11/06/2026
-AwardedOpen
What are the hours of operation for Generator Maintenance? This is in the SOW Can you provide a Document with each Back-up Generator Model # s &Serial # s? This is Attachment A of the package Please Confirm the Voltage of the Generators? 480 and 240 Regarding Contractor Provided Consumables, many of the items listed are typically repairs quoted and approved before work proceeds on this and some parts(hoses and belts). As an outside vendor there is no way to effectively build this into your maintenance plan to guarantee effective cost for both the vendor and for Edward Hines VA. We request this section is altered to allow for these costs to be sectioned out for repairs and for one annual service to replace filters and oil. See Attachment B. How many Generators have Diesel Engines? All of them Are there any Generators with difficulty accessing (Roof, Parking Garage, Basement)? If so, which units are they? NO Are your Generators within 50 ft of the Entry Door, where our truck will be parked? Yes Are the Annual Load Tests performed with your Minor B-PMs? No Can I get the age of each equipment if possible? See Attachment A Please clarify the Unscheduled Repair CLIN amount. Is the stated $50,000 intended to mean $50,000 per contract year? This is just a funding item for me to populate an unscheduled maintenance clin for me to address items the break. Where should emergency travel and labor be priced? All previous contracts has local labor. Never had this issue. Build it in your quote. Will VA furnish diesel consumed during inspections? VA furnishes Fuel for the generators Period. Can you provide any previous maintenance reports, emergency calls, major repairs, etc.? After Award. Consumables Attachment Section 2.1 states Replace PM Consumables as required and references Attachment 1, while the solicitation package includes Generator Consumables Attachment B. Please confirm that Attachment B is the document intended by the reference to Attachment 1, and that the consumables identified in Attachment B are to be furnished and replaced by the contractor as required during preventive maintenance and included within the applicable PM CLIN pricing. Consumables are outlined in Attachment B. Work Hours / Load Bank Testing Section 4.3 identifies the monthly PM for the two 600 kW generators and one 500 kW generator as occurring on the second Tuesday of each month from 4:00 AM to 7:00 AM, while the 1250 kW and 750 kW generators may be serviced during normal business hours. Please confirm whether the annual load-bank testing, ATS maintenance, sampling, and other annual maintenance activities may also be performed during normal business hours unless otherwise coordinated with the COR. The 600 s, and 500 are backing up a critical production line that is old and has issues during power transfers. We require them and their associated equipment to be cycled or maintained prior to that department s workday start, so they can start the production line on time with no delay. This department is the Consolidated Mail Order Pharmacy (CMOP). All the generator maintenance is to be performed on the second Tuesday of each month, we need the CMOP Generators started and done first. Transformer Annual Inspection and IR Scan The scope includes quarterly energized transformer inspections as well as an annual inspection that includes additional maintenance activities and an IR scan. The pricing schedule only provides a quarterly transformer CLIN with a quantity of four. Please confirm whether the annual transformer inspection and IR scan are to be included within the pricing for the four quarterly inspections, with one quarterly service incorporating the annual work, or if the annual service is to be priced separately. Please confirm the intended operating condition for the annual IR scan, as it appears under the annual de-energized inspection section. Annual Transformer and ATS IR Scanning Procedure The annual infrared (IR) scan of transformer lugs and automatic transfer switches (ATSs) is to be completed while the equipment is energized, prior to any deenergizing procedures. This approach allows for the identification of potential faults under operating conditions, ensuring that any issues are detected before maintenance begins. Once the IR scan is performed, any necessary repairs should be made during the scheduled deenergized maintenance period. This ensures that faults identified during the scan can be addressed safely while the equipment is not under load. The IR scan should occur once each year and, whenever possible, should be scheduled close to the time of the annual deenergized maintenance. This coordination facilitates efficient fault resolution and minimizes downtime. In the event of an emergent issue identified during the scan, immediate corrective action will be taken to address the problem as soon as possible, regardless of the scheduled maintenance cycle.
-Combined Synopsis10/19/2026

Additional Details

Solicitation Number

36C25723Q0507

Archive Date

May 14, 2023

Office Address

San Antonio, TX, 78240