Notice ID: 98ccdfa444714248b89894859921fb7aCombined Synopsis/Solicitation
J045--Condenser Water System Repairs
Archived on June 28, 2024. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 1:00 PM UTC−05:00
- Posted
- May 22, 2024
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 811310: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 257-NETWORK CONTRACT OFFICE 17 (36C257)
- Place of performance
- VAMC Garland 2300 Marie Curie Dr. Garland, TX 75042
- Last updated
- Dec 6, 2025
Identifiers
- Solicitation number
- 36C25724Q0559
- Notice ID
- 98ccdfa444714248b89894859921fb7a
Description
INTENTIONALLY LEFT BLANK
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C25724Q0559- Combined Synopsis
- 3×Combined SynopsisCurrentApr 23, 2024
J045--Condenser Water System Repairs
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
| - | Combined Synopsis | 11/10/2026 | |
RFQ Amendment 0002 | - | Combined Synopsis | 10/22/2026 |
| - | Awarded | Open | |
PURPOSE: This is a Request for Information(RFI)/Sources Sought announcement only. This is not a solicitation announcement. The NCO 15 Consolidated Mail Outpatient Pharmacy(CMOP), Contracting office is conducting market research only to gain knowledge of potential qualified sources and is issuing this sources sought notice for the procurement of services in support of robotics equipment at the Lancaster CMOP Lancaster, TX: Preventative Maintenance Emergency Repairs Diagnostics Looking for potential vendors who can perform the stated requirement below. Production robots are utilized in placing vials from the automated equipment into Totes for further A-Frame items or de pucking into totes for packing. This process cannot be done by operators, and as such, these Mitsubishi robots are imperative to the overall operations of the facility. Contractor shall provide sufficient, competent, and qualified personnel to perform the necessary routine or preventive maintenance, emergency diagnostics, and repairs of two production floor Mitsubishi robots utilizing proper manufactured specified procedures. Contractor will be responsible for using the most current manufacturer manuals and checklists as needed. - Mitsubishi Industrial Robot Instruction Manual, Robot Arm Setup and Maintenance (RH3FH / RH6FH / RH12FH / RH20FH Series)_MELFA BFP-A8868-E_Copyright 2012 -Appendix A: Mitsubishi Robot Preventive Maintenance Checklist Type of Equip - Make - Model Mitsubishi Robot - Mitsubishi - RH-6FH5520-D1-S13 CONTROLLER - Mitsubishi - CR750-06HD1-1-S13 Mitsubishi Robot - Mitsubishi - RH-6FH5520-D1-S13 CONTROLLER - Mitsubishi CR750-06HD1-1-S13. Offers are not being solicited at this time. The Government does not intend to award a contract on the basis of this request for information. Vendors are required to address the following questions to be considered a viable source for future needs; Have you ever been licensed or certified to work on this type of equipment? Yes or No Can you provide past historical references for this type of service? Yes or No Any responses to this sources sought must include the following information. Your company s POCs: Name Phone Number Email Address Your Company s SAM Unique ID Number Your Company s Capability Statement Interested sources may respond to this notice via email to wade.cunningham@va.gov , on or before October 20th 2026 @ 12:00 p.m. Central. This Request for Information does not obligate VA to the release of a solicitation. ATTACHMENTS: Statement of Work Mitsubishi Industrial Robot Instruction Manual Wage Determination | - | Market Research | 10/20/2026 |
SITE VISIT A site visit will be conducted on Monday, November 16, 2026, at 9:00 AM EST at the VA Medical Center, Manchester, 718 Smyth Road, Manchester, NH 03104. The purpose is to allow quoters to inspect the existing Eaton Powerware 9390 UPS, the installation location, access routes, and site conditions relevant to the UPS replacement and ongoing maintenance. Attendance is recommended but not required to submit a quotation. Quoters who do not attend are responsible for obtaining the information necessary to prepare a quote and will not be relieved of any contract obligation on the basis of not having attended. Quoters intending to attend the site visit shall notify Andrew Obrien, Deputy Chief of Facility Service, by email at Andrew.Obrien@va.gov, and CC Shawn Lawrence, Contract Specialist at Shawn.Lawrence@va.gov, no later than Thursday, November 12, 2026, at 5:00 PM EST. The email shall include the name, company, and citizenship of each attendee for facility access. Each attendee shall bring a valid government-issued photo ID and report to Facility Service in Building 6 upon arrival. Attendees shall comply with all facility safety, PPE, and security requirements. Statements made during the site visit do not change the solicitation. Any information that affects the solicitation will be furnished to all quoters only through a written amendment. Questions raised at the site visit should be submitted in writing per the instructions in 52.212-1 to receive a binding Government response. Quotation delivery: Submit quotations via email to Shawn.Lawrence@va.gov no later than November 26, 2026, at 5:00 PM EST. Questions regarding this solicitation shall be submitted in writing by email to the Point of Contact no later than 5:00 PM EST on November 19, 2026. | - | Combined Synopsis | 11/26/2026 |
Additional Details
Solicitation Number
36C25724Q0559
Archive Date
Jun 28, 2024
Office Address
San Antonio, TX, 78240