GovChime
Notice ID: 828f883b588b480bb2b6cabbe02aeb24SolicitationArchived

Decontamination Trailer for San Antonio VA - Request for Quotes

Archived on October 7, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
1:00 PM EDT
Posted
September 18, 2025
Notice type
Solicitation
Set-aside
No Set aside used
NAICS
336212: Truck Trailer Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
257-NETWORK CONTRACT OFFICE 17 (36C257)
Place of performance
San Antonio, Texas, 78229
Last updated
Nov 8, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25725Q0899
Notice ID
828f883b588b480bb2b6cabbe02aeb24

Description

This solicitation is being issued as a full and open request. The vendor must be registered under NAICS 336212 to be eligible for the award.

Quotations due no later than 09/21/2025 at 1:00 PM/EST. 

Late quotes or documentation may be accepted if advantageous to the Government.  All comments or inquiries are to be submitted in writing via email to the Contract Specialist Joshua Weisman at joshua.weisman@va.gov by 09/19/2025 at 1:00 PM/EST.

A completed copy of the Price/Cost schedule must be submitted with proposals. See section B.2.

Offerors are to complete the Buy American Certificate at Provision 52.225-2 for applicable items.

Additionally, vendors are to accept or concur with the following items and provide applicable documentation to support technical capability; otherwise, the proposal will be considered non-response:

Technical:

  1. Vendor’s equipment, quality control, and service meet the general requirements that are requested in the statement of work. 

  1. Vendor’s equipment, quality control, and service meet the specifications outlined in the statement of Work (SOW).
  2. Vendor attests that there are minimal supply chain issues with the equipment, quality control, and servicing, through client testimony or vendor records and statistics.
  3. The Contractor shall provide the materials listed below to the Audie L. Murphy VA Hospital, San Antonio, TX as defined in the Scope of Work (SOW). 
  • 8.5’x24’ Heavy Duty enclosed white trailer
  • Additional 6” height added (exterior)
  • Additional floor cross members (12” OC)
  • Additional wall posts (12” OC)
  • 54” extended triple tube tongue
  • 6” I-beam to 8” I-beam upgrade
  • Extra reinforced heavy-duty ramp door w/ spring
  • 24” Advanced Technical Panels covered flap w 3” dock bumpers
  • Deluxe scissor jacks w/hand cranks
  • GFI wall receptacle (Interior/Exterior; 2 Gauge)
  • Fold down / Pull-out step for side door
  • LED back up lights
  • Electric Tongue Jack w/ lights and 12Volt battery
  • Side mounted turn signals (amber)
  • Extra Heavy-duty tongue jack (7000 # Capability)
  • ST 235/80R167/E Spare tire w/ 8 bolt silver
  • 110- Volt pkg w/ 30 Amp breaker panel
  • 50 Amp Service upgrade
  • 13,500 BTU roof-Mt air con w/ Heat Strip
  • E-series package #1 + 6” extra height (interior)
  • 12-volt interior wall switch
  • 110-volt interior wall receptable (2gang)
  • 50 Amp motor base plug
  • Cove trim (exterior)
  • Recess wall-Mt E-track (installed; steel frame reinforced mounted)
  • Recess Floor-mount E-track w/ Backer Plate
  • Insulated ceiling w 3/16” lauan liner
  • Bead board insulated (Styrofoam)
  • 12-volt battery w/ box (Interior or Exterior mount)
  • 40” white LED strip light (interior)
  • 8k winch w/ remote
  • Winch plate
  • Aluminum Frame shelving w/ lip
  • Axle upgrade 5200lbs to 7000lbs (14Klbs capacity)
  • 10 ga. Steel ATP floor, & 8’ X 6’ ramp gate strips
  • Three (3) Pack puck style locks
  • 26’ of thermal barrier exterior ceramic roof coating
  • 6” x 6’ Steel hinge ramp transition flap
  • Labor to install 110V battery tender
  • Custom Decal and installation (2) sides and rear
  • 24” exterior LED lights
  • 110V battery tender
  • GCP4 receptacle for 110V battery tender
  • Freight charge – single pull
  • E-tag

b. The Contractor shall ensure all the products are exact items indicated in the quote and in the exact quantity required.

  • Item location
  • Quantity
  • Manufacturer
  • Lot #
  • Serial #
  • Expiration date
  • Associated Critical storage data
  • Material Safety Data Sheets (MSDS) if required

Past Performance:

Vendors are to provide a minimum of three (3) professional references (name or person of contact, address, phone number, and professional experience.

Only quotes submitted by email will be considered. Submissions in any other format (fax, hard copy) will be deemed technically unacceptable outright and not considered for award.

Provisions that are incorporated by reference (by Citation Number, Title, and Date), have the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available.

  (a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers:

   Price

   Technical Capability

   Past Performance

   Technical and past performance, when combined, are equal to price.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Jan 30, 2026

NAICS

336212

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Documents

Files (1)

  • S02 - 36C25725Q0899 - Revised for Full and Open.pdf

    467 KBAdded in Solicitation version 3Posted
    Download

Lifecycle

  1. 3
    Version 3SolicitationArchivedCurrent

    Decontamination Trailer for San Antonio VA - Request for Quotes

    Notice 828f883b588b480bb2b6cabbe02aeb24 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Amendment to add Set aside code. The purpose of this amendment is to add a graphics attachment and all exterior graphics require Government approval prior to application . General and Structural SpecificationsBase Model: 2026SCOTTY Safety Theater 35-SprinklerDimensions: 35 ft. Length x 8 ft. WidthFrame Construction: Tubular 2 by 6 steel frame.Exterior Finish: Gelcoat white fiberglass exterior.Roofing: Commercial rubber roof (includes a 12-year limited warranty).Viewing Windows: Large Lexan windows for safe, exterior live-fire viewing.Stabilization and Hitch: Upgraded Electric Stabilizing Jacks with auxiliary battery (replaces standard manual jacks). Electric hitch jack.Towing and Weight: Requires vendor verification. (Axle count, tire size, and exact GVWR were not specified in the base documentation).Power, Climate Control, and ElectronicsPrimary Power System: 50-amp service with a 25 ft. removable twist-lock power cord.Power Converter: 80-amp power converter integrated with a battery charging system.Auxiliary Power: Honda EU7000is Super Quiet Electric Start Generator (60dB). Mounted on the hitch with a soft vinyl cover.Heating and Cooling: Two (2) 13,500 BTU Dometic AC units with heat pumps. Two (2) 4,266 BTU electric ceiling heaters.Ventilation: High-volume air circulation system.Outlets: Ample duplex 110v receptacles; GFI-protected outlets in the kitchen and exterior.Interior and Multimedia Features:Interior Design: Urban-chic cabinets, countertops, and finishes. Interior walls certified by the GREENGUARD Children and Schools Certification Program.Lighting: Immersive lighting package including black lights, theater stage lights, and dimmable floor/ceiling lights.Multimedia and Connectivity: Surround sound system with 1 each speakers. Installed WIFI antenna and a plug-and-play rack-mounted computer system.Exterior Monitor Upgrade: 55 in. LED touch screen monitor built into the exterior wall for outside viewing, protected by a locking roll-up door.Specialized Demonstration Features:Sprinkler Activation Room (Live Burn Area)Walls and Ceiling: Aluminum diamond tread plate walls in the burn room. Galvanized steel heat shield covers the ceiling and front wall.Sprinkler System: 135-degree sprinkler head fed by a 20-gallon water tank.Pump: 1/2 hp pump located in a pump cabinet, utilizing PEX and copper piping.Drainage: Trough-style drain with sloped floors leading to an exterior drain pipe.Seating/Props: Aluminum tube chair with two removable seat cartridges. Includes three boxes of Excelsior packing material for clean burning.Kitchen Module and Props:Burning Trash Can Prop: Located in the kitchen. Simulated flame effect uses a combination of airflow, light, and fabric (no smoke). Activated by a wall switchSafety and Accessibility Options:Alarm Group Upgrade: Smoke Alarm for Hearing-Impaired with Strobe Light. Two (2) Carbon Monoxide Detectors (one hard-wired with switch, one digital read-out). Pull Station with horn and strobe (includes master cut-off switch).Accessibility: Foldable Wheelchair Ramp with On-Board Storage Compartment. (Note: Instructor provides assistance for entry/exit; ramp does not meet standard ADA slope requirements).Awning: Deluxe Electric 12v Rollout Awning (8 ft. x 21 ft.).Graphics and Aesthetics:Standard Exterior Graphics: Base graphics package.Exterior Graphics Full Wrap: Complete custom visual wrap for the 35 ft. trailer
53%
Combined Synopsis08/12/2026
The purpose of this amendment is to attach the graphics requirements and provide additional specifications for the trailer height, UPS system, EIA equipment rack, roof-mounted antennas, and exterior monitor. Procurement: 42 ft. Mobile Command Center (MCC) TrailerSCOPE:The contractor shall design, manufacture, and deliver one (1) custom-built, heavy-duty Mobile Command Center (MCC) trailer. The MCC will serve as a multi-agency incident command post for FES, Police, Guards, and Garrison Command Staff during large-scale emergencies.PLATFORM AND EXTERIOR SPECIFICATIONS:Dimensions: Minimum 42 ft. Length x 8 ft. Width (nominal).Hitch Type: Heavy-duty 5th-Wheel Kingpin (or Gooseneck) configuration, matched to a GVWR appropriate for the fully loaded trailer.Slide-Outs: Minimum of two (2) flat-floor slide-outs to maximize interior operational space.Leveling System: Heavy-duty automatic hydraulic leveling system (minimum 4-point).Awning: One (1) heavy-duty motorized awning on the curbside, positioned to cover the exterior monitor, with an automatic wind-retraction sensor.Graphics: Full custom exterior vinyl wrap with Department of War / Garrison FES branding and reflective striping (graphics package to be approved by the Government post-award).Lighting:Minimum of two (2) high-lumen LED scene lights per side (8 total).Full emergency warning light package (Red/Blue LEDs) conforming to emergency vehicle standards.POWER AND CLIMATE CONTROL:Generator: Minimum 20kW Onan (or equivalent) commercial-grade diesel generator with remote interior start and custom fabricated fuel cell.Climate Control: Three (3) 15,000 BTU roof-mounted HVAC units with heat pumps/strips, ducted for even air distribution, capable of maintaining 70 F interior temperature in extreme high-heat environments (110 F+ ambient).Shore Power: Heavy-duty shore power connection (e.g., 50A or 100A as appropriate for load) with a minimum 50-foot heavy-duty male-end umbilical cord.Power Protection: Rack-mounted Uninterruptible Power Supply (UPS) sized to support the communications and server rack to prevent drop-outs during power transition.INTERIOR LAYOUT AND FINISHES:Zones: Trailer must be divided into a Main Operations Area and a secure Conference Area, separated by a sound-deadening door. No lavatory or kitchenette to be included.Workstations: Six (6) total dedicated workstations. One (1) workstation must be customized specifically for a Dispatch Console.Desks/Cabinetry: Heavy-duty, commercial-grade desks and overhead/under-desk aluminum or high-pressure laminate storage cabinetry for each workstation.Whiteboards: Two (2) large magnetic dry-erase whiteboards (one in the main area, one in the conference area).COMMUNICATIONS AND TECHNOLOGY:Server Rack: Minimum one (1) full-height or half-height 19 inch EIA equipment rack structurally mounted and cooled.Radio Prep: Pre-wired for Government Furnished Equipment (GFE) Motorola and Harris radios. Must include roof-mounted antenna bases and coaxial cable runs to all six (6) workstations.Network/Data: Trailer must be pre-wired with CAT6 ethernet drops at all workstations, routed back to the server rack, ready for Government-installed FirstNet routing equipment.Monitors:One (1) large touchscreen interactive monitor mounted in the Conference Area. Interior Height: Thetrailer must have a minimum interior height of 80 inches (6 ft. 8 inches). This ensuresadequate head clearance for personnel and allows for the installation of overhead LEDlighting, wire runways, and ducted HVAC systems without restricting movement. ExteriorHeight: The overall exterior height of the trailer must not exceed 12 feet 6 inches (150inches) in its stowed/transport configuration. This measurement must include all roofmountedequipment, such as low-profile HVAC units, stowed light towers, and antennas, toguarantee clearance under standard highway bridges and overpasses. Runtime: The UPSsystem must be capable of powering all critical communication and network routingequipment for a minimum of 30 minutes under a full operational load. This runtime isintended to act as a power bridge, allowing safe power transition between Shore Power andthe onboard generator, or enabling a graceful shutdown of critical systems during a powerfailure. Wattage/Capacity: The syFor tstem must support a minimum continuous load of3,000VA / 2,700 Watts. The vendor must supply a double-conversion online UPS to ensuresensitive radio and IT equipment receive clean, regulated power, isolated from voltagespikes or generator sags. Rack Units (RU): The equipment rack must provide a minimumof 16U of usable rack space to accommodate patch panels, network switches, routers, theUPS, and radio chassis, while leaving room for future expansion. Rack Depth: The rackmust have a minimum usable depth of 25 inches (front-to-back rail depth) to safely housedeeper server-style equipment and the UPS chassis. The rack must also feature front andrear adjustable mounting rails and robust rear cable-management brackets designed towithstand transit vibration. Antenna Bases: The trailer must be equipped with a minimumof 6 roof-mounted antenna bases (standard threaded NMO mounts). Installation Detail: Thebases must be spaced at least 3 feet apart to prevent RF interference. They must be prewiredto the internal EIA equipment rack using low-loss coaxial cable (such as LMR-400or equivalent) and must include solid copper grounding planes integrated into the roofstructure. Monitor Size: The exterior display must be a 49-inch to 55-inch high-brightness,daylight-readable (minimum 1000 nits), commercial-grade outdoor monitor. Mounting andHousing: The monitor must be permanently housed in a recessed, weatherproof, andlockable exterior compartment rather than a removable mount. The compartment mustfeature gas-shock-assisted doors, integrated LED compartment lighting, and a heavy-dutyarticulating pull-out mount that allows the monitor to be angled for group briefings. Allexterior graphics require Government approval prior to application.
53%
Combined Synopsis08/12/2026
NOTICE OF INTENT TO SOLE SOURCE This notice is being published in accordance with Federal Acquisition Regulation (FAR) FAR 6.302-2 requiring dissemination of information for proposed contract actions. This is a notice of intent to award a sole source contract and is not a request for competitive quotes/proposals. The Department of Veterans Affairs, Network Contracting Office (NCO) 07, located at 3154 Perimeter Pkwy Augusta, GA is issuing this Notice of Intent (NOI) to inform industry contractors of the Government’s intent to execute a Sole Source Order under FAR Part 6, specifically FAR Part 6.302-2, Unusual and compelling urgency. This notice satisfies the posting requirements at FAR Part 6.305(b). The intended Contractor is Boyer Commercial Construction, Inc. located at 2122 S Beltline Blvd. Columbia, SC 29201. Place of Performance is William Jennings Bryan Dorn VAMC located at 6439 Gardner’s Ferry Road Columbia, SC 29209. The Columbia VAMC requires an emergency requirement for a temporary mobile oxygen trailer to supplement the disconnected main oxygen supply. The North American Industry Classification System (NAICS) for this requirement is 336212. The Product Service Code (PSC) is W041. The Small Business Administration (SBA) size standard for this sector is 1,000 Employees. This notice of intent is neither a formal solicitation nor a request for competitive proposals. No solicitation document is available and telephone requests will not be honored. No award will be made on the basis of unsolicited quotations or offers received in response to this notice. Any response to this notice must show clear, compelling and convincing evidence that competition will be advantageous to the Government. The intent of this synopsis is for informational purposes only. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. A determination by the Government not to compete this action based on this notice is solely within the discretion of the Government.
45%
Special Notice11/15/2026
21K Trailer
41%
Solicitation09/08/2026
amended to change NAICS code. Trailer
41%
Combined Synopsis08/27/2026

Additional Details

Solicitation Number

36C25725Q0899

Archive Date

Oct 7, 2025

Office Address

San Antonio, TX, 78240