GovChime
Notice ID: e20962bf98f14cecaa4831246daae4c2Sources SoughtArchived

6525--Compact B-Scan Ultrasound System VA Harlingen Healthcare Center

Archived on July 4, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:00 AM CDT
Posted
June 3, 2026
Notice type
Sources Sought
NAICS
339115: Ophthalmic Goods Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
257-NETWORK CONTRACT OFFICE 17 (36C257)
Place of performance
VA Harlingen Healthcare Center 2601 Veterans Drive, Harlingen, Texas, 78550
Last updated
Oct 30, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25726Q0621
Notice ID
e20962bf98f14cecaa4831246daae4c2

Description

Page 4 of 4 Page 1 of Page 1 of This market research notice is being conducted by Network Contracting Office (NCO) 17- VA South Texas (VASTHCS) facilities. VA Texas Valley Coastal Bend Healthcare System Optometry Section of Surgical Service is requesting a B-Scan Imaging Ultrasound System at one (1) location. The Optometry Department in Harlingen is requesting a new Compact B-Scan Imaging Ultrasound System to facilitate the increased demand for patient optical care. The proposed B-Scan Imaging Ultrasound System will allow the doctor to diagnose retinal detachments, tumors, and citreous pathologies. System Requirements and Specifications for Compact B-Scan Ultrasound System Must be lightweight and easily transportable (<5 kg, 8 lbs. recommended) and cart-based unit suitable for small examination rooms. Must have an integrated color high-resolution touchscreen with integrated DICOM connectivity. Must be Windows 11, DICOM compatible, and must support DICOM storage, worklist, and print functionalities to interface with VA Systems. Must have USB ports for data export, ethernet port, and HDMI output. Must have B-Scan Transducer frequency of 15 MHz. Must have built-in pattern recognitions phakic, aphakic, PMMA, acrylic, and silicone material for pseudo-phakic eye types. Must have automatic detection of scleral spike. Must have at least six (6) different methods for keratometric correction and implant calculation: History derived, refraction derived, contact lens method, Rosa regression, Shammas regression, Double K/SRK-T (Dr. Aramberri s formula). Must have the ability to display at least four (4) different IOL calculations. Contractor is responsible for installation and configuration of the newly provided Compact B-Scan Ultrasound System. Contractor is responsible for comprehensive system testing for the newly provided Compact B-Scan Ultrasound System. Testing documentation shall be provided to VATVCBHCS Biomedical Engineering prior to acceptance of equipment. Contractor shall be able to certify the newly provided Compact B-Scan Ultrasound System is safe and ready for use on patients. Delivery of all hardware should be completed within 90 days from date of award. Implementation of all hardware should be completed within 60 days after hardware delivery. Education and training may take 60 90 days after hardware implementation. Compact B-Scan Ultrasound System must include at least a one-year warranty. Responses shall include: Business Name Business Address Point of Contact Name Phone Number E-mail Address SAM UID Number Currently registered in SAM (Yes or No). If Yes, provide expiration date. NAICS code Business Size: Small or Large Type of Business: Service-Disabled Veteran Owned (SDVOSB), Veteran Owned (VOSB), 8(a), HUBZone, Woman-Owned (WOSB), etc. GSA or VA FSS Contract Number, if applicable Indicate the equipment/supplies manufacturer and country. All businesses eligible to provide these supplies are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement. Send responses to both the Contract Specialist. Contract Specialist: Mr. Rafael Rodriguez at Rafael.Rodriguez2@va.gov Responses in the email subject line shall state: 36C25726Q0621, Sources Sought Notice Responses due date: 06/09/2026- 11:00 AM CT DISCLAIMER: This notice is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this notice.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Rafael A Rodriguez
Rafael Rodriguez

Documents

Files (1)

  • 36C25726Q0621.docx

    21 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    6525--Compact B-Scan Ultrasound System VA Harlingen Healthcare Center

    Notice e20962bf98f14cecaa4831246daae4c2 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

36C25726Q0621

Archive Date

Jul 4, 2026

Office Address

San Antonio, TX, 78240