Z--Cable Pull and Accessories Installation Services for VA Medical Center Sheridan, WY, 82801
Overview
- Response deadline
- 12:00 AM UTC−05:00
- Posted
- June 27, 2018
- Notice type
- Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Notice details
- Office
- NETWORK CONTRACT OFFICE 19 (36C259)
- Place of performance
- VA Medical Center;1898 Fort Road;Sheridan WY 82801 USA
- PSC
- Z: MAINT, REPAIR, ALTER REAL PROPERTY
- Last updated
- Sep 10, 2025
Identifiers
- Solicitation number
- 36C25918Q9607
- Notice ID
- 66f2d4c5425836759593282290b402f3
Description
Cable Pull and Accessories Installation Services VA Medical Center Sheridan WY 82801 BRIEF SCOPE OF WORK Project Scope The contractor shall provide all labor, personnel, equipment and test equipment, tools, supervision, parts, materials (to include all cable and any needed accessories and/or other items) necessary to provide cable and accessories installation, onsite for Communications Systems located at the Sheridan VAMC facility and as defined in this Statement of Work (SOW). Purpose: Install cabling and terminations for expanding Network Infrastructure to support device (video) integration in various locations throughout the medical facility. Background: The facility is bringing on line, via the information network, an information display system that will provide veterans with health information and facility events relevant to educating veterans and improving their well-being. The video displays are located in patient waiting areas of which there are 6 that require a network connection. Network Cable Specifications: All cabling installed to be Plenum rated CAT6. Cabling is to be terminated (punched down) per ANSII standards. On the display end of the cable run, wall plates are to be mounted, allowing a male CAT6 plug to connect to the network and the color to be white, off-white, or eggshell. Wiring above the overhead ceiling (grid) will be suspended so as not to lay directly upon ceiling tiles. Utilizing existing cable trays are recommended. Prior to performing any new fire wall penetrations, the Safety Officer requires the proper documentation (provided by the Safety Office) and that the contractor follow all NFPA standards for ensuring fire wall integrity. On the network side (switch) the terminated and labeled cable will be run to the switch plus a 3-meter maintenance loop added at the network switch equipment rack. All completed cables are to be tested to ensure continuity. All services for this contract must meet manufacturer performance and technical specifications, Federal Regulations, and other specifications that may apply such as National Electric Code (NEC), Life Safety Code (LSC), Joint Commission (JC), and VA Regulations, American National Standards Institute (ANSI), Electronic Industries Alliance (EIA)/ Telecommunications Industry Association (TIA), and Building Industry Consulting Service International (BICSI) Telecommunications Distribution Methods Manual (TDMM). VA has adopted the National Fire Codes (NFC), except NFPA 5000, published by the National Fire Protection Association (NFPA). Scope of Work Locations: All cable runs connect a video device (patient/veteran waiting areas) to the nearest IT communications closet as follows: Dental Waiting Area -- 2nd Floor, Bldg. 71 -- 170 cable run (not including maintenance loop of 3 meters per switch, if required) Radiology Waiting Area -- 2nd Floor, Bldg. 71N -- 78 cable run (not including maintenance loop of 3 meters per switch, if required) Ambulatory Care Waiting Area -- 1st Floor, Bldg. 71 -- 75 cable run (not including maintenance loop of 3 meters per switch, if required) Pharmacy Waiting Area -- 2nd Floor, Bldg. 71N -- 38 cable run (not including maintenance loop of 3 meters per switch, if required) Laboratory Waiting Area -- 2nd Floor, Bldg. 71N -- 50 cable run (not including maintenance loop of 3 meters per switch, if required) Mental Health Waiting Area -- 1st Floor, Bldg. 8 -- 38 cable run (not including maintenance loop of 3 meters per switch, if required)
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
36C25918Q9607- Market Research
- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- Market ResearchJun 18, 2018
Z--Cable Pull and Accessories Installation Services for VA Medical Center Sheridan WY, 82801
- Pre-SolicitationJun 27, 2018
Z--Cable Pull and Accessories Installation Services for VA Medical Center Sheridan, WY, 82801
- SolicitationCurrentJun 27, 2018
Z--Cable Pull and Accessories Installation Services for VA Medical Center Sheridan, WY, 82801