GovChime
Notice ID: 391bfbf6e5854211b2de593b5f3ba239Sources SoughtArchived

J065--RFI Urology Endoscope Lease and Service Agreement

Archived on February 7, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM MST
Posted
December 23, 2025
Notice type
Sources Sought
NAICS
532490: Other Commercial and Industrial Machinery and Equipment Rental and Leasing
Agency
Department of Veterans Affairs

Notice details

Office
NETWORK CONTRACT OFFICE 19 (36C259)
Place of performance
Department of Veterans Affairs Salt Lake City Health Care Systems, Salt Lake City, Utah, 84148
Last updated
Nov 4, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25926Q0158
Notice ID
391bfbf6e5854211b2de593b5f3ba239

Description

Request for Information Urology Endoscope Lease with Service Agreement Disclaimer: This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. Responders are solely responsible for all expenses associated with responding to this RFI. Information Requested from Industry: In response to this RFI, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Scope of Work draft / Salient Characteristics List. Responses to market research table questionnaire shall be submitted to jacqueline.obryan@va.gov. If this information is not provided, then it will be assumed the entire requirement cannot be met. Description of Requirement: The Department of Veterans Affairs, Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for a lease of urology endoscopic equipment and a service agreement (brand name or equal) for the Salt Lake City Veterans Health Care System. The urology endoscopes and equipment will be used for pre-operative and post-operative care, and a service agreement. Requirement Item and Services: Brand name or Equal for all items to be included on the lease agreement. Required Salient Characteristics: Rigid Cystoscopes: Sheaths must be 19Fr, 20Fr, and 22Fr in outer diameter. Sheaths must include a cam-lock mechanism for bridge attachment. All sheaths must include a meatus stop. All sheaths must include shaft calibrations for urethral measurements. 19Fr sheath must have (2) 5Fr working channels with a double channel bridge and (1) 6Fr channel with single channel bridge. Color code green. 20Fr sheath must have (2) 6Fr working channels with a double channel bridge and (1) 7Fr channel with a single channel bridge and be color code red. 22Fr sheath must have (2) 7Fr working channels with a double channel bridge and (1) 10Fr channel with a single channel bridge and be color code blue. Bridges must be dual curved channel short bridge, single curved channel short bridge and examination short bridge. All bridges must have cam-lock for telescope attachments. All sheaths must be compatible with optical grasping and biopsy forceps and be compatible with 22Fr and 25Fr sheaths. Both must be used with 30 degree AND 70 degree telescopes. All rigid cystoscope sheaths, obturators, telescopes, bridges, etc. must be interchangeable and compatible with existing KARL STORZ rigid cystoscopy sets including Blue Light Rigid Cystoscopy Sets. Optical grasping and biopsy forceps must be compatible with KARL STORZ 20Fr, 22Fr and 25Fr sheaths. They must be able to be used with both KARL STORZ 70 and 30 degree telescopes. Bella 4K AIDA Image Management Unit: Security: Windows LDAP login, disable removable media export function, password-protected procedure cabinet, able to support encrypted USB, military level security. Must have Full HD, 4K, and 3D or still image and video capture functionality. The system must have HD, 4K, and 3D Dual Channel Recording for either simultaneously or independent recording of two images. Auto-populate patient data, VISTA compatible for network access, DICOM export to PACS and vendor neutral storage (VA approved). Export patient images / videos to EHR, PACS, StreamConnect, DVD, USB. Both patient and procedural information can be imported from the EHR / VISTA. Advanced surgical feedback. MPEG4 compression. Retroactive capture (DVR-like functionality). Customizable surgeon settings. Icon based user interface. Integrated workflow with both standard and customizable stored presets. Configurable mandatory patient fields. Smart built in touch screen for staff interface. The unit must be compatible and interchangeable with the KARL STORZ video platform currently in use at VAMC Salt Lake City and be controlled remotely via all models of KARL STORZ endoscopic camera heads and digital endoscopes. Blue Light Cystoscopy Rigid Telescopes: Telescopes must be Hopkins II 4mm, autoclavable with 30cm working length. They must be 30 degree and 70 degree angle of views with blue light rod lens technology Must be compatible and interchangeable with all KARL STORZ rigid cystoscope and bipolar resectoscope sets. Power LED Saphira D-Light PDD Light Source: Must be Dual LED light source Must include dual white light and PDD blue light mode ability with excitation filter mounted on the fly wheel Must include simple switchover between white light and PDD fluorescence excitation light in the selected operating mode via camera head or foot switch Must include 3 separate operating modes for various photosensitizers and fields of application Must include operating time of 30,000 hours Must include Type CF applied part according to IEC 60601-1 Must include integrated SCB (Storz Communication Bus) module for controlling the entire system from camera head Specifications: Lamp type: LED Color temperature: 6000 K (white light) Light intensity adjustment: Continuously adjustable Dimensions: 305 mm x 120 mm x 370 mm (w x h x d) Weight: approx. 7.4 kg Certified to: IEC 601-1, protection class 1/CF Saphira Image1 S Video Processor CCU s Technology: Camera Connect Units (CCU) must include 12G / 3G- SDI and HD DVI-D Outputs and be type CF device / defib. resistant Must be modular architecture design for future expandability and upgradability Must include Saphira Technology for BLCC Must include Chroma Enhancement Technology which identifies and brightens up dark areas in real time without overexposing the bright part of the image Must include Clara Enhancement Technology that allows in real time (no visible lag time) to eliminate dark areas in an image, allowing the surgeon to keep their telescope in the right distance from the surgical target and being able to effectively perceive and discern additional content. which is time consuming during a procedure Must include Pointer Visualization feature for pointer visualization overlay that facilitates effective verbal communication between the attending surgeon and his assistant Must include Grid Visualization Feature to facilitate effective verbal communication between the surgical team members minimizing operating time. Must include Burn-in Screen Saver; if the video system (camera controller, monitor) is not powered down the camera output is permanently displayed on the monitor and, after some time it is burned into the glass. This burnt-in image is overlaid to the surgical image leading to a significant quality reduction. Saphira BLCC High-Definition Camera Head: Must be compatible with Saphira Image1 S Camera Connect Unit Must be pendulum in design and high definition. Must have focus knob with 16mm focal length. Must have (3) programmable user control buttons. Must be 16 x 9 image format with 60 Hz image refresh rate. Ureteroscopes: Semi Rigid must have 7Fr distal tip 8.4Fr-9.9Fr single step conical sheath. Working channel: 3.4Fr Irrigation channel: 2.4Fr. Ureteroscope must have a straight eyepiece. 6 degree angle of view. Working length 43cm. Digital Single use flexible ureteroscope must be compatible with existing KARL STORZ camera control unit and other Image1 S KARL STORZ camera control units. Must have 9Fr sheath size with 3.5Fr working channel with 3 o clock position. Must have a 9Fr tapered distal tip. Must include CMOS chip technology and integrated LED light source for illumination. Deflection must be 270 degrees upward and downward. Deflection must be positive at the distal tip. Angle of view must be 105 degrees and working length must be 70cm. Resectoscope Set: Set Must have both Bipolar and Monopolar capabilities and be compatible with the KARL STORZ UH400 ESU Generator. Working Element must be bipolar, spring action with movable thumb action control, and compatible with KARL STORZ bipolar resectoscope electrodes and KARL STORZ bipolar high frequency cables. Resectoscope Sheath must be 26Fr, continuous flow with fixed inner sheath compatible with KARL STORZ bipolar working element, visual obturator and deflecting obturator. Working length must be 19cm. Inner sheath must have a ceramic tip for burn resistance. Locking mechanism must be cam lock design. Deflecting obturator must include the ability to only be deflected once it is locked within the 26Fr resectoscope sheath via a cam lock. HoLEP Set: 26 and 28Fr Continuous-flow LASER sheath for precise guidance of flexible LASER probes 5 Fr. working channel to allow the use of LASER probes up to 1.6mm Right angle 6 degree telescope with 25cm working length Rigid Telescopes must be a Hopkins glass rod lens in both 12 and 30 degree angle of view, outer diameter 4mm, working length 30cm, autoclavable, fiber optic light transmission incorporated Percutaneous Nephroscope: Must be a Hopkins rod lens wide-angle telescope with a 6 degree angle of view, must be a 25cm working length with a right-angled parallel eyepiece, autoclavable with integral working channel. must include an integrated luer-lock connection for inflow. Must be fixed non-rotatable, 26 Fr., WITHOUT ceramic insulation, must have integral guiding channel for laser probes up to 2.6mm. Must have a 5Fr working channel for up to 5 Fr. instruments and be compatible with 26 and 28Fr resectoscope sheaths. Must have a 26Fr and 28Fr continuous flow sheaths that include connecting port for continuous inflow-outflow, oblique beak with ceramic insulation, fixed inner sheath. Must be include and be compatible with hollow obturator and fascial dilator. Must include one single dilator instrument to be compatible with operating sheath. Must have LASER Working Insert for Enucleation, with 7.5 Fr. working channel. Must include visual obturators for 24/26 Fr sheaths. Forceps must have serrated jaws and ring handle with double action jaws, 10.5 Fr with a working length of 38cm. Scope of Work Requirements Contractors will deliver all leased equipment to the SLC Health Care System warehouse. During the entire lease, all equipment will be serviced by the vendor. The vendor will make sure all equipment is running as per manufacturer specifications. The services to be provided for the duration of the lease include the following: Protection1 Comprehensive Service Agreement that includes repair or exchange on any failure or breakage of covered equipment during contract term, without additional charge. No trade-in available. The C&A requirements do not apply, and a Security Accreditation Package is not required. Delivery location Department of Veterans Affairs Salt Lake City VA Medical Center 500 Foothill Dr. Salt Lake City, UT 84148 In response to this announcement, please provide all information requested below in this market research table questionnaire. If all information is not provided, then it will be assumed the entire requirement cannot be met: NAICS Code: Company Name: Address: UEI (Unique Entity ID) Number: Contact Name: Phone No.: Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder: Yes No FSS/GSA Contract Number: Effective Date/ Expiration Date: Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Available pricing structure of proposed solution: Pricing Model Please Indicate Availability Below: (Yes / No / NA) All on FSS Open Market only Mix of FSS & Open Market Fixed Monthly Equipment Rental Charge Fixed Monthly Service Agreement Price Other: (Please explain) Federal Acquisition Regulation (FAR) Market Rearch Questions: Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a: Domestic end product? _____________ (%) Foreign end product? _______________ (%) Country of Origin: Questions for Small Businesses ONLY: Limitations on Subcontracting RFO 52.219-14 What percentage of the work would be subcontracted to another company? ________ What is the business size of the subcontractor?______ Per RFO 52.219-14 the following conditions must be met: Services (except construction), it will not pay more than 50 percent of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract; Supplies (other than procurement from a nonmanufacturer of such supplies), it will not pay more than 50 percent of the amount paid by the Government for contract performance, excluding the cost of materials, to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both supplies and services, the 50 percent limitation shall apply only to the supply portion of the contract; If subcontracting, what added value do you offer (RFO 52.215-23): Nonmanufacturer Rule (RFO 52.219-33): Does your company manufacturer these proposed items? [Â ] yes [Â ] no Does your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________ Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________ Response Instructions: Do not provide more than 8 pages, including cover letter page. Submit your response via email to jacqueline.obryan@va.gov Submit your response NLT noon (MT) on Thursday, January 8, 2026; Mark your response as Proprietary Information if the information is considered business sensitive. VA has identified the appropriate North American Industry Classification System (NAICS) Code as 532490 Other Commercial and Industrial Machinery and Equipment Rental and Leasing with a Small Business size of $40 million. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the above listed Scope of Work / Salient Characteristics List. (End of Request for Information)

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Jacqueline O'Bryan (CO)
Contract Officer

Documents

Files (1)

  • 36C25926Q0158_1.docx

    825 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    J065--RFI Urology Endoscope Lease and Service Agreement

    Notice 391bfbf6e5854211b2de593b5f3ba239 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
The Department of Veterans Affairs (VA), NCO 19, Jack C. Montgomery VAMC, is issuing this combined late synopsis and post award notice for a sole source Protection1 Comprehensive Service Agreement award made to a VIP listed Service Disabled Veteran Owned Small Business (SDVOSB) under the authority of VAAR 819.7008 and FAR 6.302 5(b)(6). Under VAAR 819.7008(a)(2), SDVOSB sole source awards require that the requirement be synopsized and that the justification required by FAR 6.302 5(c)(2)(ii) be posted in accordance with FAR Part 5. Due to an administrative oversight, the synopsis and justification were not posted prior to award. The VA is issuing this combined late notice to meet the public posting requirements associated with this SDVOSB sole source authority Requirement Description: The VA requires a Protection1 Comprehensive Service Agreement providing full coverage maintenance, monitoring, and support for Karl Storz medical equipment located at the Jack C. Montgomery VA Medical Center. This service agreement ensures operational continuity, manufacturer compliant maintenance, and timely repair support for essential endoscopic and surgical systems. This award was made using other than full and open competition, in accordance with the VA Veterans First Contracting Program. The VA is concurrently posting the associated Justification and Approval (J&A) prepared in accordance with FAR 6.302 5(c)(2)(ii) and FAR 6.303 6.304, in compliance with FAR Part 5 posting requirements.
95%
AwardedOpen
61%
AwardedOpen
NOTICE OF INTENT TO SOLE SOURCE: The Department of Veterans Affairs Network Contracting Office 6, 100 Emancipation Drive, Hampton, VA 23667, intends to award a sole source Firm-Fixed-Price purchase order to B. BRAUN MEDICAL INC., 824 12TH Ave, Bethlehem, Pennsylvania 18018-3524 for the Salem VAMC, 1970 Roanoke Blvd, Salem, NC 24153 for a Service Agreement Contract on Twenty-three (23) Hemodialysis Units manufactured by B. Braun Medical. This contract action is for products for which the Government intends to solicit from only one source under the authority of FAR 13.106-1(b), Soliciting from a Single Source. The North American Industry Classification System (NAICS) for this requirement is 811210 with a business size standard of $34.0 Million. THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTATIONS. Responsible sources may identify their interest and capability to meet this requirement by submitting such information by 10:00 A.M., EST, on Monday, October 26, 2026. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs associated with the preparation of responses to this notification. All inquiries and submittals must be sent via email to Zanona Pickett, Contract Specialist, at zanona.pickett@va.gov. Telephone inquiries will not be accepted.
59%
Special Notice10/26/2026
The Department of Veteran Affairs, Veterans Health Administration, Network Contracting Office 08, intends to negotiate a sole source, Firm-Fixed Price Contract with Biosense Webster, Inc. for A Base + 2 OY Extended Service/Maintenance Agreement for Proprietary Medical Equipment. Biosense Webster, Inc. is the Sole Source Service Provider for the Biosense CARTO 3 System, and purchases of extended warranty agreements for Service/Maintenance. There are no authorized/approved third-party service providers to Service or Maintain Biosense Webster Technologies. In accordance with FAR 6.302-1 Only one responsible source and no other supplies or services will satisfy agency requirements due to Proprietary Software. This acquisition is for the Thomas H. Corey VA Medical Center, 7305 N. Military Trail, West Palm Beach, FL. 33410. The Government intends to award the contract to Biosense Webster, Inc. 31 Technology DR STE 200 Irvine, CA. 92618 SAMS UEI# LU6KBGZ1A362. This notice satisfies the requirement at FAR 5.201(b)(1), requiring publication of the proposed contract action. Contractors may submit a capabilities statement or quotation which may be considered by the agency for future procurement. The government shall not pay for any costs incurred by responses to this notice. It is the Government's belief that Biosense Webster, Inc. is the only Contractor that can fulfil the requirement to meet the need of the West Palm Beach VAMC. It is the Government's intention to solicit and negotiate with only this source. This notice of intent is not a request for competitive proposals. It is not a solicitation or request for offers. No solicitation package is available. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government. Responses to this notice are due on Friday, November 06, 2026, at 2:00PM (EST) to David Henry, Contracting Officer, via email at David.Henry3@va.gov
57%
Special Notice11/06/2026
THIS REQUEST FOR INFORMATION IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. DISCLAIMER This Request for Information (RFI) is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Revolutionary FAR Overhaul 10.001 (d), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI. End of Notice
57%
Market Research11/13/2026

Additional Details

Solicitation Number

36C25926Q0158

Archive Date

Feb 7, 2026

Office Address

Greenwood Village, CO, 80111