GovChime
Notice ID: 5c3a7b21607a4b16be34dc1b999ca0b2Solicitation

4110--NUTRITION WALK IN FREEZER

Archived on November 3, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM MDT
Posted
September 1, 2026
Notice type
Solicitation
NAICS
333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
NETWORK CONTRACT OFFICE 19 (36C259)
Place of performance
Jack C. Montgomery VA Medical Center, Muskogee, Oklahoma, 74401-1318
Last updated
Nov 3, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C25926Q0815
Notice ID
5c3a7b21607a4b16be34dc1b999ca0b2

Description

RFQ 36C25926Q0815 for Walk-In Freezer

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Peyton Wilkerson (Contractor)
Contract Support Specialist

Documents

Files (2)

  • 36C25926Q0815.docx

    120 KBAdded in Solicitation version 2Posted
    Download
  • 36C25926Q0815_1.docx

    23 KBAdded in Presolicitation version 1Posted
    Download

Lifecycle

  1. 1
    Version 1Presolicitation

    4110--NUTRITION WALK IN FREEZER

    Notice de4ef2437fbf43c4be68837ffa599828 on SAM.gov

  2. 2
    Version 2SolicitationCurrent

    Type changed from Presolicitation to Solicitation

    4110--NUTRITION WALK IN FREEZER

    Notice 5c3a7b21607a4b16be34dc1b999ca0b2 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
95%
Combined Synopsis10/20/2026
Page 2 of 2 THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide brand name or Equal Leer Combo Indoor Walk-in Coolers and Freezer for the Captain James A. Lovell Federal Health, North Chicago, IL 60064-3048. Salient Characteristics Walk-In Coolers And Freezer: Dimensions And Basic Description Leer Combo Indoor Walk-in: 44' 6 3/4" x 31' 7" x 8' 6" Freezer (-10°) (5 1/2" Wood Rail Polyurethane) 15' 3" x 31' 7" x 8' 6" Cooler (35°) (4" Wood Rail Polyurethane) 14' 1 7/8" x 31' 7" x 8' 6" Cooler (35°) (4" Wood Rail Polyurethane) 15' 1 7/8" x 31' 7" x 8' 6" ** Freezer (-10°) panels 24" x 26.5"X 20.75" x 8'6 COLUMN WRAP (3 SIDED) 24" X 26" X 20.75" X 8'6 COLUMN WRAP (3 SIDED) Lag down Ceiling with Ceiling Hangers Included U.L. Flame Spread Rated, U.L. Electric Listed - NSF Listed 2009 EISA COMPLIANT Floor(s) Freezer (-10°) 24 Ga Stainless Steel 5 1/4" SUPER Floor with ADT Overlay Cooler (35°) Cooler (35°) Floorless with Wood Screed and Cove Molding Finishes 26 Ga Stucco White Interior Wall and Ceiling 26 Ga Stucco White Exterior Wall 26 Ga Stucco Galv Exterior Ceiling and Floor Doors (HD1) Door Cooler (35°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall (HD2) Door Freezer (-10°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall (HD3) Door Cooler (35°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall Accessories INCLUDES UL Labels Vapor Proof Light Kason 1277 Hinge Heated Vent Dial Flush Thermometer Exterior Ramp(36" Depth) Heated Frame Heated Plug Inside Release Push Handle 1092 Door Closer Standard Switch Strike Brushed Chrome Support Wheel REFRIG - SYSTEM 1 CCH0100LCBCZA0000 CU208/3 LT10HP HFC CP SCL STD FS PT Refrigerant Type : R448A REFRIG - SYSTEM 1 CEM0300BS6EMAB0000 UC208-230/1 EL 2F HFC STD 2EC ST Refrigerant Type : R448A REFRIG WARRANTY SYSTEM 1 4 YR EXT.COMP WARRANTY 10 HP SCROLL REFRIG - SYSTEM 2 CCH0030MCACZA0000 CU SCRO 3 HP 208/230V 3 PH OUTDOOR REFRIG - SYSTEM 2 CEM0225AS8AEBB0200 UC115/1 AR 1F HFC INT FEC ST Refrigerant Type : R448A Intelligent WARRANTY SYSTEM 2 4 YR EXT.COMP WARRANTY 3 HP SCROLL REFRIG - SYSTEM 3 CCH0030MCACZA0000 CU SCRO 3 HP 208/230V 3 PH OUTDOOR REFRIG - SYSTEM 3 CEM0225AS8AEBB0200 UC115/1 AR 1F HFC INT FEC ST Refrigerant Type : R448A REFRIG IG WARRANTY SYSTEM 3 4 YR EXT.COMP WARRANTY 3 HP SCROLL Submit responses to the Contracting Officer, Jennifer Mead, at Jennifer.Mead@va.gov no later than 10:00 a.m. (Central Standard Time), 6 October 2026. RFQ - 36C25226Q0721 shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. Each submittal shall also include the following business information: SAM UEI Organization Name Organization Address Point of Contact (including name, title, addresses, telephone number, fax number and Email address) Business size Socio-economic status ( IF SDVOSB or VOSB provide SDVOSB or VOSB CVE verification) Open Market or GSA/ FSS The NAICS Code 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing is applicable to this acquisition; the size standard is 1,250 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
95%
Market Research10/06/2026
Page 2 of 2 THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide brand name or Equal Leer Combo Indoor Walk-in Coolers and Freezer for the Captain James A. Lovell Federal Health, North Chicago, IL 60064-3048. Salient Characteristics Walk-In Coolers And Freezer: Dimensions And Basic Description Leer Combo Indoor Walk-in: 44' 6 3/4" x 31' 7" x 8' 6" Freezer (-10°) (5 1/2" Wood Rail Polyurethane) 15' 3" x 31' 7" x 8' 6" Cooler (35°) (4" Wood Rail Polyurethane) 14' 1 7/8" x 31' 7" x 8' 6" Cooler (35°) (4" Wood Rail Polyurethane) 15' 1 7/8" x 31' 7" x 8' 6" ** Freezer (-10°) panels 24" x 26.5"X 20.75" x 8'6 COLUMN WRAP (3 SIDED) 24" X 26" X 20.75" X 8'6 COLUMN WRAP (3 SIDED) Lag down Ceiling with Ceiling Hangers Included U.L. Flame Spread Rated, U.L. Electric Listed - NSF Listed 2009 EISA COMPLIANT Floor(s) Freezer (-10°) 24 Ga Stainless Steel 5 1/4" SUPER Floor with ADT Overlay Cooler (35°) Cooler (35°) Floorless with Wood Screed and Cove Molding Finishes 26 Ga Stucco White Interior Wall and Ceiling 26 Ga Stucco White Exterior Wall 26 Ga Stucco Galv Exterior Ceiling and Floor Doors (HD1) Door Cooler (35°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall (HD2) Door Freezer (-10°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall (HD3) Door Cooler (35°), 60" x 78" Overlap Mount, Left Hand Hinge, Interior Same As Wall, Exterior Same As Wall Accessories INCLUDES UL Labels Vapor Proof Light Kason 1277 Hinge Heated Vent Dial Flush Thermometer Exterior Ramp(36" Depth) Heated Frame Heated Plug Inside Release Push Handle 1092 Door Closer Standard Switch Strike Brushed Chrome Support Wheel REFRIG - SYSTEM 1 CCH0100LCBCZA0000 CU208/3 LT10HP HFC CP SCL STD FS PT Refrigerant Type : R448A REFRIG - SYSTEM 1 CEM0300BS6EMAB0000 UC208-230/1 EL 2F HFC STD 2EC ST Refrigerant Type : R448A REFRIG WARRANTY SYSTEM 1 4 YR EXT.COMP WARRANTY 10 HP SCROLL REFRIG - SYSTEM 2 CCH0030MCACZA0000 CU SCRO 3 HP 208/230V 3 PH OUTDOOR REFRIG - SYSTEM 2 CEM0225AS8AEBB0200 UC115/1 AR 1F HFC INT FEC ST Refrigerant Type : R448A Intelligent WARRANTY SYSTEM 2 4 YR EXT.COMP WARRANTY 3 HP SCROLL REFRIG - SYSTEM 3 CCH0030MCACZA0000 CU SCRO 3 HP 208/230V 3 PH OUTDOOR REFRIG - SYSTEM 3 CEM0225AS8AEBB0200 UC115/1 AR 1F HFC INT FEC ST Refrigerant Type : R448A REFRIG IG WARRANTY SYSTEM 3 4 YR EXT.COMP WARRANTY 3 HP SCROLL Submit responses to the Contracting Officer, Jennifer Mead, at Jennifer.Mead@va.gov no later than 10:00 a.m. (Central Standard Time), 6 October 2026. RFQ - 36C25226Q0721 shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. Each submittal shall also include the following business information: SAM UEI Organization Name Organization Address Point of Contact (including name, title, addresses, telephone number, fax number and Email address) Business size Socio-economic status ( IF SDVOSB or VOSB provide SDVOSB or VOSB CVE verification) Open Market or GSA/ FSS The NAICS Code 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing is applicable to this acquisition; the size standard is 1,250 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
95%
Market Research10/06/2026
JUSTIFICATION
88%
Sole Source / J&AOpen
Reason for amendment is to verify that the freezers should be designed for outdoor use. Reason for amendment: installation is not required; minimum size requirement was updated.
86%
Combined Synopsis08/07/2026

Additional Details

Solicitation Number

36C25926Q0815

Archive Date

Nov 3, 2026

Office Address

Greenwood Village, CO, 80111