Notice ID: 53dae5934e974454874a25f84a9fa64eAward NoticeAwardedArchived
H266 Portland VAHCS Hood Certifications and Testing Services
Awarded on September 11, 2026. Full description on SAM.gov.
Awarded tounder 36C26026P0793 (source: SAM.gov award notice)• $426.8K
Overview
- Posted
- September 11, 2026
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 541380: Testing Laboratories and Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 260-NETWORK CONTRACT OFFICE 20 (36C260)
- Place of performance
- Portland, Oregon, 97239
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
- Award date
- Sep 11, 2026
- Award amount (SAM.gov award notice)
- $426.8K
Identifiers
- Solicitation number
- 36C26026P0793
- Notice ID
- 53dae5934e974454874a25f84a9fa64e
- Award number (PIID)
- 36C26026P0793
Description
AWARD NOTICE
Award Overview
Award Number
36C26026P0793
Award Amount (SAM.gov award notice)
$426.8K
Award Date
Sep 11, 2026
Awardee
Awardee UEI
CTKTZ794WD85
Awardee CAGE Code
6XPL2
Awardee Address
Mankato, MN 56001, UNITED STATES
Original Solicitation
Notice ID: 53dae5934e974454874a25f84a9fa64e
Posted Date: Sep 11, 2026
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $49.3KSigned Oct 16, 2026
- $55.1KSigned Oct 1, 2026
- $99.1KSigned Oct 1, 2026
- $26.1KSigned Sep 30, 2026
- $40.8KSigned Sep 3, 2026
Contacts
Contracting Officer
Primary Contact
Danielle Carrico
Secondary Contact
BRIAN MILLINGTON
Documents
Files (4)
- Download
S06 AMENDMENT 36C26026Q0991 0002.pdf
139 KBAdded in Combined Synopsis/Solicitation version 7Posted - Download
S06 AMENDMENT 36C26026Q0991 0001.pdf
162 KBAdded in Combined Synopsis/Solicitation version 2Posted - Download
S02 RFQ 36C26026Q0991 Updated Per Amendment 0001.pdf
495 KBAdded in Combined Synopsis/Solicitation version 2Posted - Download
S02 RFQ 36C26026Q0991.pdf
513 KBAdded in Combined Synopsis/Solicitation version 1Posted
Lifecycle
- 5Version 5Combined Synopsis/SolicitationArchived
H266 Portland VAHCS Hood Certifications and Testing Services
- 4Version 4Award NoticeArchivedCurrent
Type changed from Combined Synopsis/Solicitation to Award Notice
H266 Portland VAHCS Hood Certifications and Testing Services
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
| - | Awarded | Open | |
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas. Q. When was the last annual inspection done, and when was the first inspection due under this contract? A. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. Q. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection. A. No particulate test performed during verification of newly installed or modified medical gas piping systems only. Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. A. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs. Q. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. A. VA requires this test to be performed annually. Q. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. A. Yes Q. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. A. Yes, if any deficiencies are found. Q. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. A. Only main Hospital and building 31 (cancer center) will be tested annually. Q. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI? A. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include "Over and Above Repair" to clarify that the contractor must notify the POC immediately if any repairs needs to be made. | - | Combined Synopsis | 11/12/2026 |
This is a pre-solicitation notice only; do not respond. The Veterans Health Administration (VHA), Network Contracting Office (NCO) 10, requires Sterile Processing Service Water Testing Services for the Marion, Fort Wayne, and Jackie Walorski VA sites in Indiana. The Government intends to publish a 100% set-aside solicitation for Service-Disabled Veteran-Owned Small Businesses on or about 11/25/2026. The solicitation will require the Contractor to furnish a quote providing all information requested in the Instructions to Offerors for Testing Laboratories and Services. The applicable NAICS Code is 541380 Testing Laboratories and Services with a size standard of $19.0 Million. Responses will be evaluated using comparative evaluation under FAR Parts 12 and 13; see solicitation for specific criteria. The resulting award will be a Base with Four Option Years, Firm Fixed Price contract. The closing date for receipt of offers is 12/10/2026 at 01:30 PM ET. All solicitation documents may be downloaded on the date of issuance through Contracting Opportunities via Sam.gov. Any amendments will be posted only on this website. The offeror is responsible for verifying the number of amendments issued. Offerors will have an opportunity to ask questions; details will be provided in the posted solicitation. After the questioning period closes, the Government will post responses to all questions on SAM.gov via a solicitation amendment within 3 business days. Phone calls will not be accepted. No site visit will be held. All offerors shall ensure registration is active, current, and accurate in SAM and includes NAICS code 541380 at the time of RFQ submission through award. Point of Contact: Eric Sweatt, Contract Specialist eric.sweatt@va.gov | - | Pre-Solicitation | 12/10/2026 |
This is a pre-solicitation notice only; do not respond. The Veterans Health Administration (VHA), Network Contracting Office (NCO) 10, requires Sterile Processing Service Water Testing Services for the Marion, Fort Wayne, and Jackie Walorski VA sites in Indiana. The Government intends to publish a 100% set-aside solicitation for Service-Disabled Veteran-Owned Small Businesses on or about 11/25/2026. The solicitation will require the Contractor to furnish a quote providing all information requested in the Instructions to Offerors for Testing Laboratories and Services. The applicable NAICS Code is 541380 Testing Laboratories and Services with a size standard of $19.0 Million. Responses will be evaluated using comparative evaluation under FAR Parts 12 and 13; see solicitation for specific criteria. The resulting award will be a Base with Four Option Years, Firm Fixed Price contract. The closing date for receipt of offers is 12/10/2026 at 01:30 PM ET. All solicitation documents may be downloaded on the date of issuance through Contracting Opportunities via Sam.gov. Any amendments will be posted only on this website. The offeror is responsible for verifying the number of amendments issued. Offerors will have an opportunity to ask questions; details will be provided in the posted solicitation. After the questioning period closes, the Government will post responses to all questions on SAM.gov via a solicitation amendment within 3 business days. Phone calls will not be accepted. No site visit will be held. All offerors shall ensure registration is active, current, and accurate in SAM and includes NAICS code 541380 at the time of RFQ submission through award. Point of Contact: Eric Sweatt, Contract Specialist eric.sweatt@va.gov | - | Pre-Solicitation | 12/10/2026 |
Contractor shall provide all labor, supplies, equipment, and supervision necessary to provide Wastewater Effluent Laboratory Analysis Services to the Aleda E. Lutz VA Medical Center described herein. Wastewater Effluent Laboratory Analysis Services include, but are not limited to sample preparation, collection, and storage; transportation of wastewater effluent samples to a laboratory, performance of analytical testing; reporting of analytical test results; and consultative services. | - | Solicitation | 11/06/2026 |
Additional Details
Solicitation Number
36C26026P0793
Archive Date
Sep 26, 2026
Office Address
VANCOUVER, WA, 98661