GovChime
Notice ID: ad1fdcad2aad4064914ad9b2ceec3557Sources SoughtArchived

C1DA--AE-NRM-687-26-100 Modernize Physical/Electronic Security Systems

Archived on December 10, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM PST
Posted
November 18, 2025
Notice type
Sources Sought
NAICS
541310: Architectural Services
Agency
Department of Veterans Affairs

Notice details

Office
260-NETWORK CONTRACT OFFICE 20 (36C260)
Place of performance
Department of Veterans Affairs Jonathan M. Wainwright Memorial VA Medical Center, Walla Walla, WA, 99362
Last updated
Nov 6, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C26026Q0148
Notice ID
ad1fdcad2aad4064914ad9b2ceec3557

Description

Sources Sought - Solicitation Number: 36C26026Q0148 Project 687-26-100 Modernize Physical and Electronic Security Systems This is a Sources Sought announcement only. This is not a request for proposals, quotations, or bids; nor a synopsis of a proposed contract action under FAR Subpart 5.2 and no contract shall be awarded from this notice. No reimbursement will be made for any costs associated with providing information in response to this Sources Sought or any follow-up information requests. No solicitation is currently available. Draft documents are subject to change. Attachments; Source Sought Questionnaire 687-26-100 Physical Security and Resiliency Design Manual AE SOW 687-26-100 SOW Attachment 01 - Required Div 01 Spec Sections SOW Attachment 02 - Sensitive Infrastructure Data Classification Memo SOW Attachment 03 - 01 32 16.01 EHRM A-E CPM Schedules SOW Attachment 04 - VAWW Campus Map SOW Attachment 05 - Fiber Optic Distribution Site Plan SOW Attachment 06 - Engineering Design Waiver Template SOW Attachment 07 - STN 687 PG-18-15, Volume C, A-E Submission Instructions SOW Attachment 08 FCA Report Redacted This notice is for market research purposes to gain knowledge of interest, capabilities, and qualifications of interested Small Business firms. Responses to this Sources Sought may shape the acquisition strategy in developing a competitive requirement. Not responding to this notice does not preclude participation in any future or potential solicitation. It is the intent of the VA to use the information gathered for market research purposes only. The Veterans Health Administration, Regional Procurement Office West, Network Contracting Office 20, is conducting market research for an Architect-Engineer (A-E) contract to modernize the physical and electronic security systems. PROJECT OVERVIEW High Level Scope of Work Site visits, field investigations, reports from investigations, studies, and user interviews to prepare drawings, specifications, and cost estimates for all facets of work and disciplines/trades to facilitate a construction project to replace the campus physical access control (PACS) and security surveillance systems (SSTV), inclusive of all equipment, programming, accessories, and infrastructure required for a fully functioning, modernized, fully integrated single network and software platform on the Walla Walla VAMC campus. Project will expand coverage of PACS and SSTV to close security vulnerabilities. All lock cores and, as necessary for compatibility with new cores and PACS equipment, door hardware shall be replaced throughout the domain of the Walla Walla VAMC. Additionally, lock cores, and door hardware where necessary to accommodate new lock cores, shall be replaced at Community Based Outpatient Clinics (CBOCs) and Primary Care Telehealth Outpatient Clinics (PTOC) located in Union Gap, WA; La Grande, OR; and Boardman, OR. Aged, failing, and incompatible surveillance cameras will be replaced. Design Discipline Requirements Architectural To assess if the door frame and door hardware is able to support the installation of electronic security devices for PACS hardware. Electrical To assess if there is enough available power within each of the buildings to support the systems. Physical Security For electronic systems and site risk assessment the following certifications are required: CPP or PSP from ASIS (American Society Industrial Security) is required. Certified Protection Professional (CPP) For facility risk determination to inform what areas of the medical center will require certain levels of security equipment. Physical Security Professional (PSP) or Certified System Integrator (CSI), Certified Fire Alarm Designer (CFAD), and Certified Service Technician (CST) Required for systems integration and management of IT security strategies. Global Industrial Cyber Security Professional (GISCP) or Certified Information Systems Security Professional (CISSP) Needed for network and security design for the security hardware. Registered Communications Distribution Designer (RCDD) Required for telecommunications design. ** See the attached Physical Security and Resiliency Design Manual (Rev 06-01-2025): Section 2.1.2 Requirements for a Certified Physical Security Specialist (Page 2-2) Annex to Chapter 10 - A-10.1 through A-10.1.5 (Page 10-36) PROJECT LOCATION Work is located at Jonathan M. Wainwright Memorial VA Medical Center- Walla Walla, WA 99362. For the principal components of work, see the attached draft statement of work and supporting documents. Documents are currently in draft state and industry comment / suggestions are greatly encouraged and welcomed. The estimated magnitude for this project is between $5,000,000 and $10,000,000 NAICS AND SIZE STANDARD Sources are being sought for firms with a North American Industry Classification System (NAICS) code of 541310 Architectural Services, a Product Service Code (PSC) of C1DA and a Small Business Size Standard of $12.5 million. Sources are highly encouraged to respond to this notice. RESPONSE REQUIREMENTS Responses are requested with the following information and shall not exceed a total of 2 (two) pages. Email subject line needs to contain the solicitation number 36C26026Q0148. Please provide the following information: Contact information: Name, address, SAM.gov UEI number, and points of contact with telephone numbers and e-mail addresses. Business Size/Classification (based on NAICS 541310): Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program. [ ] yes [ ] no Small Business (SB) [ ] yes [ ] no HUBZone [ ] yes [ ] no Small Business 8(a) [ ] yes [ ] no Small Disadvantaged Business (SDB) [ ] yes [ ] no Women-Owned (WO) Small Business [ ] yes [ ] no Service-Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Other (please specify) Capabilities Statement: Description of capabilities to perform A/E design services as described above and project experience demonstrating relevant experience similar to those described. Please specifically address how your firm meets the requirements outlined in the Project Overview section, including the required design discipline capabilities and certifications. Govt. does not have a waiver to Buy American. SDVOSB or VOSB businesses please include statement on maintaining compliance with VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction. All other socio-economic businesses please include statement on maintaining compliance with FAR 52.219-14 Limitations on Subcontracting. Time: Based on the information provided, please estimate the total project time in days. Past Performance/experience: Provide information on contracts of similar scopes of work or construction contracts, briefly describe no more than three (3) contracts (or specific task orders) completed within the past five years of the issue date of this Sources Sought notice. The past performance information should include: Project Title/Contract Number Location: City, State General description of the A-E to demonstrate relevance to the proposed project Offerors role Dollar value of contract Name of the company, agency, or government entity for which the work was performed What types of information is required to submit accurate offers? If submitting past performance/experience on a project in the role of a subcontractor, include the Prime Contractor s name and a quantifiable amount (percentage) of the project your company contributed to the overall scope of work. Note: Do not include Proprietary, classified, confidential, or sensitive information in responses. NO RESPONSES WILL BE ACCEPTED BY FAX. Responses will not be returned. Telephonic responses will not be honored. Please respond by email only. Send responses to the Contract Specialist, Sangmi Kim at Sangmi.Kim@va.gov. Responses will be accepted until November 25, 2025, 3:00 PM Pacific Time.

Full description on SAM.gov

Award Overview

Possible prior contract

Inferred, not confirmed

Inferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.

Contract end date

Feb 25, 2027

NAICS

541310

Agency

Department of Veterans Affairs

Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.

Contacts

Contracting Officer

Primary Contact

Sangmi Kim
Contract Specialist

Documents

Files (12)

  • SOW Attachment 08 - FCA Report Redacted.pdf

    5.7 MBAdded in Sources Sought version 3Posted
    Download
  • SOW Attachment 07 - STN 687 PG-18-15 Volume C A-E Submission Instructions.pdf

    850 KBAdded in Sources Sought version 3Posted
    Download
  • SOW Attachment 06 - Engineering Deviation Request Template.docx

    48 KBAdded in Sources Sought version 3Posted
    Download
  • SOW Attachment 05 - Fiber Optic Distribution Site Plan.pdf

    9.3 MBAdded in Sources Sought version 3Posted
    Download
  • SOW Attachment 04 - VAWW Campus Map.pdf

    733 KBAdded in Sources Sought version 3Posted
    Download
  • SOW Attachment 03 - 01 32 1601 A-E CPM Schedules.pdf

    111 KBAdded in Sources Sought version 3Posted
    Download
  • SOW Attachment 02 - Sensitive Infrastructure Data Classification Memo.pdf

    492 KBAdded in Sources Sought version 3Posted
    Download
  • SOW Attachment 01 - Required Div 01 Spec Sections.pdf

    688 KBAdded in Sources Sought version 3Posted
    Download
  • AE SOW 687-26-100.pdf

    1.4 MBAdded in Sources Sought version 3Posted
    Download
  • Physical Security and Resiliency Design Manual.pdf

    4.3 MBAdded in Sources Sought version 3Posted
    Download
  • Sources Sought Questionnaire 687-26-100.docx

    14 KBAdded in Sources Sought version 3Posted
    Download
  • 36C26026Q0148.docx

    36 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    C1DA--AE-NRM-687-26-100 Modernize Physical/Electronic Security Systems

    Notice ad1fdcad2aad4064914ad9b2ceec3557 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Pre-solicitation Notice #36C25526R0182 for project 657-27-210JB, A/E-Repair RRTP for Restrooms in Building 3 and 51.
78%
Pre-Solicitation10/05/2026
Please be advised that the submission deadline for SF 330 has been extended from November 13, 2026, to November 20, 2026, at 2:00 PM EST. Responses to the RFIs are currently being prepared and will be posted prior to the revised due date.
72%
Market Research11/20/2026
Modification 2 to Presolicitation Notice 36C25527R0007, P/N 657-27-209JB, Project Title: Renovate Building 1 and 53 Main Lobbies. This modification provides answers to RFIs received, revised evaluation criteria and revised supplement B per below RFIs. The SF330 submission due date is extended from November 10, 2026 to November 16, 2026. RFIs Received with VA Responses in blue text: Construction Budget questions: Is that the Estimated Cost of Construction or the maximum for the A/E Design Fee? Estimated Cost of Construction If the $949,026 is the construction budget, this appears low in today's environment given that over 6,000 SF needs to be renovated. Can the VA please re-evaluate this budget and provide an update? The construction budget that was originally used in the supplement B pre-solicitation notice is incorrect. A revised supplement B is attached, changing the construction cost estimate from $949,026 to $725,873. The Construction budget is set and cannot be changed until the design process is underway. Key Personnel questions: The Presolicitation Notice lists: Supervisory, Fire Protection Engineer, Certified Professional Industrial Hygienist, and Life Safety Engineer. The Statement of Work and Supplement B list: Communications (voice/data), Interior Design, VPIH, Plumbing (including fire protection), and a 3rd Party Fire Protection Review. Questions: Which positions require resumes in Section E? What is the intended role of "Supervisory"? Per the SOW & Supplement B the following positions require resumes: Project Manager, Architectural, Mechanical, Electrical, Communication (voice data) Plumbing (Including Fire Protection), Structural, Interior Design, VPIH, Cost Estimator and a 3rd Party Fire Protection Review. Project manager is Supervisory Industrial Hygienist/Asbeston Project Designer: Question: Is an ABIH Certified Industrial Hygienist (CIH) acceptable for this position, and does a CIH satisfy the requirement for the VPIH and the state-accredited Asbestos Project Designer? If these must be separate individuals, should both be identified in the SF330? A CIH satisfies the requirement for the VPIH and the state-accredited Asbestos Project Designer. They can be the same individual. Site Visit: Supplement B, page 6, Section III.6.g: the A/E "shall meet with the COR at the proposed project site" prior to submitting a response Presolicitation Notice, page 4: "Personal visits to discuss this announcement will not be allowed" and only "the most highly rated firm must physically come to the site" before pricing Question: Please confirm that no site visit is required before the SF330 submission. No site visit is required prior to SF330 submission. Laboratory and Special Room Rquirements: Presolicitation Notice, page 7, Evaluation Criteria 2, Specialized Experience and Technical Competence: "laboratory requirements for the firm" Supplement B, page 18, Section B6.II.1: "floor plans of special rooms such as the endoscopy suite, recovery room, etc." Questions: Neither a laboratory nor an endoscopy suite or recovery room appears in the project scope. Do any of these requirements apply to this project? These requirements do not apply to this project. Can the VA please release updated and corrected documents? The evaluation criteria 2 will be changed to remove laboratory requirements for the firm and the COR will revise Supplement B to remove the endoscopy suite and recovery room from the Supplement B.
71%
Pre-Solicitation11/16/2026
NOTICE OF INTENT TO SOLE SOURCE The Department of Veterans Affairs, Network Contracting Office (NCO) 17, intends to award a sole source, Firm-Fixed-Price (FFP) contract to Cox Design Associates, Inc., a certified Service-Disabled Veteran-Owned Small Business (SDVOSB). The requirement is to provide Architect/Engineer (A/E) Construction Period Services (CPS) for Project 674 19 101, Replace Boilers and Boiler Plant, located at the Temple VA Medical Center, 1901 Veterans Memorial Drive, Temple, TX 76504. The applicable NAICS code is 541310 Architectural Services, with a size standard of $12.5M. Cox Design Associates, Inc. previously completed the 100% design and construction documents for this project under a separate A/E contract. Construction is active, and the VA now requires continued CPS throughout the remaining construction period to ensure proper interpretation, adjustment, and execution of the original design intent. The required CPS includes but is not limited to: Construction submittal reviews; Responses to Requests for Information (RFIs); Preparation of supplemental instructions and design clarifications; Review of potential change orders; Attendance at site visits and weekly construction meetings; Oversight ensuring the Designer of Record (DOR) design is executed accurately. Cox Design Associates, Inc. possesses unique design knowledge and remains the Designer of Record (DOR). Any firm proposing to take over CPS responsibilities must demonstrate in writing how it would effectively and efficiently assume full responsibility for interpreting and administering another firm s design, including: Detailed knowledge of the design rationale, engineering decisions, and analysis, Ability to perform CPS within the same technical footprint as the DOR, Willingness to assume full liability for design interpretation, corrections, or changes that may arise during construction. Any prospective A/E firm asserting capability to meet this requirement may give a written notification to the Contracting Officer in the form of a capability statement, including an explanation of how the contractor would be able to effectively and efficiently operate in the same footprint as the A/E DOR. This procurement will be conducted under the authority of 41 USC §3304(a)(5), 38 U.S. Code § 8127(c), as implemented by RFO 6.103-5 (Authorized or Required by Statute). The requirement will be awarded using the non-competitive (sole-source) procedures authorized in VAAR 819.7008 (DEVIATION) for sole-source awards to certified SDVOSBs up to $5,000,000. A Justification & Approval (J&A) will be posted after award in accordance with FAR 6.301. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. No responses to this notice are requested. No solicitation will be issued. If a firm believes VA should not proceed with this sole-source action, it may submit a capability statement by 10:00 AM (Central Time), October 14, 2026, to: Ms. Makarim.Abdul Jabbar@va.gov Contracting Officer, NCO 17 Telephone inquiries will not be accepted. The VA will NOT reimburse any costs associated with responding to this notice. Information received will be used solely to determine whether a competitive procurement is appropriate. A determination not to compete the proposed contract will be made at the sole discretion of the Government.
71%
Pre-Solicitation10/14/2026
AMENDMENT A0001 Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice REQUEST FOR SF 330 36C25227Q0013 Project 578-27-003: Renovate A Section 1st Floor Bldg. 1 (AE) Design/Engineering Services SF-330 Package Due: October 30, 2026, at 1:00 p.m. CST (see details below) Points of Contact: Donita.Grace@va.gov INTRODUCTION: THIS IS A TOTAL 100% SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS (SDVOSB) SET-ASIDE in accordance with Public Law 109-461. This is a Request for SF330s for Architect/Engineer (A/E) Design Services for Project Number 578-27-003: Renovate A Section 1st Floor Bldg. 1 (AE) at the Edward J. Hines VA Hospital in Hines, IL. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL. NO SOLICITATION PACKAGE WILL BE ISSUED via SAM.gov. A request for proposal will be issued directly to the top-rated firm for which negotiations will commence in accordance with FAR part 36. The anticipated A/E design services, to be awarded, will be procured in accordance with the Selection of Architects and Engineers Act (Public Law 92- 582), FAR Part 36.6 and VA Acquisition Regulation 836.6. Period of Performance: 449 Calendar Days Contract Type: Firm-Fixed-Price Estimated Magnitude of Construction: Between $10,000,000 and $20,000,000 NAICS Code: 541310 Size Standard: $12.5 Million SBA & SAM : in accordance with VAAR 819.7003, at the time of SF330 submission and prior to award of any contract, the offeror must represent to the contracting officer that it is a (1) SDVOSB eligible firm; (2) Small business concern under the North American Industry Classification System (NAICS) code assigned to the acquisition; and (3) SDVOSB listed as verified in SBA at: https://veterans.certify.sba.gov/ Additionally, all eligible firms must be registered and current in the System for Award Management (SAM) database to be evaluated and eligible for contract award. If the firm is not registered in SAM, you may register online at https://www.sam.gov. 1. PURPOSE: This Source Selection Plan (SSP) outlines the procedures that will be used to solicit architectural and engineering (AE) design services for Project 578-27-003 Renovate A Section on First Floor of Building 1. The goal of this project is to provide complete AE design services to renovate section A of the 1st floor of building 1. 2. ACQUISISTION DESCRIPTION: 2.1: RFI: A Request for Information shall be published to https://sam.gov whereby interested architect-engineering companies shall submit an SF330 package. This competitive procurement shall utilize a best value trade-off source selection process identified in FAR 15. 2.1.a: Source Selection Evaluation Board (SSEB): For the purpose of this acquisition, the SSEB will be same as the Technical Evaluation Board (TEB). 2.1.b: Below are the individual (TEB) evaluation criteria and ratings for the SF330s, listed in descending order of importance. FACTOR 1: SPECIALIZED EXPERIENCE AND TECHNICAL COMPETENCE (30 Maximum Points) Subfactor 1A: Specialized Experience (15 Points). Subfactor 1B: Additional Experience (10 points). Subfactor 1C: Technical Competence (5 points). The A/E Firm shall demonstrate its specialized experience and technical competence in the design and construction period services for projects of similar size and complexity. Specialized project experience should include design of renovations to existing hospitals, renovations to buildings constructed prior to 1970 w/space constraints, design of Pathology Suites, and HVAC upgrades to existing hospitals. Additional experience includes mechanical, electrical, and structural engineering, architecture, interior design and finishes, physical security upgrades, building management systems/building automation systems (BMS/BAS), Computer-Aided Design and Drafting (CADD), critical path scheduling, fire protection, construction infection control protocols, design and installation of biological refrigeration and preservation systems, design and installation of vacuum tube transport systems, and project phasing and coordination in an active hospital setting. Offeror shall provide a minimum of three (3), and no more than five (5) recent and relevant Government and private experience projects similar in size, scope, and complexity, and experience with the type of projects/competence above. Relevant is defined as those task requirements identified in the Statement of Work. Recent is defined as services provided within the past seven (7) years with at least 50% of the Construction completed. At a minimum, include the following for each submitted project (if applicable): Project title, location, contract number, and detailed narrative describing the scope of services provided including the type of work performed by the offeror and its role in the project i.e., prime contract, Teaming Partner, or subcontractor. Project Owner, owner s point of contact including telephone number and email address. Services & Deliverables provided under the contract/task order Period of Performance, including start and completion dates for design and construction if applicable. Estimated cost of construction based on AE s design Final construction cost (or projected final construction cost if still underway) The percentage of total cost resulting from changes due to AE omissions. To demonstrate technical competence, the offeror shall include narratives of how the firm addresses each of the following topics. Simply restating this list will not be sufficient. The management approach The coordination of disciplines and subcontractors Quality control procedures Familiarity with VA Design Guides/Manuals, Master Specifications and other applicable standards. FACTOR 2: PROFESSIONAL QUALIFICATIONS (20 Maximum Points) Subfactor 2A: Key Positions (15 Points). Subfactor 2B: SDVOSB Compliance (5 Points). The architects and engineers on the firm s staff representing the project or signing/stamping drawings in each discipline must possess a minimum of five (5) years of experience and are required to be licensed, registered, or certified by a U.S. state, the District of Columbia, or a U.S. territory. Provide professional license jurisdiction of issue and license numbers and/or proof of licensure. A resume for each of these key positions must be provided, corresponding with the title matching the disciplines listed for the project. At a minimum, the offeror must describe the professional qualifications and specific experience in the required disciplines within the past five (5) years. Key positions and disciplines required for this project include, but are not limited to: Project Manager Architect Mechanical Engineer Electrical Engineer Plumbing Engineer Structural Engineer Interior Designer The evaluation will consider education, certifications, training, registration, overall and relevant experience and longevity with the firm. Offer must include the following statement of SDVOSB compliance when submitting the personnel proposed to perform the work under this requirement: I [signatory authority] ______________________, [company] _____________________; certify that the team proposed to perform under this requirement demonstrates the capability of 50% SDVOSB performance in compliance of 48 CFR 852.219-10. FACTOR 3: PAST PERFORMANCE (20 Maximum Points) Subfactor 3A: Past Performance of projects identified in FACTOR 1. (15 Points). Subfactor 3B: Average Past Performance of all projects (5 Points). Provide CPARS data for all projects identified in FACTOR 1. For any project that does NOT have CPARS data available, a Past Performance Questionnaire (PPQ) is required to be submitted with the SF330. Please utilize the attached PPQ document. CPARS data and PPQs will not be included in the page count. All projects provided in the SF330 must be completed by the office/ branch/ individual team member performing the work under this contract. The following information must be clearly specified on each performance report: Contract/task order number Project title Prime firm Start date Completion date Offers shall only include CPARS data for the projects listed in FACTOR 1. The contracting officer shall directly retrieve CPARS reviews from www.CPARS.gov to determine average past performance of previous projects. Government Past Performance Information Systems may be accessed. Evaluating past performance and experience may include information provided by the firm, customer inquiries, Government databases, publicly available sources, and additional projects in CPARS. Failure to provide requested data, accessible points of contact or valid phone numbers could result in a firm being considered less qualified. FACTOR 4: QUALITY CONTROL (10 Maximum Points) Subfactor 4A: Management approach (5 Points). Subfactor 4B: Quality methodology (5 Points). The A/E Firm shall describe its management approach, regarding coordination of disciplines and subcontractors, familiarity of the prime firm and any key subcontractors with VA Design Guides/Manuals, Master Specifications, ASHRAE standards, NEC, and other applicable standards. A/E Firm shall also provide the following: Quality Control organization, and management structure. Methods and procedures for control and prevention of nonconformances during design, preconstruction, and construction. Methods and procedures for nonconformance remediation at all stages of project. Methods and procedures for control and prevention of cost, and schedule overruns. Summarized schedules for selected three previous design projects that show initial approved project schedule, and any updates to schedule with time extensions. Provide a narrative to describe reasons and justifications for any deviations from initial schedule. Summarized cost estimates for selected three previous design projects that show initial approved total project cost estimate, and any increases to initial cost estimates. Provide a narrative to describe reasons and justifications for any deviations from initial estimates. Describe any unforeseen conditions that arose during construction for your last three projects. Provide a narrative to describe how your firm assisted the project management team to correct those deficiencies, and any methods used to mitigate extra costs and increases in project schedule. FACTOR 5: CAPACITY (10 Maximum Points) Subfactor 5A: Capacity to complete work within required timeline (5 Points). Subfactor 5B: Resource management and project management (5 Points). The A/E Firm shall attest to its capacity to accomplish the work in the required time. The evaluation will consider the firm s ability to meet the schedule of the overall project, as well as the available capacity of personnel in key disciplines. The A/E Firm shall also provide the following: A list that shows the total number of design and project professionals who are currently employed at the firm with professional titles for each. Total number of projects in study or planning stages Total number of active design projects Total number of active construction phase services A list of personnel assigned to each of the above projects An analysis and report of available capacity of key personnel for immediate new work The respondent shall: Summarize its approach to staffing and company resource management For the key personnel on the proposed project team, tabulate their current and projected workload as percentages of their available individual capacity. List all work awarded to the A/E Firm by the VA during the previous 12 months, as well as any current indefinite delivery, indefinite quantity (IDIQ) contracts that it has. List the current stage and percentage of completion for non-IDIQ projects. A signed statement shall be provided stating that the firm acknowledges that prior to award of the contract, it is required to notify the Government of any changes in its capacity that could limit its ability to perform the work within the required time. FACTOR 6: GEOGRAPHIC LOCATION (5 Maximum Points) Location of the firm, as measured by the travel time (hours) between the Offeror s principal business location and Edward Hines, Jr. VAMC, Hines, IL. Architect must provide details of travel between their main office and Edward Hines Jr, VAMC Hines, IL. This includes but not limited to airport travel time, driving distance, etc. If the architect has a satellite location, the architect must provide details of a fully staffed and well-established satellite office. Leasing documentation may be requested. FACTOR 7: EXPERIENCE IN CONSTRUCTION PERIOD SERVICES (5 Maximum Points) The A/E Firm shall demonstrate its experience in providing Construction Period Services for hospital facilities, particularly in HVAC renovation projects. The respondent shall provide a narrative that describes the methods and procedures used to implement each of the following Construction Period Services tasks: Professional field inspections during the construction period, with descriptions of types of inspections provided, and methods used for inspections and reporting during each phase of construction Review of construction submittals Support in answering requests for information during the construction period Support of construction contract changes to include updated drawings, drafting statements of work, and cost estimates. Weekly construction meeting participation Closeout documents to include final inspections and as-recorded drawings. SECONDARY SELECTION CRITERION*: FACTOR 8: CLAIMS (-5 to 0 Maximum Points) Subfactor 8: Record of significant claims against the firm because of improper or incomplete architectural and engineering services. (-5 to 0 Points). * The secondary selection criterion is used as a tiebreaker, if necessary, in ranking the most highly qualified firms following the completion of discussions. The secondary selection criterion will not be applied when determining a firm s SF330 submission. 2.1.c: After TEB Individual Ratings of the SF330s are completed, the TEB shall convene and develop consensus ratings for the seven evaluation factors of the SF330s as defined above. COMMENT DESCRIPTION DEFINITIONS Strong point: Provides Merit/advantages to VA that increase the likelihood of successful contract performance. Weak point: Flaws/disadvantages that increase the likelihood of unsuccessful contract performance. 2.2.c: The eighth factor (Secondary Selection Criterion) will only be used if needed. The TEB shall provide a listing, in order of preference, of the firms considered most highly qualified to perform the work. The contracting officer shall issue a Request for Proposal (RFP) to the architect-engineer the TEB recommends for negotiations. 3. SOURCE SELECTION PROCESS: 3.1 SF330 Reviews: The board will review and evaluate the submitted SF330 s in accordance with the stated evaluation criteria to determine each individual offeror s ability and capability to perform the work required and confirmation of determination of responsibility per FAR 9.1. a) TECHNICAL EVALUATION BOARD SF330 INDIVIDUAL EVALUATIONS (1) Each board member will conduct an independent review and evaluation and complete an evaluation rating sheet for EACH SF330. Each category will be addressed with strengths or weaknesses noted. (2) The evaluation will be in accordance with the Evaluation Factors which are listed in the solicitation. b) TECHNICAL EVALUATION BOARD SF330 CONSENSUS (1) After each member has completed their independent evaluation, the Chairperson will discuss the evaluations with the entire team and assure each evaluation is complete. (2) During these discussions, the board will reach a consensus rating for each SF330 and document ratings using the consensus evaluation worksheets. The SF330 can be downloaded through the GSA Forms Library at: https://www.gsa.gov/forms-library/architect-engineer-qualifications. No Fax Responses will be accepted: personal visits for discussing this announcement will not be entertained or scheduled. Questions may be directed only by e-mail to Donita.Grace@va.gov. VA Primary Point of Contact: Donita Grace, NCO 12 Contract Specialist, Donita.Grace@va.gov. The page limit for SF330 s will be 30 pages max., any pages after 30 will not be considered. See attached document: P01 - SOW 578-27-003 Renovate A Section 1st Floor Bldg. 1
70%
Combined Synopsis11/16/2026

Additional Details

Solicitation Number

36C26026Q0148

Archive Date

Dec 10, 2025

Place of Performance Country

United States

Office Address

VANCOUVER, WA, 98661