Scope of Work 1.0 General Intent 1.1 The contractor must provide up to 15 personnel with, equipment, tools, materials, supervision, and other items and services necessary to provide (4) day AC&R/Boiler/Hot Water Heater Maintenance training located at Bldg. 6 located at 3801 Miranda Ave. Palo Alto, CA 94304. 1.2 The contractor must perform to the standards in this contract. This project shall take no longer than 15 calendar days from the notice to proceed to complete. 1.3 This project shall be coordinated with the appointed COR to insure minimal impact to resident s day to day activities and minimal noise. Scheduling of work shall be at the convenience of the VAPAHCS. 2.0 General Information and Requirements 2.1 The objective of this project is to provide to provide (4) day AC&R/Boiler/Hot Water heater Maintenance training located at Bldg. 6 located at 3801 Miranda Ave. Palo Alto, CA 94304. 2.2 The contractor shall provide operation and maintenance instructions, and manufacturer documentation at the completion of the project. Manufacturer documentation and maintenance schedule to be provided in close out documents. 2.3 The contractor shall provide all tools, equipment, and personal protective equipment necessary to complete this project as deemed by industry standards, this SOW, all related specifications, applicable code requirements, and site policy. 2.4 The contractor shall provide daily cleanup and securing of work site, including securing tools and equipment. Disposal of all waste and debris is at the contractor s own expense. 2.5 The contractor shall provide quality control of all work conducted and the individual appointed shall be competent and educated/experienced in the field of work this scope encompasses. 2.6 All work shall be coordinated with the COR assigned to this project and only commence once approved. 2.7 Badges: Contractor will obtain required ID badges for all employees used on project at start of each workday; Report the COR for escort to the station police service for sign in and badge issuance. 2.8 Security: The contractor and their personnel shall be subject to the same Federal laws, regulations, standards, and VA policies as VA personnel regarding information and information system security. 2.9 Schedule: Normal work hours will be 8:00am 4:30 pm Monday-Friday excluding Government holidays unless otherwise approved by the COR. It is the intent of the Palo Alto VA Medical Center that the work is to be completed within 15 calendar days from the issuance of the Notice to Proceed (NTP). Any request to utility shutdowns must be requested in writing at a minimum of 21 days prior to the requested day of shutdown. 2.10 Codes and Standards: The Contractor shall follow all applicable codes and standards to this type of work including but not limited to Health Care System Memorandums (HCSM), OSHA Guidelines, Lock-out-Tag-out, Rules of Station, NFPA, and etcetera. If any code/standard is found to be contradictory; the authority having jurisdiction (COR) shall make the final determination and work shall proceed at no additional cost to the Government. 3.0 Specific Tasks 3.1 The contractor shall provide all supervision, administrative and technical support, labor, subcontractors, tools, transportation, materials, supplies and equipment. The contractor shall plan, schedule, and ensure effective completion of (4) day course for Basic Electricity and Electrical Troubleshooting and Maintenance for up to 15 people. 3.2 The contractor will supply (2) training that will consist of the following: Boiler/ Hot Water Heater Operation, Maintenance, & Safety Course Description This Boiler/ Hot Water Heater Operation, Maintenance, & Safety training seminar was designed to take the mystery out of wondering if your boiler is safe and operating efficiently, and provides maintenance technicians and others the confidence and comfort level needed for operating and maintaining their boilers. for the novice technician needing a well-rounded education and the experienced stationary engineer who needs a refresher course for continuing education, this training program provides a no-nonsense, practical and real world approach for boiler/ Hot water heaters. operation, maintenance, and safety. Overall, this program is designed to extend boiler life, improve boiler efficiency, and save energy costs for the employer, while establishing a culture of safe work practices among the employees. CEUs: 1.6 Length: 2-Days Workshop Option This course can be combined with our Air Conditioning & Refrigeration for a complete 4-Day workshop. Air Conditioning & Refrigeration Course Description Being able to understand, operate, maintain, and troubleshoot your own air conditioning system is what this HVAC course is all about. It was created to bring students up to speed in their skills and knowledge as quickly and safely as possible. Taught by instructors who have been in the technicians shoes, the practical, commonsense approach we take in presenting this course makes it perfect for novice technicians and experienced HVAC technicians alike. This air conditioning and refrigeration training course is designed for anyone who needs to understand basic operation, maintenance, and troubleshooting of air conditioning and refrigeration systems in order to improve efficiencies and uptime in commercial, industrial, or residential locations. CEUs: 1.6 Length: 2-Days Workshop Option This course can be combined with our Basic Electricity for the Non-Electrician for a complete 4-Day workshop.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C26122Q0210
  1. Pre-Solicitation
  2. Combined Synopsis
  1. Pre-SolicitationJan 14, 2022

    J041--AC-R and Boiler Training (VA-22-00025211)

    Notice 09eefc12b53248ea9bca1f5f64f67d7e on SAM.gov

  2. 2×
    Combined SynopsisCurrentJan 19, 2022

    J041--AC-R and Boiler Training for VAPAHCS Personnel IAW the revised Statement of Work

    Notice f9d87c9e4828488186a5610a778a95f8 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
2nd Floor HVAC Repairs VA Central California Healthcare System
76%
Market Research11/04/2026
Sources sought Notice Only. HVAC Maintenance and repair services at Miramar National Cemetery. -- J041 Sources sought Notice Only. HVAC Maintenance and repair services at Miramar National Cemetery. Sources sought Notice Only. HVAC Maintenance and repair services at Miramar National Cemetery. Please e-mail capability statement, SAM.gov UEI number, and estimated Sub-Contract % to Daniel.Jolly1@va.gov no later than 04-15-2026. Miramar National Cemetery 5795 Nobel Drive San Diego, CA, 92122
74%
Market Research04/14/2026
Sources Sought Notice only. HVAC Maintenance and repair services at the Fort Rosecrans National Cemetery. -- J041 Sources Sought Notice only. HVAC Maintenance and repair services at the Fort Rosecrans National Cemetery. Sources Sought Notice only. HVAC Maintenance and repair services at the Fort Rosecrans National Cemetery. FT. ROSECRANS NATIONAL CEMETERY 1700 Cabrillo Memorial Dr San Diego, CA 92106 Please e-mail your Capability Statement, Estimated Sub-Contract %, along with SAM.gov UEI number to: Daniel.Jolly1@va.gov NO LATER THAN 04/15/2026.
74%
Market Research04/14/2026
This is a SOURCES SOUGHT NOTICE ONLY This SOURCE SOUGHT NOTICE is for the purpose of Market Research. Response to this notice will be used for information and planning purposes. No proposals or quotes are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS or QUOTES and NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall NOT be construed as solicitation or as an obligation on the part of the Department of Veterans Affairs (VA). Responses to this notice is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. The Network Contracting Office (NCO) 16 is seeking Businesses capable of providing the HVAC Repair on Daikin VRF Heat Recovery Unit, as per the draft Statement of Work below See DRAFT Statement of Work for detailed description. The NAICS code is 238220, Plumbing, Heating & Air Conditioning Contractors, and the Size Standard is $16.5M. Responses must be received by no later than 12:00 p.m. Central Time, Wednesday, November 4, 2026. Responses shall be emailed to angela.kennedy2@va.gov Response shall contain Capabilities Statements to include Unique Entity Identification (UEI) number, and any qualifying certifications that may be required. Response MUST include letter of authorization from the original equipment manufacturer, Daiken, to perform the work. Facsimile or Telephonic responses will not be accepted. Note: All interested parties are reminded to be registered, active and verified in the following to be considered for Award. SAM: SAM.gov | Home SBA https://search.certifications.sba.gov/ Vet 4212 (Veteran owned small Business are reminded of Reporting Requirements) VETS-4212 Federal Contractor Reporting | U.S. Department of Labor (dol.gov)
73%
Market Research11/04/2026
AHU Pictures and Answers
73%
Combined Synopsis09/22/2026

Additional Details

Solicitation Number

36C26122Q0210

Archive Date

Feb 7, 2022

Office Address

MATHER, CA, 95655