GovChime
Notice ID: de4e0ff950ca41dfa17d0274926d8381Award NoticeAwardedArchived

6515--Digital Transcutaneous Blood Gas Monitoring System

Awarded on March 3, 2026. Full description on SAM.gov.

Awarded tounder 36C26126P0495 (source: SAM.gov award notice)• $39.2K

Overview

Posted
March 4, 2026
Notice type
Award Notice
NAICS
334510: Electromedical and Electrotherapeutic Apparatus Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
261-NETWORK CONTRACT OFFICE 21 (36C261)
Place of performance
Department of Veterans Affairs VA Sierra Pacific Network (VISN 21), Mather, CA, 95655
Last updated
Nov 3, 2026
First published
Last updated on SAM.gov
Award date
Mar 3, 2026
Award amount (SAM.gov award notice)
$39.2K

Identifiers

Solicitation number
36C26126Q0289
Notice ID
de4e0ff950ca41dfa17d0274926d8381
Award number (PIID)
36C26126P0495

Description

Solicitation No: 36C26126Q0289 Posted to SAM.gov: 02/24/2026 Awardee: SENTEC, INC. (JCYVNVQZ2RX4) 40 Albion Road, Suite 100 Lincoln, Rhode Island 02865-3707 United States Total Number of Quotes Received: One (1) Evaluation Total Amount: $39,186.87 Period of Performance: 03/03/2026 06/01/2026

Full description on SAM.gov

Award Overview

Award Number

36C26126P0495

Award Amount (SAM.gov award notice)

$39.2K

Award Date

Mar 3, 2026

Awardee

Awardee UEI

JCYVNVQZ2RX4

Awardee CAGE Code

86Z83

Awardee Address

LINCOLN, RI 02865, RI

Original Solicitation

Notice ID: de4e0ff950ca41dfa17d0274926d8381

Posted Date: Mar 4, 2026

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

4
  • 36C24426P0488
    SENTEC, INC.
    Department of Veterans AffairsNAICS 334510
    $43.2KSigned Sep 11, 2026
  • 36C24826P0941
    SENTEC, INC.
    Department of Veterans AffairsNAICS 334510
    $21.3KSigned Jun 23, 2026
  • 36C26225P2226
    SENTEC, INC.
    Department of Veterans AffairsNAICS 334510
    $39.2KSigned Sep 19, 2025
  • 36C25025P1331
    SENTEC, INC.
    Department of Veterans AffairsNAICS 334510
    $16.6KSigned Jul 10, 2025

Contacts

Contracting Officer

Primary Contact

Tawnya Krommenhoek
Contracting Officer

Documents

Files (3)

  • SSJ Digital Transcutaneous Blood Gas Monitoring System_Redacted.pdf

    1.2 MBAdded in Solicitation version 7Posted
    Download
  • 36C26126P0495_1.docx

    23 KBAdded in Award Notice version 5Posted
    Download
  • 36C26126Q0289_2.docx

    96 KBAdded in Solicitation version 2Posted
    Download

Lifecycle

  1. 3
    Version 3SolicitationArchived

    6515--Brand-Name or Equal: Digital Transcutaneous Blood Gas Monitoring System Notice of Intent to Sole Source

    Notice b57afe3642f24472a2052362fc90407b on SAM.gov

  2. 5
    Version 5Award NoticeArchivedCurrent

    Type changed from Solicitation to Award Notice

    6515--Digital Transcutaneous Blood Gas Monitoring System

    Notice de4e0ff950ca41dfa17d0274926d8381 on SAM.gov

Other notices for this solicitation

  1. Market ResearchRelated noticeDec 23, 2025

    6515--Brand-Name or Equal: SENTEC tCOM+ Hospital Monitor with V-Sign Sensor 2

    Notice 1400342b2e344a3397338910f1fd23ca on SAM.gov

  2. Pre-SolicitationRelated noticeFeb 23, 2026

    6515--Brand-Name or Equal: Digital Transcutaneous Blood Gas Monitoring System Notice of Intent to Sole Source

    Notice 7db13c4d7a83456cb2732bb1f72b081d on SAM.gov

  3. SolicitationRelated noticeFeb 24, 2026

    6515--Brand-Name or Equal: Digital Transcutaneous Blood Gas Monitoring System Notice of Intent to Sole Source

    Notice 363e36d7fde6473b89bf6764306e78af on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing. Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The purpose of this procurement is to acquire autonomous healthcare delivery robot system for interior use at the VA Long Beach Healthcare System Pharmacy (VALBHS). 1. Functional and Performance Requirements The system shall autonomously transport and deliver critical Pharmacy medical supplies, pharmacy orders, and similar healthcare items within interior areas of VA Long Beach without continuous human teleoperation during normal operation. The system shall employ self driving obstacle avoidance technology that uses at least two sensing modalities from among 3D vision, eye safe laser ranging, and sonar (or functionally equivalent technologies) to map and navigate the facility while avoiding people and obstacles in a dynamic hospital environment. The robot shall be capable of continuous transport operations at a nominal walking pace appropriate for safe operation among staff and patients (approximately 2 4 miles per hour), with the ability to adjust speed as needed to comply with VA safety policies. 2. Payload and Capacity The robot shall provide at least one lockable, top loading cargo compartment designed for interior healthcare use. The primary cargo compartment shall have a total internal volume of at least 41 liters (approximately 11 gallons). The cargo compartment shall support a minimum payload of 50 pounds of medical items (e.g., linens, infusion pumps, towels, pharmacy totes, blood products, specimen racks). The system shall include configurable or removable internal accessories (e.g., liners, trays, baskets, or equivalent) that allow safe carriage of a variety of healthcare items such as prescription medications, 24 hour urine bottles, IV bags, test tube racks, and food containers commonly used at VA Long Beach. 3. Physical Characteristics The mobile robot width shall not exceed approximately 20 inches, enabling safe passage through standard VA corridors, doorways, and elevators. The overall height of the robot shall be approximately 37 inches to maintain visibility and accessibility for staff in nurse stations and corridors. The system shall be constructed of sturdy, resilient, easy to clean materials suitable for VA clinical environments, with smooth exterior surfaces compatible with commonly used hospital grade disinfectants. 4. Power and Endurance The robot shall support at least 24 hours of operation in a typical healthcare duty cycle with intermittent charging (i.e., the robot automatically or manually docks to recharge between runs without being removed from service for a full working day). The system shall include a docking/charging station compatible with standard 110 volt AC power, with a footprint not exceeding approximately 18 inches wide by 8 inches high by 10 inches deep. 5. Navigation and Maneuverability The robot shall support multiple navigation modes, including point to point delivery and other facility defined behaviors (e.g., delivery, usher, mingle, or functionally equivalent modes) that support VA logistics and clinical workflows. The robot shall have an effective turning radius of 0 feet (i.e., shall be capable of point turns in place) to maneuver in tight spaces such as corridors, patient room entries, and pharmacy/laboratory areas. 6. Communications and User Interface The system shall communicate with facility infrastructure using secure wireless communication, including Wi Fi; support for wide area connectivity (e.g., LTE or equivalent) is desired or shall be offered if commercially available. The system shall allow VA staff to initiate, monitor, and manage deliveries through a user interface appropriate for clinical and logistics personnel with minimal training (e.g., on robot touchscreen, workstation client, or mobile application). The user interface shall provide clear, task oriented controls and shall avoid vague performance descriptors such as user friendly or fastest, consistent with sound salient characteristics practices. 7. Environment and Support The system shall be designed and configured for interior use in VA healthcare facilities, including inpatient wards, outpatient clinics, ancillary services, and associated clinical spaces. The contractor shall provide technical and maintenance support appropriate for 24/7/365 VA healthcare operations (e.g., remote support, troubleshooting assistance, and replacement or repair procedures), consistent with commercial practices for mission critical hospital equipment. 8. Trade Agreements Act and Domestic Preference The offered robot system (including docking station and integrated software) shall comply with applicable Trade Agreements Act (TAA) requirements and other domestic preference requirements referenced in the RFQ, as implemented in FAR Part 25 and applicable VA Acquisition Regulation (VAAR) clauses, as incorporated by the Contracting Officer. Offerors shall identify the country(ies) of origin of the end product(s) and shall certify compliance with TAA and applicable Buy American/domestic preference requirements in accordance with the solicitation s FAR/VAAR provisions and clauses. If an offered end product is not TAA compliant or domestic, the offeror shall clearly disclose this in its quotation so that the VA Contracting Officer can determine acceptability and apply any required price evaluation preferences or restrictions. 9. Competitive, Non Brand Name Basis These salient characteristics are expressed as minimums or approximate maximums (e.g., at least, not to exceed approximately ) to allow full and open competition; no specific brand name or model is required. Any commercial item that meets or exceeds all enumerated salient characteristics shall be considered technically acceptable, subject to the RFQ s evaluation criteria (e.g., price and past performance) and all other terms and conditions. Descriptive literature submitted with quotations shall clearly demonstrate how the quoted product meets or exceeds each salient characteristic; literature that merely reproduces marketing claims without quantifying key performance metrics may be deemed insufficient. If your company is interested in and capable of providing the required supplies/services, you MUST provide the information indicated below OR your intent, interest to participation, and information provided will not be considered as valid for research purposes. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements. For instances where your company cannot meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please explain. For instances where your company can meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please clearly show how your company meets/exceeds each requirement otherwise your response will be recorded as interest only . (2) Please review the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of DRAFT/SALIENT CHARACTERISTICS/SOW? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? Please indicate if manufacturer is/will be US domestic Small Business / US Domestic Large Business / Foreign. (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your organization offer a leasing solution? Please elaborate. (15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (18) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to sam.choo@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, November 13, 2026 by 10:00 AM PST. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.
-Market Research11/13/2026
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing. Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The purpose of this procurement is to acquire autonomous healthcare delivery robot system for interior use at the VA Long Beach Healthcare System Pharmacy (VALBHS). 1. Functional and Performance Requirements The system shall autonomously transport and deliver critical Pharmacy medical supplies, pharmacy orders, and similar healthcare items within interior areas of VA Long Beach without continuous human teleoperation during normal operation. The system shall employ self driving obstacle avoidance technology that uses at least two sensing modalities from among 3D vision, eye safe laser ranging, and sonar (or functionally equivalent technologies) to map and navigate the facility while avoiding people and obstacles in a dynamic hospital environment. The robot shall be capable of continuous transport operations at a nominal walking pace appropriate for safe operation among staff and patients (approximately 2 4 miles per hour), with the ability to adjust speed as needed to comply with VA safety policies. 2. Payload and Capacity The robot shall provide at least one lockable, top loading cargo compartment designed for interior healthcare use. The primary cargo compartment shall have a total internal volume of at least 41 liters (approximately 11 gallons). The cargo compartment shall support a minimum payload of 50 pounds of medical items (e.g., linens, infusion pumps, towels, pharmacy totes, blood products, specimen racks). The system shall include configurable or removable internal accessories (e.g., liners, trays, baskets, or equivalent) that allow safe carriage of a variety of healthcare items such as prescription medications, 24 hour urine bottles, IV bags, test tube racks, and food containers commonly used at VA Long Beach. 3. Physical Characteristics The mobile robot width shall not exceed approximately 20 inches, enabling safe passage through standard VA corridors, doorways, and elevators. The overall height of the robot shall be approximately 37 inches to maintain visibility and accessibility for staff in nurse stations and corridors. The system shall be constructed of sturdy, resilient, easy to clean materials suitable for VA clinical environments, with smooth exterior surfaces compatible with commonly used hospital grade disinfectants. 4. Power and Endurance The robot shall support at least 24 hours of operation in a typical healthcare duty cycle with intermittent charging (i.e., the robot automatically or manually docks to recharge between runs without being removed from service for a full working day). The system shall include a docking/charging station compatible with standard 110 volt AC power, with a footprint not exceeding approximately 18 inches wide by 8 inches high by 10 inches deep. 5. Navigation and Maneuverability The robot shall support multiple navigation modes, including point to point delivery and other facility defined behaviors (e.g., delivery, usher, mingle, or functionally equivalent modes) that support VA logistics and clinical workflows. The robot shall have an effective turning radius of 0 feet (i.e., shall be capable of point turns in place) to maneuver in tight spaces such as corridors, patient room entries, and pharmacy/laboratory areas. 6. Communications and User Interface The system shall communicate with facility infrastructure using secure wireless communication, including Wi Fi; support for wide area connectivity (e.g., LTE or equivalent) is desired or shall be offered if commercially available. The system shall allow VA staff to initiate, monitor, and manage deliveries through a user interface appropriate for clinical and logistics personnel with minimal training (e.g., on robot touchscreen, workstation client, or mobile application). The user interface shall provide clear, task oriented controls and shall avoid vague performance descriptors such as user friendly or fastest, consistent with sound salient characteristics practices. 7. Environment and Support The system shall be designed and configured for interior use in VA healthcare facilities, including inpatient wards, outpatient clinics, ancillary services, and associated clinical spaces. The contractor shall provide technical and maintenance support appropriate for 24/7/365 VA healthcare operations (e.g., remote support, troubleshooting assistance, and replacement or repair procedures), consistent with commercial practices for mission critical hospital equipment. 8. Trade Agreements Act and Domestic Preference The offered robot system (including docking station and integrated software) shall comply with applicable Trade Agreements Act (TAA) requirements and other domestic preference requirements referenced in the RFQ, as implemented in FAR Part 25 and applicable VA Acquisition Regulation (VAAR) clauses, as incorporated by the Contracting Officer. Offerors shall identify the country(ies) of origin of the end product(s) and shall certify compliance with TAA and applicable Buy American/domestic preference requirements in accordance with the solicitation s FAR/VAAR provisions and clauses. If an offered end product is not TAA compliant or domestic, the offeror shall clearly disclose this in its quotation so that the VA Contracting Officer can determine acceptability and apply any required price evaluation preferences or restrictions. 9. Competitive, Non Brand Name Basis These salient characteristics are expressed as minimums or approximate maximums (e.g., at least, not to exceed approximately ) to allow full and open competition; no specific brand name or model is required. Any commercial item that meets or exceeds all enumerated salient characteristics shall be considered technically acceptable, subject to the RFQ s evaluation criteria (e.g., price and past performance) and all other terms and conditions. Descriptive literature submitted with quotations shall clearly demonstrate how the quoted product meets or exceeds each salient characteristic; literature that merely reproduces marketing claims without quantifying key performance metrics may be deemed insufficient. If your company is interested in and capable of providing the required supplies/services, you MUST provide the information indicated below OR your intent, interest to participation, and information provided will not be considered as valid for research purposes. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements. For instances where your company cannot meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please explain. For instances where your company can meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please clearly show how your company meets/exceeds each requirement otherwise your response will be recorded as interest only . (2) Please review the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of DRAFT/SALIENT CHARACTERISTICS/SOW? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? Please indicate if manufacturer is/will be US domestic Small Business / US Domestic Large Business / Foreign. (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your organization offer a leasing solution? Please elaborate. (15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (18) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to sam.choo@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, November 13, 2026 by 10:00 AM PST. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.
-Market Research11/13/2026
This is Public Notice. This is a brand name award notification for the contract awarded to Abbott Laboratories Inc. 3200 Lakeside DR Santa Clara, California 95054-2807. This contract is for EnSite X EP Mapping System & Peripherals.
-Sole Source / J&AOpen
This is a combined synopsis/solicitation for commercial products prepared in accordance with the Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) Parts 12 and 15. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0005 is issued as a Request for Proposal (RFP) for NX EQ Ultrasonic Aspirator System: Tissue Ablation and related accessories. This acquisition is set-aside for Service Disabled Veteran Owned Small Business (SDVOSB) concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A PRICE COST SCHEDULE NX EQ Ultrasonic Aspirator System: Tissue Ablation for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide descriptive literature which will be used to determine the extent to which it meets the salient characteristics listed in the Attachment B Product Description. All of the salient characteristics listed in the solicitation must be met to be considered eligible for award. Those proposals which fail to meet all of the salient characteristics will be rated Unacceptable and will be ineligible for award. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract.
-Combined Synopsis12/01/2026
-AwardedOpen

Additional Details

Solicitation Number

36C26126Q0289

Archive Date

May 3, 2026

Office Address