Notice ID: c8bb8441c7db4030aff49b3ac8fca88cAward NoticeAwardedArchived
F103--HVAC Cooling Towers Testing and Maintenance for VA Palo Alto Health Care System
Awarded on June 29, 2026. Full description on SAM.gov.
Awarded tounder 36C26126P0786 (source: SAM.gov award notice)• $1.3M
Overview
- Posted
- June 29, 2026
- Notice type
- Award Notice
- Set-aside
- Service-Disabled Veteran-Owned Small Business Set Aside
- NAICS
- 541380: Testing Laboratories and Services
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 261-NETWORK CONTRACT OFFICE 21 (36C261)
- Place of performance
- See Performance Work Statement
- Last updated
- Oct 29, 2026
- First published
- Last updated on SAM.gov
- Award date
- Jun 29, 2026
- Award amount (SAM.gov award notice)
- $1.3M
Identifiers
- Solicitation number
- 36C26126Q0576
- Notice ID
- c8bb8441c7db4030aff49b3ac8fca88c
- Award number (PIID)
- 36C26126P0786
Description
Question and Answer What is the system volume of each CT? The specifications vary depending on the cooling tower. Please refer to the make and model information outlined in the Performance Work Statement, Scope of Work, or inventory for these details. What are the cubic feet of each CT (including underground sumps)? Please refer to the make and model information provided in the inventory. For PAD (VA Palo Alto), Building 100, the cooling tower sump dimensions are 25 feet by 44 feet, with an approximate depth of 6 feet. What is the annual average continuous cooling tonnage for each CT? It varies depending on the location. Please refer to the Performance Work Statement or Scope of Work for further details. Who owns the existing chemical tanks, chemical pumps, and water treatment controllers? The VA owns the existing water treatment controllers, chemical base tanks, and chemical pumps. Should the cost of new water treatment controllers, chemical base tanks, and chemical pumps be included in the bid? The VA owns the existing water treatment controllers, chemical base tanks, and chemical pumps; therefore, the cost of these systems should be excluded. What is the current chemical delivery process? What package size is used for chemical base tanks, and who is responsible for transfer into the base tanks? The contractor shall be responsible for determining the appropriate size of the chemical base tank at each location, as well as for the delivery of chemicals and their transfer into the base tanks. What are the closed-loop volumes, and should the cost of biocide treatment be included? The VA is unable to provide this information currently. The contractor may need to utilize estimation tools to approximate the volume of these closed loops. Additionally, chemicals may be added incrementally until the required parts per million (ppm) of corrosion inhibitor are achieved. What is the approximate annual closed-loop makeup water volume for determining inhibitor treatment demand? We do not have a specific number for this, as it fluctuates frequently due to leaks and ongoing maintenance activities. The demand for inhibitor treatment will vary in accordance with the condition of the loop at any given time. Water samples could not be obtained during the site survey. Please provide the cooling water makeup quality or target cycles for cooling water makeup quality or target cycles at this time. All cooling towers and closed loops are currently maintained in accordance with VA HVAC standards and are operating within established limits. At this time, we are unable to provide detailed information; however, a sample report may be made available to the awardee following contract award, in accordance with the Performance Work Statement or Scope of Work. Will the onsite team pull samples for Nalco field water testing? No, the contractor (awardee) representative will be responsible for collecting, analyzing, and reporting sample data as required by the contract. VA representatives will not collect samples on behalf of the contractor. Can we propose monthly CT service with a smart controller and continuous remote monitoring as a substitute for weekly non-connected controllers? No. The contractor s representative is required to perform testing in person to ensure that all aspects of the system are thoroughly evaluated, and so that the technician can observe and report any changes to the COR for awareness. Please refer to the Performance Work Statement or Scope of Work for this contract for additional details. Can we use third-party chemical drum drop-off delivery? It is preferred and recommended that the contractor (awardee) receive and store chemical deliveries at their local site, as the VA will not be responsible for any missing or stolen deliveries. Could you provide the model and SN? Please refer to the Performance Work Statement or Scope of Work for a detailed inventory, which includes make and model information. Could you provide information on the sort of testing and maintenance you are looking for? Please refer to the Performance Work Statement or Scope of Work for this contract for detailed information regarding the maintenance checklist for cooling towers (CT) on a monthly, quarterly, and annual basis, as well as the types of tests required for cooling towers and closed loops. Do they want a rep onsite for weekly testing? Yes, it is required as per contract. Will a total of 20 samples be collected from the entire campus or 20 samples from each individual building? Please refer to the Performance Work Statement or Scope of Work for information regarding the number of loops and cooling towers, as well as the total number of samples to be collected. Samples are to be obtained from various buildings, campuses, or locations.
Award Overview
Award Number
36C26126P0786
Award Amount (SAM.gov award notice)
$1.3M
Award Date
Jun 29, 2026
Awardee
Awardee UEI
ZHAMN7JMA791
Awardee CAGE Code
6TM80
Awardee Address
HONOLULU, HI 96815, HI
Original Solicitation
Notice ID: c8bb8441c7db4030aff49b3ac8fca88c
Posted Date: Jun 29, 2026
Original Response Deadline: Not specified
More From This Vendor
Top 5 most recent
- $124.9KSigned Jul 13, 2026
- $92.7KSigned Jun 2, 2026
- $124.9KSigned Aug 8, 2025
- $668.9KSigned Jul 17, 2025
- $484.0KSigned Mar 18, 2025
Contacts
Contracting Officer
Primary Contact
Documents
Files (1)
- Download
36C26126P0786_1.docx
13 KBAdded in Award Notice version 3Posted
Lifecycle
- 3Version 3Award NoticeArchivedCurrent
F103--HVAC Cooling Towers Testing and Maintenance for VA Palo Alto Health Care System
Other notices for this solicitation
- SolicitationRelated noticeApr 23, 2026
F103--HVAC Cooling Towers Testing and Maintenance
- Pre-SolicitationRelated noticeApr 23, 2026
F103--HVAC Cooling Towers Testing and Maintenance
- SolicitationRelated noticeApr 23, 2026
F103--HVAC Cooling Towers Testing and Maintenance
- SolicitationRelated noticeMay 18, 2026
F103--HVAC Cooling Towers Testing and Maintenance
- SolicitationRelated noticeMay 20, 2026
F103--HVAC Cooling Towers Testing and Maintenance
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Amendment 0002 to RFQ 36C26326Q0188 Adding Technical questions and answers Adding S02. RFQ 36C26326Q0188 Amended | 78% | Combined Synopsis | 08/21/2026 |
Solicitation Extension | 74% | Solicitation | 11/20/2026 |
Water Testing Durham VA Medical Center and CBOCs | 74% | Pre-Solicitation | 11/09/2026 |
Utility Critical Water Testing - The purpose of this Amendment is to cancel solicitation 326C24626Q0906. Solicitation 36C24626Q0903 is hereby canceled. This requirement will be solicited at a later date. | 74% | Solicitation | 08/28/2026 |
Utility Critical Water Testing | 74% | Pre-Solicitation | 08/28/2026 |
Additional Details
Solicitation Number
36C26126Q0576
Archive Date
Aug 28, 2026
Office Address
MATHER, CA, 95655