Stryker Stretchers OR EQUAL - VA Southern Nevada Healthcare System
Archived on September 19, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM PDT
- Posted
- September 3, 2026
- Notice type
- Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS
- 339113: Surgical Appliance and Supplies Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 261-NETWORK CONTRACT OFFICE 21 (36C261)
- Place of performance
- North Las Vegas, Nevada, 89086
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C26126Q1215
- Notice ID
- 3f25698f0175436f846245ffdd443ef3
Description
Amendment 0002 - Extend quote due date to 9/4 and remove all line items associated with Gynnie Stretchers (0030-0046). Please acknowledge amendment with your quote.
Amendment 0001 - Extend quote due date to 9/3 and remove line items. Please acknowledge amendment with your quote.
VA Southern Nevada Healthcare System has a requirement for Stryker Stretchers OR EQUAL. This is a total SDVOSB set-aside.
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Vendor
STRYKER CORPORATIONContract end date
Dec 2, 2026
NAICS
339113
Agency
Department of Veterans Affairs
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Contracting Officer
Primary Contact
Documents
Lifecycle
- 1Version 1SolicitationArchived
Stryker Stretchers OR EQUAL - VA Southern Nevada Healthcare System
- 2Version 2SolicitationArchived
Stryker Stretchers OR EQUAL - VA Southern Nevada Healthcare System
- 4Version 4SolicitationArchivedCurrent
Stryker Stretchers OR EQUAL - VA Southern Nevada Healthcare System
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
UltraScan Versa Premier Tables | 67% | Combined Synopsis | 09/27/2026 |
SOURCE SOUGHT NOTICE Rehabilitation Equipment High Low Beds and Parallel Bars This announcement requests information from industry to support market research and preliminary acquisition planning for the procurement of physical therapy/rehabilitation equipment needed for a new clinic near Indianapolis, IN. The purpose of this notice is to assess industry interest and identify potential sources with the capabilities and qualifications to meet the following requirements. This is not a solicitation for quotes. No contract will be awarded from this notice. No proposals are being requested or accepted with this notice. The government will not pay any costs for the time and effort to respond to this notice. REQUIREMENT The agency is seeking information on domestic sources of supply for two pieces of medical equipment as described below: Parallel Bars, Physical Therapy (quantity 1 each) Description: The electric platform-mounted parallel bars shall provide adjustable support for gait training, balance, mobility, and rehabilitation activities. The system shall provide powered height adjustment, adjustable width, a slip-resistant walking platform, and stable handrails to accommodate patients of varying sizes and functional abilities. Salient Characteristics: Made in America. Provides a 10-foot gait-training platform. Provides 500 lb load capacity. Electrically adjusts handrail height from approximately 26 54 in. Manually adjusts handrail width from approximately 20 34 in. Includes 1.5-in. diameter stainless-steel handrails. Includes a 48-in. wide, two-piece slip-resistant platform. Provides digital height display and four programmable height settings. Provides synchronized powered height adjustment with automatic safety shutoff. Equipment shall be new, current-production equipment suitable for professional rehabilitation applications. ETL approved. Table, Treatment, Hi-Lo, Bariatric, 500-lb capacity (quantity 3 each) Description: The bariatric hi-lo treatment table shall provide a stable, electrically powered treatment surface for patient examination, evaluation, rehabilitation, and therapeutic procedures. The table shall support safe patient transfers through powered height adjustment while providing multiple positioning options to accommodate a wide range of clinical applications. The system shall be suitable for physical therapy, occupational therapy, rehabilitation, outpatient clinics, sports medicine, and VA healthcare facilities. Salient Characteristics: Made in America Provides a powered height-adjustable treatment surface with a height range of approximately 18 to 37 inches to facilitate patient accessibility and clinician ergonomics. Supports a minimum patient weight capacity of 500 pounds. Includes a three-section upholstered treatment surface to support a variety of patient positioning and therapeutic procedures. Provides an adjustable head section with a positioning range from approximately +45 degrees to -90 degrees. Provides an adjustable lower extremity section with a positioning range from 0 to approximately 78 degrees. Features perimeter foot-operated height controls that allow clinicians to adjust table height from either side while maintaining continuous patient contact. Includes a heavy-duty frame designed to provide stability during patient treatment and transfers. Features four total-lock swivel casters to facilitate movement and secure positioning during patient care. Includes high-density foam cushioning and seamless, heavy-duty upholstered surfaces designed for patient comfort and ease of cleaning. Features rounded table edges and corners to enhance patient safety and reduce the potential for injury. Provides a low transfer height of approximately 18 inches to facilitate patient accessibility and transfers. Operates on standard 120 VAC, 60 Hz electrical service. Includes all power cords, controls, mounting hardware, and accessories necessary for complete clinical operation. Equipment shall be new, current production model equipment suitable for professional healthcare examination, rehabilitation, and therapeutic treatment applications. Interested parties who can provide the products described are requested to submit the following information: Company name, address and point of contact with phone number, SAM Unique Entity Identifier (UEI)*, Product information documenting salient characteristics, Feedback on salient characteristics, Place of manufacture, Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc., and Any other pertinent product, company, or industry information. * Note: To be eligible for award of a federal contract, businesses must have an active registration in the System for Award Management (SAM). Firms that respond to this Sources Sought Notice without providing all the requested information may not be considered by the Government in making acquisition decisions. This market research is conducted for informational and planning purposes only. This notice does not constitute a solicitation and does not obligate the Government to issue a solicitation. The Government, at its sole discretion, may elect not to notify respondents of the results of this notice or otherwise release those results. Send submissions via email to Brian.Rosciszewski@VA.gov, reference 36C25027Q0044 in email subject. Thanks in advance for supporting America s veterans. ** End of Sources Sought Notice ** | 63% | Market Research | 10/30/2026 |
63% | Awarded | Open | |
63% | Awarded | Open | |
THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. THIS IS STRICTLY MARKET RESEARCH. Patient safety lifts The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide Patient safety lifts. All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum: (1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation. Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via email to kurt.fritz@va.gov RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement. Salient characteristics (QTY 21) Patient Safety Lifts All ceiling mounted hoists, rails, and components must comply with ISO 10535:2021 xy Systems Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. Cover 5m X 10m area with trainer (QTY 1) Cover 4m X 4m area (QTY 9) Cover 4m x 3m area (QTY 2) Cover 3m x 3m area (QTY 1) Linear Tracks Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. 3m Linear Track (QTY 3) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better 4m Linear Track (QTY 4) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up 825 lbs. or better 6m Linear Track (QTY 1) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better Patient Lift Supports minimum 550 lbs. (QTY 17) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: Uses 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 2 hours (for this capacity class). Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information. Patient Lift Supports minimum 825 lbs. (QTY 4) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: dual 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 4 hours or better Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information. Medium Hanger Bar (QTY 21) Lifts up to 825 lbs. Four attachment points for a safe, stable, and comfortable lift. Works with ceiling and mobile lifts and fits standard slings. Strong, rust resistant metal covered with soft, easy to clean foam. Lightweight (4 lbs.) and easy to handle. Medium size (~24 wide) Trainer Module Motor (QTY 1) Reducing bodyweight, relieves up to 100 kg (220 lbs.), Built into the ceiling hoist added to system, controlled via the hand control interface. Safe exercise sessions: positioning lock and fall protection, enabling standing exercises, squats, steps, balance training, and sit-to-stand movements. 30-minute training limit: each session lasts up to 30 minutes per full battery charge, with clear indicators for weight relief and remaining time. After session, will automatically resume normal lift mode. Battery management: 1 hour of charge delivers about 10 minutes of training time. When training ends, it reverts to standard lifting and resumes charging. Installation (QTY 21) Install lift systems in 21 rooms. Labor and the hardware necessary to install the lift systems. Must support up to Level II that is identified in the Infection Control Risk Assessment (ICRA). Perform weight testing and certification of the installed lift systems. Removal of 18 existing lift systems. Design / Drafting (QTY 1) Stamped Engineering Calculations Slings (QTY 84) Support 450 lbs. or better Made from polypropylene material Disposable Limb Sling (QTY 1 per system) Disposable Basic High sling (QTY 1 per system) Disposable Twin Turner (QTY 1 per system) Disposable Repositioning Sling (QTY 1 per system) User Training (QTY 1) | 63% | Market Research | 09/10/2026 |
Additional Details
Solicitation Number
36C26126Q1215
Archive Date
Sep 19, 2026
Office Address
MATHER, CA, 95655