J065--MEDICAL GAS SERVICES & ALARMS - FY24 POP (04/01/2024 - 03/31/2025)

Awarded on March 31, 2024. Full description on SAM.gov.

Awarded tounder 36C26224P1005 (source: SAM.gov award notice)• $203.0K

Overview

Posted
April 5, 2024
Notice type
Award Notice
Set-aside
Total Small Business Set-Aside (FAR 19.5)

Notice details

Place of performance
Department of Veterans Affairs VA Greater Los Angeles Healthcare System(VAGLAHCS) West Los Angeles Medical Center (WLA VAMC) 11301 Wilshire Blvd, Los Angeles, 90073-1003
Last updated
Sep 9, 2025
Award date
Mar 31, 2024
Award amount (SAM.gov award notice)
$203.0K

Identifiers

Solicitation number
36C26224Q0827
Notice ID
c501cc4b2e8c45dc843a1ed7a701937a
Award number (PIID)
36C26224P1005

Description

This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-03. This solicitation is being set-aside for Small Business (SB). The associated North American Industrial Classification System (NAICS) code for this procurement is 811210, with a small business size standard of $34.0 Million. The FSC/PSC is J065. The VA Greater Los Angeles Healthcare System (VAGLAHCS) is seeking a contractor to certified and licensed contractor to inspect and repair medical air, oxygen, dental air, operating nitrogen, medical vacuum, monitoring and alarm systems for medical gases. After the repairs, the contractor shall also provide certification for use. Technicians are required to be ASSE 6040 certified. Contractor shall also provide emergency on call repairs as needed. Services will be provided at the West Los Angeles Medical Center (WLA VAMC), 11301 Wilshire Blvd, Los Angeles, CA 90073-1003, the Los Angeles VA Clinic (LA ACC), 351 E Temple St., Los Angeles, CA 90012-3328, and the Sepulveda VA Medical Center (SACC), 16111 Plummer St., Sepulveda, CA 91343-2036. All interested companies shall provide quotations for the following: Supplies/Services The contractor shall provide all labor, materials, supplies, tools, equipment, parts, software (needed for the general operation of the equipment), travel, ICRA Barriers, supervisors, and qualified personnel to accomplish the tasks outlined in this SOO. Contractor is responsible for all subcontractors required to complete reports. All work shall be performed during normal hours unless otherwise approved by the COR or his/her designee. Contractor to provide service to all medical gases and locations listed: Medical Gas System Maintenance / Testing for VAGLAHCS: Medical air filter changes in the interstitial of building 500. Dental vacuum line flushing every 6 months. Vaporizer changes on the bulk oxygen tank system Weekly. Service to medical air compressors, Instrument Air compressor, Vacuum Pumps and Dental Air compressors. Location of these units is building 501. Report of annual service rendered shall be provided. There must be a technicians required to adequately perform tasks on-site at least three days a week Contractor to be awarded contract must have multiple ASSE 6040 certified technicians (minimum of six techs) located within 2 hours of the facility to respond to any emergency service need within those two hours. Contractor to be awarded shall also have multiple ASSE 6030 (minimum of three techs). There shall be a 24 hour/day 7days a week response to emergency service needs to include all holidays. Annual preventative maintenance inspection report shall be provided using the most current applicable NFPA 99 as a guideline. The reports shall include a system performance summary, source evaluation report according to applicable NFPA 99 CODE, and pictures of the following systems: Oxygen, Medical Air, Vacuum, Nitrous Oxide, Nitrogen, Carbon Dioxide. Bulk Oxygen System at building 500 Oxygen manifold building 500 third floor south backup system inside RM 3401 Clean Utility Supply Room Oxygen Manifold Building 500 third floor West Emergency reserve inside room 3601 utility Supply Room Medical Air Compressor system at building 501 Medical Vacuum Pump System at Building 501 Nitrous Manifold system serving Building 500 fifth floor operating Rooms 5 North and 5 East located south of building 500 next to bulk oxygen storage tanks. Nitrous Manifold system serving building 500 OR Sim Lab Room 0410 located at building 500 tank room ground level room 0407 Nitrogen Manifold system serving building 500 located at building 500 ground level room 0257A Nitrogen Manifold system serving building 500 OR Sim lab room 0410 located at building 500 G level room 0410 Carbon Dioxide Manifold serving building 500 OR s 1-8 located at Building 500 Fifth floor interstitial Carbon Dioxide Manifold serving building 500 OR Sim lab room 0410 located at Tank Room G level room 0407 Master Alarm Panel located at control room testing for signal, status, and functionality for: Oxygen bulk site, medical air compressor, vacuum pump, nitrous oxide manifold, nitrogen manifold, and carbon dioxide manifold. Master Alarm Panel located at PBX inside room 1608 testing for signal, status, and functionality for: Oxygen bulk site, medical air compressor, vacuum pump, nitrous oxide manifold, nitrogen manifold, and carbon dioxide manifold. Master Alarm Panel located at ER Nurse Station across from room 1E044 testing for signal, status, and functionality for: Oxygen bulk site. Master Alarm Panel located at building 500 third floor south across from nurse station testing for signal, status, and functionality for: Oxygen manifold. Master Alarm Panel located at building 500 Fifth floor OR nurse desk testing for signal, status, and functionality for: Carbon Dioxide manifold. Master Alarm panel located at building 500 PBX inside room 1608 testing for signal, status, and functionality for: Oxygen manifold, nitrous oxide manifold, nitrogen manifold, and carbon dioxide manifold. Master Alarm panel located at building 500 inside room 0410D Control Room testing for signal, status, and functionality for: nitrous oxide manifold, nitrogen manifold, and carbon dioxide manifold Master Alarm Panel located next to building 500 next to room 3637 testing for signal, status, and functionality for: Oxygen manifold. Outlet inspection data report for Oxygen, Medical Air, Vacuum, Nitrous Oxide, Nitrogen, WAGD, and Carbon Dioxide where applicable at the following rooms: GROUND FLOOR BLDG 500- Dental Room 0001, Dental Room 0004, Dental Room 0005, Dental Room 0006, Dental Room 0007, Dental Room 0008, Dental Room 00011, Dental Room 00012, Dental Room 00013, Dental Room 00014, Dental Room 00015, Dental Room 00016, Dental Room 0021, Dental Room 0022, Dental Room 0023, Dental Room 0024, Dental Room 0025, Dental Room 0035, Dental Room 0036, Dental Room 0038, Dental Room 0039, Dental Room 0040, Dental Room 0045, Dental Room 0046, Dental Room 0047, Dental Room 0048, Dental Room 0049, Dental Room 0050, Dental Room 0052, Dental Room 0054, Dental Room 0056, Dental Room 0058, Dental Room 0059, Nuclear Medicine 0083 Symbia T, Bio Graph 0081 A, Bio Graph 0081 B, Nuclear Med 0067 PET/CT Scanner, Symbia EVO 0080, Nuclear Medicine 0086A Stress Lab, Cysto #1 0093, Cysto #2 0098, Cysto #3 0097, Prep 0099 A, Prep 0099 B, Prep 0099 C, ENT 0211, ENT 0212, ENT 0213, ENT 0214, ENT 0221, Ultrasound Room #4 0673, X-Ray #8 0665, CT Scan B 0667, Mammography Exam Room 0668, 0679, MRI Holding A, MRI Holding B, MRI Holding C, CT Scanner A, MRI, CT Scan, Room 0421, X-Ray #1 0626, X-Ray #2 0624, X-Ray #3 0621, X-Ray 0644, X-Ray #4 0637, X-Ray #5 0639, X-Ray #6 0641, X-Ray #7 0650, Ultrasound Room #1 0681, Ultrasound Room #2 0645, Ultrasound Room #3 0648, 0410 OR Sim Lab, ICU Simulation Lab 0411 A, 0210. FIRST FLOOR BUILDING 500- ED Bed 1 1E027, ED Bed 2 1E028, ED Bed 3 1E029, ED Bed 4 1E030, ED Bed 5, ED Bed 6, ED Bed 7, ED Bed 8 1E034, ED Bed 9 1E035, ED Bed 10 1E036, ED Bed 11, ED Bed 12, ED Bed 13, ED Bed 14 1E041, ED Bed 15 1E042, ED Bed 16 1E043, ED Bed 17 1E045, ED Bed 18 1E014, ED Bed 19 1E011, ED Bed 20 1E009, 1641, 1642, 1643, 1644 A, 1B017 Procedure Room, Fast Track Room 3 (1E007), Fast Track Room 4 (1E008), Triage Room (1E006). SECOND FLOOR BUILDING 500- 2025 A, 2025 B, 2026 A, 2026 B, 2027, 2028, 2029, 2033 A, 2033 B, 2040 A, 2040 B, 2044, 2045, 2046, 2047 A, 2047B, 2048 A, 2048 B, 2206 A, 2206 B, 2211, 2212, 2213 A, 2213 B, 2214, 2215 A, 2215 B, 2223 A, 2223 B, 2224 A, 2224 B, 2225, 2226, 2227, 2231 A, 2231 B, 2238 A,, 2238 B, 2242, 2243, 2244, 2245 A, 2245 B, 2246 A, 2246 B, 2253 A, 2253 B, 2254, 2255 A, 2255 B, 2256, 2257, 2262 A, 2262 B. THIRD FLOOR BUILDING 500- 3006, 3013 A, 3013 B, 3015, 3018, 3020, 3023, 3024, 3025 B, 3025 C, 3032, 3025 E A, 3025 E B, 3025 E C, 3025 D A, 3025 D B, 3034, 3035 A, 3035 B, 3040 A, 3040 B, 3044, 3047, 3048, 3049, 3050, 3057, 3060, 3061, 3066, 3067, 3068, 3069, 3205 A, 3205 B, 3209, 3210, 3211 A, 3211 B, 3212, 3216, 3220 A, 3220 B, 3221, 3222, 3223, 3224, 3229 A, 3229 B, 3237, 3242, 3243, 3244, 3245 A, 3245 B, 3246, 3255 A, 3255 B, 3256, 3257 A, 3257 B, 3259, 3263 A, 3263B, 3403, 3408, 3410, 3411, 3413, 3415, 3417, 3425, 3427, 3429, 3431, 3433, 3442, 3444, 3446, 3448, 3456, 3458, 3460, 3463, 3465, 3474, 3476, 3479, 3481, 3483, 3490, 3603, 3607, 3609, 3610, 3612, 3613, 3616, 3624, 3627, 3629, 3630, 3633, 3639, 3642, 3644, 3646, 3653, 3656, 3657, 3660, 3663, 3672, 3674, 3676, 3678, 3680, 3685, 3213 A, 3213 B. FOURTH FLOOR BUILDING 500- 4011, 4015, 4016, 4017 A, 4017 B, 4019, 4020, 4032, 4033, 4039, 4042, 4043 A, 4043 B, 4045, 4048 A, 4048 B, 4048 C, 4048 D, 4048 E, 4048 F, 4054 A, 4054 B, 4058, 4061, 4062 A, 4062 B, 4064, 4065, 4075, 4076, 4078 A, 4078 B, 4079, 4080, 4084, 4085, 4204, 4208, 4209, 4210 A, 4210 B, 4211, 4212 A, 4212 B, 4224, 4225, 4227 A, 4227 B, 4228, 4231, 4235 A, 4235 B, 4240 A, 4240 B, 4244, 4247, 4248 A, 4248 B, 4250, 4251, 4264, 4265, 4266 A, 4266 B, 4267, 4268, 4272, 4273, Cardiac Cath Lab 4414 A, Cardiac Cath Lab 4414 B, Cardiac Cath Lab 4414 C, EP Lab 4416 A, EP Lab 4416 B, EP Lab 4416 C, 4424 A, 4424 B, 4436 A, 4436 B, 4438 A, 4438B, 4442, 4443, 4444, 4445 A, 4445 B, 4448, Cardiac Cath Supply 4474, 4603, 4607, 4608, 4609 A, 4609 B, 4611A, 4611 B, 4616, 4624, 4625, 4626 A, 4626 B, 4627, 4630, 4634, 4637, 4639 A, 4639 B, 4639 C, 4640, 4643, 4647, 4650, 4651 A, 4651 B, 4653, 4654, 4659, 4667, 4668, 4669 A, 4669 B, 4670, 4671, 4675 A, 4675 B, 4662. FIFTH FLOOR BUILDING 500- OR 1 A 5016, OR 1 B 5016, OR 2 A 5018, OR 2 B 5018, OR 3 A 5020, OR 3 B 5020, OR 4 A 5025, OR 4 B 5025, OR 5 A 5027, OR 5 B 5027, OR 5 C 5027, OR 6 A 5033, OR 6 B 5033, OR 7 A 5034, OR 7 B 5034, OR 8 A 5036, OR 8 B 5036, Anesthesia Workroom 5037, Holding Bed 1, Holding Bed 2, Holding Bed 3, Holding Bed 4, Holding Bed 5, Holding Bed 6, Holding Bed 7, OR 9 5216 A, OR 9 5216 B, OR 10 5217 A, OR 10 5217 B, 5218 A, 5218 B, I.R Lab 5221 A, I.R Lab 5221 B, 5222 A, 522 Bronchoscopy, 5224, 5248 GI Procedure Room, 5249 GI Procedure Room, 5250 GI Procedure Room, 5251 GI Procedure Room, 5263 A, 5263 B, 5270 Recovery Room Bed 1, 5270 Recovery Room Bed 2, 5270 Recovery Room Bed 3, 5270 Recovery Room Bed 4, 5270 Recovery Room Bed 5, 5270 Recovery Room Bed 6, 5270 Recovery Room Bed 7, 5270 Recovery Room Bed 8, 5270 Recovery Room Bed 9, 5270 Recovery Room Bed 10, 5409 PACU Bed 1, 5409 PACU Bed 2, 5409 PACU Bed 3, 5409 PACU Bed 4, 5409 PACU Bed 5, 5409 PACU Bed 6, 5409 PACU Bed 7, 5409 PACU Bed 8, 5409 PACU Bed 9, 5409 PACU Bed 10, 5409 PACU Bed 11, 5409 PACU Bed 12, 5420, 5421, 5422 A, 5422 B, 5423, 5426, 5430 A, 5430 B, 5436 A, 5436 B, 5440, 5443, 5444 A, 5444 B, 5445, 5446, 5460 A, 5460 B, 5461 A, 5461 B, 5462 A, 5462 B, 5463 A, 5463 B, 5464 A, 5464 B, 5465 A, 5465 B, 5466 A, 5466 B, 5474 A, 5474 B, 5475 A, 5475 B, 5476 A, 5476 B, 5613 Bed 7, 5614 Bed 8, 5616 Bed 9, 5617 Bed 10, 5618 Bed 11, 5620 Bed 12, 5622 MICU CCU Bed 1, 5623 MICU CCU Bed 2, 5624 MICU CCU Bed 3, 5626 MICU CCU Bed 4, 5668 MICU CCU Bed 5, 5669 MICU CCU Bed 6, HICU SICU 5632 BED 14, HICU SICU 5633 BED 15, HICU SICU 5634 BED 16, HICU SICU 5635 BED 17, HICU SICU 5637 BED 18, HICU SICU 5638 BED 19, HICU SICU 5646 BED 20, HICU SICU 5647 BED 21, HICU SICU 5648 BED 22, HICU SICU 5649 BED 23, HICU SICU 5650 BED 24, HICU SICU 5651 BED 25, HICU SICU 5658 BED 26, HICU SICU 5659 BED 27, HICU SICU 5661 BED 28, HICU SICU 5662 BED 29, HICU SICU 5663 BED 30, HICU SICU 5664 BED 31, 5671 Bed 32, 5672 Bed 33, 5674 Bed 34, 5675 Bed 35, 5676 Bed 36, 5689 Bed 37. SIXTH FLOOR BUILDING 500- 6034 Hemodialysis Bed 1, 6034 Hemodialysis Bed 2, 6034 Hemodialysis Bed 3, 6034 Hemodialysis Bed 4, 6034 Hemodialysis Bed 5, 6034 Hemodialysis Bed 6, 6034 Hemodialysis Bed 7, 6034 Hemodialysis Bed 8, 6037 Hemodialysis Bed 9, 6037 Hemodialysis Bed 10, 6037 Hemodialysis Bed 11, 6037 Hemodialysis Bed 12, 6037 Hemodialysis Bed 13. MEDICAL GAS ZONE VALVE FUNCTIONAL TESTING for capacity according to NFPA 99 most current applicable version for the following VAWLA locations at building 500: LOCATION- Near Room 0061 Nuclear Medicine; Area Controlled-0067 PET/CT Scanner, 0080 Symbia EVO,0081 Bio Graph, 0083 Symbia T, 0086A Stress Lab Manufacturer: Chemetron LOCATION: Near Room 0213 Area Controlled- 0211,0212,0213,0214,0221 Manufacturer: Amico LOCATION: Near Room 0213 Area Controlled- 0211,0212,0213,0214,0221 Manufacturer: Amico LOCATION: Near Room 0045 Area Controlled- Dental Rm. 0001,0004-0008,0011-0016,0021-0025,0035,0036,0038,0039,0040,0045-0050,0052,0054,0056,0058,0059Manufacturer:Chemetron LOCATION: Near Room 0660A Area Controlled- O2- MRI, MRI Holding, CT Scan, 0645,0665,0667,0668,0641,0644, 0673,0679,0681,0650,0637, 0621,0624,0626,0639 Manufacturer: Chemetron LOCATION: Near Prep 0099 Area Controlled- Room 0093, 0097, 0098 Manufacturer: Chemetron LOCATION: Near Room 0099 Prep Area Controlled 0099 Prep Manufacturer: Chemetron LOCATION: Inside 0410 D Area Controlled: 0410 OR Simulation Lab & 0411A ICU Simulation Lab Manufacturer: Amico LOCATION: Near Stair 10 Area Controlled: ED 1-13 Manufacturer: Chemetron LOCATION: Next to 1622 Area Controlled: 1641,1642,1643,1644A Manufacturer: Chemetron LOCATION: Across from 1E042 Bed 15 Area Controlled: ED 14-20 Manufacturer: Beacon Medaes LOCATION: Across from 1C019 Area Controlled: 1B017 Procedure Room Manufacturer: Beacon Medaes LOCATION: 2 East nurses Station Area Controlled 2206,2211,2212,2213,2214,2215, 2223,2224,2225,2226,2227,2231, 2238,2242,2243,2244,2245,2246, 2253,2254,2255,2256,2257,2262 Manufacturer: Amico LOCATION: Next to 2 North Nurses Station Area Controlled: 2025,2026,2027,2028,2029,2033,2040,2044,2045,2046,2047,2048 Manufacturer: Amico LOCATION: Nurses Station Area Controlled: 3205,3209,3210,3211,3212,3213, 3216,3220,3221,3222,3223,3224, 3229,3237,3242,3243,3244,3245, 3246,3255,3256,3257,3259,3263 Manufacturer: Amico LOCATION: Across from Room 3025 Area Controlled: 3006,3013A,3013B,3015,3020,3023,3024,3025 B-E,3032 Manufacturer: Amico LOCATION: Near Room 3041 Area Controlled 3034,3035,3040,3044,3047,3048, 3049,3050 Manufacturer: Amico LOCATION: Nurses Station 3072 Area Controlled: 3057,3060,3061,3066,3067,3068,3069 Manufacturer: Amico LOCATION: Near Room 36031 Area Controlled: 3603,3607,3609,3610, 3612,3613,3616 Manufacturer: Amico LOCATION: Near Room 3636 Area Controlled: For 02-3 West MA & Vac-3624,3627,3629, 3630,3633,3639 Manufacturer: Amico LOCATION: Near Room 3648 Area Controlled: 3642,3644,3646,3653,3656,3657,3660,3663 Manufacturer: Amico LOCATION: Near Room 3684 Area Controlled 3672,3674,3676,3678,3680,3685 Manufacturer: Amico LOCATION: Near Room 3403 Area Controlled: 3403,3408,3410,3411, 3413,3415,3417 Manufacturer: Amico LOCATION: Next to 3490 Area Controlled- 3474,3476,3479,3481,3483,3490 Manufacturer: Amico LOCATION: Next to 3439 Area Controlled: Oxygen-3 South, MA-3425,3427,3429,3431,3433, 3442,Vac-3425,3427,3429,3431, 3433,3442 Manufacturer: Amico LOCATION: Next to 3451 Area Controlled: 3444,3446,3448,3456, 3458,3460,3463,3465 Manufacturer: Amico LOCATION:4West across from 4628 Area Controlled: 4603,4607-4609,4611,4616,4624,-4627,4630,4634,4637,4639,4640,4643,4647,4650,4651,4653,4654,4662,4667-4669,4670,4671,4675 Manufacturer: Amico LOCATION: 4 North hallway outside 4042 Area Controlled: 4011,4015-4017,4019,4020,4032,4033,4039,4042,4043,4045,4048,4054,4058,4061,4062,4064,4065,4075,4076,4078,4079,4080,4084 Manufacturer: Amico LOCATION: 4 East Nurses Station Area Controlled: 4204,4208-4212,4224,4225,4227, 4228,4231,4235,4240,4244,4247, 4248,4250,4251,4264,4265,4266- 4268,4272,4273 Manufacturer: Amico LOCATION: 4 South outside Room 4474 Area Controlled: 4474 Manufacturer: Chemetron LOCATION: Outside EP Lab 4416 Area Controlled: 4416 EP Lab Manufacturer: Amico LOCATION: Outside 4414 Cath Lab Area Controlled: 4414 Cath Lab Manufacturer: Amico LOCATION: Next to 4419 Area Controlled: 4424 Manufacturer: Chemetron LOCATION: Across from 4427 Area Controlled: 4436, 4438, 4442, 4443, 4444, 4445, 4448, 4474 Manufacturer: Amico LOCATION: Near Room 5476 Area Controlled: 5460, 5461, 5462, 5463, 5464,5465, 5466, 5474, 5475, 5476 Manufacturer: Chemetron LOCATION: Near Room 5411 Area Controlled: PACU Room 5409 Manufacturer: Chemetron LOCATION: 5 South Nurses Station by Room 5423 Area Controlled: 5420,5421,5422,5423,5426,5430, 5436,5440,5443,5444,5445,5446 Manufacturer: Amico LOCATION: Next to Room 5669 Area Controlled: MICU CCU 5622,5623,5624,5626,5668,5669 Manufacturer: Amico LOCATION: Across from 5613 Area Controlled: MICU CCU 5613,5614,5616,5617,5618,5620 Manufacturer: Amico LOCATION: Across from 5638 Area Controlled: HICU SICU 5632,5633,5634,5635,5637,5638, 5646,5647 Manufacturer: Amico LOCATION: Across from 5658 Area Controlled: HICU SICU 5648,5649,5650,5651,5658,5659, 5661,5662,5663,5664 Manufacturer: Amico LOCATION: Near OR Schedule Board Area Controlled: Anesthesia Workroom 5037, Holding Beds 1-7 Manufacturer: Amico LOCATION: Near OR Schedule Board Area Controlled; Anesthesia Workroom 5037, Holding Beds 1-7 Manufacturer: Amico LOCATION: Across from 5014 Area Controlled: OR 2 Manufacturer: Amico LOCATION: Across from 5014 Area Controlled; OR 1 Manufacturer: Amico LOCATION: Next to 5218 Area Controlled: 5218 Manufacturer: Amico LOCATION: Next to 5221 Area Controlled I.R. Lab 5221 Manufacturer: Amico LOCATION: Next to 5222A Area Controlled: 5222A Manufacturer: Amico LOCATION: Next to 5223 Area Controlled: 5223 Manufacturer: Amico LOCATION: Across from 5224 Area Controlled 5224 Manufacturer: Amico LOCATION: Next to 5248 Area Controlled: 5248 Manufacturer: Amico LOCATION: Next to 5249 Area Controlled: 5249 Manufacturer: Amico LOCATION: Next to 5250 Area Controlled: 5250 Manufacturer: Amico LOCATION: Near OR 3 Area Controlled: OR 3 Room 5020 Manufacturer: Amico LOCATION: Near OR 4 Area Controlled: OR 4 Room 5025 Manufacturer: Amico LOCATION: Near OR 5 Room 5027 Area Controlled: OR 5 Room 5027 Manufacturer: Amico LOCATION: Near Room 5033 Area Controlled: OR 6 Manufacturer: Amico LOCATION: Across from Room 5038 Area Controlled: OR 7 Room 5034 Manufacturer: Amico LOCATION: Across from 5038 Area Controlled: OR 8 Room 5036 Manufacturer: Amico LOCATION: Next to 5251 Area Controlled: 5251 Manufacturer: Amico LOCATION: Across from 5233 Area Controlled: OR 9 5216 Manufacturer: Amico LOCATION: Next to 5217 Area Controlled: OR 10 5217 Manufacturer: Amico LOCATION: Near Room 5265 Area Controlled: 5263 & 5270 Manufacturer: Amico LOCATION: Across from Stair 9 Area Controlled: 5409 All Beds Recovery Room Manufacturer: Chemetron LOCATION: Across from Stair 1 in back hallway Area Controlled: Maintenance Valve East Wing Manufacturer: Chemetron LOCATION : Near Room 6033 Area Controlled: 6034 & 6037 Manufacturer: Chemetron MEDICAL GAS AREA ALARM PANELS TESTING for the following WLAVA building 500 locations: GROUND FLOOR LEVEL AREAS: Panel Location: Near Room 0213 Area Monitored: 0211, 0212, 0213, 0214, 0221 Brand/Mfr: Amico Model: Alert Panel Location: Near Room 0045 Area Monitored: Dental Rm. 0001, 0004-0008, 0011-0016, 0021-0025, 0035, 0036, 0038, 0039, 0040, 0045-0050, 0052, 0054, 0056, 0058, 0059 Brand/Mfr: Amico Model: Alert Panel Location: Near Room 0099 Prep Area Monitored: 0093, 0097, 0098 Brand/Mfr: Amico Model: Alert Panel Location: Near Room 0099 Prep Area Monitored: 099Prep Brand/Mfr: Amico Model: Alert Panel Location: Inside 0410 D Control Room Area Monitored: 0410 OR Simulation Lab & 0411A ICU Simulation Lab Brand/Mfr: Amico Model: L:CD FIRST FLOOR PANEL AREAS: Panel Location: Next to ED Beds 13 Area Monitored: ED 1-13 Brand/Mfr: Chemetron Model: Impact Panel Location: Next to 1B017 Area Monitored: 1B017 Procedure Room Brand/Mfr: Beacon Medaes Model: Total Alert 2 Panel Location: Next to 1E011 ED Bed 19 Area monitored ED 14-20 Brand/Mfr: Chemetron Model: Impact SECOND FLOOR PANEL AREAS: Panel Location:2 North next to Nurse Station Area Monitored: 2025, 2026, 2027, 2028, 2029,2033, 2040, 2044, 2045, 2046,2047, 2048 Brand/Mfr: AMICO Model:Alert Panel Location: 2 East Nurse Station Area Monitored: 2206,2211,2212,2213,2214,2215,2223,2224,2225,2226,2227,2231,2238,2242,2243,2244,2245,2246,2253,2254,2255,2256,2257,2262 Brand/Mfr: Amico Model: Alert Panel Location: 3 East Nurse Station Area Monitored: 3205,3209,3210,3211,3212,3213,3216,3220,3221,3222,3223,3224,3229,3237,3242,3243,3244,3245,3246,3255,3256,3257,3259,3263 Brand/Mfr: Amico Model: Alert Panel Location: Next to 3041 Area Monitored:3034, 3035, 3040, 3044, 3047,3048, 3049, 305 Brand/Mfr: Amico Model: Alert Panel Location: Inside 3025A Area Monitored: O2-3006, 3013A, 3013B, 3015,3020, 3023, 3024, 3025 B-E, 3032 MA & VAC-3025 B-E, 3032 Brand/Mfr: Amico Model: Alert Panel Location: 3 North Nurse Station Area Monitored: 3057, 3060, 3061, 3066, 3067, 3068, 3069 Brand/Mfr: Amico Model: Alert Panel Location: Next to 3637 Area Monitored: 3 West Brand/Mfr: Amico Model: Alert FOURTH FLOOR PANEL AREAS: Panel Location: 4 East Nurse Station Area Monitored: 4204,4208,4209,4210,4211,4212, 4224,4225,4227,4228,4231,4235, 4240,4244,4247,4248,4250,4251, 4264,4265,4266,4267,4268,4272, 4273 Brand/Mfr: Amico Model: Alert Panel Location: West Wing Area Monitored:4603,4607,4608,4609,4611,4616,4624,4625,4626,4627,4630,4634,4637,4639,4640,4643,4647,4650,4651,4653,4654,4662,4667,4668,4669,4670,4671,4675 Brand/Mfr: Amico Model: Alert Panel Location: Nurse Station Area Monitored:4011,4015,4016,4017,4019,4020,4032,4033,4039,4042,4043,4045,4048,4054,4058,4061,4062,4064,4065,4075,4076,4078,4079,4080,4084,4085 Brand/Mfr: Amico Model: Alert Panel Location: Inside Room 4419 Area Monitored: 4424 Brand/Mfr: Amico Model: LCD Panel Location: Across from 4427 Area Monitored:4436, 4438, 4442, 4443, 4444,4445, 4448, 4474 Brand/Mfr: Amico Model: Alert Panel Location: Inside Room 4415 Control Room Area Monitored: 4414 Cath Lab, 4416 EP Lab Brand/Mfr: Amico Model: Alert FIFTH FLOOR PANEL AREAS: Panel Location: Across from 5233 Area Monitored: OR 9 5216 Brand/Mfr: Amico Model: Alert Panel Location: Next to 5217 Area Monitored: OR 10 5217 Brand/Mfr: Amico Model: Alert Panel Location: Next to 5218 Area Monitored: 5218 Brand/Mfr: Amico Model: LCD Panel Location: Next to 5221 Area Monitored: I.R. Lab 5221 Brand/Mfr: Amico Model: Alert Panel Location: Across from 5223 Area Monitored: 5223 Brand/Mfr: Amico Model: Alert Panel Location: Across from 5224 Area Monitored: 5224 Brand/Mfr: Amico Model: Alert Panel Location: Next to 5248 Area Monitored: 5248 Brand/Mfr: Amico Model: Alert Panel Location: Next to 5249 Area Monitored: 5249 Brand/Mfr: Amico Model: Alert Panel Location: Next to 5250 Area Monitored: 5250 Brand/Mfr: Amico Model: Alert Panel Location: Next to 5251 Area Monitored: 5251 Brand/Mfr: Amico Model: Alert Panel Location: Across from 5014 Area Monitored: OR 1 Room 5016 Brand/Mfr: Amico Model: Alert Panel Location: Across from 5014 Area Monitored: OR 2 Room 5018 Brand/Mfr: Amico Model: Alert Panel Location: Outside OR 3 Area Monitored: OR 3 Brand/Mfr: Amico Model: Alert Panel Location: Outside OR 4 Area Monitored OR 4 Brand/Mfr: Amico Model: Alert Panel Location: Outside OR 5 Area Monitored: OR 5 Brand/Mfr: Amico Model: Alert Panel Location: Outside OR 6 Area Monitored: OR 6 Brand/Mfr: Amico Model: Alert Panel Location: Across from 5038 Area Monitored: OR 7 Brand/Mfr: Amico Model: Alert Panel Location: Across from 5038 Area Monitored: OR 8 Brand/Mfr: Amico Model: Alert Panel Location: Near OR Schedule Board Area Monitored Anesthesia Workroom 5037, Holding Beds 1-7 Brand/Mfr: Amico Model: Alert Panel Location: Next to room 5669 Area Monitored MICU CCU 5622, 5623, 5624, 5626, 5668, 5669 Brand/Mfr: Amico Model: Alert Panel Location: Across from room 5613 Area Monitored MICU CCU 5613, 5614, 5616, 5617, 5618,5620 Brand/Mfr: Amico Model: Alert Panel Location: Nurses Station Area Monitored: 5460, 5461, 5462, 5463, 5464, 5465, 5466, 5474, 5475, 5476 Brand/Mfr: Chemetron Model: Digital 2 Panel Location: 5 South Nurse Station by 5423 Area Monitored: 5 South, 5420, 5421, 5422, 5423, 5426,5430, 5436, 5440, 5443, 5444,5445, 5446 Brand/Mfr: Amico Model: Alert Panel Location: Across from 5638 Area Monitored HICU SICU 5632, 5633, 5634, 5635, 5637,5638, 5646, 5647: Brand/Mfr: Amico Model: Alert Panel Location: Across from 5658 Area Monitored HICU SICU 5648, 5649, 5650, 5651, 5658,5659, 5661, 5662, 5663, 5664 : Brand/Mfr: Amico Model: Alert Panel Location: Across from 5677 Area Monitored HICU SICU 5671, 5672, 5674, 5675, 5676,5689 : Brand/Mfr: Amico Model: Alert Panel Location: Next to 5265 Restroom Area Monitored: Rooms 5263, 5270 Brand/Mfr: Amico Model: Alert Panel Location: 5409 Recovery Desk Area Monitored: 5409 Recovery Brand/Mfr: Chemetron Model: Digital 2 SIXTH FLOOR PANEL AREAS: Panel Location: Nurse Station Area Monitored: 6034, 6037 Brand/Mfr: Chemetron Model: Digital 2 A corrective maintenance list shall be provided for all corrections (zone valves, area alarms, and outlets for example) with building, floor, location/ area description with building and room number of correction, Gas system corrected (O2, VAC, MA, etcetera), Discrepancy corrected, date repair and retest was completed, and repair technician name listed (technician s certification must be readily available and provided). WLA VA Medical Center: Building 500 Perform Annual Medical Gas Inspection to include inspecting all Source Equipment (Bulk Oxygen system, Medical Air Compressors, Vacuum Pumps, Nitrous Oxide Manifold, Nitrogen Manifold, Carbon Dioxide Manifold), Zone Valves, Master Alarm Panels, Area Alarm Panels, Wall Outlets. Provide a full detailed report with all findings. Perform Repairs to all discrepancies found during the Annual Inspections. Repairs are to be completed within 45 days of inspections. All repair parts to include O rings, faceplates, valve bodies, labels, zone valve gauges. Provide a full detailed repair report. Perform Annual Master Alarm Testing of all pressure switches and actuating devices from all source equipment. Exercise each device and verify proper activation at both Master Alarm panels. Provide a detailed report with switch settings and activation point. Perform Monthly testing of all Area Alarm Panels. Provide a detailed report of the setpoints and proper operation. Perform Semi-Annual flushing of Dental Vacuum Lines with cleaning fluid. Provide a detailed report listing all locations that were flushed. Perform Annual Filter changing of all Medical Air Filters located in interstitial. Provide a detailed report listing filter element number and location where it was installed. Check Nitrous Oxide Manifold bank pressures twice weekly. Record pressures and change cylinders as needed. Provide report as work is performed. Check Nitrogen Manifold bank pressures twice weekly. Record pressures and change cylinders as needed. Provide report as work is performed. Check Carbon Dioxide Manifold bank pressures twice weekly. Move replacement cylinders from loading dock to interstitial manifold as needed. Record pressures and change cylinders as needed. Provide report as work is performed. Perform Annual Boom and Articulating Arm Testing. Verify each medical gas connection inside the boom itself is not leaking. Test hoses for cracks and aging. Check to make sure hoses are not twisted. Perform corrections as necessary. Provide detailed report including photos of hoses and inside of booms. Alternate vaporizers weekly on Bulk Oxygen Main Vessel. Building 501 Perform Quarterly Factory recommended maintenance on Medical Air Compressor. Provide detailed report of items tested and replaced. Perform Quarterly Factory recommended maintenance on Dental Air Compressor. Provide detailed report of items tested and replaced. Perform Quarterly Factory recommended maintenance on Medical Vacuum Pumps. Provide detailed report of items tested and replaced. Perform Annual Factory recommended maintenance on Medical Air Compressor. Includes replacing inlet filters, in-line filters, belts, dryer mufflers, CO Sensor, Dew point probe. Provide detailed report of items tested and replaced. Perform Annual Factory recommended maintenance on Dental Air Compressor. Includes replacing inlet filters, in-line filters, belts, dryer mufflers, CO Sensor, Dew point probe. Provide detailed report of items tested and replaced. Provide detailed report of items tested and replaced. Perform Annual Factory recommended maintenance on Medical Vacuum Pumps. Includes changing oil, filters, replacing coupling inserts. Provide detailed report of items tested and replaced. Perform Quarterly Carbon Monoxide calibrations on CO Monitor. Replace Dew Point Probe Annually. Building 213 Perform Annual Medical Gas Inspection to include inspecting all Source Equipment (Bulk Oxygen system), Zone Valves, Master Alarm Panels, Area Alarm Panels, Wall Outlets. Provide a full detailed report with all findings. Perform Repairs to all discrepancies found during the Annual Inspections. Repairs are to be completed within 45 days of inspections. All repair parts to include O rings, faceplates, valve bodies, labels, zone valve gauges. Provide a full detailed repair report. Perform Annual Master Alarm Testing of all pressure switches and actuating devices from all source equipment. Exercise each device and verify proper activation at both Master Alarm panels. Provide a detailed report with switch settings and activation point. Perform Monthly testing of all Area Alarm Panels. Provide a detailed report of the setpoints and proper operation. Building 215 Perform Annual Medical Gas Inspection to include inspecting all Source Equipment (Bulk Oxygen system, Medical Air Compressors, Vacuum Pumps), Zone Valves, Master Alarm Panels, Area Alarm Panels, Wall Outlets. Provide a full detailed report with all findings. Perform Repairs to all discrepancies found during the Annual Inspections. Repairs are to be completed within 45 days of inspections. All repair parts to include O rings, faceplates, valve bodies, labels, zone valve gauges. Provide a full detailed repair report. Perform Annual Master Alarm Testing of all pressure switches and actuating devices from all source equipment. Exercise each device and verify proper activation at both Master Alarm panels. Provide a detailed report with switch settings and activation point. Perform Monthly testing of all Area Alarm Panels. Provide a detailed report of the setpoints and proper operation. Perform Quarterly Factory recommended maintenance on Medical Air Compressor. Provide detailed report of items tested and replaced. Perform Quarterly Factory recommended maintenance on Medical Vacuum Pumps. Provide detailed report of items tested and replaced. Perform Annual Factory recommended maintenance on Medical Air Compressor. Includes replacing inlet filters, in-line filters, belts, dryer mufflers, CO Sensor, Dew point probe. Provide detailed report of items tested and replaced. Perform Annual Factory recommended maintenance on Medical Vacuum Pumps. Includes changing oil, filters, replacing coupling inserts. Provide detailed report of items tested and replaced. Perform Quarterly Carbon Monoxide calibrations on CO Monitor. Replace Dew Point Probe Annually. Sepulveda Ambulatory Care Center Building 200 Perform Annual Medical Gas Inspection to include inspecting all Source Equipment (Bulk Oxygen system, Medical Air Compressors, Vacuum Pumps...

Full description on SAM.gov

Award Overview

Award Number

36C26224P1005

Award Amount (SAM.gov award notice)

$203.0K

Award Date

Mar 31, 2024

Awardee

Awardee UEI

Q9BDPCU9KMH3

Original Solicitation

Notice ID: c501cc4b2e8c45dc843a1ed7a701937a

Posted Date: Apr 5, 2024

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • 36C26226C0096
    CERTIFIED MEDICAL SALES, LLC
    Department of Veterans AffairsNAICS 811210
    $36.9KSigned Oct 27, 2026
  • 36C26224P0294
    CERTIFIED MEDICAL SALES, LLC
    Department of Veterans AffairsNAICS 811210
    $13.5KSigned Jul 9, 2026
  • 36C26225P1221
    CERTIFIED MEDICAL SALES, LLC
    Department of Veterans AffairsNAICS 811210
    $385.8KSigned Jun 17, 2026
  • 36C26226C0096
    CERTIFIED MEDICAL SALES, LLC
    Department of Veterans AffairsNAICS 811210
    $18.0KSigned May 28, 2026
  • 36C26225P1221
    CERTIFIED MEDICAL SALES, LLC
    Department of Veterans AffairsNAICS 811210
    $385.8KSigned Apr 27, 2026

Contacts

Documents

No documents available.

Lifecycle

Solicitation:36C26224Q0827
  1. Combined Synopsis
  2. Awarded

This opportunity has been awarded.

  1. Combined SynopsisMar 15, 2024

    J065--MEDICAL GAS SERVICES & ALARMS - POP (04/01/2024 - 03/31/2025)

    Notice df7172ec20354ee09c270cbc1c6749c5 on SAM.gov

  2. AwardedCurrentApr 5, 2024

    J065--MEDICAL GAS SERVICES & ALARMS - FY24 POP (04/01/2024 - 03/31/2025)

    Notice c501cc4b2e8c45dc843a1ed7a701937a on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Page 1 of This is a Sources Sought Notice (a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited. (b) Although "proposal," "offeror," contractor, and "offeror" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only. (c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as "proprietary" or "confidential," intended to restrict distribution will not be distributed outside of the Government, except as required by law. (d) This Sources Sought is issued by VISN 2 Contracting Office in Buffalo, New York for the purpose of collecting information about a requirement where the Contractor shall provide, preventative maintenance (PM) services on each piece of equipment outlined in this scope of work at the Albany VA Medical Center 113 Holland Avenue, Syracuse, NY 12208 . The VA is seeking to provide for this requirement as of January 1, 2027, The NAICS code identified for this requirement is NAICS Code 811210 - and NAICS Size standard of $34.0 Million. The requirement is detailed in the Statement of Work section of this document. (e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service, are encouraged to email a capability statement and full information to Stephanie.Decker2@va.gov and reference 36C24227Q0103. - Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, SAM UEID number and address, point of contact and social-economic. If contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy. The following information is required for determining procurement strategy and viability of sources: Set aside requirements have limitations on subcontracting. This service is located in Manhattan, NY and Brooklyn, NY. Provide your site location and supporting documentation. Given your location and proximity to the service site, how do you plan to accomplish self-performance of this work? If your intention is to subcontract work, what tasks will be performed by you as the prime contractor? What tasks will require a subcontractor due to your inability to perform them within your company? How many years experience does your company have in performing tasks of this nature, of this scope and this complexity? How many years of service do your proposed technicians have performing tasks of this nature, this scope, and this complexity? How many years does your proposed subcontractor have in performing tasks of this nature, this scope, and this complexity? How many jobs of this nature, of this scope and this complexity have you performed in the past five years? How many certified/licensed technicians does your company currently employ? - Contractors shall also identify any Federal Supply Schedules that may carry the desired services. - Contractors shall identify pertinent point of contact for company, contractor SAM UEID number for size standard and socioeconomic verification in SAM and SBA certification database (VetCert), as well as for any intended subcontractors. - Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs. - Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. - Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable. - Contractors shall include any relevant comments about the Attachment(s) if applicable. Below is the Limitation on Subcontracting Certificate of Compliance Clause. Please complete this as part of your response. 852.219-75Â VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction. As prescribed in 819.7011(b), insert the following clause: VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION) (a) Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that (1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.] (i) [ X] Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6. (ii) [ ] General construction. In the case of a contract for general construction, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (iii) [ ] Special trade construction contractors. In the case of a contract for special trade contractors, the contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following: (i) Referral to the VA Suspension and Debarment Committee; (ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and (iii) Prosecution for violating 18 U.S.C. 1001. (b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed. (c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror's bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. Certification I hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror]. Printed Name of Signee:_________________________ Printed Title of Signee: ____________________________ Signature: ____________________________________________ Date: _______________________ Company Name and Address:____________________________________________ Statement of Work (Abridged) Overview The Stratton VA Medical Center, Albany, NY has a requirement for Preventive Maintenance on their medical gas systems. We are currently seeking a full service and preventative maintenance contract. The contractor shall perform preventative maintenance (PM) services on each piece of equipment outlined in this scope of work. SCOPE OF WORK The contractor shall provide all labor, materials, and equipment necessary for a full preventive maintenance program. PM shall include annual inspection and testing of the equipment. It shall also include evaluation of the medical gas system in accordance with NFPA 99, VA specifications and the terms within this statement of work. Maintenance of Dental and Medical air compressors and Dental vacuum pumps ARE included in this contract. Work must be performed by only trained, and certified technicians on facility s Medical gas systems Period of Performance: The estimated period of performance shall be for one (1) Base Year of 12 months and four (4) 12-month option years. The Period of Performance reads as follows: Base Year 01/01/2027 12/31/2027 Option Year I 01/01/2028 12/31/2028 Option Year II 01/01/2029 12/31/2029 Option Year III 01/01/2030 12/31/2030 Option Year IV 01/01/2031 12/31/2031 Hours of Work: Facility s normal operating hours are between 7:00 AM to 4:30 PM Monday through Friday, except Federal Holidays. If circumstances arise that some work is to be performed outside normal business hours, the contractor shall communicate the proposed schedule with COR and Facility s Plumbing Shop Forman. Reports: The contractor will provide a copy of service report to the COR. The report will include a list of all preventive maintenance checks completed, as well as, identified problems and/or deficiencies found. The contractor will provide two inspection reports to the COR following completion of evaluation. The inspection documents will include, as a minimum, test parameters consisting of terminal performance, valve testing, cross connections, alarm testing, leak detection, equipment evaluation, contaminant, particulate and dewpoint testing. The service reports must be signed by both the service provider and the COR at completion of work. An electronic version of same shall be sent to the COR. Place of Performance: The work to be performed under this contract will be performed at Stratton VA Medical Center, 113 Holland Avenue, Albany, New York, 12208. PM Procedures: The contractor shall evaluate each existing oxygen, medical compressed air, vacuum and nitrous oxide systems. Sizing, flow, leaks, accessible piping, terminal performance, compressor or source configuration, valves, gauges, warning systems and alarms, back-up systems, vents, and contamination for compliance with current NFPA 99 specification and requirements. Contractor shall perform medical air purity test. Contractor employees shall be ASSE 6040 certified to perform maintenance and ASSE 6030 certified for inspection and testing. Minor repairs will be done while on station more difficult repairs or those needing additional parts will require a quote. There will be a system leak check using system gases and operational pressures done by the contractor where needed, tanks of appropriate gases will be used to facilitate testing. The system check will include originating equipment, patient rooms, clinic rooms, operating rooms (see Hours of Work), emergency rooms, and any room that contains outlets which are a part of the system. The unique inventory of outlets will be provided. Terminals: Terminal screws, front and back body O-rings, locking mechanism adjustment, lubrication, cleaning, flow/pressure measurement and locking mechanism verification. Valves: Rebuild leaking valves (ball type), cleaning and leaking inspection. Alarms: Contractor will provide lamp replacement, high- and low-pressure alarm calibration, cleaning and accuracy verification. Pro Flo Vacuum Enzyme Solution Injected to Aid SCFM Performance: Pro Flo enzyme solution will be injected into vacuum systems terminals, ringed and verified to maintain maximum SCFM with minimums of 3.0 SCFM required by NFPA, JCAHO Standards. Medical Oxygen System: Annually Test area alarms for proper pressure switch location and alarm function. Test Oxygen system for concentration and gaseous purity at each outlet. Test Oxygen for particulate contamination at least once in each zone. Tested with 0.45 micron filter device. Test Oxygen system for pressure at each zone. Test each Oxygen outlet for proper function, identification, adaptation and mechanical integrity. Identify leaking/malfunctioning outlets Identify outlets delivering substandard pressure/flow rates Test Oxygen zone shut-off valves for proper function, identification and mechanical integrity. Check Oxygen pipeline for proper identification labeling. Test each zone for available flow. Test operational pressure at each station outlet/inlet Test each critical care outlet operational pressure Test outlet flow rate and pressure drop with high demand at adjacent outlets. Test Oxygen system components for leakage. Check Oxygen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) Check for crossed lines. Medical Air System: Annually Test area alarms for proper pressure switch location and alarm function. Test Medical Air system gaseous purity. (Oxygen Concentration, Gaseous Hydrocarbons, Liquid Hydrocarbons, Carbon Monoxide, Carbon Dioxide, etc.). Test at source sample valve. Test Medical Air for particulate contamination at least once in each zone. Tested with 0.45 micron filter device Test source for dew point. Test Medical Air System for pressure at each zone. Test each Medical Air outlet for proper function, identification, adaptation, and mechanical integrity. Identify leaking/malfunctioning outlets Identify outlets delivering substandard pressure/flow rates Test Medical Air zone shut-off valves for proper function, identification, and mechanical integrity. Check Medical Air pipeline for proper identification labeling Test each zone for available flow. Test operational pressure tests at each station outlet/inlet Test each critical care outlet operational pressure test. Tested outlet flow rate and pressure drop with high demand at adjacent outlets Test Medical Air System components for leakage. Check Medical Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) Check for crossed lines. Medical Surgical Vacuum System: Annually Test area alarms for proper pressure switch location and alarm function Test each Vacuum inlet for available flow rate SCFM Test operational pressure tests at each station outlet/inlet Tested each Vacuum inlet for proper function, identification, adaptation, and mechanical integrity. Identified leaking/malfunctioning inlets Identified inlets delivering substandard vacuum/flow rate Test all Vacuum zone valves for proper function, identification, and mechanical integrity Check Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). Check for crossed lines. Nitrogen System: Annually Test area alarms for proper pressure switch location and alarm function Tested Nitrogen system for particulate contamination. Tested with 0.45 micron filter device Test Nitrogen system for pressure at each zone. Test Nitrogen system outlets for proper function, identification, adaptation, and mechanical integrity. Identify leaking/malfunctioning outlets Identify outlets delivering substandard pressure/flow rate Test Nitrogen zone shut-off valve for proper function, identification, and mechanical integrity. Check Nitrogen pipeline for proper identification labeling. Test Nitrogen control panels for leakage and proper operation. Check Nitrogen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.) Check for crossed lines. Check flexible connectors. Nitrous Oxide System: Annually Test area alarms for proper pressure switch location and alarm function Test Nitrous Oxide system for concentration Tested Nitrous Oxide system for particulate contamination. Tested with 0.45 micron filter device Test Nitrous Oxide system for pressure at each zone. Test each Nitrous Oxide outlet for proper function, identification, adaptation, and mechanical integrity. Identified leaking/malfunctioning outlets Identified outlets delivering substandard pressure/flow rates Test Nitrous Oxide zone shut-off valves for proper function, identification, and mechanical integrity. Check Nitrous Oxide pipeline for proper identification labeling. Test each Nitrous Oxide outlet for available flow. Test Nitrous Oxide pipeline components for leakage. Check Nitrous Oxide system components for proper installation (i.e.: Brazing, Labeling, - Hanging, etc.) Check for crossed lines. Check flexible connectors. Dental Air System: Annually Test Dental Air system for pressure Test Dental Air zone shut-off valves for proper function, identification, and mechanical integrity. Check Dental Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). Check for crossed lines Evacuation/WAGD: Semi-Annually Test area alarms for proper pressure switch location and alarm function Test inches (of mercury) of E-VAC at each zone Test each E-VAC inlet for available flow rate SCFM. Tested pressure at each inlet in all critical care areas. Tested for flow rate and pressure drop with high volume demand on adjacent inlets Test each E- V AC inlet for proper function, identification, adaptation, and mechanical integrity. Identify leaking/malfunctioning inlets Identify inlets delivering substandard vacuum/flow rate Test all E-VAC zone valves for proper function, identification, and mechanical integrity Check E-VAC system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). Check for crossed lines. Dental Vacuum System: Annually Check Dental Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). Check for crossed lines. Medical/Dental/Lab Air/Vacuum System Equipment Preventative Maintenance: Semi-Annually Examining items and to ensure that they maintain normal operating conditions Examining the seal fluid quality, quantity, temperature, and rate of rise against design specifications Examining the pump bearing and mechanical seals Inspection of all relays, transformers, contacts, sequencers, indicating lamps and the wiring in the panel for faults Greasing of the air and vacuum pump systems in accordance with manufacturer's specifications Inspection of demisters Cleaning of all flow control valves, strainers, suitcase separators so that they are free of debris to insure the pump reliability and longevity. Replacement of failed controls. These items include but are not limited to solenoid valves, flow switches, and air unload valves. Replacement parts shall be new. Check and replace belts if needed and equipped Repair Procedures: Emergency Repairs: An emergency repair shall be defined as one in which any portion of the medical gas, compressed air and vacuum systems is shutdown or is inoperable due to breakdown, malfunction, fire, or any other condition determined by the Contracting Officer s Representative (COR) or authorized Government inspector that presents an immediate danger to personnel or threatens to impair the mission of the facility. A mechanic shall be on the site ready to service the medical gas, compressed air, and vacuum systems within two (2) hours of receiving a request for emergency service call, 24 hours a day, 7 days a week. After receiving a request for emergency service, the work shall be prosecuted continuously until the emergency is arrested. Urgent Repairs: An urgent repair shall be defined as one in which the medical gas, compressed air and vacuum system may become inoperable due to malfunction or need for servicing or threatens to impair the mission of the facility. A mechanic shall be on the site to service the medical gas, compressed air, and vacuum systems within four (4) hours of receiving a request for urgent service, the work shall be prosecuted continuously until the urgent situation is arrested. Examples of urgent repairs includes: Medical gas system leaking seeping or weeping, power fluctuation affecting the system, or medical gas system no longer functioning. System shut down/standby: The government may direct the contractor to shut down the system at its convenience to allow other Government or contract work to be performed in that area. The contractor shall be available 24 hours a day, seven days a week. The Government will provide the contractor with a 24-hour notice of shut down service. At such time, the contractor will be provided the time and date of the shutdown, to include when the equipment will be back to operating status. The contractor is not required to be at the job site during the period the system is shutdown. The Contractor will be compensated for the actual time it takes to shut down the system and the actual time it takes to turn-on the system. Standby requires the Contractor to be at the job site during specified periods, as directed by the COR. Standby may be required when system is shutdown or when other work (i.e. construction, electrical outages, etc.) may adversely affect the system. The Contractor will be compensated for the entire standby period.
90%
Market Research11/12/2026
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this-- sources sought announcement must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) Unique Entity ID (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. The Loma Linda VA Health Care System (LLVAHCS) located at 11201 Benton St. Loma Linda, CA 92357 is seeking a potential qualified contractor that can provide: Preventive Maintenance, inspection, and repair services for various Government owned scopes. Important information: The Government is not obligated to/nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service-Disabled Veteran Owned Small Business set aside. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 811210 Electronic and Precision Equipment Repair and Maintenance 34 Million. *******DRAFT*******DRAFT******DRAFT*******DRAFT******* D.1 STATEMENT OF WORK TITLE: Preventive Maintenance, inspection, and repair services for various Government owned scopes at the Loma Linda VA DESCRIPTION OF WORK: The Contractor shall furnish all labor, transportation, materials, tools, supplies and spare parts to perform repair of scopes on an as needed basis. Equipment included are but not limited to the following: Rigid endoscopes, Flexible Endoscopes, GI Video Endoscopes, GI Specialty Scopes, Medical Bronchoscopes, Cystoscopes, Ultrasound Probes, Laryngoscopes, Rhino Laryngoscopes, Naso Laryngoscopes, Rhino-Laryngo fiberscope, Ureterorenoscopes, Light Sources, Hand Pieces, Video Processors, Surgical Endoscopes, Surgical Bronchoscopes, Surgical Fiberscope, Surgical Laparoscopes, Surgical Specialty Scopes, Surgical Cameras, Surgical Specialty Cameras, Surgical Telescopes, Urology Fiberscope, Urology Specialty Scopes, Ultrasound Probes for the VA Loma Linda Healthcare System (VALLHS). Manufacturers include, but are not limited to: Olympus, ABC Lab, Pentax, Verathon, Aleet Commercial, Terumo, Maquet Medical, Siemens, Karl Stortz, Intuitive surgical, Bryan Corp, Richard Wolf GMBH, Stryker, Smith and Nephew, Given Imaging, Gyrus, Olympus, Siemens, nd Conmed. SCOPE: In the context of this contract, Equipment refers to any patient critical instrumentation that is used in surgical or endoscopic procedures. Equipment as used herein includes the following: Rigid endoscopes Powered surgical hand pieces and related instrumentation (pneumatic and electrical) Endoscopic cameras and related equipment Specialty surgical instrumentation including phacoemulsification hand pieces (Phacos), harmonic scalpel hand pieces, laparoscopic instruments Flexible endoscope Ultrasound Probes CONTRACTOR RESPONSIBILITIES: The Contractor shall service and repair a variety of Equipment as detailed above as ordered by the Contracting Officers Representative (COR) participating facility of the VA. The Contractor shall furnish all labor, transportation, materials, tools, supplies and spare parts required to perform service and repairs on a variety of Equipment . Contractor shall complete all repairs/service within the time specified below: Minor Repairs 24 through 72 hours Major Repairs 2 days through 5 days Extreme Damage 3 days of more Contractor shall notify the COR if repair/service cannot be completed within the time specified above and of all cases where extreme damage has been found. Contractor shall utilize only parts of original manufacturer design and specifications or equal thereto. Used parts are prohibited. Contractor shall ensure the equipment that is being repaired/ serviced shall have a tag placed on the equipment for identification purposes with the information provided by the COR. COR of the facility shall initiate an order for repairs/services. COR shall provide written documentation to the Contractor as to the defect of the equipment and the following equipment information: VA Healthcare System Facility Name Location of equipment to be repaired (room and/or building number) Type of equipment Make of equipment Model number of equipment Serial number of equipment Purchase order number Description of service or repairs that may be needed COR name, address and phone number Contractor shall inspect the equipment and determine the needed repairs/services. Prior to any repairs/service being performed and/or price/cost exceeding the terms of this contract. Contractor shall obtain verbal or written approval from the COR. Verbal and/or electronic approval from the COR shall be documented with the date and time by the Contractor. Upon approval from the COR, Contractor shall proceed with the repair/service of the equipment. Contractor shall determine and assign the appropriate service technician to perform services, repairs, upgrades, modifications and/or maintenance and inform the COR. Contractor shall pick up at no cost and deliver FOB destination to the ordering facility, equipment to be repaired/serviced. Each shipment shall be properly packaged and be accompanied by an itemized shipping list and equipment information. VA facility ordering repair/service shall not be responsible to check/verify the status of the equipment being repaired/ serviced. Contractor upon receipt of the equipment for repair/service shall immediately report to the COR its inability to repair/service the equipment received Contractor shall provide the COR an electronic copy of the field service report after every PM or repair within 7 calendar days. At a minimum, this report must contain a detailed description of any services or repairs performed for each item of equipment, and must also include a listing of replacement parts, when applicable, total hours of service, safety check, performance data, and the date. The report will also include any Vendor recommendations necessary to maintain the equipment in optimum operating condition. Service Technician shall document and report to the COR any unsafe conditions or signs of misuse or abuse in regard to this medical equipment. Invoicing and Shipping Documentation: Contractor shall provide a delivery ticket or invoice with the repaired/ service equipment, and shall contain the following minimum information: Name of Contractor Contract number Date of service Purchase order number Itemized list of service or repairs Quantity, unit price and extension of each item, less applicable discounts Date of delivery or shipment Only those services specified herein are authorized under this contract. Before performing any service or repairs of a non-contract nature, the COR or Contracting Officer must be advised of the reasons for this additional work. If appropriate, the Contracting Officer or his/her designee may authorize the additional services or repairs under a separate purchase authorization. The Vendor is cautioned that only the Contracting Officer may authorize additional services or repairs and that reimbursement will not be made unless this prior authorization is obtained. Contractor shall be engaged full-time in the maintenance and repair of the equipment listed in Section I. Contractor shall have access to complete service manuals, access to software diagnostic keys, and Contractor shall, without exception, provide all hand tools, diagnostic test equipment, ladders, and anything else necessary to perform the work. PLACE OF PERFORMANCE: The contractor shall provide services at the government facilities located below: Facility Name Address VALLHS 11201 Benton St., Loma Linda, CA 92357 WORKING HOURS: All scheduled pickup and delivery shall be accomplished during working hours generally between 7:30AM and 4:00PM Monday through Friday, National Holidays excluded, unless other arrangements have been made by the ordering COR with the Contractor. Contractor must check-in with the COR if coming on-site. All service/repairs will be performed during stipulated hours of coverage unless requested or approved by the COR. GOVERNMENT HOLIDAYS: The Vendor is not required to provide service on the following National holidays, not shall the Vendor be paid for these holidays. The following national holidays observed by the Federal Government: New Year s Day 1 January Martin Luther King s Birthday Third Monday in January President s Day Third Monday in February Memorial Day Last Monday in May Independence Day 4 July Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day 11 November Thanksgiving Day 4th Thursday in November Christmas Day 25 December If a holiday falls on Sunday, the following Monday shall be observed as the National Holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a National Holiday by U.S. Government agencies. Also included would be any day specifically declared by the President of the United States. OVERTIME AND HOLIDAYS: Any overtime and/or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government. LOANER SCOPES IF REQUESTED: When requested by the COR, contractor shall ship and deliver, at no additional cost, loaner scopes within 48 hours of written notification to the Contractor. REPORTING: Services shall be performed during normal working hours, the Contractor shall report upon arrival to the Biomedical Engineering Department for all the facilities identified in the solicitation, to arrange all services. In addition to signing in, Contractor personnel shall identify himself to the COR before proceeding to the job site. This check in is mandatory. After the work is completed, the Contractor is to submit in writing, complete report of service rendered to the Biomedical Engineering Dept. As a minimum, this report must be containing a detailed description of any service performed and any recommendations necessary to meet regulations. WARRANTY: Contractor shall provide a warranty for ninety (90) days after acceptance for repaired equipment. TEST EQUIPMENT: The VA shall not furnish parts and/or test equipment for the performance of this contract. It is the responsibility of the contractor to have the appropriate equipment and/or supplies necessary to complete the work. SUPPORT: The contractor shall pick up the Scope on-site within 1 business day, excluding weekends and federal holidays, during normal government business hours. Name: _________________________________________________________ Telephone No: ____________________________Fax No: _____________________ Email: ________________________________________________ CHANGES: The Contractor is advised that only the Contracting Officer, acting within the scope of the contract has the authority to make changes which affect the contract in terms of quality, quantity, price or delivery. In the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered to have been made without authority and no adjustment shall be made in the contract price to cover any increase in costs as a result thereof. ORDERING ACTIVITIES AND OFFICERS: The Contractor shall not accept any instructions issued by any other person(s) other than the Contracting Officer or COR acting within the limits of his/her authority. CONTRACTOR S RESPONSIBILITIES: The Contractor shall maintain personal liability and property damage insurance prescribed by the laws of the Federal Government. He/she shall take all precautions necessary to protect persons and property from injury or damage Contractor shall comply with all VA safety standards, and manufacturer s/industry standards. PERSONNEL QUALIFICATIONS/EXPERIENCE CRITERIA: Contractor personnel shall be fully qualified, trained and experienced to perform repairs on the various Scopes. The Contractor shall be responsible for protecting the personnel furnishing services under this contract. To carry out this responsibility, the Contractor shall provide the following for these personnel: Worker s Compensation Health Examinations Income Tax Withholding, and Social Security Payments The Contractor shall follow all existing local, state, federal and/or union laws/regulations relevant to fringe benefits and premium pay for their employees. Contractor personnel shall not be considered VA employees for any purpose. BADGES AND PARKING: All Contractor personnel are required to wear identification (I. D.) badges issued by the VA Police Station during the entire time they are on the VA facility grounds. All Contractor personnel are also required to wear Vendor ID Badges noting Contractor Name, Name of personnel, and photo. It is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the individual VA Healthcare System Police Station. VA shall not validate or make reimbursement for parking violations of the Contractor's personnel under any circumstance. INVOICE: The invoice MUST be itemized to include the following information listed below. Any information listed below that is not provided on an invoice will render that invoice incomplete and the invoice will be returned for immediate correction. Time period being invoiced for Description of services Unit Cost Billed Extended amount due Invoice number, and date Contract and obligation number Notice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be certified by the Small Business Administration; Veteran Small Business Certification, (VetCert) https://veterans.certify.sba.gov/. All interested Offerors should submit information by e-mail to: catherine.fernandezpedernera@va.gov . All information submissions to be marked Attn: Catherine Fernandez, Contract Specialist and should be received no later than 10:00 AM PST on September 30, 2026.
81%
Market Research09/30/2026
This is an INTENT TO SOLE SOURCE NOTICE only. The Department of Veteran Affairs, Network Contracting Office (NCO) 16, intends to issue a sole-source contract under the authority of 41 U.S.C. § 3304(a)(1) - FAR 6.302-1 (only one responsible source and no other supplies or services will satisfy agency requirements), to Spectrum Dynamics Medical Inc. 301 N. Cattlemen Rd. Suite 109 Sarasota, FL 34232. Spectrum Dynamics Imaging Systems will be posted to contracting opportunities from 10/02/2026 through 10/12/2026 under NAICS 811210. This service contract is to ensure that Spectrum Dynamics Imaging Systems at the Southeast Louisiana Veterans Health Care System, New Orleans, LA 70119. This action will result in a firm-fixed-price service contract. The period of performance shall be for Base year of twelve (12) months beginning October 19, 2026, to October 18, 2027. This notice of intent is not a request for quotations; interested parties may express their interest by providing a capabilities statement not later than 10/12/2026 at 13:00 CDT, to christopher.rossi2@va.gov When responding to this announcement, respondents should refer to number 36C25627Q0024, Notice of Intent Spectrum Dynamics Medical Inc in the subject line. The capabilities statement must provide clear and unambiguous evidence to substantiate the capability of the party to provide the required services. Responding as an interested party under the www.sam.gov website does not constitute convincing evidence of capabilities. A determination not to compete this proposed contract upon responses to this notice is solely within the discretion of the Government. Verbal and facsimile responses are not acceptable and will not be considered. All interested parties are reminded to be registered with System for Award Management (SAM) at https://sam.gov/SAM/ in order to be eligible for award of Government contracts. No telephone calls will be accepted. If after October 12, 2026 @ 13:00 CDT, no viable responses have been received in response to this announcement, NCO 16 shall negotiate solely with Spectrum Dynamics Medical INC. The Government anticipates the award of a firm-fixed-price contract. A determination by the Government whether to compete the proposed requirement shall be based upon responses received and is solely within the discretion of the government. Information received shall be considered solely for the purpose of determining whether to conduct a competition.
77%
Special Notice10/12/2026
76%
Solicitation11/25/2026
Department of Veterans Affairs (VA) Network Contracting Office 08 (NCO 08) hereby gives notice of the Government s intent to negotiate a sole source, Fixed-Priced Purchase Order with only one source Stryker Sales LLC, the Original Equipment Manufacturer (OEM), for the provision of ProCare preventive maintenance and repair services for existing Stryker Neptune Rover Medical Surgical Equipment located at the Bay Pines VA Healthcare System and Lee County Healthcare Clinic. This action is for services for which the Government intends to solicit and negotiate with only one source under the authority of Revolutionary FAR Overhaul 12.102 (a) and 41 USC §1901, only one will meet the Government s needs. Only one source is capable of responding due to the unique or specialized nature of the supplies and/or services. It is the Government s belief that the proposed candidate is the only authorized provider of the services and parts that can meet the agency s needs. This notice of intent is not a request for competitive quotes. Telephone requests will not be accepted. However, any business that believes it can meet the scope of work may give written notice to Gwendolynn.McCranely@va.gov by 10:00AM Eastern Standard Time on November 25, 2026. All responsible sources may submit a bid, proposal, or quotation which shall be considered by the agency. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirement. Responses will be considered by the Government; however, a determination by the Government not to compete the proposed acquisition based upon responses of this notice is solely within the discretion of the Government. THIS SYNOPSIS DOES NOT COMMIT THE GOVERNMENT TO CONTRACT FOR ANY SUPPLY OR SERVICE. THE GOVERNMENT WILL NOT PAY FOR ANY INFORMATION OR ADMINISTRATIVE COSTS INCURRED IN RESPONSE TO THIS SYNOPSIS.
76%
Pre-Solicitation11/25/2026

Additional Details

Solicitation Number

36C26224Q0827

Archive Date

May 5, 2024

Office Address

Gilbert, AZ, 85297