GovChime
Notice ID: 16189a34ed154b799dfa2c0845673ee7Award NoticeAwarded

J059--PM&R SVC for 30 Kilo-Volt Ampere Uninterrupted Power Supply -W/WD

Awarded on March 31, 2025. Full description on SAM.gov.

Awarded tounder 36C26225C0156 (source: SAM.gov award notice)• $42.3K

Overview

Posted
October 28, 2025
Notice type
Award Notice
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
NAICS
811210: Electronic and Precision Equipment Repair and Maintenance
Agency
Department of Veterans Affairs

Notice details

Office
262-NETWORK CONTRACT OFFICE 22 (36C262)
Place of performance
Department of Veteran Affairs VA San Diego Healthcare System ASPIRE Center 2121 San Diego Avenue, San Diego, 92110
PSC
J059: MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
Last updated
Aug 21, 2026
Award date
Mar 31, 2025
Award amount (SAM.gov award notice)
$42.3K

Identifiers

Solicitation number
36C26225Q0465
Notice ID
16189a34ed154b799dfa2c0845673ee7
Award number (PIID)
36C26225C0156

Description

PM&R SVC for 30 Kilo-Volt Ampere Uninterrupted Power Supply Questions and answers to solicitation 36C26225Q0465 UPS Unit Details: Make & Model Powerware #9355-30 Serial Number(s) #BG436KXX06 Battery Details: Make & Model CSB Battery Co. Ltd. 108 units #HR 123W (internal) 144 units #HR 12120W(external) Quantity required for replacement #252 units Service Requirements Clarifications: Does the semi-annual service include load testing or just visual inspections? Yes it is included from the list Inspect all Printed Circuit Board (PCB) boards for cracks or damage. Check and record input/output voltage and amperage readings. Calibrate metering. Perform safety shutdown function tests. Test and record line/load voltages and amperages. Re-torque all electrical connections. Exercise all circuit breakers. Inspect all Alternating Current (AC) & Direct Current (DC) electronics for damage. Check and record each battery voltage, impedance, and general condition. Provide VA COR with a detailed maintenance report. Are there specific compliance or reporting requirements beyond standard preventive maintenance? per NFPA 111 Any historical maintenance logs or known issues that should be considered? yes, shall be need all 4) Battery Specifications Could you provide the model number and/or specifications of the 252 batteries that require replacement? Number of Internal Battery: 108 BATTERIES 5)MANUFACTURER: CSB BATTERY CO, LTD MODEL #: HR 1234W CELLS PER UNIT: 6 VOLTAGE: 12 VOLTS CAPACITY: 34W @ 15 minute-rate to 1.67V per cell @ 25 degree centigrade MAX DISCHARGE CURRENT: 130A WEIGHT: APPROX 2.5 kg (5.51 lbs) TERMINAL: F2-FAST ON TAB 250 Number of External Battery: 144 BATTERIES MANUFACTURER: CSB BATTERY CO, LTD MODEL #: HR 12120W CELLS PER UNIT: 6 VOLTAGE PER UNIT: 12VOLTS CAPACITY: 120W @ 15 MIN RATE TO 1.67V/CELL @ 25 DEGREE CENTIGRADE MAX DISCHARGE CURRENT: 400A 6)The price/ cost schedule does not have a section to quote the replacement of the batteries, just the UPS PMs. Will the VA create an amendment to input a CLIN for the battery replacements? All is included in the quotation. 7)Battery Replacement Schedule The solicitation specifies a full battery replacement in the Base Year. Could you confirm whether another full replacement is anticipated in Option Year 4 (OY4), which aligns with standard battery lifecycle expectations? 5 years is life cycle and shall be done on base year. 8)Emergency Service and Repairs Should emergency service visits and repairs be included in the preventive maintenance pricing, or should they be quoted and billed separately on an as-needed basis? This is only for Preventive maintenance and emergency will be quoted as needed..

Full description on SAM.gov

Award Overview

Award Number

36C26225C0156

Award Amount (SAM.gov award notice)

$42.3K

Award Date

Mar 31, 2025

Awardee

Awardee UEI

LBURXFBLNEQ3

Awardee CAGE Code

9P4W9

Awardee Address

LONG BEACH, CA 90807, CA

Original Solicitation

Notice ID: 16189a34ed154b799dfa2c0845673ee7

Posted Date: Oct 28, 2025

Original Response Deadline: Not specified

Contacts

Contracting Officer

Primary Contact

Jessica Brooks
Contract Specialist

Documents

Select documents to download

Showing 8 of 8 items

Document
Source
Agency
Posted Date
File Size
Actions
PresolicitationVETERANS AFFAIRS, DEPARTMENT OFOct 28, 2025-
SolicitationVETERANS AFFAIRS, DEPARTMENT OFOct 28, 2025-
SolicitationVETERANS AFFAIRS, DEPARTMENT OFOct 28, 2025-
SolicitationVETERANS AFFAIRS, DEPARTMENT OFOct 28, 2025-
SolicitationVETERANS AFFAIRS, DEPARTMENT OFOct 28, 2025-
SolicitationVETERANS AFFAIRS, DEPARTMENT OFOct 28, 2025-
SolicitationVETERANS AFFAIRS, DEPARTMENT OFOct 28, 2025-
Award NoticeVETERANS AFFAIRS, DEPARTMENT OFOct 28, 202522.33 KB

Lifecycle

Solicitation:36C26225Q0465
  1. Pre-Solicitation
  2. Solicitation
  3. Awarded

This opportunity has been awarded.

  1. 2×
    Pre-SolicitationFeb 7, 2025

    J059--PM&R SVC for 30 Kilo-Volt Ampere Uninterrupted Power Supply

    Notice eeafe606edb641e79f5165ee5f2ce067 on SAM.gov

  2. 3×
    SolicitationFeb 12, 2025

    J059--PM&R SVC for 30 Kilo-Volt Ampere Uninterrupted Power Supply

    Notice ab76b0ad00aa4abdb1eacbff37c54b14 on SAM.gov

  3. AwardedCurrentOct 28, 2025

    J059--PM&R SVC for 30 Kilo-Volt Ampere Uninterrupted Power Supply -W/WD

    Notice 16189a34ed154b799dfa2c0845673ee7 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C26225Q0465

Archive Date

Nov 12, 2025

Office Address

Gilbert, AZ, 85297