Notice ID: a9590467ee1f405396afb5d689bd30b7PresolicitationArchived
6515--FES Cycling System
Archived on January 14, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 4:00 PM PST
- Posted
- December 1, 2025
- Notice type
- Presolicitation
- NAICS
- 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing
- Agency
- Department of Veterans Affairs
Notice details
- Office
- 262-NETWORK CONTRACT OFFICE 22 (36C262)
- Place of performance
- Phoenix VA Health Care System, Phoenix, Arizona, 85012
- Last updated
- Nov 5, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- 36C26226Q0127
- Notice ID
- a9590467ee1f405396afb5d689bd30b7
Description
This request for information (RFI/Sources Sought) is issued solely for information and planning purposes. This is NOT a solicitation. THERE ARE 19 QUESTIONS AT THE BOTTOM OF THIS DOCUMENT. PLEASE ANSWER THEM COMPLETELY AND THOROUGHLY. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI in accordance with (IAW) Far 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1,250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The Department of Veterans Affairs (VA) is seeking sources capable of providing a Functional Electrical Stimulation (FES) cycling system. (1) Manufacturer: Myolyn, Incorporated Item Description: Myocycle V2 Pro Plus Quantity: 1 Must Include: On-site 1-Hour training Manufacturer Part Number: 2296 Equal to product Information: Main component: Functional Electrical Stimulation (FES) cycling system Salient Characteristics Must: Have at least 10 integrated functional electrical stimulation therapy channels. Have at least a 10 touchscreen integrated controller. Have an electrode set. Support a weight capacity up to 120 kilograms. Have an arm crank length of at least 117 millimeters. The list of salient characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. If your company is interested and capable of providing the required supplies, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) As defined in FAR Part 52.225-1 regarding the Buy American Act, please list the country of origin for each line item. (2) Submit your capabilities statement illustrating how your organization can/cannot meet the list of salient characteristics requirements. For instances where your company cannot meet the salient characteristics requirement(s), please explain. For instances where your company can meet the salient characteristics requirement(s), please show how your company meets/exceeds each requirement. (3) Please review the list of salient characteristics requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (4) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (5) Is your company considered small under the NAICS code identified in this RFI? (6) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of salient characteristics? (7) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (8) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (9) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (10) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (11) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained. (15) Does your organization offer a leasing solution? Please elaborate. (16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (19) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to Nathan.munson@va.gov. Telephone responses will not be accepted. Responses must be received no later than Monday, December 15th, 2025 by 4:00 PM EST. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.
Award Overview
Possible prior contract
Inferred, not confirmedInferred, not confirmed. Matched by agency, NAICS, place of performance and end-date proximity. This is a candidate, not the contractor of record.
Vendor
OLYMPUS AMERICA INCContract end date
Sep 30, 2026
NAICS
334510
Agency
Department of Veterans Affairs
Dollar amounts are not shown for inferred matches because the link is heuristic. Open the award below to check it.
Contacts
Contracting Officer
Primary Contact
Documents
Lifecycle
- 3Version 3PresolicitationArchivedCurrent
6515--FES Cycling System
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS code is 334519 - Other Measuring and Controlling Device Manufacturing, with an SBA small business size standard of 600 employees. Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The purpose of this procurement is to acquire and install a fully automated, weight-based inventory management system, brand name or equal to PAR Excellence, for the VA Phoenix Healthcare System. The system is intended to provide accurate, real-time perpetual inventory visibility while minimizing end-user data entry and supporting timely replenishment of medical and surgical supplies. The anticipated requirement includes all equipment, scales, controllers, storage products, mounting hardware and accessories, software licenses, interfaces, implementation services, installation, configuration, testing, training, warranty, monitoring, maintenance, and technical support necessary to deliver a fully operational system at the facility's designated primary and secondary supply locations. For market-research and planning purposes, the anticipated configuration is approximately 26 PAR Bins Replenish software licenses, 3,571 scales of various types and capacities, 27 Ethernet replenishment controllers, related hardware accessories, storage bins, shelving, cabinets, mobile louvered panel units, and associated implementation and training services. Final quantities and configurations are subject to change. At a minimum, the proposed solution must provide an HL7 interface that communicates with the VA Generic Inventory Package (GIP) in VistA and must have an approved VA Information Technology Authority to Operate (ATO) at the time of offer. Contractors must be able to validate interoperability with VA GIP through the HL7 interface prior to award. The system must support unlimited users and multiple permission levels; provide access from multiple points on VA-furnished computers; produce Excel or text-delimited reports; display equipment and materials-management status; provide item-location, PAR-level analysis, consumption data, order, reconciliation, due-in/due-out, discrepancy, and inventory-value reporting; and generate pick-ticket information based on PAR levels, reorder points, and emergency stock levels. The system must be compatible with existing shelving, cabinets, carts, and other storage infrastructure; accommodate medical and surgical products of varying size, thickness, and weight, including products up to approximately 3 feet long by 2 feet wide and 20 pounds; and permit VA employees to recalibrate the system for different package quantities. The contractor must install and configure the required software on VA-furnished equipment, provide staff training, furnish a one-year license agreement with software upgrades, and provide 24 hours per day, 7 days per week, 365 days per year support. Support must include at least four remote equipment-functionality checks every 24 hours, response to service calls within 24 hours, and repair or replacement of covered equipment or hardware within 48 hours when damage or defect is not attributable to VA personnel. Installation is anticipated to begin no later than 70 days after contract award and be completed no later than 400 days after award, subject to facility deployment planning and required facility tasks. Deliverables will be shipped to VA Phoenix Healthcare System, Main Warehouse (ATTN: Prentiss Logan), 650 E Indian School Road, Phoenix, AZ 85012, with notice to the Contracting Officer's Representative five business days before shipment. The current independent planning estimate derived from the attached vendor quotation is $1,502,945.49, inclusive of turnkey installation. This amount is provided solely to describe the anticipated magnitude of the requirement for market-research purposes and does not constitute a Government estimate, commitment, or solicitation price. STATEMENT OF WORK 1. Background VA Phoenix Healthcare System has used cabinet-based Point of Use (POU) systems to manage inventory levels within our facility s supply areas. Our facility s current supply system process relies heavily on clinical staff entering quantities as they pull product. When they fail to enter, or enter incorrect quantities, our process fails. This leads to workload issues, as Supply Techs must be pulled from current duties to perform urgent resupply requests to affected areas. This also presents potential patient safety issues during emergency situations if stock is not available due to inaccurate stock level information. Further, the current supply process is labor and time intensive. This is compounded in times of heavy workload due to availability of supply personnel and/or hospital patient load, increasing risks associated with patient care / safety. VA Phoenix Healthcare System is looking for a fully automated weight-based inventory management system that does not require end users to input data or interface with the system to increase or decrease material items stocked or consumed by the user. The station requires a system that removes or heavily limits the amount of human interface required to maintain accurate and real time inventories. This creates a more accurate and efficient system while simultaneously addressing the patient safety / care concerns mentioned above, eliminating the frequent emergent supply requests created by inadequate inventory management systems. A fully automated weight-based inventory management system will augment the supply chain s management effectiveness and timeliness with resupply inventory while decreasing the workload of supply personnel. It will also improve the overall patient care throughout the facility, particularly in the cardiac catheterization and electrophysiology labs, by effectively maintaining appropriate periodic automatic replacement levels. 2. Scope The scope of this requirement is to obtain and install an automated inventory management system at VA Phoenix Healthcare System, ensure system is fully operational, and fully train staff to be knowledgeable on the use of system. This is a brand name or equal requirement; a Fully Automated Weight-Based Inventory Management System or equal to PAR Excellence. Contractors must provide a brand name or equal that meets or exceeds the physical, functional, and performance of listed characteristics described in this Statement of Work. Contractor must show clear and compelling, and convincing evidence that all equal to items meet all required salient characteristics including brand name and model numbers IAW FAR 52.211-6 Brand Name or Equal. The proposed software must have HL7 interface at the time of offer. Contractors must validate and prove that the system communicates to VA Generic Inventory Package (GIP) in VistA through HL7 interface prior to award. Software must have an approved IT Authority to Operate (ATO) on the VA system at the time of offer. 3. Specific Tasks 3.1. Installation To supply and install all equipment and parts, to include mounting hardware, if necessary for a weight-based inventory management system at VA Phoenix Healthcare System s primary and secondary locations. Installed equipment shall have a one-year full equipment replacement warranty for defects or damage not caused by VA personnel. Installation shall not include disassembly of existing storage devices. Installation shall include costs on any additional equipment required for new inventory management system. 3.2. Hardware and Software 3.2.1. Install: Install the program and software packages used to add, delete, and edit items stored in the storage/dispensing stations on VA owned desktops or laptop computers at each designated facility. Install software on 1 (one at minimum) VA owned laptop for system set-up and installation. Install and prepare VA-owned server for transmission of information between Contractor and VA for maintenance and monitoring of equipment in use. Part Number (Set/Kit) Description SOFTWARE LICENSE FEES PX9186 PAR Bins Replenish License SCALE PRODUCTS Scale - Avg Cost for PAR Individual Scales SCALE PRODUCTS Scale - Avg Cost for PAR Individual Scales (15k) SCALE PRODUCTS Small & Medium Platform Scales SCALE PRODUCTS Large Platform Scales SCALE PRODUCTS Controller, Replenish, Ethernet HARDWARE PAR Hardware Accessories STORAGE PRODUCTS Plastic Storage Bins STORAGE PRODUCTS SC182472-5 18" D x 24" W x 72" H Chrome Wire Shelving Unit STORAGE PRODUCTS SC246084-5 24" D x 60" W x 84" H Chrome Wire Shelving Unit STORAGE PRODUCTS SC247284-5 24" D x 72" W x 84" H Chrome Wire Shelving Unit STORAGE PRODUCTS Bridge Allocation (unit plus sides/front) STORAGE PRODUCTS PX7532 Double-Wide Mass Med Cabinet and Louver Cart Panel STORAGE PRODUCTS PX7532-C Double-Wide Mass Med Cabinet and Louver Cart Pane STORAGE PRODUCTS QS-LR36 qwikSIGHT Mobile Louvered Panel Units, 36" STORAGE PRODUCTS QS-LR18 qwikSIGHT Mobile Louvered Panel Units, 18" IMPLEMENTATION SERVICES Onsite Implementation Services 3.2.2. Access: The system shall be accessible from multiple access points throughout the facility. Grant accesses and train VA employees for the program that shall have unlimited user access and provide reports and data mining capability of current inventory including, but not limited to, current stock levels, recommended order levels, and average usage levels. Software must support multiple users with different levels of permission. The system should be capable of producing reports in Excel or text delimited format using commercially available software. 3.2.3. Capabilities Including Physical, Function, and Performance Characteristics: The inventory management system shall have a HL7 Interface that communicates with VA GIP in VistA. The system must be an approved IT Authority to Operate (ATO) on the VA system at the time of offer. The system shall produce accurate real-time perpetual reading of quantities on-hand, accessible on VA provided computers via automated inventory management system software and provide data mining capabilities that shall include at a minimum current stock level, recommended order points, average usage levels per item. The periodic automatic replacement bin System must interface with Generic Inventory Package (GIP). The primary purpose of the interface is to accurately report on-hand quantities in real time for each secondary supply area for restocking purposes, and to identify out of balance on hand quantities and values between GIP and the periodic automatic replacement system. Periodic automatic replacement system will identify any out of balance on hand quantities and values, accounting for any due-outs or due-ins. If the out of balance condition is caused by a pending due in or due out, it will be displayed separately to easily identify. Periodic automatic replacement bin due-ins and due-outs will automatically be removed when GIP due-in and due-outs are cleared . 3.3. The functional and salient characteristics required: Must show equipment Status for communication about system status, including system failures. Must show Materials Management Status including: Open Orders Emergency/Critical Item Levels Negative Quantities on-Hand Must have an Item Locator function. Must have a Periodic Automatic Replacement (PAR) Level Analysis to advise the levels of inventory the facility needs to maintain in order to fulfill demand, which shall include: Current Levels Level recommendations by cost and usage demand SKU reduction recommendations Items over PAR level Stock outs and critical hits Par level value over time Must provide Consumption Data including: Average monthly usage Consumption analysis including time Consumption deviation Consumption over time Must generate reports including: Activity detail (sales, receipts, adjustments, etc.) to include date/time of any inventory changes Quantity on-hand / Value on-hand Department transactions Cycle count sheet Out of balance with GIP on-hand Due-ins / Due-outs Issue multiple discrepancy between GIP and BIN Emergency levels indicating low stock warning Generated reports must be relevant to APICS Principles of Inventory Management as VA requires all inventory systems communicating to VistA GIP/HL7 to provide reports. Must show orders: Existing orders Order preview Must show items describing: Item master / Item history Item classification Reconciliation history Most recent reconciliation per item Must be able to install the weight system compatible with the facility s current existing storage methods and infrastructure including shelving, cabinets, and carts. System must be accessible from multiple access points throughout the facility. Must be accessible on VA provided computers via automated inventory management system software. Employees must be able to recalibrate for different packaging sizes (10 vs 12 s) Must provide real-time visibility to primary and secondaries inventory locations (will provide the list as an attachment on the notice) Depletion of stock must rigger pick tickets based on Periodic Automatic Replenishment (PAR) levels, re-order points, and emergency stock level. All quantity on hand adjustment communication must be sent to GIP package to trigger accurate pick tickets. Must be capable of tracking, adjusting, and reporting comprehensive perpetual real time information pertaining to the inventory of secondary locations. Must be able to handle a wide range of medical/surgical products with variations of size, thickness, and weight, including but not limited to minimum scale of band aids, dressings, and maximum scale of large custom packs up to 3 ft long by 2 ft wide with a weight up to 20 pounds. Must have a training program available for VA staff, which should include but not limited to adding items, removing items, assigning items, editing items, troubleshooting, and reporting functions. 3.4. Licensing One-year license agreement for use of Inventory Management System and related support. Automatic software upgrades of the installed program and software. Web based program to be available on any computer and/or mobile device for evaluation of inventory levels and reporting purposes, for an unlimited number of users. On premises solutions will be considered. 3.4. Support Support must include continuous monitoring by means of a minimum of 4 remote checks of equipment functionality by Contractor personnel every 24 hours. Monitoring contractor personnel must provide notification and maintenance support in the event of a problem with equipment or software. Contractor personnel shall respond to service calls no later than 24 hours after being notified of a problem with either equipment or software installed. 24/7x365 service is required. Equipment and related hardware must be repaired and/or replaced within 48 hours of notification of a problem if user/facility is not at fault for damage or defect. The contractor may work with the site to resolve issues remotely for supported products. Solutions with real-time monitoring capable of identifying errors and equipment problems will be considered. 3.5. Performance Monitoring Completion of the installation will be verified by COR and/or designated personnel. Functionality and accuracy of the installed equipment will be continuously monitored by Supply Chain Management staff to ensure equipment is functioning properly and providing accurate and timely information for inventory and reordering purposes. Installed equipment and software is monitored by Contractor employees by daily check-ins that shall occur remotely at least 4 times every 24 hours. Contractor support to be provided for any defects or functionality problems by contacting Contractor via email or telephone within time frames designated in Section V. The Contractor will meet (e.g. in person, telephone, etc.) with the COR monthly to address any unresolved issues. Any unresolved and/or continuous issues will be referred to the Contracting Officer for corrective action. On-premises solutions will be considered. 4. Security Requirements Offeror shall identify vendor-owned software and/or programs that have to be installed on VA owned server, laptop, and desktop computer. Other access to vendor website and programs will be permitted by vendor from any desktop computer using the World Wide Web. Contractor personnel performing installation may be required to complete the Department of Veterans Affairs security screening. General Contractor s employees shall not enter the work area without the appropriate badge. They must present themselves to the facility VA Police for a Contractor s badge to be worn during the set-up of the system. They may be subject to inspection of their personal effects when entering or leaving the work area. 5. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI) The VAMC will furnish a server, laptop, and desktop computer for installation of vendor owned software and related programs need to make the installed equipment operational. 6. Other Pertinent Information or Special Considerations. Identification of Possible Follow-on Work. Service agreements and license agreements will be maintained and purchased after initial 1-year warranty is no longer effective. 7. Risk Control Employees of contractor responsible for installation and setup will have background check completed or show proof of background check completed no longer than one (1) year ago, from date of award including fingerprint analysis. Contractor employees shall obtain VA badge and wear on their person, above their waist and always visible. Contractor will be installing a supply storage and tracking system in an area under construction. Workers will need to be cognizant of staff movements, sensitive medical equipment, and diverse activities during certain periods of the workday. Installation staff shall have no patient contact or access to sensitive patient information. COR will be available for risk intervention should the need arise. 8. Period of Performance Installation to begin no later than 70 days after contract award date. The initial kickoff meeting to be scheduled no later than 70 days after contact award date. Equipment delivery and installation work is to begin as soon as the kickoff meeting ends. Installation will be phased by facility and will be at the discretion of the Contracting Officer Representative (COR) or Designee. The facility will provide the Contractor a deployment plan, to include time and location of installation. Installation and setup to be completed no later than 400 days after contract award date. This timeline is dependent on the facility meeting a facility required tasks and tollgates, otherwise the timeline will be revised via modification. The contractor must notify with any delays or issues to the Contracting Officer and Contracting Officer Representative in writing immediately. 9. Delivery All deliverables must be delivered to: VA Phoenix Healthcare System Main Warehouse (ATTN: Prentiss Logan) 650 E Indian School Road, Phoenix, AZ 85012 Contractors must notify the COR 5 business days prior of shipping deliverables. Contractors will ship all deliverables to VA Phoenix Main Warehouse. Contractor will help to stage products that will be onsite for VA to transport to each primary and secondary location prior to installation. If your company is interested in and capable of providing the required supplies/services, you MUST provide the information indicated below OR your intent, interest to participation, and information provided will not be considered as valid for research purposes. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements. For instances where your company cannot meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please explain. For instances where your company can meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please clearly show how your company meets/exceeds each requirement otherwise your response will be recorded as interest only . (2) Please review the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of DRAFT/SALIENT CHARACTERISTICS/SOW? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? Please indicate if manufacturer is/will be US domestic Small Business / US Domestic Large Business / Foreign. (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your organization offer a leasing solution? Please elaborate. (15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (18) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to sam.choo@va.gov. Telephone responses will not be accepted. Responses must be received no later than Monday, November 2, 2026 by 10:00 AM PST. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement. | 76% | Market Research | 11/02/2026 |
1.0 DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Scanning Systems Ultrasonic Portable. The EPO in conjunction with VHA is seeking qualified sources capable of supplying the brand name or equal Fujifilm® Sonosite Scanning Systems Ultrasonic Portable machines on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete ultrasonic scanning systems to VA medical centers and facilities throughout the United States. The associated North American Industry Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. The FAR Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation. You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission. Submissions for this Sources Sought Notice shall be submitted by email no later than October 19, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses: Alanna.Wilson@va.gov Anthony.Zibolski@va.gov Email responses shall include the following subject line: Response to Sources Sought Notice 36C10X27Q0004. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time. 2.0 SCOPE OF WORK Scanning Systems Ultrasonic Portable are compact devices that use high frequency sound waves for real-time internal body imaging. Point-of-care ultrasound (POCUS) imaging is routinely used by medical clinicians to guide interventional percutaneous procedures such as vascular access, nerve blocks, and therapeutic injections. Ultrasonic scanning systems have an ultrasonic scanner, transducers (frequencies of 2 to 12 MHz are typical for vascular and abdominal scanning, procedure guidance, and nerve blocks), dedicated software, DICOM software for PACS compatibility and image storage, and an image recorder. Most ultrasonic scanners include continuous-wave and pulsed-wave Doppler capabilities (including a spectrum analyzer) for sensing the velocity and location of blood flow; they can be operated in multiple modes, including color flow mapping mode and triplex mode (i.e., simultaneous acquisition and display of 2-D gray-scale, spectral Doppler, and color flow data). Ultrasonic scanning systems usually display images of the vessels in conjunction with spectrum analysis to depict the vessel and its obstructions. Some ultrasonic scanners use a low frequency (typically 2 MHz) Doppler transducer to obtain the blood flow velocity recording in the intracranial arteries. These systems are used for transdermal examinations and diagnosis of diseases, occlusions, and obstructions in the peripheral vascular system, including a profile of the blood-flow velocity in the area under examination. Most of them also include capabilities for small-part examinations. The following Contract Line Items (CLINs) are being considered: Contract Line Items Manufacture Part Number Description 0001 Sonosite L22916 Transducer, L12-3 0002 Sonosite L23117 Transducer, C10-3 0003 Sonosite L23119 Transducer, C5-1 0004 Sonosite L23120 Transducer, L15-4 0005 Sonosite L23121 Transducer, IC10-3 0006 Sonosite L23972 Transducer, L19-5 0007 Sonosite L24087 Transducer, P5-1 0008 Sonosite L25100 Sonosite PX Ultrasound System 0009 Sonosite L25110 Sonosite PX Stand 0010 Sonosite L25200 Printer, B and W Hybrid Graphic, SONY UP-X898MD 0011 Sonosite L27766 T8-3 ULT-2020 Ultrasound Leakage Tester Kit 0012 Sonosite L28354 Sonosite LX Ultrasound System 0013 Sonosite L29076 Sonosite ECG Module 0014 Sonosite L29465 Transducer, T8-3 12 Months - Standard Coverage Warranty 0015 Sonosite L29671 Transducer, P11-3 0016 Sonosite L30229 Transducer, T8-3 POCUS Bundle -12 Months - Standard Coverage Warranty 0017 Sonosite L30257 Transducer, L13-6 0018 Sonosite L31500 Sonosite ST Ultrasound System 0019 Sonosite L33270 Transducer, UHF46-20 MHz Ultra High-Frequency -12 Months - Standard Coverage Warranty 0020 Sonosite P31199 Steep Needle Profiling, Sonosite ST 0021 Sonosite P31440 Sonosite Voice Assist -12 Months - Standard Coverage Warranty 0022 Sonosite P31987 Small Basket 0023 Sonosite P31988 Large Basket 0024 Sonosite P32357 - Sonosite PIV Assist Sonosite PIV Assist 0025 Sonosite P32441-SVCCON Point of Sale Warranty Plus (2 years), PX System 0026 Sonosite P32442-SVCCON Point of Sale Warranty Plus (2 years), LX System 0027 Sonosite P32443-SVCCON Point of Sale Warranty Plus (2 years), ST System 0028 Sonosite P32444-SVCCON Point of Sale Warranty Plus (2 years), PX/LX/ST/MT Transducers (Not applicable for the T8-3 or UHF46x Transducers) 0029 Sonosite Sonosite Institute for Point-of-Care Ultrasound Exclusive access to over 100 hours of education including courses, videos, webinars, quizzes, certificates and additional resources. Accessible via desktop, tablet or phone. (Included) Respondents should identify a complete solution including associated accessories, as required for full functionality. The following Salient Characteristics (SCs) are being considered: CLINs 0001-0013, 0015, 0017, 0020 apply to the following SC 1-9 CLINs 0014, 0016, 0019, 0021 apply to the following SC 10 CLINs 0026-0028 apply to the following SC 12 CLIN 0029 applies to the following SC 11 SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC 1 Multiple configurations of the devices Literature Review SC 2 Must have High-quality image resolution1280 x 1024 pixels or higher Literature Review SC 3 Must have multiple Doppler modes to include color, and continuous Wave Literature Review SC 4 Must have 120V and Battery powered capability Literature Review SC 5 Must have a Phased Array Probe with a low frequency range of between 1-5 MHz Literature Review SC 6 Must have Endocavitary Probe with a frequency range between 2-12.5 MHz Literature Review SC 7 Must have Low to Mid Probe with a frequency range of at least 2-12 MHz Curvilinear Probe Literature Review SC 8 Must have Linear Probe with a frequency range greater than 12 MHz Literature Review SC 9 Must have needle visualization enhancement Literature Review SC 10 Must have a minimum one-year warranty Literature Review SC 11 Must provide Operator training Literature Review SC 12 Must provide Extended Service and Support plan Literature Review SC 13 Must be FDA approved FDA Letter SC 14 Must have Intraoperative system capable of interfacing with VA Electronic Health Record System Literature Review For each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above. The Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number. In addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors: Safety The device will be assessed for patient safety features, including, but not limited to, the following areas: Infection control Thermal injuries Probe maintenance Battery failure procedures Design Design features and functions of the offered device will be evaluated. Areas include but are not limited to the following: Durability of the system and the probes Display screens usability Barcode software to ID patients and physicians Low-Profile wheelbase to assist getting closer to patient Cordless charging station Number of Transducer ports Simplicity of system design for operator (ergonomics, easy setup, User-friendly software applications, reporting, and touch screen ease of use) Performance The device will be evaluated for its ability to perform its intended function. Areas include but are not limited to: Capabilities to support multiple medical services Batter run time Provided Installation Needle guidance system Quality/Construction/Training Extended Warranty Training Secure Data encryption HIPPAA/GDPR compliant Meets ANSI/AAMI ES6061 Electromechanical safety standards Responses to this Sources Sought Notice shall include the following: Full name and address of company. SAM Unique Entity Identifier (UEI). Business Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)). Manufacturer or Distributor: If distributor, provide the full name, business size and address of the manufacturer. If distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM. Country of Origin designation for all products proposed. Describe the firm s ability to provide uninterrupted supply of products on a national scale. Technical literature clearly demonstrating that the proposed product(s) meets the identified salient characteristics identifying the page number(s) where each requirement is met. Does respondent offer an annual service plan, Yes or No? If Yes: Describe what the plan covers? Identify whether the plan covers software updates, parts repair/replacement, or both Provide literature or other documentation describing the service plan. Identify whether service is provided by the OEM or a subcontractor. Identify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. Include the applicable brand name and part number. Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any. NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns. Does your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted. Identify any federal contract vehicles held by your firm through which your firm can provide this equipment. Are there any further standards or criteria VA should consider in a procurement action for this equipment? Are the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language. Any additional information the Government should know prior to issuing a solicitation. Describe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis. | 76% | Market Research | 10/19/2026 |
This is a combined synopsis/solicitation for commercial products prepared in accordance with the Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) Parts 12 and 15. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0005 is issued as a Request for Proposal (RFP) for NX EQ Ultrasonic Aspirator System: Tissue Ablation and related accessories. This acquisition is set-aside for Service Disabled Veteran Owned Small Business (SDVOSB) concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A PRICE COST SCHEDULE NX EQ Ultrasonic Aspirator System: Tissue Ablation for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide descriptive literature which will be used to determine the extent to which it meets the salient characteristics listed in the Attachment B Product Description. All of the salient characteristics listed in the solicitation must be met to be considered eligible for award. Those proposals which fail to meet all of the salient characteristics will be rated Unacceptable and will be ineligible for award. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract. | 74% | Combined Synopsis | 12/01/2026 |
This is a combined synopsis/solicitation for commercial products prepared in accordance with FAR part 12. This announcement constitutes the only solicitation. Proposals are being requested and a separate written solicitation will not be issued. Solicitation number 36C10X27R0004 is issued as a Request for Proposals (RFP) for Image-Guided Surgical Navigation Systems. This acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. Line Items: Refer to ATTACHMENT A - PRICE COST SCHEDULE_NX EQ Image-Guided Surgical Navigation System for CLINs, quantities, and units of measure. Description of Requirements: Offerors shall provide NX EQ Image-Guided Surgical Navigation Systems that meet the salient characteristics listed in ATTACHMENT B PRODUCT DESCRIPTION. Only new OEM equipment is acceptable. No refurbished, remanufactured, or gray market items will be considered. Delivery and Acceptance: Delivery is FOB Destination. Specific delivery locations and dates will be identified in individual orders issued under the contract. | 74% | Combined Synopsis | 11/05/2026 |
Sources Sought Notice Sources Sought Notice DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO) is issuing this Sources Sought Notice in accordance with FAR 10.002(b)(2) as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Ultrasound Therapy Systems: Tissue Ablation. The EPO in conjunction with VHA is seeking a qualified source to supply brand name, brand-name-or-equal, or sole-source specification for Ultrasound Therapy Systems: Tissue Ablation and associated equipment on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the required products to VA medical centers and facilities throughout the United States. The period of performance is for a base of 12-months with four 12-month option periods. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 and the associated size standard is 1,250 Employees. The FAR Provision found at 52.204-7(b)(1) requires that an offeror be registered in SAM when submitting an offer or quotation and at time of award. All respondents should have the appropriate NAICS code reflected in SAM. SDVOSB/VOSB respondents should maintain current certification in the SBA Veteran Small Business Certification program, as applicable. Submissions for this sources sought shall be submitted by email no later than September 30, 2026, at 9:00 am ET to: Michael.Andrews6@va.gov. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time. SCOPE OF WORK Ultrasonic Aspirators are surgical devices designed to fragment and remove soft tissue, bone, and tumors from various parts of the body. They are used during procedures in which surgical blades or blunt dissection instruments might damage surrounding healthy tissue or for cases in which a surgical laser would eradicate a lesion, leaving no specimen for pathological evaluation. Ultrasonic aspirators utilize mechanical vibration at ultrasonic frequencies for tissue removal while also providing suction and/or irrigation to the surgical site. The following Contract Line Items (CLINs) are being considered: Contract Line Items Manufacturer Part Number Description 0001 Integra LifeSciences C7411S CUSA CLARITY 36kHz CRV EXT MICROTIP (5-PACK) 0002 Integra LifeSciences C7412S CUSA CLARITY 36kHz STANDARD TIP (5-PACK) 0003 Integra LifeSciences C7414S CUSA CLARITY 36kHz CURVED EXT STD TIP (5-PACK) 0004 Integra LifeSciences C7415S CUSA CLARITY 36kHz CRV EXT PLUS MICROTIP (5-PACK) 0005 Integra LifeSciences C7417S CUSA CLARITY 36kHz CRV EXT SHEARTIP (5-PACK) 0006 Integra LifeSciences C7136 CUSA Clarity 36kHz Sterilization Tray 0007 Integra LifeSciences C7602 CUSA CLARITY 36kHz TORQUE WRENCH (5-PACK) 0008 Integra LifeSciences C7300 CUSA CLARITY QUICK CONNECT TUBING SET (5-PACK) 0009 Integra LifeSciences C7005 CUSA Clarity Contamination Guard 0010 Integra LifeSciences C7550 CUSA Clarity Specimen Trap 0011 Integra LifeSciences C7123 CUSA Clarity 23kHz Sterilization Tray 0012 Integra LifeSciences C7623 CUSA Clarity 23kHz Sterilizable Torque Base EACH1 0013 Integra LifeSciences C7601 CUSA Clarity 23kHz Torque Wrench (5-Pack) 0014 Integra LifeSciences C7502 CUSA Clarity 23kHz Handpiece Cleaning Brush 0015 Integra LifeSciences C7523 CUSA CLARITY 23kHz CEM NOSECONE (5 PACK) 0016 Integra LifeSciences C7401S CUSA Clarity 23kHz Standard Tip (5-pack) 0017 Integra LifeSciences C7405S CUSA Clarity 23kHz MacroTip (5-Pack) 0018 Integra LifeSciences C7418S CUSA Clarity 23kHz Tough Tissue Tip (5-pack) 0019 Integra LifeSciences C7420S CUSA Clarity 23kHz Bone Tip (5-pack) 0020 Integra LifeSciences C7002 CUSA Clarity Footswitch 0021 Integra LifeSciences C7421S CUSA Clarity 23kHz Single-Sided Bone Tip (5-Pack) 0022 Integra LifeSciences C7404LS Clarity 23kHz Extended Laparoscopic Tip, 5-Pack 0023 Integra LifeSciences C7636 CUSA Clarity 36kHz Sterilizable Torque Base EACH1 0024 Integra LifeSciences C7523X CUSA Clarity 23kHz Expanded CEM Nosecone - 5 Pack 0025 Integra LifeSciences C7411S CUSA CLARITY 36kHz CRV EXT MICROTIP (5-PACK) 0026 Integra LifeSciences C7412S CUSA CLARITY 36kHz STANDARD TIP (5-PACK) 0027 Integra LifeSciences C7414S CUSA CLARITY 36kHz CURVED EXT STD TIP (5-PACK) 0028 Integra LifeSciences C7415S CUSA CLARITY 36kHz CRV EXT PLUS MICROTIP (5-PACK) 0029 Integra LifeSciences C7417S CUSA CLARITY 36kHz CRV EXT SHEARTIP (5-PACK) The Department of Veterans Affairs (VA) is seeking vendors who can provide Cusa Clarity Ultrasonic Aspirator System, Ultrasound Therapy Systems: Tissue Ablation or equal commodities that meet the salient characteristics below. Vendors may provide any product solution or configuration that meets the requirement. For each offered product, the response should include descriptive literature demonstrating how the product meets or exceeds each salient characteristic. The following salient characteristics apply to the products identified below unless otherwise noted in the Product Description: CLIN s 0001 apply to the following SC s: SC1, SC2, SC3, SC4, SC5, SC6 CLIN s 0003-CLIN s 0029 apply to the following SC: SC7 SC # SALIENT CHARACTERISTICS Apply to CLIN # METHOD OF EVALUATION 1 Console includes a visual display that provides real-time feedback on ultrasonic power/amplitude, irrigation rate, and aspiration level, with numerical or graphical indicators. 0001 Literature Review 2 Provides combined ultrasonic fragmentation/emulsification, irrigation, and aspiration functions for soft and hard (including bone) tissue. 0001 Literature Review 3 Allows selective dissection of target tissue while preserving vessels, ducts, and other delicate structures 0001 Literature Review 4 Allows selective dissection of target tissue while preserving vessels, ducts, and other delicate structures 0001 Literature Review 5 System supports at least two ultrasonic handpieces with distinct operating frequencies (e.g., one high-frequency for fine, selective work and one lower-frequency/high-amplitude for efficient debulking of tougher tissue). 0001 Literature Review 6 System provides continuous irrigation from standard sterile saline or lactated Ringer s bags to the distal tip of the handpiece and aspiration of irrigation fluid, fragmented tissue, and debris to standard canisters via vacuum tubing. 0001 Literature Review 7 Reusable handpieces and components are compatible with standard hospital sterilization processes, including pre-vacuum steam sterilization cycles with manufacturer-specified dry times (e.g., 40 minute dry cycle) 0003-0029 Literature Review Responses to this Sources Sought Notice shall include the following: Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does the plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? Vendor is requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Full name and address of company UEI / CAGE Code / SAM registration information Business Size Manufacturer or Distributor If distributor, provide full name, business size, and address of manufacturer. Country of Origin designation for all products Ability to provide uninterrupted supply of products on a national scale Technical literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Authorized Distributor Letter certified by OEM with a current date. Although not required, vendors responding to this Sources Sought are highly encouraged to submit a Capabilities Statement. | 74% | Market Research | 09/30/2026 |
Additional Details
Solicitation Number
36C26226Q0127
Archive Date
Jan 14, 2026