GovChime
Notice ID: 0e5489f28f1648e1a67abda71bc91189Sources SoughtArchived

6515--644 - Electro-Surgical Analyzer

Archived on June 28, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM PDT
Posted
April 23, 2026
Notice type
Sources Sought
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of Veterans Affairs

Notice details

Office
262-NETWORK CONTRACT OFFICE 22 (36C262)
Place of performance
Department of Veterans Affairs Phoenix VA Health Care System, Phoenix, Arizona, 85012
PSC
6515: MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
36C26226Q0689
Notice ID
0e5489f28f1648e1a67abda71bc91189

Description

Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 6 Sources Sought Synopsis Only The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (hubzone, 8(a), small, small disadvantage, veteran owned small business (VOSB), service-disabled veteran owned small business (SDVOSB), or large business) relative to NAICS 334516 with size standards of 1,000 employees. Note that if VA s pending market research establishes that two or more VOSB or SDVOSB, who are certified in VA s Vendor Information Pages (VIP) site https://www.vip.vetbiz.gov/, can perform the project, VA will set aside the underlying solicitation per 38 U.S.C. §8127. Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Synopsis, a solicitation announcement may be published on SAM, and/or GSA eBuy. Responses to this Sources Sought Synopsis are not considered adequate responses to the solicitation announcement. General Requirements: The Department of Veterans Affairs (VA), Phoenix VA Health Care System, has a need for a biomedical engineering analyzer. The requirement is for brand name or equal to. Salient Characteristics: Item # Description Qty (ea) Country of Origin 398A912 Electro-Surgical Analyzer 2 Must be portable/battery powered Must have integrated oscilloscope Must have onscreen power profile analysis Must have onboard automation and data capture Must have full color user-interface Must be able to test cut AND coagulation feature from a remote foot switch control Must have high current test capability up to 6 Ampere RMS Must have a Non-inductive load bank from 0 5115 Must be capable of variable load AND fixed load Must have power range: 0-500W Must have current range: 0-6000mA Must have voltage range: 0-700V Must have crest factor range: 1.4-20 Must have bandwidth, with load bank, 30-2.5MHz Must have interference frequency filter: 100Hz high pass filter Must have all IEC 60601-2-2 leakage tests Participating Healthcare Facilities: VISN 22 West VA Long Beach Healthcare System 5901 East 7th St, Long Beach, CA 90822 In response to this announcement, please complete the information below: Company: Address: Contact Name: Phone No: Email: DUNS: Business size information Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HubZone Woman Owned Certified Service-Disabled Veteran Owned Small in Vetbiz.gov Certified Veteran Owned Small Business in Vetbiz.gov Large Business Other:____________ Are you a FSS/ GSA Contract Holder of the requested item(s)? If yes, provide the information below. Yes No FSS/ GSA Contract Number Effective Date / Expiration Date Does your company manufacture the requested product(s)? If no, answer the questions below. Yes No Does your company exceed the 500-employee alternative size standard for nonmanufacturers? Yes No Is your company primarily engaged in the retail or wholesale trade and normally sell the type of product(s) being supplied? Yes No Does your company take ownership or possession of the products(s) with its personnel, equipment, or facilities in a manner consistent with industry practice? Yes No Does your company supply the end product(s) of a small business manufacturer or processor made in the US, or obtain a waiver of such requirement? Yes No Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes. Not applicable List: This notice is neither a request for competitive proposal or solicitation of offerors. This notice is to assist the VA in determining sources only and a solicitation is not currently available. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from this response. Responses to this Sources Sought is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Information received as a result of this notice will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. This notice does not represent a commitment by the Government to pay for costs incurred in the preparation and submission of information or any other costs incurred as a response to this announcement. Inquiries will only be accepted in writing via email to Jasmine.Pressley-Barnard@va.gov on or before Wednesday, April 29, 2026 by 10:00 AM PT Local Time. ***** End Word Document - ' OPPORTUNITIES-DESCRIPTION' *****

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Jasmine Pressley-Barnard
Contract Specialist

Documents

Files (1)

  • 36C26226Q0689.docx

    22 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    6515--644 - Electro-Surgical Analyzer

    Notice 0e5489f28f1648e1a67abda71bc91189 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

36C26226Q0689

Archive Date

Jun 28, 2026

Office Address

Gilbert, AZ, 85297